Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Materials 

Specification

1. MS Plates

Component Specification Minimum Yield Strength

Material specfication ASTM A 572 /Q345B/ 
MS build up section Fy = 345 MPa (50 ksi)
Grade 50

Deck pannel ASTM A792/ Grade 43.5 : Coating AZ150 Fy = 300 MPa (43.5 ksi)

Din 933 Gr8.8 HDG  Fu = 800 Mpa (116 ksi)
High strength bolt
(or equivalent) Ft = 640 Mpa (92.8 ksi)
ASTM A36
Anchor bolt Fy = 248 Mpa (36 ksi)
(or equivalent)
ASTM A307‐03
Shear stud Fy = 345 MPa (50 ksi)
(or equivalent)

2. Concrete

Component Specification Minimum Compressive Strength

Pile M28 4000 psi

Pile Cap M34.50 5000 psi

Retaining wall M34.50 5000 psi

Column M34.50 5000 psi

Lift core & Shear wall M34.50 5000 psi

Stair M28 4000 psi

Beam & Slab M28 4000 psi

Non‐shrink Grout Class A 5000 psi

3. Cement
Standard BS EN 196

4. Reinforcement
Type  Standard Minimum yield strength
60 Grade ASTM A615 60000 psi
Test for Materials

Component/
Test Name Remarks
Material Name

Pilot Pile should be conducted adjucent 
1. Static Pile Load Test  to the site and loaded upto 400 MT 
Pile static load 

2. Pile Integrity Test Test should be conducted for all piles

Test  (7 & 28 days) should be conducted 
for every types of casting at below 
mentioned frequency. 
For, 
i. Pile: 2 set per 100 cum of casting
ii. Pile‐cap: 2 set per 100 cum of casting
1. Compressive Strength Test
iii. Grade beam: 2 set per 200 cum of 
casting
iv. Column & RC wall: 2 set per 100 cum 
of casting
v. Floor Beam, Deck Slab, Grade Slab & 
Concrete
Stair: 2 set per 200 cum of casting 

Test should be conducted for every 
RMC delivery truck at site.
2. Slump Test For,
i. Pile: Slump value = 200mm
ii. Other casting : Slump value = 125mm

Mix design of casting for desired 
3. Mix Design strength should be provided by 
contractor

1 set per 50 MT of Reinforcement of 
Rebar Yield and Ultimate Strength Test
every particular diameter

1. Compressive Strength Test (7 Days)
Frequency as per compressive strength 
Cement 2. Setting time test
test of concrete
3. Finness test

1. Fineness Modulus (F.M.) Test
Sand of F.M. ≥ 2.5 should be ensured for 
Sand  2. Salinity Test
desired strength by contractor
3. Gradation Test
Component/
Test Name Remarks
Material Name

1. Los Angeles Abrasion Test  Los Angeles Abrasion value should be < 
Stone Chips 25 which should be confirmed by 
2. Gradation Test contractor

1. Setting Time Test (ASTM C953)

Non‐shrink Grout 2. Cube Strength Test (ASTM C942) Test should be conducted for 1 set

3. Volume Change Test (ASTM C1090)

Test should be conducted for every 
types of thickness at below mentioned 
frequency. 
MS Plate (Flange, Web, 
For, 
Connection Plate, Joint Plate  Tension Test
i. Column: 1 set per 100 MT
etc.)
ii. Main‐Beam: 1 set per 100 MT
iii. Secondary Beam: 1 set per 100 MT
iv. Joist Beam: 1 set per 200 MT

MS Plate (Base Plate) Tension Test Test should be conducted for 3 set

Test should be conducted for 2 set per 
Deck Sheet Tension Test
floor

Anchor Bolt Shear Test & Tension Test Test should be conducted for 2 set 

Test should be conducted for 2 set per 
Nut Bolt Shear Test & Tension Test
each diameter of bolt per floor

Test should be conducted for 2 set per 
Shear Bolt Shear Test
floor

Test should be conducted at below 
mentioned locations of every structural 
components:
Welding UT Test 1. Butt Joint
2. End Plate Joint
3. Baseplate & Column Joint
4. Web/Flange Connection

Bearing Capacity of Soil Field Density Test Compaction value  ≥ 95% 