Professional Documents
Culture Documents
B C D E F G A D E: Ground Floor Plan Hvac
B C D E F G A D E: Ground Floor Plan Hvac
B C D E F G A D E: Ground Floor Plan Hvac
D1 E1
EXISTING BRIDGE
#401 - 134 Abbott Street, Vancouver, BC, V6B 2K4
NEW ASPHALT PATH
t: 604-683-5060 e: info@urban-arts.ca
DECK
SOFT LANDSCAPING
1 SEAL:
W 200.4
5
0.
20
W
SKY LIGHT EXISTING - SEE
ABOVE ENVELOPE DWGS
2
HB
D 200.1
MW200.3
SHELVING
PAC
BIKE RACKS EDGE OF CONC
FOUNDATION TO ALIGN
WITH OVERHANG
NOTES:
ABOVE
STORAGE This drawing is the property of Urban Arts Architecture and may
WRECK ROOM SHELVING not be reproduced without their permission and unless the
BULKHEAD ABOVE
reproduction carries their name. All designs and all other
information shown on this drawing are for use on the specified
project only and shall not be used otherwise without written
permission of this office.
203
D 203.1
SHELVING
20" X 24" DUCT BOOK RETURN ENTRY PLAZA The Contractor shall check and verify all dimensions and report
201 UNIT PAVERS any discrepancies before proceeding.
STORAGE
Do not scale drawings.
MW201.1
PORT ROOM ROYAL ROOM
G
SHELVING
TIN
IS
W 200.3
EX
F
O ING
E
D 201.1 N D
LI UIL
MW200.3
B
BULKHEAD ABOVE
SHELVING
PAC
CANOPY ABOVE
KEYNOTES
MW200.2
STORAGE FILL IN P
LINE OF EXPOSED
WINDOW EXISTING
BEAMS ABOVE
W 200.2
STRUCTURAL
INFO DESK
MW200.1
COLUMNS
LINOLEUM 200
STORAGE LIBRARY
SKY LIGHT
ABOVE
3
SHELVING
CHECK
W 200.1
NOTICES
SF202.1
D 202.1
202 SHELVING
STUDY RM PERMANENT ENTRANCE
MAT C/W DRAIN
ELECTRICAL PANEL D 101.1 NOTICES
CHECK CHECK
OUT OUT
D 100.1
SHELVING UNIT PAVERS
CW 100.1 CONCRETE BASIN
MW200.3
4
SF 101.1
D 100.2
SHUTTER
CW 100.2
OVER VESTIBULE 1
LOBBY
FOOT GRILLE
LINE OF
SHUTTER
ABOVE
5
NOTICES
BRACE BAY
Y
TELEPHONE ROOM JANITORIAL
E BA
ROOM
BRAC
HALL
FILL IN
EXISTING OPEN TO
OPENING ABOVE PA
306 307
SERVER 308
305 STORAGE
MECH ROOM #1 EL 100.0 FLEX OFFICE
WEST CORRIDOR
F
6
NOTICES
HW 103 EXIT1 U/C
FR
DW
25 RISERS @ 7-1/8"
ATRIUM
23 TREADS @ 11"
309 ELECTRICAL PANEL
STAFF WC
BRACE BAY
WOMEN'S EXIT TO 310
LOCKERS
CHANGE LANDING
STAFF RM
ATRIUM WHITE BOARD
ROOM SERVERY
BENCH
GYM
HOOKS
311
312 FLEX OFFICE
LINE OF EXISTING MEETING RM
U/C U/C
FRIDGE FREEZER DW
401 HB
BULKHEAD
ABOVE SLIDE COMMUNITY KITCHEN
PANTRY
OUT-GATE
TV MONITOR GAT
7
E
BRACE BAY
STORAGE CLOSET
MACHINES
VENDING
(N.I.C)
MEETING
ROOM
BENCH
NEW OPENING ADD NEW
IN GYM WALL DOORS IN PAVERS
EXIST. WALL 400 REFER TO
LANDSCAPE
71
MULTI-PURPOSE 1
P4B
FD
112 111 108 P3
ELEVATOR
MEN'S FD
P4B
LOCKER FD STORAGE
ROOM 107 EL 100.0
P4B
WOMENS WC
BRACE BAY
PERMANENT
FRIDGE EDGE OF ENTRANCE
FD CONCRETE MAT C/W DRAIN
507 402
EADS 7-1/8"
506 ELECTRICAL PANEL
"
@ 11
STORAGE
22 TR ERS @
CHILD CARE SERVERY MULTI-PURPOSE 2
NOTICES
NOTICES
24 RIS
505 106
504 105
ADULT WC FD FAMILY WC FD
STORAGE CLOSET EXIT 2
GATE GATE FD JANITOR
CHILD WC
CHANGE 104
NOTICE
W/D
TABLE
LINE OF
VESTIBULE 2
FOOT GRILLE
SECURITY NOTICES
SIGN IN
LINE OF BULK
SCREEN
HEAD ABOVE
500
9
ISSUED
BRACE BAY
PAVERS
503 REFER TO
LANDSCAPE
CHILD CARE ACTIVITY ROOM
25 501
24 OFFICE HB
STOR
1
23
2
22
BRAC
AGE
3
4
502 21
0
CLOS
CUBBIES 2 9 E BA
Y
E
5 BRAC EDGE OF
BAY
1
6 CONCRETE
ET
FOUNDATION
7
8
9
10
17 18
11 15 16
13 14
13B
GROUND
FLOOR PLAN
HVAC
13A
t: 604-683-5060 e: info@urban-arts.ca
NOTES:
The Contractor shall check and verify all dimensions and report
any discrepancies before proceeding.
50-10-346
KEYNOTES
EDGE OF
CONCRETE
:iDate :iNote
ISSUED
NOTE:
REFER TO SCHEMATIC DRAWINGS
FOR PIPE SIZES AND DETAILS.
SECOND
FLOOR PLAN
HVAC
M-2
A B C D E F G H
D1 E1
EXISTING BRIDGE
#401 - 134 Abbott Street, Vancouver, BC, V6B 2K4
NEW ASPHALT PATH
t: 604-683-5060 e: info@urban-arts.ca
DECK
SOFT LANDSCAPING
SEAL:
W 200.4
5
0.
