Technical Bulletin No.

RTB-001
SUBJECT: Service Manual Correction DATE: April 30, ’95
PAGE: 1 of 1
PREPARED BY: S. Hizen FROM: 2nd Technical Support Section
CHECKED BY: M. Iwasa
CLASSIFICATION: MODEL:
Action Required Revision of service manual Robin
Troubleshooting Information only
Retrofit Information Other

User-Code 0 (U-0)

The User-code 0 (U-0) is missing in the code section of your service manual page 4-24.
Please add the User-code 0 in your service manual.

U-0:

The first scanner may accidentally move away from its home position during transportation
/ location change of the machine. If the main switch is turned on under this condition, U-0
appears.

Solution:

Turn the main switch off and on to eliminate the U0 code.

NOTE: U-0 is different from E21/E22. The scanner home position sensor has no problem
for U-0, while the sensor may be defective for E21/E22.
Technical Bulletin No. RTB-002
SUBJECT: Upper Unit Opening Problem DATE:May 15, ’95
PAGE: 1 of 5
PREPARED BY: S. Hizen FROM: 2nd Technical Support Section
CHECKED BY: M. Iwasa
CLASSIFICATION: MODEL:
Action Required Revision of service manual Robin (A151 / A152)
Troubleshooting Information only
Retrofit Information Other

- Problem -

When the upper unit without the document feeder is released, it tends to open very
abruptly.

- Cause -

The torsion spring force is too strong.

- Temporary countermeasure for the production machines -

To reduce the torsion force, parts of the front and rear angle brackets which support the
torsion spring have been cut off as shown:

Part cut off

The cut-in serial numbers for this modification are as follows:


Machine Code Cut-in Serial Number Machine Code Cut-in Serial Number
A151 - 10 2674090001 A152 - 10 2694090001
A151 - 15 1A24090001 A152 - 15 1A34090001
A151 - 16 From 1st Production A152 - 16 From 1st Production
A151 - 17 A3604092283 A152 - 17 A3614090001
A151 - 22 2664100001 A152 - 22 2684090001
A151 - 24 From 1st Production A152 - 24 From 1st Production
A151 - 25 2664100089 A152 - 25 2684090216
A151 - 26 3F21040001 A152 - 26 3F30940001
A151 - 27 A3604100001 A152 - 27 A3614091301
A151 - 28 From 1st Production A152 - 28 From 1st Production
A151 - 29 A3604103600 A152 - 29 A3614092170
Technical Bulletin No. RTB-002
SUBJECT: Upper Unit Opening Problem DATE: May 15, ’95
PAGE: 2 of 5

- Permanent countermeasure for the production machines -

To make it possible to adjust the force of the upper unit opening in the field, the
configurations of the front and rear angle brackets have been changed as shown.

Old New

P/N A1521198
P/N A0771098 (Torsion Bar Angle Bracket-Rear)
(Torsion Bar
P/N A0771197 Angle - Rear) P/N A1521197
(Torsion Bar (Torsion Bar Angle (S/Ns of Dec. production
Angle - Front) unit will be put in) - Front)
The Cut-in serial numbers for this modification are as follows:
Machine Code Cut-in Serial Number Machine Code Cut-in Serial Number
A151 - 10 2675030001 A152 - 10 2695020001
A151 - 15 1A25030001 A152 - 15 1A35020001
A151 - 16 2675030051 A152 - 16 ----
A151 - 17 A3605030154 A152 - 17 A3615030945
A151 - 22 2665020001 A152 - 22 2685030001
A151 - 24 ---- A152 - 24 ----
A151 - 25 2665020116 A152 - 25 2685030121
A151 - 26 3F20350001 A152 - 26 3F30350001
A151 - 27 A3605030001 A152 - 27 A3615030001
A151 - 28 ---- A152 - 28 ----
A151 - 29 A3605030754 A152 - 29 A3615032090

- How to adjust the force of the upper unit torsion spring -

1. Make sure that the main switch is turned off and


the power supply cord is unplugged.

2. Remove the platen cover or DF.

3. Open the front cover.

4. Remove the following covers and units.


• Development unit
• Upper rear cover [B]
[A]
• Upper left cover [A]
5. Remove the front and rear upper unit stoppers [B] (1 screw each).
Technical Bulletin No. RTB-002
SUBJECT: Upper Unit Opening Problem DATE: May 15, ’95
PAGE: 3 of 5
6. Open the upper unit gently while holding it until the upper unit stops at the 90° position
as shown.

