Storage and Hyper-V Part 7: Actual Performance

www.altaro.com/hyper-v/storage-and-hyper-v-part-7-actual-performance-2/

March 18, 2014

18 Mar 2014 by Eric Siron

Rate

This series has meandered down a long and winding path


from basic concepts to theory to practice. In this final installment, I’m going to show a lot of
really boring graphs and charts to answer the big question: What about performance?

Part 1 – Hyper-V storage fundamentals


Part 2 – Drive Combinations
Part 3 – Connectivity
Part 4 – Formatting and file systems
Part 5 – Practical Storage Designs
Part 6 – How To Connect Storage
Part 7 – Actual Storage Performance

I think what people really want to know is, out of all the various ways storage can be
configured, what’s going to provide the best performance? I will, as always, caution against
being that person with an unhealthy obsession with performance. I’ve met too many
individuals who will stress over an extra millisecond or two of latency in a system where no
one will think anything is wrong unless the delay passes several seconds. If you truly need
ridiculously high storage speed and you are not already a storage expert, hire one.

Introduction
What I’m going to do in this post is show you performance results that were all taken from
the exact same hardware configured in several different ways. The test was configured
exactly the same way each time. What I want you to understand from that is that the
numbers themselves are largely irrelevant. The hardware that I used is not up to the
challenges of anything more than a small business environment, and by small, I mean
something like under twenty users. What’s important is how the numbers do or do not
compare against each other across the various test types.

Materials and Methods


1/6
This section lists the hardware, software, and configurations used in the tests.

Hardware
3x Hewlett-Packard N40L MicroServers with firmware 2013.10.01. With the exception of
the hard drives, all hardware is configured as indicated in our sub-$2000 build paper.

In the server used as the storage server, two Seagate ST3000DM001 drives were added to
the defined configuration. These were placed into a mirror Storage Spaces array.

Although it should not have impacted the test outcomes, both of the Hyper-V systems were
expanded so that their internal drives are in a hardware RAID-1 configuration. No test was
run from these drives.

The hardware switch used is the Netgear GS716T device indicated in the document, with
firmware version 5.4.1.10.

This test used a virtual machine running Windows Server 2012 R2 Standard Edition in
evaluation mode, build 6300.

Software
The virtual machine used in testing was running Windows Server 2012 R2 Standard
Edition, evaluation build 9600. All Windows Server patches were current as of February
10th, 2014.

The testing software used was IOMeter version 1.1.0 RC1.

The storage host is running Windows Storage Server 2012 R2 Standard Edition, same
build and patch level as the guest.

The two Hyper-V hosts are running Hyper-V Server 2012 R2, same build and patch level as
the guest.

No out-of-band hotfixes were applied to any system; only those available through Windows
Updates were applied.

Configuration
The test virtual machine was a generation 1 machine assigned 2 virtual CPUs and 2GB of
RAM. Its C: drive was a dynamically expanding drive with a limit of 60 GB. This drive was
placed on separate storage from the test volume. The test volume was attached to the
virtual SCSI chain and set to 260 GB in size. It was dynamic in some tests but converted to
fixed for others. The type used will be reported in each test result. Both disks were in the
VHDX format.

The IOMeter test was configured as follows:

Only one worker was allowed.


The Maximum Disk Size was set to 65,536,000 on a disk with 4k sector size and
524,288,000 on disks with a 512b sector size; this results in a 250GB test file.

2/6
A single Access Specification was designed and used: 16K; 75% Read; 50%
Random
The Test Setup was limited to a 30 minute run
Results and configurations were saved on the virtual machine’s C: drive for tests run
inside the VM
All other settings were kept at default

Download the IOMeter ICF. (the current version doesn’t actually allow import of saved ICF
files, but it is human-readable)

The hosts were configured as follows:

Onboard (Broadcom NetXtreme I) adapters were left strictly for management


All other adapters in the Hyper-V nodes (4x Realtek) were fully converged in LACP
with Dynamic load-balancing in most tests
Some tests, indicated in the text, broke the teams so that each node had 2x
Realtek in a Dynamic load-balancing configuration passing all traffic besides
management and storage. 2x Realteks were assigned their own IPs and
participated directly in the storage network.
The Realtek adapters do not support VMQ or RSS
The two Hyper-V nodes communicated with the storage server using 2 vNICs
dedicated to storage communications on a specific VLAN.
MPIO was enabled across the nodes’ storage NICs for iSCSI access. SMB
multichannel was in effect for SMB tests. This was true in both vNIC and pNIC
configurations. The MPIO method was the default of round-robin.
The two other adapters in the storage node (2x Realtek) were assigned a distinct IP
and placed into the VLAN dedicated to storage
The two Hyper-V nodes were joined into a failover cluster