20
W
SKY LIGHT EXISTING - SEE
ABOVE ENVELOPE DWGS
2
HB
D 200.1
MW200.3
SHELVING
PAC
BIKE RACKS EDGE OF CONC
FOUNDATION TO ALIGN
WITH OVERHANG
NOTES:
ABOVE
STORAGE This drawing is the property of Urban Arts Architecture and may
WRECK ROOM SHELVING not be reproduced without their permission and unless the
BULKHEAD ABOVE
reproduction carries their name. All designs and all other
information shown on this drawing are for use on the specified
project only and shall not be used otherwise without written
permission of this office.
203
D 203.1
SHELVING
20" X 24" DUCT BOOK RETURN ENTRY PLAZA The Contractor shall check and verify all dimensions and report
201 UNIT PAVERS any discrepancies before proceeding.
STORAGE
Do not scale drawings.
MW201.1
PORT ROOM ROYAL ROOM
G
SHELVING
TIN
IS
W 200.3
EX
F
O ING
E
D 201.1 N D
LI UIL
MW200.3
B
BULKHEAD ABOVE
SHELVING
PAC
CANOPY ABOVE
MW200.2
STORAGE FILL IN P
LINE OF EXPOSED
WINDOW EXISTING
BEAMS ABOVE
W 200.2
STRUCTURAL
INFO DESK
MW200.1
COLUMNS
LINOLEUM 200
STORAGE LIBRARY
SKY LIGHT
ABOVE
3 CHECK
SHELVING
W 200.1
NOTICES
SF202.1
D 202.1
202 SHELVING
STUDY RM PERMANENT ENTRANCE
MAT C/W DRAIN
ELECTRICAL PANEL D 101.1 NOTICES
CHECK CHECK
OUT OUT
D 100.1
SHELVING UNIT PAVERS
CW 100.1 CONCRETE BASIN
MW200.3
4
SF 101.1
D 100.2
SHUTTER
CW 100.2
OVER VESTIBULE 1
LOBBY
FOOT GRILLE
LINE OF
SHUTTER
ABOVE
5
NOTICES
BRACE BAY
Y
TELEPHONE ROOM JANITORIAL
E BA
ROOM
BRAC
HALL
FILL IN
1. ALL UFH PIPE IS hePEX CROSS-LINKED EXISTING OPEN TO
OPENING ABOVE PA
POLYETHYLENE c/w INTEGRAL OXYGEN DIFFUSION
BARRIER, UNLESS NOTED OTHERWISE. 306 307
SERVER 308
305 STORAGE
2. THE SYSTEM IS TO BE PRESSURIZED TO AT MECH ROOM #1 EL 100.0 FLEX OFFICE
WEST CORRIDOR
F
6
NOTICES
HW 103 EXIT1 U/C
FR
DW
25 RISERS @ 7-1/8"
3. CONTRACTOR TO MEASURE AND RECORD ATRIUM
23 TREADS @ 11"
ACCURATE LENGTHS OF UNDER FLOOR PIPING 309 ELECTRICAL PANEL
DURING INSTALLATION FOR BALANCING PURPOSES. STAFF WC
BRACE BAY
4. ALL UNDERSLAB HEATING PIPING RUNNING BELOW WOMEN'S EXIT TO 310
LOCKERS
CHANGE LANDING
STAFF RM
SLAB IN THE CORRIDOR AREAS MUST BE INSULATED ROOM
ATRIUM WHITE BOARD
SERVERY
WITH 12mm THICK ARMOURFLEX INSULATION BEFORE
BENCH
GYM
HOOKS
CONCRETE IS POURED. 311
312 FLEX OFFICE
LINE OF EXISTING MEETING RM
5. ANCHOR ALL PIPES SO THEY DO NOT MOVE
DURING CONCRETE POUR. ANY DAMAGED U/C U/C
FRIDGE
INSULATION MUST BE REPLACED BEFORE CONCRETE FREEZER DW
POUR. 401 HB
BULKHEAD
ABOVE SLIDE COMMUNITY KITCHEN
6. UNDERFLOOR PIPING IN ALL PERIMETER AREAS TO
PANTRY
OUT-GATE
TV MONITOR GAT
7
MACHINES
7. SHOP DRAWINGS TO INCLUDE COMPLETE LOOPS
VENDING
LAYOUT AND CALCULATION FOR CONSULTANT
(N.I.C)
REVIEW.
MEETING
ROOM
BENCH
NEW OPENING ADD NEW
IN GYM WALL DOORS IN PAVERS
EXIST. WALL 400 REFER TO
LANDSCAPE
71
MULTI-PURPOSE 1
KEYNOTES P4B
FD
112 111 108 P3
ELEVATOR
MEN'S FD
P4B
LOCKER FD STORAGE
ROOM 107 EL 100.0
P4B
WOMENS WC
BRACE BAY
PERMANENT
FRIDGE EDGE OF ENTRANCE
FD CONCRETE MAT C/W DRAIN
507 402
EADS 7-1/8"
506 ELECTRICAL PANEL
"
@ 11
STORAGE
22 TR ERS @
CHILD CARE SERVERY MULTI-PURPOSE 2
NOTICES
NOTICES
24 RIS
505 106
504 105
ADULT WC EXIT 2
STORAGE CLOSET
GATE GATE
FD
FD FAMILY WC FD
JANITOR
CHILD WC
104
NOTE: CHANGE
NOTICE
W/D
TABLE
VESTIBULE 2
REFER TO SCHEMATIC DRAWINGS LINE OF
SECURITY NOTICES
FOOT GRILLE
SIGN IN
LINE OF BULK
FOR PIPE SIZES AND DETAILS. HEAD ABOVE
SCREEN
500
9
ISSUED
BRACE BAY
NOTE: PAVERS
INSTALLATION OF RADIANT FLOOR 503 REFER TO
LANDSCAPE
CHILD CARE ACTIVITY ROOM
HEATING PIPES IS TO BE 25 501
24 OFFICE
COORDINATED WITH GENERAL HB
STOR
1
23
2
CONTRACTOR AND TO BE 22
BRAC
AGE
3
502 21
INSTALLED AFTER ERECTION OF 4
0
CLOS
CUBBIES 2 9 E BA
Y
E BA
5
1 BRAC EDGE OF
INTERIOR PARTITION WALLS 6 CONCRETE
Y
ET
FOUNDATION
7
PRIOR TO POURING OF CONCRETE 8
9
TOPPING. 10
17 18
11 15 16
13 14
13B
GROUND
FLOOR PLAN
HVAC - PIPING
13A
D1 E1
t: 604-683-5060 e: info@urban-arts.ca
1 SEAL:
SKYLIGHT SKYLIGHT
2
NOTES:
AHU.
