User Manuel: Dcb-I Folding Door Control Board

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

Lifkon Electric Electronic

DCB-I

DCB-I
FOLDING DOOR CONTROL BOARD

USER MANUEL

D.No: 006 - D.Ver: 104 - 27.04.2015 - www.lifkon.com

All rights reserved. 1 / 10


Lifkon Electric Electronic

DCB-I
INDEX
INTRODUCTION ............................................................................................................................... 3
TECHNICAL SPECIFICATIONS ....................................................................................................... 4
CONNECTION SCHEMATIC ............................................................................................................ 5
OPERATIONS ..................................................................................................................................... 6
MENU .................................................................................................................................................. 6
DOOR MOVEMENTS ........................................................................................................................ 9
INSTALLATION ............................................................................................................................... 10

D.No: 006 - D.Ver: 104 - 27.04.2015 - www.lifkon.com

All rights reserved. 2 / 10


Lifkon Electric Electronic

DCB-I
INTRODUCTION

DCB-I is an folding door control card. Door movements can be performed fast and safely by
intelligent control algorithm. It is possible to achieve properly, safely and fast door solutions with
its high technology.
 Device performs five zone control with high speed 32 bits Microprocessor
 DCB-I performs fast and soft door movements with PID algorithm and S curve.
 Driver components are much more powerful than competitors. This means, possible
effects of mechanical friction to door movement and risk of break down are minimized.
 DCB-I has five zones control algorithm for both open and close. It uses S curve for
acceleration and deceleration ramps.
 By simple settings menu, device facilitates door commissioning.
 Device protects motors and itself from overload and short circuit situations by monitoring
current.
 It supports electrical emergency operation by 24V DC battery input.
 Sound warming is supported in nudging time.
 Can operate with CAN-OPEN protocol.(not functional for standard products)

D.No: 006 - D.Ver: 104 - 27.04.2015 - www.lifkon.com

All rights reserved. 3 / 10


Lifkon Electric Electronic

DCB-I
TECHNICAL SPECIFICATIONS

Maximum Minimum Recommended Unit


Supply Voltage - - 20 V-AC
Supply Voltage Frequency 60 50 50 Hz
Transformer Power - 60 100 Watt
LP1-LP2 Inputs Voltage 240 100 220 V-AC
Working Temperature 70 5 25 ºC
DC Input Voltage (OL and CL) 30 20 24 V
DC Input Current (OL and CL) 8,36 4,6 5,7 mA
DC Output Voltage (COM) 30 20 24 V
DC Output Current (Encoder 200 - - mA
and COM)
Motor Voltage 24 - - V
Motor Current 10 - - A
Motor Speed 5000 - - RPM
Encoder Hole Number 50 20 40 A

D.No: 006 - D.Ver: 104 - 27.04.2015 - www.lifkon.com

All rights reserved. 4 / 10


Lifkon Electric Electronic

DCB-I
CONNECTION SCHEMATIC

D.No: 006 - D.Ver: 104 - 27.04.2015 - www.lifkon.com

All rights reserved. 5 / 10


Lifkon Electric Electronic

DCB-I

OPERATIONS

1. Normal Mode
In normal Mode, Door opens or closes according to the pump signal applied to LP1 and LP2
inputs.

2. Revision Mode
In Main Menu screen, if you press of “ESC” button long, door can be set into the Revision
Mode. When the device is in revision mode, door motor is de-energized. By this way the operator
can intervene the door manually (by hand). And Also the door can be moved within the limits with
“UP” and “DOWN” buttons .
By short press of “ESC” button exits Revision Mode. After exiting Revision mode, if CLOSE
signal is present and Learn Run had been performed, door will be closed in slow speed. If OPEN
signal is present and Learn Run had been performed, door will be opened in slow speed.

3. Learn Run Mode

In this mode, Learn Run operation is performed with the door is opened and closed in learn run
speed. After operation of Learn run, automatically assigned door moving region parameters will be
recorded.
When the device is energized first time, it will perform to learn run operation for first –time. To
perform a learn run , press “ENTER” for a minute in main menu
4. Battery Mode

If 20V-AC supply voltage fails, Door opens with warning sound and door doesn’t move until
supply voltage exists.

