Professional Documents
Culture Documents
Submittal PDF
Submittal PDF
Submittal PDF
ENGINEER:
SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION:
FEATURES
_
COOLING PERFORMANCE
• EXCEEDS ASHRAE 90.1-2004 / MEETS EPACT 2010 EFFICIENCY*
TOTAL CAPACITY- - - - - - - - - - - - - - _____ MBH • SIMPLICITY® CONTROLS
OUTDOOR DESIGN TMP. - - - - - - - - - - _____ °F • R-410A REFRIGERANT
• POWDER PAINT FOR DURABILITY
SUCTION PRESSURE AT • WEATHERIZED CASING FOR OUTDOOR USE
SATURATION - - - - - - - - - - - - - - - - - _____ PSIG • PROPELLER-TYPE CONDENSER FANS
SUCTION TEMPERATURE AT • INHERENTLY PROTECTED FAN MOTORS
• HIGH AND LOW PRESSURE SAFETIES
SATURATION - - - - - - - - - - - - - - - - - - - _____ °F
• SCROLL COMPRESSORS
ELECTRICAL DATA • CRANKCASE HEATERS
• ALUMINUM TUBE/ALUMINUM FIN “MICROCHANNEL” COILS
POWER SUPPLY - - - - - - - - - _____/_____/_____ • BACKSEATING SUCTION AND LIQUID LINE SERVICE VALVES
• SINGLE AND DUAL REFRIGERATION CIRCUITS
TOTAL UNIT AMPACITY - - - - - - - - _____ AMPS (SINGLE ON YC AND DUAL ON YD MODELS)
POWER INPUT REQ. - - - - - - - - - - - - - _____ KW • LOW AMBIENT TO 40°F - LOW AMBIENT AVAILABLE TO 0°F
• PROVISIONS FOR HOT GAS BYPASS
MINIMUM WIRE SIZE - - - - - - - - - - - - _____ AWG • CSA APPROVAL
(COPPER CONDUCTORS) • ONE YEAR LIMITED PARTS WARRANTY ON COMPLETE UNIT
MAXIMUM FUSE SIZE - - - - - - - - - - _____ AMPS • FIVE YEAR LIMITED COMPRESSOR WARRANTY
• LIQUID LINE DRIERS (SUPPLIED FOR FIELD INSTALLATION)
(DUAL ELEMENT)
• FACTORY INSTALLED DISCONNECT OPTION
UNIT WEIGHT • FACTORY INSTALLED POWERED OR NON-POWERED 120V OUT-
LET OPTION
TOTAL OPERATING WEIGHT - - - - - _____ LBS • FULL PERIMETER BASE RAIL-FORK TRUCK ACCESSIBLE
• CRANE RIGGING PROVISIONS
WEIGHT DISTRIBUTION
LEFT
D A
LEFT
DIM X
D A
DIM X CG
CG
FRONT REAR FRONT REAR
WIDTH
C B
WIDTH
DIM Y
LENGTH
RIGHT C B
YC090, YC120, YD120,
YC150, YD150 DIM Y
LENGTH
RIGHT
YC180, YD180,
YC240, YD240,
YC300
UNIT DIMENSIONS
REAR FRONT
LEFT
CONVENIENCE
OUTLET
2X (Ø 1.375)
KNOCKOUT
30.994
2X (Ø 0.875)
KNOCKOUT
12.126
9.876
4.751
3.883
7.000 10.000 7.000 7.000 23.000 7.000
3.664
37.000
24.000 2.933
31.758 1.664
58.500
FRONT RIGHT
SYSTEM 2
2X (Ø 0.875)
KNOCKOUT
2X (Ø 1.375)
KNOCKOUT
15.53
12.70 12.000
SYSTEM 1 10.000
4.875
6.26
4.132
7.52
8.98 2.382
REAR 10.60 LEFT 1.882
*See UNIT HEIGHT DIMENSIONS, PIPING AND ELECTRICAL CONNECTIONS SIZES (next page)
YD120 50.0 Suction Line OD (in.) 1 1/8 1 3/8 1 1/8 1 3/8 1 1/8
YC150 50.0 Liquid Line OD (in.) 5/8 7/8 5/8 7/8 5/8
YD150 50.0 Power Wiring Knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8
Control Wiring Knockout 7/8 7/8 7/8 7/8 7/8
UNIT DIMENSIONS
REAR
LEFT RIGHT
FRONT
A
SYSTEM 2
SYSTEM 1
2X (Ø 1.375)
30.994 KNOCKOUT
2X (Ø 0.875)
KNOCKOUT
11.375
9.125
4.750
FRONT RIGHT
SYSTEM 2
SYSTEM 1
16.133
13.133
17.367
18.867
20.617
22.617
FRONT
(PIPING DETAIL)
*See UNIT HEIGHT DIMENSIONS, PIPING AND ELECTRICAL CONNECTIONS SIZES (next page)
YC240 50.0 Suction Line OD (in.) 1 5/8 1 3/8 1 5/8 1 3/8 1 5/8
YD240 50.0 Liquid Line OD (in.) 7/8 5/8 7/8 5/8 7/8
YC300 50.0 Power Wiring Knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8
Control Wiring Knockout 7/8 7/8 7/8 7/8 7/8
MINIMUM CLEARANCES
CLEARANCE DESCRIPTION DISTANCE IN INCHES
NOTES:
____________________________________________________________________________________________________
____________________________________________________________________________________________________
____________________________________________________________________________________________________
____________________________________________________________________________________________________
____________________________________________________________________________________________________