SEE
MECH
SLOPE TO
DRAIN
NEW GLAZED
SKYLIGHT
3
OVERFLOW
SCUPPER
SCUPPER DRAIN
4
50-10-346
SKYLIGHT
5
EXISTING ROOF
SLOPED MEMBRANE
ROOF
SLOPE TO DRAIN SLOPED @ 1:12
KEYNOTES
7
LOW SLOPE
RD
MEMBRANE ROOF
SLOPED TO DRAIN 2% MIN.
HEAT PUMP
SEE MECH
8
RD
RD RD
OVER FLOW
SCUPPER OVER
FLOW
ERV. SEE MECH SCUPPER
FITNESS TERRACE
BELOW
RD
9
:iDate :iNote
RD
OVER
FLOW
SCUPPER
13B
LINE OF BUILDING
BELOW ROOF
PLAN
HVAC
13A
M-4
E F
20mm (3/4") BYPASS #401 - 134 Abbott Street, Vancouver, BC, V6B 2K4
20mm (3/4") FROM
BUILDING COLD WATER t: 604-683-5060 e: info@urban-arts.ca
20mm (3/4") TO SYSTEM
FLOW
6 SEAL:
NOTES:
FLOW INDICATOR
This drawing is the property of Urban Arts Architecture and may
not be reproduced without their permission and unless the
reproduction carries their name. All designs and all other
25x25x25x25 CROSS information shown on this drawing are for use on the specified
project only and shall not be used otherwise without written
BOILER HOT SIDESTREAM permission of this office.
WATER SUPPLY MICRON FILTER 20mm (3/4") CROSS The Contractor shall check and verify all dimensions and report
RISER
LOW WATER CUTOFF POT FOR OPTIONAL any discrepancies before proceeding.
FEEDER CORROSION TEST
MCDONNELL & MILLER Do not scale drawings.
COUPON
NO. 63M, 50 PSI W.P.,
FLOW
MANUAL RESET
DRAIN
FUNNEL DRAIN
DETAIL LOW WATER CUTOFF PIPING POT FEEDER AND MICRON FILTER
N.T.S. M/SD #2018
N.T.S. M/SD #1010
NOTE:
REFER TO SCHEMATIC DRAWINGS
FOR PIPE SIZES AND DETAILS.
50-10-346
KEYNOTES (SCHEMATIC)
SYSTEM PIPING
- SCHEDULE 40 BLACK STEEL PIPE ASTM SPECIFICATION A-53.
- CLASS 125 CAST IRON SCREWED FITTINGS ANSI B16.4.
- SCHEDULE 40 WROUGHT STEEL BUTT WELD FITTINGS ANSI B16.9.
M/SD #2014
MECHANICAL
ROOM LAYOUT
HOT/CHILLED WATER PIPING SCHEMATIC HVAC
NTS
M-5
#401 - 134 Abbott Street, Vancouver, BC, V6B 2K4
t: 604-683-5060 e: info@urban-arts.ca
SEAL:
NOTES:
The Contractor shall check and verify all dimensions and report
any discrepancies before proceeding.
50-10-346
:iDate :iNote
ISSUED
MECHANICAL
EQUIPMENT
SCHEDULES
M-6
40mm x 40mm x 6mm
(1-1/2x1-1/2"x1/4")
ANGLE (GALVANIZED)
BRACKET BY MECHANICAL
SUBCONTRACTOR. HEIGHT
TO SUIT
#401 - 134 Abbott Street, Vancouver, BC, V6B 2K4
22 GA. GALV.
POCKET t: 604-683-5060 e: info@urban-arts.ca
150mm (6") MIN.
PITCH FILL BY ROOFING
B.U.R. RIGID INSUL. CONTRACTOR
1/4 x DIA. MIN. 150mm (6") FIBERGLASS
ROOF DECK FLASHING
INSULATION. SEAL:
1.5 HR. "ULC" RATED SIZE OF
D (VOLUME DAMPER)
FIRE DAMPER DIFFUSER
16 GAUGE
SEAL JOINTS BETWEEN
RETAINING ANGLES DIA. INSULATION SHIELD.
2 TYPES OF INSULATION
WITH MASTIC COMPOUND. CALCIUM SILICATE
DUCT SLEEVE
150mm x150mm x 6mm INSULATION OR SIMILAR
(6"x6"x1/4") STEEL PLATE NON-COMPRESSIBLE
INSULATION.
DUCT WELDED TO ANGLE AND
BOLTED TO ROOF DECK BY
TYPICAL ROUND BRANCH DUCT TAKE-OFF
N.T.S. M/SD #3007
MECHANICAL SUBCONTRACTOR
PITCH POCKETS FOR GUY WIRE BRACKETS AND MAIN DUCT This drawing is the property of Urban Arts Architecture and may
WALL OR FLOOR not be reproduced without their permission and unless the
ROOF DUCT SUPPORTS reproduction carries their name. All designs and all other
information shown on this drawing are for use on the specified
N.T.S. M/SD #6005 project only and shall not be used otherwise without written
AIR
permission of this office.
FLOW
DETAIL OF FIRE DAMPERS IN DUCTS The Contractor shall check and verify all dimensions and report
any discrepancies before proceeding.
MOUNTED EQUIPMENT
N.T.S. M/SD #6005
50-10-346
RETURN
MAIN
A.A.V.
RETAINING ANGLES
ISOLATING VALVE
FORCE FLOW UNIT CONDENSATE TRAP DETAIL
DETAIL OF TRANSFER GRILLES DETAIL OF WALL TRANSFER GRILLES (CHECK PLANS & SPECS.
AQUASTAT
N.T.S. M/SD #8013
N.T.S. M/SD #3012 FOR CABINET ARRANGEMENT
N.T.S. M/SD #3012B DRAIN VALVE
DUCTS THROUGH ROOF 16 GAUGE BLACK STEEL 230 NOTE: MOUNTING DETAILS TO BE ADJUSTED AS
(9")
N.T.S. M/SD #6002 ALL WELDED
CONSTRUCTION EXHAUST
22 GAUGE GALV. STEEL HEAT
SHIELD SPACED OUT 25mm (1")
REQUIRED TO SUIT MAKE OF EQUIPMENT
SECTION THROUGH ROOF CURB SHOWING
DUCT FROM FAN DOWN
TO STAINLESS STEEL
FROM COMBUSTIBLE ON NON-
COMBUSTIBLE SPACERS DETAIL OF SPUN ALUMINUM TYPE EXHAUST STACK AND FLASHING
KITCHEN EXHAUST DUCT. N.T.S. M/SD #6009
NOTE: MOUNTING DETAILS TO BE ADJUSTED AS
REQUIRED TO SUIT MAKE OF EQUIPMENT
ROOF EXHAUST FANS
N.T.S. M/SD #6001
M-7
GALVANIZED SHEET METAL HOOD
SEE SPECS FOR c/w 50mm RIGID FIBERGLASS
PIPING OUTSIDE INSULATION ON INSIDE.