5. Nudging Mode

While the door is moving in normal mode, if nudging is determined, door opens if it is closing or
closes if it is opening.
MENU

Device has a LCD and 4 Butons on it. Buttons are “ESC”, “ENTER”, “UP” and “DOWN”.
When the device is energized first, shows main screen. Fist line shows status of door (Open, Close,
Opening, Closing and Nudging) and the second line shows “KP”, door position, “MH”, speed.
By press of “ENT” button for a minute to enter main menu from main screen. In the main menu
screen parameters can be shown with up and down buttons. To change parameter press “ENT” short.
After changing parameter, press “ENT” to save or press “ESC” to escape without save. To exit from
main menu, press “ESC” button short.
D.No: 006 - D.Ver: 104 - 27.04.2015 - www.lifkon.com

All rights reserved. 6 / 10


Lifkon Electric Electronic

DCB-I

00) Language (Turkish/English)


MAIN 01) Switch Type

MENU 02) Operation Counter

03)Demo Mode

04) Manufacturer Code

05) Close Start Speed (Pulse/sec)

06) Close Acceleration Ramp Region (Pulse)

07) Close High Speed (Pulse/sec)

08) Close Deceleration Ramp Region (Pulse)

09) Close Slow Speed (Pulse/sec)

10) Close Slow Speed Region (Pulse)

11) Close Constant Force

12) Open Start Speed (Pulse/sec)

13) Open Acceleration Ramp Region (Pulse)

14) Open High Speed (Pulse/sec)

15) Open Deceleration Ramp Region (Pulse)

16) Open Slow Speed (Pulse/sec)

17) Open Slow Speed Region (Pulse)

18) Open Constant Force

19) Learn Run Speed (Pulse/sec)

20) Nudging Force

21) Nudging Speed (Pulse/sec)

22) Partial Open/ Close

23) Partial Open / Close Speed (Pulse/sec)

24) Current Limit

25) Contrast

D.No: 006 - D.Ver: 104 - 27.04.2015 - www.lifkon.com

All rights reserved. 7 / 10


Lifkon Electric Electronic

DCB-I
Tablo-4 Ana Ekran

MENU FACTORY MİN- MENU FACTORY MİN-MAX


DEFAULTS MAX DEFAULTS
00- Language Turkish Turkish- 13-Open Assigned 0-X
English Acceleration automaticall
Ramp y
01- Switch NC NC-NO 14- Open High 1500 P/Sec 500-5000
Type Speed
02- Operation - - 15- Open Assigned 0-X
Counter Deceleration automaticall
Ramp y
03- Demo Passive Active- 16- Open Slow 150 P/Sec 100-1000
Mode Passive Speed
04- 0 0-X 17- Open Slow Assigned 0-X
Manufacturer Speed automaticall
Code Dimension y
05- Door 500 P/Sec 50-1000 18- Open %5 %5 - %25
Start Speed Constant
Force
06- Close Assigned 0-X 19- Learn Run 250 100-1000
Acceleration automatically Speed
Ramp
07- Close 1000 P/Sec 500-5000 20- Nudging 50 1-250
High Speed Force
08- Close Assigned 0-X 21- Nudging 400 200-1000
Deceleration automatically Speed
Ramp
09- Close 150 P/Sec 100-1000 22- Partial Passive Active-Passive
Slow Speed Open/ Close
10- Close Assigned 0-X 23- Partial 250 100-1000
Slow Speed automatically Open/Close
Dimension Speed
11-Close %5 %5 - %25 24- Current 15 A 10 A - 20 A
Constant Limit
Force
12- Open 500 P/Sec 50-1000 25- Contrast % 50 % 20 - % 99
Start Speed

D.No: 006 - D.Ver: 104 - 27.04.2015 - www.lifkon.com

All rights reserved. 8 / 10


Lifkon Electric Electronic

DCB-I

Partial Open/ Close:


 If this parameter is PASSIVE, even while the door is closing the pump signal is interrupted;
the door is completely closed, then opened. If pump signal is present while the door is
opening, the door is completely opened then closed.
 If this parameter is ACTIVE, while the door is closing if the pump signal is interrupted; the
door stops and reopens in partial open/close speed. While the door is opening if the pump
signal is present, the door stops and recloses in partial open/close speed.

DOOR MOVEMENTS

Door movements in the base;

I. Acceleration Region
II. Door High Speed Region
III. Deceleration Region
IV. Door Slow Speed Region

Performed in 4 regions above

PID control algorithm is utilized to achieve the target speed in each zone. Also the transition
between zones is performed fast and smoothly in acceleration and declaration zones.

When the door reaches the limit, open or close operations are completed. In this region, door
is held open or close with reduced torque which is set by “Constant Force” parameter.