Protocolo Body Infantil

You might also like

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 5

PROTOCOLOS TAC MULTICORTE 64

BODY INFANTIL
HOSPITAL 12 DE OCTUBRE.

PROTOCOLOS DE CUERPO INFANTIL

PROTOCOLOS EN FASE DE PRUEBA

TORAX<10Kg/INFANTIL (LACTANTES HASTA 1 AÑO)

SURVIEW : 80Kv
20 mAs
Longitud : 200mm

EXPLORACION :

collimacion = 64x0.625
resolucion: standar
recon-thickness = 2mm
recon-increment = 1mm
voltage = 120 / valorar la posibilidad de 80 Kv.
mAs = 50
pitch = 0.985
filtro = B
image-matrix = 512
rotation-time = 0.75
scan-mode = helix
dose right: yes
z-dom = yes
Window: mediastino 50/500
Pulmon -600/1500

DLP: 65.9 mGy/cm

RAMÓN PRIETO
PEPA MASCARAQUE
TER HOSPITAL 12 DE OCTUBRE
PROTOCOLOS TAC MULTICORTE 64
BODY INFANTIL
HOSPITAL 12 DE OCTUBRE.

TORAX 10-30Kg/ INFANTIL" ( +/- de 2 años a 5años)

SURVIEW : 80Kv
20 mAs
Longitud : 250mm

EXPLORACION :

collimacion = 64x0.625
resolucion: standar
recon-thickness = 2mm
recon-increment = 1mm
voltage = 120 VALORAR POSIBILIDAD DE 80 Kv
mAs = 60
pitch = 0.985
filtro = B
image-matrix = 512
rotation-time = 0.75
scan-mode = helicoidad
dose right: yes
z-dom = yes
Window: mediastino 50/500
Pulmon -600/1500

TORAX 30-50Kg /INFANTIL"

SURVIEW : 80Kv
20 mAs
Longitud : 300mm

EXPLORACION :

collimacion = 64x0.625
resolucion: standar
recon-thickness = 2mm
recon-increment = 1mm
voltage = 120
mAs = 80
pitch = 0.985
filtro = B
image-matrix = 512
rotation-time = 0.75
scan-mode = helix
dose right: yes
z-dom = yes
Window: mediastino 50/500

RAMÓN PRIETO
PEPA MASCARAQUE
TER HOSPITAL 12 DE OCTUBRE
PROTOCOLOS TAC MULTICORTE 64
BODY INFANTIL
HOSPITAL 12 DE OCTUBRE.

Pulmon -600/1500

ABDOMEN <10Kg/INFANTIL"

SURVIEW : 80Kv
20 mAs
Longitud :200mm

EXPLORACION :

collimacion = 64x0.625
resolucion: standar
recon-thickness = 2mm
recon-increment = 1mm
voltage = 120 -+

mAs = 70
pitch = 0.985
filtro = A
image-matrix = 512
rotation-time = 0.75
scan-mode = helix
dose right: yes
z-dom = yes
Window: Abdomen 35/350

ABDOMEN 10-30Kg/INFANTIL"

SURVIEW : 80Kv
20 mAs
Longitud :250mm

EXPLORACION :

collimacion = 64x0.625
resolucion: standar
recon-thickness = 2mm
recon-increment = 1mm

RAMÓN PRIETO
PEPA MASCARAQUE
TER HOSPITAL 12 DE OCTUBRE
PROTOCOLOS TAC MULTICORTE 64
BODY INFANTIL
HOSPITAL 12 DE OCTUBRE.

voltage = 120
mAs = 80
pitch = 0.985
filtro = A
image-matrix = 512
rotation-time = 0.75
scan-mode = helix
dose right: yes
z-dom = yes
Window: Abdomen 35/350

TX 30-50Kg/INFANTIL"

SURVIEW : 80Kv
20 mAs
Longitud :300mm

EXPLORACION :

collimacion = 64x0.625
resolucion: standar
recon-thickness = 2mm
recon-increment = 1mm
voltage = 120
mAs = 90
pitch = 0.985
filtro = A
image-matrix = 512
rotation-time = 0.75
scan-mode = helix
dose right: yes
z-dom = yes
Window: Abdomen 35/350

RAMÓN PRIETO
PEPA MASCARAQUE
TER HOSPITAL 12 DE OCTUBRE
PROTOCOLOS TAC MULTICORTE 64
BODY INFANTIL
HOSPITAL 12 DE OCTUBRE.

ANGIO NINO CON TEST/INFANTIL" (BOLUS TEST FOR ANGIO)

collimation = 16x0.625
direction-ui = Out
dom = no
mAs = 30
mAs-per-slice = 300
voltage = 120
z-dom = no

recon-thickness = 5
filter = B

EXPLORACION ANTEVERSION FEMORAL


LA EXPLORACION CONSISTE EN HACER 3 SERIES , CON CORTES EN
LA PELVIS, EN RODILLAS Y EN TOBILLOS
SON SERIES SECIUENCIALES
SURVIEW

RAMÓN PRIETO
PEPA MASCARAQUE
TER HOSPITAL 12 DE OCTUBRE

You might also like