ULTRASONIC DIFFUSER/HUMIDIFIER

MODEL: MVK-2

Daily maintenance
Keep the machine clean, clean the machine periodically, clean the
limescale and the dust gauze frequently, keep it dry and store it in dry
place.
The way to clear the atomization sheet and base
channel
Unplug before cleaning the machine
Dilute the detergent and pour it into the base by adding 45 C water to dissolve the
detergent. Soak for 10 minutes and gently scrub the surface with a small brush until scale
is removed. Wash the base with 1:1 of water and white vinegar or citric acid. Then clean
the base and surface with water.

Product instructions:
1. Do not put anything below the machine, it will affect the air intake.
2. Open the tank cover, add water, close the tank cover, plug-in the humidfier,
touch the ON/OFF button, it will start to work.
3. Whenever the machine runs out of water, the machine will automatically turned
off and stop working upon empty tank. To make it work again, pull out the plug and
add water. Do not add in oil.
4. You can change the length of the PVC pipe as you wish.

INTELLIGENT
HUMIDITY

APPOINTMENT ION

Remote Control
A. Open the tank cover.
B. Plug-in the humidfier, press the ON/OFF button and it will start to work.
ELECTRONIC MODEL

ON/OFF Button Plug-in power cable. It will be in standby mode and white light
pop up on the screen, touch the button and the humidifier will start to work in high mode.

Mist Button Press the button 1 time, it will start to work in high mode, all the lights
will turn on. Press the button again and it will be in low mode, 12 lights will turn on. Press
the button again one more time, it will be in middle mode and 20 lights will turn on.

Timer Button Press this button, time can be set from 1 to 16 hours (if there are 2
or more figures on the display, the setting time will be the total sum)

Humidity button Set humidity between 45%-95%. Press this button until it reaches
95%. Press one more time to cancel the setting. Set a certain value and the humidifier will
work accordingly. Whenever the set value of humidity is achieved in the room, the
machine will stop working until the humidity level drops, the tolerance will be around
+-5%, and the constant humidity in the remote control is 70%.

Ion Button When press this button the light will turn on and the ion will be in
working mode. Touch this button again, the light will turn off and this function is cancelled.
Remark: The functions of ion is to clean the air, eliminate secondhand smoke, prevent
electrostatic and so on.

Appointment Button Press this button, the figures on the display will be running
in appointment mode, we can set the time from 0 to 24 hours, once the user completed
the setting, the temperature and setting time will display on the screen. Alternately, if the
time is not set, it will only display the temperature on the screen.

Sleep Button (Night Mode) Hold this button 3 seconds, the machine will enter
sleep mode. The light on the screen will turn off. Other functions are working as normal.
SAFETY INSTRUCTIONS:
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injuries.

1. Do not repair or adjust the product base by yourself.


2. Do not try to replace the power cord when it is broken by yourself, you can
ask our service department to do it.
3. Do not add any kind of additive into the water tank which was not
recommended by us.
4. Keep the humidifier away from the children
5. Any change or refitting without our confirmation may damage the machine.
6. Immediately turn off the humidifier and unplug the power when there is any
abnormal sound or smell, Contact the service department if it needs to be
repaired.
7. Unplug the humidifier when moving or cleaning it.
8. Unplug the humidifier when it is not in use.
9. Do not attempt to empty, fill, and tilt the humidifier while it is working.
10. Do not touch the water or the units in the flume when it is in operation mode.
11. Do not turn on the machine when there is no water inside.
12. Do not use the machine in high humidity atmosphere such as shower room.
13. Do not scrape or scratch the atomization sheet with hard particles.
14. Do not let water run into the inside of the base part.
15. Use the low mode when the temperature is low or the humidity is high in
case the mist could not run out smoothly.
16. In order to save the service life of the machine and avoid accident, place it
in dry place.
17. Place the humidifier on a flat, smooth, level surface.
18. Place the humidifier away from the fire, stove and avoid direct sunlight.
19. Use the machine at room temperature.
20. The mist direction should be aimed away from the walls, electric appliances
and furniture.
GENERAL TROUBLESHOOTING
DO NOT ATTEMPT TO REPAIR THE HUMIDIFIER BY YOURSELF.

Symptoms Reason analysis Solutions

The plug is not connected properly Insert the plug correctly

The power is off Turn on the power


No wind nor mist

No water or little water in the tank Fill enough water

Has scale on the surface of the Clean the atomization sheet


Low mist
atomization sheet or dirty water and change the water.
Open the water tank and let
New machine it open in a steady and cool
Abnormal smell place for 12 hours
Water is not clean or stored in the Clean the tank and change
machine for a long time with clean water
Place the water tank
Water tank is placed incorrectly
correctly
Abnormal sound
Resonance caused by little water
Fill enough water
in the tank
Mist going
Resonance caused by unsteady Put the appliance on a
around the
table steady table
spout

Technical Parameters:
Product Name Bactakleen Ultrasonic Diffuser/Humidifier
Model MVK-2
Voltage 100V-240V~ 50Hz/60Hz
Power 100W
Evaporation 1500ml/h
Capacity 15L
Multiple options, do not include all
accessories, subject to receipt of
the goods in kind