7. Remove the inner cover [D] (2 screws).

8. Adjust the force of the


torsion spring as
follows:

Front Rear

- Factory Setting - Factory


Setting B A
A B Factory - Strongest Setting -
Setting
• Remove screw C
on both sides
• Loosen screw A
on both sides •Screw
Torsion C
C • Shift the
Spring adjusting bracket
•Screw Torsion
toward the Spring
torsion spring.
A B • Tighten screws B
on both sides in A
positions B and A.

Strongest
C Strongest Setting
Setting C
Technical Bulletin No. RTB-002
SUBJECT: Upper Unit Opening Problem DATE: May 15, ’95
PAGE: 4 of 5

Front Rear
- Factory Setting -
C C B A
- Strongest Setting -
Remove the adjusting
bracket (2 screws on
B each side)
A
• Rotate the
bracket 180°
and install it
•Screw using holes A
and C. •Screw
A
B C
A

C B

- Factory Setting -
B A
C - Weak Setting -

• Remove the
adjusting
B bracket (2
A screws on each C
side).
•Screw • Rotate the
bracket 180° •Screw B C
A and install it
using holes B
and A.

A
C B
Technical Bulletin No. RTB-002
SUBJECT: Upper Unit Opening Problem DATE: May 15, ’95
PAGE: 5 of 5

- Countermeasure for the field machines -

For field machines, we have prepared the following plate as a countermeasure part to add
weight to the upper unit.

P/N A1519900 Plate – 3.9 x 75 x 320 mm

Please install two of the above plates on the machines as described in the following
procedure:

- Installation Procedure -

1. Open the upper unit while holding on to it.

2. Remove the right cover [A] (2 screws).

3. Clean the right development stay [B] with alcohol.

4. Peel off the seal from the plate [C] and stick the plate on the right development stay.

5. Clean the surface of the plate with alcohol.

6. Stick the second plate [D] onto the first plate.

7. Reassemble the machine.

[C] [C] [D]


[B]

[A]
REVISED ON DECEMBER 15, ’95 : Revised

Technical Bulletin No. RTB-003


SUBJECT: Energy Star DATE:September
30, ’95
PAGE: 1 of 4
PREPARED BY: N. Kaiya FROM: 2nd Technical Support Section
CHECKED BY: M. Iwasa
CLASSIFICATION: MODEL:
Action Required Revision of service manual Robin
Troubleshooting Information only -10, -15, -17 only
Retrofit Information Other
This RTB explains the modifications made to meet the Energy Star specifications.

With this modification, to conserve energy, the copier automatically turns off 30 minutes
after the last copying job has been completed.

The details of the machine operation can be found on pages 3 to 4 of this RTB.

Auto Off Mode


To automatically turn off the copier, a new type of main switch with an incorporated coil
is used. When the CPU drops CN126-1 from +24V to 0, the main switch contact is
opened. The P to P wiring diagram and connector layout are shown below.

TO T402

TO T401 To Safety Switch (SW2)


Main Control Board
CN126-1
[ 24] Main Switch
Co CN126-2
[ 24 ] VA

Main Switch

Main Control Board

DC Harness

Harness
Main Switch
REVISED ON DECEMBER 15, ’95 : Revised

Technical Bulletin No. RTB-003


SUBJECT: Energy Star DATE:September
30, ’95
PAGE: 2 of 4
SP Mode
The following two modes have been newly provided. *
Mode No. Function Settings
Auto off time can be selected 0 : 30 minutes (default)
1 : 15 minutes
SP14 2 : 1 hour
3 : 1.5 hours
4 : 2 hours
Output check for the main switch
SP9-7
(the machine will turn off)
The auto off time can also be selected by the customer.
Please refer to page 3 of this RTB for the procedure.

Instruction Sheet
An additional explanation sheet has been added to the operating instructions booklet.
Please refer to pages 3 and 4 of this RTB for the contents of this sheet. The Energy
Saver Mode described on the second page of this instruction sheet is the Auto Energy
Saver Mode originally available with this copier.
REVISED ON DECEMBER 15, ’95 : Revised

Technical Bulletin No. RTB-003


SUBJECT: Energy Star DATE:September
30, ’95
PAGE: 3 of 4

*
REVISED ON DECEMBER 15, ’95 : Revised

Technical Bulletin No. RTB-003


SUBJECT: Energy Star DATE:September
30, ’95