Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

References Enclosed motor starters

Direct-on-line starters
Without thermal overload relay (1)

Direct-on-line starters Composite steel/plastic enclosure. Ingress protection: IP 65

Maximum Maximum kW rating Control Reference Weight


current rating Utilisation category supply
category AC3
AC 220/230 V 380/415 V
A kW kW V kg

Direct-on-line starters without disconnect switch

12 3 5.5 240 LE1-GBKO55U7 1.340


50/60 Hz

415 LE1-GBKO55N7 1.340


50/60 Hz
LE1-GBKO55U7

25 5.5 11 240 LE1-GBTO11U7 1.340


50/60 Hz

4 415
50/60 Hz
LE1-GBTO11N7 1.340

Direct-on-line starters with reset button only

12 3 5.5 240 LE1-GBKO55U7A05 1.330


50/60 Hz

415 LE1-GBKO55N7A05 1.330


50/60 Hz

4.3
25 5.5 11 240 LE1-GBTO11U7A05 1.330
50/60 Hz
LE1-GBKO55U7A05

415 LE1-GBTO11N7A05 1.330


50/60 Hz

Direct-on-line starters with disconnect switch

12 3 5.5 240 LE1-GBKS55U7 2.620


50/60 Hz

415 LE1-GBKS55N7 2.620


50/60 Hz

LE1-GBKS55U7
25 5.5 11 240 LE1-GBTS11U7 2.620
50/60 Hz

415 LE1-GBTS11N7 2.620


50/60 Hz

(1) Select thermal overload relay separately. See pages 2/46 and 2/112.

Dimensions, schemes:
pages 4/30 and 4/31
4/26
References Enclosed motor starters
Direct-on-line reversing starters
Without thermal overload relay (1)

Direct-on-line reversing starters Composite steel/plastic enclosure. Ingress protection: IP 65

Maximum Maximum kW rating Control Reference Weight


current rating Utilisation category supply
category AC3
AC 220/230 V 380/415 V
A kW kW V kg

Direct-on-line reversing starters without disconnect switch

12 3 5.5 240 LE2-GBKO55U7 2.620


50/60 Hz

LE2-GBKO55U7

415 LE2-GBKO55N7 2.620


50/60 Hz

25 5.5 11 240 LE2-GBTO11U7 2.620


50/60 Hz
4

415 LE2-GBTO11N7 2.620


50/60 Hz

Direct-on-line reversing starters with disconnect switch

12 3 5.5 240 LE2-GBKS55U7 3.820


50/60 Hz 4.3

415 LE2-GBKS55N7 3.820


LE2-GBKS55U7 50/60 Hz

25 5.5 11 240 LE2-GBTS11U7 3.820


50/60 Hz

415 LE2-GBTS11N7 3.820


50/60 Hz

(1) Select thermal overload relay separately. See pages 2/46 and 2/112.

Dimensions, schemes:
pages 4/30 and 4/31
4/27
References Enclosed motor starters
Star-delta starters
Without thermal overload relay (1)
With mechanical/electrical interlock

Automatic star-delta starters Composite steel/plastic enclosure. Ingress protection: IP 65

Maximum kW rating Control Reference Weight


Utilisation category supply
AC3
380 V 415 V 440 V
kW kW kW V kg

Automatic (2) star-delta starters without disconnect switch

11 11 11 240 LE3-GBTO11U7 3.820


50/60 Hz
LE3-GBTO11U7

415 LE3-GBTO11N7 3.820


50/60 Hz

18.5 22 22 240 LE3-GBTO22U7 3.820


50/60 Hz

4 415
50/60 Hz
LE3-GBTO22N7 3.820

Automatic (2) star-delta starters with disconnect switch

11 11 11 240 LE3-GBTS11U7 3.820


50/60 Hz

415 LE3-GBTS11N7 3.820


50/60 Hz
LE3-GBTS11U7
4.3
18.5 22 22 240 LE3-GBTS22U7 3.820
50/60 Hz

415 LE3-GBTS22N7 3.820


50/60 Hz

Automatic (2) star-delta starters without disconnect switch Sheet steel enclosure. Ingress protection: IP 55

