Professional Documents
Culture Documents
Material Specification & Test
Material Specification & Test
Specification
1. MS Plates
Material specfication ASTM A 572 /Q345B/
MS build up section Fy = 345 MPa (50 ksi)
Grade 50
Din 933 Gr8.8 HDG Fu = 800 Mpa (116 ksi)
High strength bolt
(or equivalent) Ft = 640 Mpa (92.8 ksi)
ASTM A36
Anchor bolt Fy = 248 Mpa (36 ksi)
(or equivalent)
ASTM A307‐03
Shear stud Fy = 345 MPa (50 ksi)
(or equivalent)
2. Concrete
3. Cement
Standard BS EN 196
4. Reinforcement
Type Standard Minimum yield strength
60 Grade ASTM A615 60000 psi
Test for Materials
Component/
Test Name Remarks
Material Name
Pilot Pile should be conducted adjucent
1. Static Pile Load Test to the site and loaded upto 400 MT
Pile static load
2. Pile Integrity Test Test should be conducted for all piles
Test (7 & 28 days) should be conducted
for every types of casting at below
mentioned frequency.
For,
i. Pile: 2 set per 100 cum of casting
ii. Pile‐cap: 2 set per 100 cum of casting
1. Compressive Strength Test
iii. Grade beam: 2 set per 200 cum of
casting
iv. Column & RC wall: 2 set per 100 cum
of casting
v. Floor Beam, Deck Slab, Grade Slab &
Concrete
Stair: 2 set per 200 cum of casting
Test should be conducted for every
RMC delivery truck at site.
2. Slump Test For,
i. Pile: Slump value = 200mm
ii. Other casting : Slump value = 125mm
Mix design of casting for desired
3. Mix Design strength should be provided by
contractor
1 set per 50 MT of Reinforcement of
Rebar Yield and Ultimate Strength Test
every particular diameter
1. Compressive Strength Test (7 Days)
Frequency as per compressive strength
Cement 2. Setting time test
test of concrete
3. Finness test
1. Fineness Modulus (F.M.) Test
Sand of F.M. ≥ 2.5 should be ensured for
Sand 2. Salinity Test
desired strength by contractor
3. Gradation Test
Component/
Test Name Remarks
Material Name
1. Los Angeles Abrasion Test Los Angeles Abrasion value should be <
Stone Chips 25 which should be confirmed by
2. Gradation Test contractor
1. Setting Time Test (ASTM C953)
3. Volume Change Test (ASTM C1090)
Test should be conducted for every
types of thickness at below mentioned
frequency.
MS Plate (Flange, Web,
For,
Connection Plate, Joint Plate Tension Test
i. Column: 1 set per 100 MT
etc.)
ii. Main‐Beam: 1 set per 100 MT
iii. Secondary Beam: 1 set per 100 MT
iv. Joist Beam: 1 set per 200 MT
Test should be conducted for 2 set per
Deck Sheet Tension Test
floor
Test should be conducted for 2 set per
Nut Bolt Shear Test & Tension Test
each diameter of bolt per floor
Test should be conducted for 2 set per
Shear Bolt Shear Test
floor
Test should be conducted at below
mentioned locations of every structural
components:
Welding UT Test 1. Butt Joint
2. End Plate Joint
3. Baseplate & Column Joint
4. Web/Flange Connection