features and benefits | ALTOS® Low-Temperature Cables are designed for
extreme cold temperature environments with an extend-
|
Extended operating tem- Allows for operation at
Cables incorporate
an innovative water-
Eliminates the need
for traditional flooding standards |
blocking design compound and provides Telcordia GR-20
|
efficient and craft-friendly
COPPER CONNECTIVITY
cable preparation ICEA-640
SZ-stranded, loose Isolates fibers from instal- RDUP listed (formerly RUS)
tube design lation and environmental
rigors and facilitates
midspan access
|
strength member and requires no bonding
HARDWARE
or grounding
|
CABLE ASSEMBLIES
|
CONNECTORS
PE Jacket
Ripcord
PE Outer Jacket Water-Swellable Tape
|
Corrugated Steel Tape Armor
Buffer Tube (Gel-Filled)
CABLES
Ripcord
Water-Swellable Tape
PE Inner Jacket Fibers
Ripcord (12 fibers per tube)
Water-Swellable Tape
Water-Swellable Yarn
|
PE Jacket
Water-Swellable Tape
Ripcord
Water-Swellable Yarn
Filler
Ripcord
specifications |
Maximum Tensile Loads Short-Term: 2700 N (600 Ibf)
Long-Term: 890 N (200 Ibf)
12-72 12 6 1-6 Dielectric 80 (54) 10.5 (0.41) 15.8 (6.2) 10.5 (4.1)
84-96 12 8 7-8 Dielectric 108 (72) 12.2 (0.48) 18.3 (7.2) 12.2 (4.8)
108-144 12 12 9-12 Dielectric 177 (119) 15.8 (0.62) 23.7 (9.3) 15.8 (6.2)
156-216 12 18 13-18 Dielectric 169 (113) 16.0 (0.63) 24.0 (9.4) 16.0 (6.3)
228-288 12 24 19-24 Dielectric 226 (152) 18.2 (0.72) 27.3 (10.7) 18.2 (7.2)
|
Solutions Product
TRAINING
Low-Temperature ALTOS® Cables, Single-Jacket/Single-Armored, 2-288 Fibers
Designed for Direct-Buried and Aerial Applications
|
SPLICE AND TEST EQUIPMENT
Nominal Nominal
Maximum Number Number Weight Outer Minimum Bend Radius
Fiber Fibers of Tube of Active Central kg/km Diameter Loaded Installed
Count per Tube Positions Tubes Member (lb/1000 ft) mm (in) cm (in) cm (in)
12-72 12 6 1-6 Dielectric 136 (91) 12.1 (0.48) 18.2 (7.1) 12.1 (4.8)
84-96 12 8 7-8 Dielectric 173 (116) 13.8 (0.54) 20.7 (8.1) 13.8 (5.4)
108-144 12 12 9-12 Dielectric 262 (176) 17.5 (0.69) 26.3 (10.3) 17.5 (6.9)
156-216 12 18 13-18 Dielectric 256 (172) 17.7 (0.70) 26.6 (10.5) 17.7 (7.0)
228-288 12 24 19-24 Dielectric 323 (217) 20.0 (0.79) 30.0 (11.8) 20.0 (7.9)
|
COPPER CONNECTIVITY
Low-Temperature ALTOS Cables, Double-Jacket/Single-Armored, 2-288 Fibers
Designed for Direct-Buried Applications
Nominal Nominal
Maximum Number Number Weight Outer Minimum Bend Radius
Fiber Fibers of Tube of Active Central kg/km Diameter Loaded Installed
Count per Tube Positions Tubes Member (lb/1000 ft) mm (in) cm (in) cm (in)
|
12-72 12 6 1-6 Dielectric 179 (120) 14.3 (0.56) 21.5 (8.4) 14.3 (5.6)
HARDWARE
84-96 12 8 7-8 Dielectric 219 (147) 16.0 (0.63) 24.0 (9.4) 16.0 (6.3)
108-144 12 12 9-12 Dielectric 318 (213) 19.7 (0.78) 29.6 (11.6) 19.7 (7.8)
156-216 12 18 13-18 Dielectric 312 (209) 19.9 (0.78) 29.9 (11.8) 19.9 (7.8)
228-288 12 24 19-24 Dielectric 384 (257) 22.2 (0.87) 33.3 (13.1) 22.2 (8.7)
|
transmission performance |
CABLE ASSEMBLIES
Fiber Code K T E E
|
CONNECTORS
ISO/IEC 11801 OM1 OM2 OS2 OS2
Nomenclature
U - T 1 C 2 0
|1 |2 |3 |4 |5 |6 |7 |8 |9 |10 |11 |12 |13 |14
|1-3 |5 / 12 |7 |10-11
Select fiber count. Defines cable type. Defines fiber placement. Select performance
(012-288, increments of 12) U / C = ALTOS® Low- T = 12 fiber/buffer tube option code
Temperature Cable (standard) (see Transmission
|4 |6 |8
Performance table).
|9
20 = No special requirements
single armored
See Note 1.
Note:
Defines tensile strength. 1) See specifications section
1 = 2700 N/600 lb (standard) for application.