Target configuration notes:

All tests were conducted against data on the 3 TB Storage Space


Between tests, data was moved as necessary to keep the test file/VHDX as close to
the start of the physical drive as possible.
No other data was on the disk beyond the MFT and other required Windows data.
iSCSI target was provided by the built-in iSCSI Target of Windows Storage Server
2012 R2
SMB 3.02 access was also provided by the built-in capability of Windows Storage
Server 2012 R2

Configuration Notes
Hardware RAID-1 would have been preferred for the 3 TB Seagate drives, but the onboard
RAID array cannot work with disks that large. It is possible that the extra CPU load
negatively impacted the local test in a way that would not have impacted any of the remote
tests. There was no way to control for that with the available hardware.

3/6
A truly scientific test would include more hardware variance than this. The switch presents
the major concern, because another switch was not available to rule out any issues that
this one might have.

Results
The following charts show a graphical representation of the results of each test.

The first shows all results together in a single combined view:

The next three show the individual


result sets.

Download the cumulative test results


in Excel format. Each tab in the Excel
workbook represents one test. All
IOMeter results are contained here,
not just the three metrics listed above.

Composite Results

IOPS Comparison

Megabytes per Second Comparison

4/6
Average Response Time Comparison

Discussion
With the low-end nature of the hardware, the variances of these results are more
pronounced than they would be in higher-end hardware.

RSS support would likely have made a substantial difference.

There are a couple of things to be aware of when scanning the results. First, the “Local
Disk, No VM” result was performed right on the empty Storage Space. This space uses 4k
sector sizes. The virtual machine’s VHDX sets its cluster size to 512 bytes. This alone
affected the outcome in a way that makes all the other tests look like the difference
between virtual and physical is more dramatic than it is.

The test configuration presents a very difficult case for hard disks. Larger chunk sizes result
in better performance. The chunk size was chosen arbitrarily, but can’t be used to predict
real-world performance even with the same hardware. The goal was to use a single size to
reduce variance across the tests. The 75% read percentage was chosen as most real-
world operations are read-heavy. The breakdown of read vs. write performance can be
found in the download results file.

Most of the remote tests had a few moments of very high delays that skewed the total
results negatively. I wasn’t able to determine if these delays were legitimate, as they
recorded lengths of sometimes approaching two minutes. They always occurred in the first
couple of minutes of each remote test and then never again. Usually by the end of each
test, the numbers had settled.

Obviously, not all possible permutations were tested, primarily due to time constraints.
However, speeds increased substantially when the fully converged design was split out and
two physical NICs were designated for storage communications.

For the “contention” test, another VM was running the same IOMeter load on the other node
against the same CSV while data was collected on the test VM. Notice how little that affects
the outcome.

Conclusion

5/6
Raw hardware access is always the fastest possible configuration. However, higher-end
hardware would not experience the wide range of differences and would bring offloading
technologies and optimizations that would close the gap. Local access is, as expected,
faster than over-the-network access.

One thing the results are pretty unambiguous about is that dedicated physical NICs work
better for storage communications than virtual NICs on a converged fabric. Again, higher-
end hardware would reduce this impact dramatically.

It also appears that running on a non-owner node has an effect. Unfortunately, with a test
group this small, there’s no way to be certain that there wasn’t a network issue. This
warrants further study.

The multichannel SMB configuration showed that it performs better than an iSCSI
configuration, all else being equal. This would also eliminate the penalty imposed by
running on a non-CSV owner node.

The difference between the dynamic and fixed SMB results was surprisingly wide. This
disparity warrants further study.

Download: Free Hyper-V Backup


Download your FREE copy of Altaro VM Backup, Altaro's easy to use backup software for
Hyper-V trusted by 40,000+ organizations worldwide. FREE, forever for up to 2 VMs per
host

Download Now!Learn more

Get notified about new articles by email


Receive all our free Hyper-V articles and checklists and get notified firstwhen we release
new eBooks and announce upcoming webinars!

Eric Siron
I have worked in the information technology field since 1998. I have
designed, deployed, and maintained server, desktop, network, and
storage systems. I provided all levels of support for businesses ranging
from single-user through enterprises with thousands of seats. Along
the way, I have achieved a number of Microsoft certifications and was
a Microsoft Certified Trainer for four years. In 2010, I deployed a
Hyper-V Server 2008 R2 system and began writing about my
experiences. Since then, I have been writing regular blogs and
contributing what I can to the Hyper-V community through forum participation and free
scripts.