BLDG. CONSTRUCTION 150mm W x FULL WIDTH x 3mm (1/8")
REQUIREMENTS. MIN. 50mm
STEEL SUPPORT PLATE WELDED TO ALL
OR AS REQUIRED
ANGLE IRON.
PIPE SUPPORT DETAIL ON ROOF TYPICAL DETAIL OF GROUPED PIPING & INSTALLATION DETAIL OF IN-LINE CIRCULATION PUMP
The Contractor shall check and verify all dimensions and report
any discrepancies before proceeding.
N.T.S. M/SD #6005A N.T.S. Do not scale drawings.
CONDUIT THROUGH ROOF MEMBRANE
N.T.S.
50-10-346
:iDate :iNote
ISSUED
DETAILS 2
M-8
PLUMBING
GENERAL NOTES:
1. ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE LATEST
EDITION OF ARCHITECTURAL / CONSULTANTS DRAWINGS. VERIFY SERVICE
SIZE, LOCATION & INVERTS BEFORE COMMENCE OF INSTALLATION.
NOTES:
NUMBER DRAWING NAME The Contractor shall check and verify all dimensions and report
any discrepancies before proceeding.
P-1 SITE PLAN
Do not scale drawings.
SYMBOL DESCRIPTION
EXISTING SERVICE
SANITARY DRAIN
SANITARY VENT
STORMWATER DRAIN
FOOTING DRAIN
IRRIGATION PIPE
CIRCULATION PUMP
GATE VALVE
BALANCING VALVE
HOSE BIBB
FLOOR DRAIN
ROOF DRAIN
TB TO BELOW
FB FROM BELOW
TA TO ABOVE
FA FROM ABOVE
FB FROM BELOW
V.UP VENT UP
BUILDING LOAD
SERVICE EXISTING * NEW TOTAL
WATER 110 FU 230.50 FU 340.50 FU
- 10521 L - ISSUED
STORM
SITE PLAN
1/16" = 1'-0". SITE
PLAN
PLUMBING
P-1
#401 - 134 Abbott Street, Vancouver, BC, V6B 2K4
t: 604-683-5060 e: info@urban-arts.ca
SEAL:
NOTES:
The Contractor shall check and verify all dimensions and report
any discrepancies before proceeding.
50-10-346
:iDate :iNote
ISSUED
FOUNDATION
PLAN
PLUMBING
P-2
A B C D E F G H
D1 E1
EXISTING BRIDGE
#401 - 134 Abbott Street, Vancouver, BC, V6B 2K4
NEW ASPHALT PATH
t: 604-683-5060 e: info@urban-arts.ca
DECK
SOFT LANDSCAPING
SEAL:
W 200.4
5
0.
20
W
SKY LIGHT EXISTING - SEE
ABOVE ENVELOPE DWGS
2
HB
D 200.1
MW200.3
SHELVING
PAC
BIKE RACKS EDGE OF CONC
FOUNDATION TO ALIGN
WITH OVERHANG
NOTES:
ABOVE
STORAGE This drawing is the property of Urban Arts Architecture and may
WRECK ROOM SHELVING not be reproduced without their permission and unless the
BULKHEAD ABOVE
reproduction carries their name. All designs and all other
information shown on this drawing are for use on the specified
project only and shall not be used otherwise without written
permission of this office.
203
D 203.1
SHELVING
20" X 24" DUCT BOOK RETURN ENTRY PLAZA The Contractor shall check and verify all dimensions and report
201 UNIT PAVERS any discrepancies before proceeding.
STORAGE
Do not scale drawings.
MW201.1
PORT ROOM ROYAL ROOM
G
SHELVING
TIN
IS
W 200.3
EX
F
O ING
E
D 201.1 N D
LI UIL
MW200.3
B
BULKHEAD ABOVE
SHELVING
PAC
CANOPY ABOVE
MW200.2
STORAGE FILL IN P
LINE OF EXPOSED
WINDOW EXISTING
BEAMS ABOVE
W 200.2
STRUCTURAL
INFO DESK
MW200.1
COLUMNS
LINOLEUM 200
STORAGE LIBRARY
SKY LIGHT
ABOVE
3
SHELVING
CHECK
W 200.1
NOTICES
SF202.1
D 202.1
202 SHELVING
STUDY RM PERMANENT ENTRANCE
MAT C/W DRAIN
ELECTRICAL PANEL D 101.1 NOTICES
CHECK CHECK
OUT OUT
D 100.1
SHELVING UNIT PAVERS
CW 100.1 CONCRETE BASIN
MW200.3
4
SF 101.1
D 100.2
SHUTTER
CW 100.2
OVER VESTIBULE 1
LOBBY
FOOT GRILLE
LINE OF
SHUTTER
ABOVE
5
NOTICES
BRACE BAY
Y
TELEPHONE ROOM JANITORIAL
E BA
ROOM
BRAC
HALL
FILL IN
EXISTING OPEN TO
OPENING ABOVE PA
306 307
SERVER 308
305 STORAGE
MECH ROOM #1 EL 100.0 FLEX OFFICE
WEST CORRIDOR
F
6
NOTICES
HW 103 EXIT1 U/C
FR
DW
25 RISERS @ 7-1/8"
ATRIUM
23 TREADS @ 11"
309 ELECTRICAL PANEL
STAFF WC
BRACE BAY
WOMEN'S EXIT TO 310
LOCKERS
CHANGE LANDING
STAFF RM
ATRIUM WHITE BOARD
ROOM SERVERY
BENCH
GYM
HOOKS
311
312 FLEX OFFICE
LINE OF EXISTING MEETING RM
U/C U/C
FRIDGE FREEZER DW
401 HB
BULKHEAD
ABOVE SLIDE COMMUNITY KITCHEN
PANTRY
OUT-GATE
TV MONITOR GAT
7
E
BRACE BAY
STORAGE CLOSET
MACHINES
VENDING
(N.I.C)
MEETING
ROOM
BENCH
NEW OPENING ADD NEW
IN GYM WALL DOORS IN PAVERS
EXIST. WALL 400 REFER TO
LANDSCAPE
71
MULTI-PURPOSE 1
P4B
FD
112 111 108 P3
ELEVATOR
MEN'S FD
P4B
LOCKER FD STORAGE
ROOM 107 EL 100.0
P4B
WOMENS WC
BRACE BAY
PERMANENT
FRIDGE EDGE OF ENTRANCE
FD CONCRETE MAT C/W DRAIN
507 402
EADS 7-1/8"
506 ELECTRICAL PANEL
"
@ 11
STORAGE
22 TR ERS @
CHILD CARE SERVERY MULTI-PURPOSE 2
NOTICES
NOTICES
24 RIS
505 106
504 105
ADULT WC EXIT 2
STORAGE CLOSET
GATE GATE
FD
FD FAMILY WC FD
JANITOR
CHILD WC
CHANGE 104
NOTICE
W/D
TABLE
LINE OF
VESTIBULE 2
FOOT GRILLE
SECURITY NOTICES
SIGN IN
LINE OF BULK
SCREEN
HEAD ABOVE
500
9
ISSUED
BRACE BAY
PAVERS
503 REFER TO
LANDSCAPE
CHILD CARE ACTIVITY ROOM
25 501
24 OFFICE HB
STOR
1
23
2
22
BRAC
AGE
3
4
502 21
0
CLOS
CUBBIES 2 9 E BA
Y
E
5 BRAC EDGE OF
BAY
1
6 CONCRETE
ET
FOUNDATION
7
8
9
10
17 18
11 15 16
13 14
13B
GROUND
FLOOR PLAN
PLUMBING
13A
t: 604-683-5060 e: info@urban-arts.ca
SEAL:
NOTES:
The Contractor shall check and verify all dimensions and report
any discrepancies before proceeding.