25 30 30 240 50/60 Hz LE3-D325U7A06A64 5.160

415 50/60 Hz LE3-D325N7A06A64 5.160

37 37 37 240 50/60 Hz LE3-D405U7A06A64 8.160

415 50/60 Hz LE3-D405N7A06A64 8.160

55 59 59 240 50/60 Hz LE3-D505U7A06A64 8.160

415 50/60 Hz LE3-D505N7A06A64 8.160

75 75 75 240 50/60 Hz LE3-D805U7A06A64 14.000

LE3-D405U7A06A64 415 50/60 Hz LE3-D805N7A06A64 14.000


(1) Select thermal overload relay separately. See page 2/112.
Overload relay should be selected for setting at 0.58 x Motor full load current.
(2) The star-delta timer imposes a delay of 40 ms ±15 ms on the delta contactor at the moment of changeover to ensure
that the star contactor has sufficient breaking time.

Dimensions, schemes:
pages 4/30 and 4/31
4/28
References Enclosed heating and
lighting contactors
Enclosed contactors
Without thermal overload relay
Without pushbutton controls

Heating and lighting contactors Composite steel/plastic enclosure. Ingress protection: IP 65

Maximum Poles Control Reference Weight


continuously supply
rated operat-
ional current
A V kg

Heating and lighting contactors

25 3 + Neutral 240 LE1-GBTHL25U7 1.340


50/60 Hz

415 LE1-GBTHL25N7 1.340


50/60 Hz

LE1-GBTHL25U7

32 3 + Neutral 240 LE1-GBTHL32U7 1.340


50/60 Hz

4
415 LE1-GBTHL32N7 1.340
50/60 Hz

50 3 + Neutral 240 LE1-GBTHL50U7 2.620


50/60 Hz

4.3

415 LE1-GBTHL50N7 2.620


50/60 Hz

80 3 + Neutral 240 LE1-GBTHL80U7 2.620


50/60 Hz

415 LE1-GBTHL80N7 2.620


50/60 Hz

Accessories
Description Sold in Reference Weight
lots of kg

Pushbutton blanking plate 2 LE1-BL1 0.002

Disconnect switch blanking plate 2 LE1-BL2 0.002

Dimensions, schemes:
pages 4/30 and 4/31
4/29
Dimensions Enclosed motor starters

Direct-on-line starters without disconnect switch


LE1-GBiOiii7 (A05)

119.00
79.50

212.00
119.00
165.00 114.00
207.70 32 32

35

139.50 32
124 156.5
150.56

3 x 20 mm ISO conduit entries top and bottom.

Direct-on-line starters with disconnect switch


LE1-GBiSiii7
Reversing D.O.L. starters without disconnect switch
LE2-GBiOiii7

4
209.70
159.00

209.70
219.00 204
55 55
174.00

214.70 46

163.70 47
174.70
214.00 206.90
4.3
2 x 20 mm and 1 x 25 mm ISO conduit entries
top and bottom.
Reversing D.O.L. starters with disconnect switch
LE2-GBiSiii7
Star-delta starters without disconnect switch
LE3-GBTOiii7

299.00
252.00

225.00
174.00
220.70

163.70
174.70
304.00 206.90

299.00
294.00
90 90

46

47

2 x 25 mm and 1 x 20 mm ISO conduit


entries top and bottom.

References:
pages 4/26 to 4/29
4/30
Dimensions Enclosed motor starters

Star-delta starters without disconnect switch, 30 - 75 kW


LE3-D325iiiA06A64 LE3-D405iiiA06A64, D505iiiA06A64

LE3-D805iiA06A64
= 325 =

Knock-outs or blanking plugs for cable glands


(gland size in mm, P = Plastic)
= Type of At At
enclosure top bottom
LE3-D325 1 × 21 P 1 × 21 P, 2 × 13 P and
2 × 16 P
4
400(4)

457,5

325
350

LE3-D405 1 × 29 P 1 × 29 P, 2 × 13 P and
2 × 21 P
LE3-D505 1 × 36 P 1 × 36 P, 2 × 13 P and
4xM8x25 2 × 29 P
LE3-D805 1 × 36 P 2 × 13 P and 3 × 36 P
=

202 350
218 400
457,5

4.3

References:
pages 4/26 to 4/29
4/31