15

16

11

12
13

14

1. Spout
2. Mist Pipe
3. Mist Pipe Joint
4. Water Tank Turn Cover
5. Water Tank Cover
6. Filter
7. Water Tank
8. Floater
9. Wind Window
10. Water Level Sensor
11. Atomization Sheet
12. Display Screen
13. Power Cord
14. Trundle
15. Transparent Water Level Window
16. Protective Jacket for floater,take off the protective jacket before using the machine, otherwise,
the water could not run into the water channel
The way to clear the atomization sheet and base ELECTRONIC MODEL
channel
ON/OFF Button Plug-in power cable. It will be in standby mode and white light
Unplug before cleaning the machine
pop up on the screen, touch the button and the humidifier will start to work in high mode.
Dilute the detergent and pour it into the base by adding 45 C water to dissolve the
detergent. Soak for 10 minutes and gently scrub the surface with a small brush until scale Mist Button Press the button 1 time, it will start to work in high mode, all the lights
is removed. Wash the base with 1:1 of water and white vinegar or citric acid. Then clean
the base and surface with water. will turn on. Press the button again and it will be in low mode, 12 lights will turn on. Press
the button again one more time, it will be in middle mode and 20 lights will turn on.
Product instructions:
1. Do not put anything below the machine, it will affect the air intake. Timer Button Press this button, time can be set from 1 to 16 hours (if there are 2
2. Open the tank cover, add water, close the tank cover, plug-in the humidfier, or more figures on the display, the setting time will be the total sum)
touch the ON/OFF button, it will start to work.
3. Whenever the machine runs out of water, the machine will automatically turned Humidity button Set humidity between 45%-95%. Press this button until it reaches
off and stop working upon empty tank. To make it work again, pull out the plug and
95%. Press one more time to cancel the setting. Set a certain value and the humidifier will
add water. Do not add in oil.
4. You can change the length of the PVC pipe as you wish. work accordingly. Whenever the set value of humidity is achieved in the room, the
machine will stop working until the humidity level drops, the tolerance will be around
+-5%, and the constant humidity in the remote control is 70%.

Ion Button When press this button the light will turn on and the ion will be in

ULTRASONIC DIFFUSER/HUMIDIFIER working mode. Touch this button again, the light will turn off and this function is cancelled.

MODEL: MVK-2 Remark: The functions of ion is to clean the air, eliminate secondhand smoke, prevent
electrostatic and so on.

Appointment Button Press this button, the figures on the display will be running
Daily maintenance
INTELLIGENT
HUMIDITY

in appointment mode, we can set the time from 0 to 24 hours, once the user completed
Keep the machine clean, clean the machine periodically, clean the
the setting, the temperature and setting time will display on the screen. Alternately, if the
limescale and the dust gauze frequently, keep it dry and store it in dry
APPOINTMENT ION

time is not set, it will only display the temperature on the screen.
place. Remote Control
A. Open the tank cover.
Sleep Button (Night Mode) Hold this button 3 seconds, the machine will enter
B. Plug-in the humidfier, press the ON/OFF button and it will start to work.
sleep mode. The light on the screen will turn off. Other functions are working as normal.

SAFETY INSTRUCTIONS: GENERAL TROUBLESHOOTING


When using electrical appliances, basic precautions should DO NOT ATTEMPT TO REPAIR THE HUMIDIFIER BY YOURSELF.
always be followed to reduce the risk of fire, electric shock and
Symptoms Reason analysis Solutions
injuries.
Multiple options, do not include all
The plug is not connected properly Insert the plug correctly accessories, subject to receipt of
1. Do not repair or adjust the product base by yourself. the goods in kind
The power is off Turn on the power
2. Do not try to replace the power cord when it is broken by yourself, you can No wind nor mist
ask our service department to do it.
No water or little water in the tank Fill enough water
3. Do not add any kind of additive into the water tank which was not
recommended by us. Has scale on the surface of the Clean the atomization sheet
Low mist
4. Keep the humidifier away from the children atomization sheet or dirty water and change the water.
5. Any change or refitting without our confirmation may damage the machine. Open the water tank and let
New machine it open in a steady and cool
6. Immediately turn off the humidifier and unplug the power when there is any
Abnormal smell place for 12 hours
abnormal sound or smell, Contact the service department if it needs to be 15
Water is not clean or stored in the Clean the tank and change
repaired. machine for a long time with clean water 16
7. Unplug the humidifier when moving or cleaning it.
Place the water tank ⑩
8. Unplug the humidifier when it is not in use. Water tank is placed incorrectly
correctly
9. Do not attempt to empty, fill, and tilt the humidifier while it is working. Abnormal sound
Resonance caused by little water 11
10. Do not touch the water or the units in the flume when it is in operation mode. Fill enough water
in the tank 12
11. Do not turn on the machine when there is no water inside. 13

12. Do not use the machine in high humidity atmosphere such as shower room. Mist going
Resonance caused by unsteady Put the appliance on a 14
around the
13. Do not scrape or scratch the atomization sheet with hard particles. spout
table steady table
1. Spout
14. Do not let water run into the inside of the base part.
2. Mist Pipe
15. Use the low mode when the temperature is low or the humidity is high in 3. Mist Pipe Joint
case the mist could not run out smoothly. 4. Water Tank Turn Cover
16. In order to save the service life of the machine and avoid accident, place it Technical Parameters: 5. Water Tank Cover
in dry place. Product Name Bactakleen Ultrasonic Diffuser/Humidifier 6. Filter
Model MVK-2 7. Water Tank
17. Place the humidifier on a flat, smooth, level surface.
Voltage 100V-240V~ 50Hz/60Hz 8. Floater
18. Place the humidifier away from the fire, stove and avoid direct sunlight. Power 100W 9. Wind Window
19. Use the machine at room temperature. Evaporation 1500ml/h 10. Water Level Sensor
20. The mist direction should be aimed away from the walls, electric appliances Capacity 15L 11. Atomization Sheet
and furniture. 12. Display Screen
13. Power Cord
14. Trundle
15. Transparent Water Level Window
16. Protective Jacket for floater,take off the protective jacket before using the machine, otherwise,
the water could not run into the water channel

You might also like