50-10-346
EDGE OF
CONCRETE
:iDate :iNote
ISSUED
SECOND
FLOOR PLAN
PLUMBING
P-4
A B C D E F G H
D1 E1
t: 604-683-5060 e: info@urban-arts.ca
SEAL:
1
SKYLIGHT SKYLIGHT
2
NEW STANDING SEAM METAL ROOF
NOTES:
AHU.
SEE
MECH
SLOPE TO
DRAIN
NEW GLAZED
SKYLIGHT
3
OVERFLOW
SCUPPER
SCUPPER DRAIN
4
50-10-346
SKYLIGHT
5
EXISTING ROOF
SLOPED MEMBRANE
ROOF
SLOPE TO DRAIN SLOPED @ 1:12
7
LOW SLOPE
RD
MEMBRANE ROOF
SLOPED TO DRAIN 2% MIN.
HEAT PUMP
SEE MECH
8
RD
RD RD
OVER FLOW
SCUPPER OVER
FLOW
ERV. SEE MECH SCUPPER
FITNESS TERRACE
BELOW
RD
9
:iDate :iNote
RD
OVER
FLOW
SCUPPER
13B
LINE OF BUILDING
BELOW ROOF
FLOOR PLAN
PLUMBING
13A
P-5
DUPLEX CONTROL PANEL.
WITH HIGH LEVEL ALARM & REMOTE 1-1/4"VENT UP
ALARM OUTPUT. 1/2"HOT WATER RETURN EXTERIOR WALL
DOBNEY FOUNDRY....COVER C-18 1/2"COLD WATER SUPPLY
CONCEALED IN WALL. CONCEALED IN WALL.
FRAME C-18
EYS SEAL & CONDUIT (BY OTHERS) SLOAN SENSOR FAUCET
1/2"HOT WATER SUPPLY DOWNSPOUT TO ROOF
FINISHED GRADE CONCEALED IN WALL.
JUNCTION BOX (BY OTHERS) -PROVIDE BRACKET FOR EACH LENGTH
24"x36" H-20 COVER FOR WALL HUNG BASIN W/ EXPOSED FLEXIBLE WATER
3-COURSES OF COMMON BRICK
DUPLEX PUMPS. CONCEALED CARRIER . SUPPLY.C/W ESCUTCHEON. 1 1/4" x 3/16" W.I. STRAP
(200x57x95mm) OR (8"x2-1/4"x3-3/4")
-ANCHOR TO WALL WITH EXPANSION
AUTOMATIC HOLD OPEN SENSOR CABLE OUT OF WALL SHIELDS - PROTECT STRAP WITH
#401 - 134 Abbott Street, Vancouver, BC, V6B 2K4
PRECAST REINFORCED CONC. (H20) c/w ESCUTCHEON P-TRAP IN FRONT ENAMEL PAINT
LID WITH 635mm (25") DIA. OPENING CONTROL PANEL 48" UPPER GUIDE RAIL SUPPORT RUN IN WALL C/W
TO BE IN STORAGE BRACKET.
ESCUTCHEON.
t: 604-683-5060 e: info@urban-arts.ca
ROOM 507. 12" 24" 12"
POWER SUPPLY FROM
RIM.ELEV.=1.48M TRANSFORMER IN CEILING SPACE. CLEAN OUT WITH THREADED PLUG
TO BE CONFIRMED ON SITE
PRECAST REINFORCED SPUN CATCH
DETERMINED BY GRADE
GRADE SEAL:
BASIN SECTIONS TO A.S.T.M. C76-65T SLOAN VPB-BDT BOX 1-1/4"DRAIN
WITH STOPS, MIXING VALVE, CONCEALED IN WALL.
X 3" SCH 40 PVC DISCHARGE CONTROL MODULE. OFFSET TO CLEAR CARRIER.
2" ELECTRICAL PIPING, MIN.18" BURIAL DEPTH.
CLASS II - USE STANDARD LENGTHS CONDUIT
3" PVC BALL VALVE CONCEALED CARRIER
Y
2"
GALVANIZED GUIDE RAIL NOTES:
LAG PUMP ON 2" SCH 40 PVC DISCHARGE This drawing is the property of Urban Arts Architecture and may
& HIGH WATER PIPING. DETAIL OF WALL HUNG BASIN not be reproduced without their permission and unless the
ALARM.
(18") MIN.
GROUT (TYP.) reproduction carries their name. All designs and all other
30"
N.T.S.
457mm
8"
4"
200mm (8") 10mm (3/8") THICK STEEL PLATE; DEPTH OF COVER VARIES WITH
PROVIDE 2 RECESSED LIFT RINGS TYPE OF FLOOR MATERIAL USED
INTEGRAL CONCRETE BASE CHECK ARCH. DWGS. FOR
Y X
SEE DETAIL 'A' (TYP.) THICKNESS & TYPE OF FLOOR. DOWNSPOUT SHOE
BE SURE FINISHED PRODUCT IS N.T.S. P/SD #1022
LESS THAN 4' (1200mm) 30" (750mm) MIN.
SECTIONAL ELEVATION FINISHED FLOOR THE EXACT SAME LEVEL AS
FINISHED FLOOR
4' (1200mm) TO 8' (2400mm) 42" (1000mm) MIN.
2" ELECTRICAL
GREATER THAN 8' (2400mm) 60" (1500mm) MIN. CONDUIT MECHANICAL JOINT (TYP.)
4" SCH 40 PVC FROM
3" VENT PIPE REMOTE SIAMESE. DEPTH TO SUIT GROUT (TYP.)
C.I. OUTLET
GALVANIZED FLOAT BRACKET
JUNCTION BOX FOR FOOTING DRAIN
N.T.S. P/SD #2002A
GREASE INTERCEPTOR
3" SCH 40 PVC DISCHARGE PIPING C.I. INLET (SEE SPECIFICATIONS)
4" INLET PIPE
INTERCEPTOR SHALL BE 150mm (6") REINFORCED
COMPLETE WITH INTEGRAL CONC. PIT. SIZE & DEPTH TO
A
FLOW CONTROL FITTING SUIT GREASE INTERCEPTOR SIZE
A B B A
NON-CLOG SUMMERSIBLE
PUMP 50-10-346
FINISHED FLOOR
6"
WALL. GRAVITY WASTE OR SEWER PIPE
3" BOX W/
ALARM CONTROL
3" MODULE
ADJUSTABLE CLEVIS HANGER
(GRINNELL FIG. 260) TO BE HOT
BOTH PUMPS ON 36" DIA PREFABRICATED SYSTEM 15 DWV PIPE DIPPED GALVANIZED STEEL C/W 3
FIBERGLASS SUMP LAYERS OF BITUMEN COATING
PUMP #1 ON 18" CONSTRUCTION OF BOLTS, NUTS
BEDDING MATERIAL AS SPECIFIED BY AND WASHER SHALL BE SAME AS
HANGER. :iDate :iNote
PUMP 3" SCH 40 PVC GEOTECH CONSULTANT
2" 1/2" 3/4" 3/4"
ISSUED
OFF/ALTERNATE DISCHARGE PIPE 1/2" 3/4" 3/4" TRENCH BOTTOM EXCAVATED TO
NON-CLOG SEWAGE CONFORM TO SLOPE OF PIPE
PUMPS.
20"
WASHROOM COUNTER LAVATORY DETAIL DETAIL OF PIPE SUPPORT UNDER STRUCTURAL SLAB-ON-GRADE
N.T.S.
N.T.S.
G
HOT WATER TANK
TYPICAL FOOTING DRAIN CLEANOUT (SEE SPECIFICATIONS)
C.P. STOPS &
SUPPLIES IN WALL
CLAMPS The Contractor shall check and verify all dimensions and report
N.T.S. any discrepancies before proceeding.
P/SD #2009 THRUST BLOCK OUTLET
SHUT-OFF EXPOSED VALVE & (TYP.)
WATER PROOF Do not scale drawings.
VALVE UNION (TYP.) IN WALL TRAP PRIMER - WATTS
A200 EXPOSED PIPING MANBRANE
C.P. ANGLE STOP
P.R.V. VENTED T & P DISCHARGE
& RISER TO FIX. 406mm x406mm x152mm THICK
TO ATMOSPHERE
CONC. PAD (16"x16"x6")
150mm(6") HIGH CONCRETE
DRAIN PAN
HOUSEKEEPING PAD
FINISHED FLOOR 4"PVC DWV PIPE
PAN OUTLET INV.=0.15 M
FLOOR DRAIN
INTO WALL SIDE WALL FLOOR
DRAIN SEE DRAIN
FUNNEL FLOOR DRAIN ELEVATION NOTE: SCHEDULE
SEISMIC RESTRAINT IS REQUIRED,
SEE SPECIFICATIONS & REGULATIONS WALLS PROVIDE C.P.
ESCUTCHEONS
450mm
REMOTE SIAMESE CONNECTION DETAIL
BACKFILL HOT WATER TANK DETAIL TRAP PRIMER TYPE No.2 N.T.S. P/SD #4011
N.T.S. P/SD #3011
N.T.S. P/SD #3007A
PIPE SUPPORT
CAP-OFF FOR
FL. TO M.J. PVC ADAPTER FUTURE
SUBSOIL & FOOTING DRAIN DETAIL "FLEX-TEND" FLEXIBLE EXTENSION
NOTE:
N.T.S. P/SD #2020 EXPANSION, SETTLEMENT FL. TO PVC SEWER ADAPTER 1. ALL THRUST BLOCK BEARING
COMPENSATOR FITTING SURFACES SHALL BE
AGAINST UNDISTURBED SOIL.
CAPPED END
DETAIL KEYNOTES:
1. WET-PIPE SPRINKLER SUPPLY TO SECOND FLOOR
2. WET-PIPE SPRINKLER SUPPLY TO GROUND FLOOR
3. NOT IN USE
4. DRY-PIPE SPRINKLER SUPPLY TO COMBUSTIBLE CANOPIES
5. WET-PIPE VALVE STATION
6. DRY-PIPE VALVE STATION
7. REMOTE SIAMESE CONNECTION. SEE DETAIL ON P-7.
8.
9.
JANITORIAL 10.
ROOM 11.
12.
13.
14.
15.
16. WET-PIPE SPRINKLER SUPPLY TO WATER CURTAIN AS INDICATED IN CODE REPORT
17. FLOW SWITCH
MECH ROOM #1
N.C
:iDate :iNote
ISSUED
M
AIR COMPRESSOR
DETAILS
PLUMBING
P-7
DRAINS AND HOSE BIBBS SCHEDULE
CONVENTIONAL ROOF LACQUERED CAST IRON ROOF DRAIN WITH ANCHOR FLANGE, CAST IRON MEMBRANE CLAMP WITH INTEGRAL GRAVEL STOP, ADJUSTABLE CAST IRON EXTENSION FLANGE,
RD-1
(TPO MEMBRANE ROOFING) UNDERDECK CLAMP AND SELF-LOCKING POLYDOME STRAINER. MIFAB R-1220-EU, ZURN Z-100-ERC, WATTS RD-100-BED. #401 - 134 Abbott Street, Vancouver, BC, V6B 2K4
SEAL:
FD-2 MECHANICAL EQUIPMENT
MIFAB F1100-EG, ZURN ZN-211-BF, WATTS FD-100-C-EG-1
FD-3 ELEVATOR PIT, ELEC. PULL PIT SIDE OUTLET /w BACKWATER VALVE. DURA-COATED CAST IRON BODY, BRONZE VALVE ASSEMBLY AND SECURED SLOTTED GRATE. ZURN Z-629 OR EQUAL.
ENCASED NON-FREEZE WALL MOUNTED HOSE BIBB 3/4" MALE CONNECTION C/W ANTI-SIPHON AND VANDAL RESISTANT INTEGRAL VACUUM BREAKER. SATIN FINISHED
HB-1 EXTERIOR NICKEL BROZNE BOX WITH HINGED LOCKING COVER. MIFAB MHY-20 OR EQUAL.
ACID RESISTANT COATED INTERIOR AND EXTERIOR FABRICATED STEEL GREASE INTERCEPTOR (50GPM). INTERCEPTOR SHALL HAVE INTERNAL AIR RELIEF BY-PASS,
CLEAN-OUT PLUG AND VISIBLE DOUBLE WALL TRAP SEAL WITH REMOVABLE PRESSURE EQUALIZING/ FLOW DIFFUSING INLET BAFFLE. GASKET NON-SKID SECURED COVER
GI-1 COMMUNITY KITCHEN WITH RECESSED LIFT HANDLES C/W FLOW CONTROL FITTING. INTERCEPTOR SHALL EQUIPED WITH USER NOTIFICATION SYSTEM WITH SENSOR BOX, GREASE LEVEL NOTES:
SENSOR, AND DISPLAY BOX, AUDIO ALARM, AND JUNCTION BOX FOR 120V. ZURN Z-1170-UN OR EQUAL This drawing is the property of Urban Arts Architecture and may
not be reproduced without their permission and unless the
reproduction carries their name. All designs and all other
information shown on this drawing are for use on the specified
project only and shall not be used otherwise without written
permission of this office.
The Contractor shall check and verify all dimensions and report
any discrepancies before proceeding.
SINK KINDRED LBS7308 P-1/3 18 GAUGE STAINLESS STEEL, SINGLE COMPARTEMENT SINK WITH FAUCET LEDGE, 3 HOLES -
8" CENTER, MANUAL FAUCET
FAUCET AMERICAN STANDARD RELIANT F15
SK-1 COUNTER TOP SINK 5.7LPM
DRAIN
SUPPLY
SINK KINDRED LBD6410P-1/3 18 GAUGE STAINLESS STEEL, DOUBLE COMPARTEMENTS SINK WITH FAUCET LEDGE, 3
HOLES - 8" CENTER, MANUAL FAUCET
FAUCET AMERICAN STANDARD RELIANT F15
SK-2 COUNTER TOP SINK 5.7LPM
DRAIN
SUPPLY
SINK KINDRED ALBS4006P-1/3 18 GAUGE STAINLESS STEEL, SINGLE COMPARTEMENTS SINK WITH FAUCET LEDGE,3 HOLES
- 8" CENTER, MANUAL FAUCET, COUNTER MOUNTED BUBBLER.
FAUCET AMERICAN STANDARD RELIANT F15
SK-3 COUNTER TOP SINK 5.7LPM
DRAIN HAWS 5060 LF
SUPPLY
SINK KINDRED LBS4408P-1/3 18 GAUGE STAINLESS STEEL, SINGLE COMPARTEMENTS SINK WITH FAUCET LEDGE, 3 HOLES
- 8" CENTER, MANUAL FAUCET
FAUCET AMERICAN STANDARD RELIANT F15
SK-4 COUNTER TOP SINK 5.7LPM
DRAIN
SUPPLY
SINK KINDRED QCLA 2233R/8 18 GAUGE STAINLESS STEEL, DOUBLE COMPARTEMENTS SINK WITH FAUCET LEDGE, 3
HOLES - 8" CENTER, MANUAL FAUCET. C/W FITTING FOR DISHWASHER CONNECTION.
FAUCET AMERICAN STANDARD RELIANT PULL SPRAY
SK-5 COUNTER TOP SINK 5.7LPM
DRAIN
SUPPLY
SINK KINDRED LBS4408P-1/3 18 GAUGE STAINLESS STEEL, DOUBLE COMPARTEMENTS SINK WITH FAUCET LEDGE, 4
HOLES - 8" CENTER, MANUAL FAUCET. C/W WATER BOX AND BOOSTER PUMP PACKAGE.
FAUCET AMERICAN STANDARD RELIANT F15
SK-6 COUNTER TOP SINK ALARM UPON HI-WATER LEVEL. 5.7LPM
DRAIN HAMLET GARNEAU W-BOX SYSTEM
SUPPLY
SHOWER
SH-1 SHOWER CABINET
TRIM SYMMONS 1-117-FS
DRAIN FLOOR DRAIN
MOP SINK FIAT MSB 2424 MOLDED STONE MOP SINK, FLOOR MOUNTED WITH 10" WALL HIGHT, 1"WIDE SHOULDER.
WALL MOUNTED FAUCET CHROME PLATED WITH VACUUM BREAKER, INTEGRAL STOPS,
JS-1 FAUCET FLOOR MOUNTED DELTA 28T2383 5.7LPM
DOME STRAINER AND STAINLESS STEEL LINT BASKET.
STRAINER FIAT 1453BB
MOP SINK FIAT MSB 3624
JS-2
FAUCET FLOOR MOUNTED DELTA 28T2383
URINAL AMERICAN STANDARD WASHBROOK VITREOUS CHINA, ULTRA HIGH EFFICIENCY, TOP SPUD CONNECTION. C/W SLOAN ELETRONIC
FLUSHOMETER, TRANSFORMER EL-154.
U-1 FLUSH VALVE WALL MOUNTED SLOAN 186 ES-S 0.9
CARRIER
DRINKING FOUNTAIN HAWS ADA8AC BARRIER FREE WALL MOUNTED WATER COOLER. C/W BOTTLE FILLER.
WALL MOUNTED
DF-1 FITTING
WATER COOLER
CARRIER
PP-1 SANITARY SANITARY SUMP SUBMERSIBLE DUPLEX ZOELLER JX6292 50 30 0.5 3450 208/3/60 C.I. BRZ 127 1,2,6,7
ALARM UPON HI-WATER LEVEL
PP-2 SANITARY SANITARY SUMP SUBMERSIBLE DUPLEX ZOELLER JX6292 50 30 0.5 3450 208/3/60 C.I. BRZ 127 1,2,6,7
PP-3 DHW RECIRC. ROOF MECH. ROOM IN-LINE ARMSTRONG ASTRO 50B - TA 10 12 0.1 2800 115/1/60 BRONZE PPC 140 1,3,4,8
PP-4 SANITARY PACKAGE UNIT LIBRARY SUBMERSIBLE SIMPLEX ZOELLER M53 20 15 0.5 - 115/1/60 - - - 8 ALARM UPON HI-WATER LEVEL
PP-5 SANITARY ELEV. SUMP SUBMERSIBLE SIMPLEX ZOELLER NX282 50 15 0.5 3450 115/1/60 C.I. D.I. 126 1,2,6,7 ALARM UPON HI-WATER LEVEL
DF-1 WATER COOLER 2ND FLOOR WALL MOUNTED HAWS ADA8AC 0.75 115/1/60
EQUIPEMENT
SCHEDULES
PLUMBING
P-8
A B C D E F G H
D1 E1
EXISTING BRIDGE
#401 - 134 Abbott Street, Vancouver, BC, V6B 2K4
NEW ASPHALT PATH
t: 604-683-5060 e: info@urban-arts.ca
DECK
SOFT LANDSCAPING
SEAL:
W 200.4
5
0.
20
W
SKY LIGHT EXISTING - SEE
ABOVE ENVELOPE DWGS
2
HB
D 200.1
MW200.3
SHELVING
PAC
BIKE RACKS EDGE OF CONC
FOUNDATION TO ALIGN
WITH OVERHANG
NOTES:
ABOVE
STORAGE This drawing is the property of Urban Arts Architecture and may
WRECK ROOM SHELVING not be reproduced without their permission and unless the
BULKHEAD ABOVE
reproduction carries their name. All designs and all other
information shown on this drawing are for use on the specified
project only and shall not be used otherwise without written
permission of this office.
203
D 203.1
SHELVING
20" X 24" DUCT BOOK RETURN ENTRY PLAZA The Contractor shall check and verify all dimensions and report
201 UNIT PAVERS any discrepancies before proceeding.
STORAGE
Do not scale drawings.
MW201.1
PORT ROOM ROYAL ROOM
G
SHELVING
T IN
IS
W 200.3
E X
F
O G
E DIN
D 201.1 N
LI UIL
MW200.3
B
BULKHEAD ABOVE
SHELVING
PAC
CANOPY ABOVE
MW200.2
STORAGE FILL IN P
LINE OF EXPOSED
WINDOW EXISTING
BEAMS ABOVE
W 200.2
STRUCTURAL
INFO DESK
MW200.1
COLUMNS
LINOLEUM 200
STORAGE LIBRARY
SKY LIGHT
ABOVE
3
SHELVING
CHECK
W 200.1
NOTICES
SF202.1
D 202.1
202 SHELVING
STUDY RM PERMANENT ENTRANCE
MAT C/W DRAIN
ELECTRICAL PANEL D 101.1 NOTICES
CHECK CHECK
OUT OUT
D 100.1
SHELVING UNIT PAVERS
CW 100.1 CONCRETE BASIN
MW200.3
4
SF 101.1
D 100.2
SHUTTER
CW 100.2
OVER VESTIBULE 1
LOBBY
FOOT GRILLE
LINE OF
SHUTTER
ABOVE
5
NOTICES
BRACE BAY
Y
TELEPHONE ROOM JANITORIAL
E BA
ROOM
BRAC
HALL
FILL IN
EXISTING OPEN TO
OPENING ABOVE PA
306 307
SERVER 308
305 STORAGE
MECH ROOM #1 EL 100.0 FLEX OFFICE
WEST CORRIDOR
F
6
NOTICES
HW 103 EXIT1 U/C
DW FR
GENERAL NOTES:
25 RISERS @ 7-1/8"
ATRIUM
23 TREADS @ 11"
309 ELECTRICAL PANEL
STAFF WC
BRACE BAY
WOMEN'S EXIT TO 310
LOCKERS
CHANGE LANDING
STAFF RM
ATRIUM WHITE BOARD
ROOM SERVERY
BENCH
GYM
HOOKS
311
312 FLEX OFFICE
LINE OF EXISTING MEETING RM
U/C U/C
FRIDGE FREEZER DW
401 HB
BULKHEAD
ABOVE SLIDE COMMUNITY KITCHEN
PANTRY
OUT-GATE
TV MONITOR GAT
7
E
BRACE BAY
STORAGE CLOSET
MACHINES
VENDING
(N.I.C)
MEETING
ROOM
BENCH
NEW OPENING ADD NEW
IN GYM WALL DOORS IN PAVERS
EXIST. WALL 400 REFER TO
LANDSCAPE
KEYNOTES:
71
MULTI-PURPOSE 1
P4B
FD
112 111 108 P3
ELEVATOR
MEN'S FD
P4B
LOCKER FD STORAGE
ROOM 107 EL 100.0
P4B
WOMENS WC
BRACE BAY
PERMANENT
FRIDGE EDGE OF ENTRANCE
FD CONCRETE MAT C/W DRAIN
507 402
EADS 7-1/8"
506 ELECTRICAL PANEL
"
@ 11
STORAGE
22 TR ERS @
CHILD CARE SERVERY MULTI-PURPOSE 2
NOTICES
NOTICES
24 RIS
505 106
504 105
ADULT WC EXIT 2
STORAGE CLOSET
GATE GATE
FD
FD FAMILY WC FD
JANITOR
CHILD WC
CHANGE W/D 104 NOTICE
TABLE
LINE OF
VESTIBULE 2
FOOT GRILLE
SECURITY NOTICES
SIGN IN
LINE OF BULK
SCREEN
HEAD ABOVE
500
9
ISSUED
BRACE BAY
PAVERS
503 REFER TO
LANDSCAPE
CHILD CARE ACTIVITY ROOM
25 501
24 OFFICE HB
STOR
1
23
2
22
BRAC
AGE
3
4
502 21
0
CLOS
CUBBIES 2 9 E BA
Y
E
5 BRAC EDGE OF
BAY
1
6 CONCRETE
ET
FOUNDATION
7
8
9
10
17 18
11 15 16
13 14
13B
GROUND FLOOR
SPRINKLER MAIN
13A
t: 604-683-5060 e: info@urban-arts.ca
SEAL:
NOTES:
The Contractor shall check and verify all dimensions and report
any discrepancies before proceeding.
50-10-346
EDGE OF
CONCRETE
GENERAL NOTES:
:iDate :iNote
ISSUED
KEYNOTES:
SECOND FLOOR
SPRINKLER MAIN
FP-2