Hse Daily Report: HF0287-M0287H1
Hse Daily Report: HF0287-M0287H1
Hse Daily Report: HF0287-M0287H1
Rig : 5005 Date: 2019 12 19 Days LTI Free: 526 Rig Manager
HF0287-
Well M0287H1
Date operation start: 2019/10/08 Petrochina DSV
Total POB 69 0%
PCH 3 0%
ANTON 34 1 3%
Third Party 35 0%
UA
UC 1
SC
SA
Daily Inspections 1
Audits 0
Drill 0
Finding 1
Near miss 0
Incident 0
Activity 1
4
Huang Wei
Umer Farooq
TOTAL: 1
Action
DRILLING CONTRACTOR UAUC OBSERVATION 2019
1 12/1/2019 HF-0287 Rig site AT5005 UC UC Fire hoses are not properly covered and placed inside the box
2 12/1/2019 HF-0287 Rig site AT5005 UA UA Floormen were working at rig floor without safety glasses
Grounding with the mud tank#7 is not installed yet, meanwhile, power junction box
3 12/2/2019 HF-0287 Rig site AT5005 UC UC
observed without grounding
4 12/2/2019 HF-0287 Rig site AT5005 UC UC Forklift operator cabin observed full of rubbish and cigarates butts
Fire Extenguisher on the rig floor duty room found empty, meanwhile, another F.E
5 12/2/2019 HF-0287 Rig site AT5005 UC UC
found empty inside the forklift operator cabin
6 12/3/2019 HF-0287H1 Rig site AT5005 UC UC One chemical sack found damage and chemical is leaking
Welder was doing welding job without arrangement of DCP fire extinguisher near to
7 12/3/2019 HF-0287H1 Rig site AT5005 UA UA
him
8 12/4/2019 HF-0287H1 Rig site AT5005 UC UC Manual slips handles observed without green color
9 12/4/2019 HF-0287H1 Rig site AT5005 UA UA Welder was doing welding job without welding PPE
10 12/5/2019 HF-0287H1 Rig site AT5005 UC UC Some safety signs on rig floor damaged or not posted at all
Crane operator was performing the lifting operation without barricade the crane
11 12/5/2019 HF-0287H1 Rig site AT5005 UA UA
radius area
12 12/6/2019 HF-0287H1 Rig site AT5005 UA UA Mud boy was mixing the chemical without wearing the google
Walk way on the flow line is not properly covered, chance of fell down from height is
13 12/6/2019 HF-0287H1 Rig site AT5005 UC UC
quite possible
14 12/6/2019 HF-0287H1 Rig site AT5005 UC UC Body wash station on mud tank is not connected yet with clean water line
15 12/7/2019 HF-0287H1 Rig site AT5005 UA UA Welder is doing grinding job near to workshop without PPE
16 12/7/2019 HF-0287H1 Rig site AT5005 UC UC Aftet cleaning the tank, mud tank lid was not closed, chance of fell down inside
17 12/8/2019 HF-0287H1 Rig site AT5005 UA UA some garbage observed inside the rig floor duty room
18 12/8/2019 HF-0287H1 Rig site AT5005 UC UC One SCBA have an air leakage problem
19 12/9/2019 HF-0287H1 Rig site AT5005 UA UA Mechanic was working without hard hat and also was smoking near gas cylinders
20 12/9/2019 HF-0287H1 Rig site AT5005 UC UC Forklift reverse alarm is not functioning and operator cabin is full of rubbish
21 12/10/2019 HF-0287H1 Rig site AT5005 UC UC Bad housekeeping observed inside the workshop and surrounding area
22 12/10/2019 HF-0287H1 Rig site AT5005 UA UA Many cigarette butts and rubbish observed inside the mud engineer lab
23 12/11/2019 HF-0287H1 Rig site AT5005 UC UC Casing lay down on ground without placing on casing rack
24 12/11/2019 HF-0287H1 Rig site AT5005 UA UA Mud boy and mud engineer were mixing chemical without proper PPE
25 12/12/2019 HF-0287H1 Rig site AT5005 UC UC One SCBA found with low air pressure
26 12/12/2019 HF-0287H1 Rig site AT5005 UA UA Link was lifted up by crane without tag line and bankman
27 12/13/2019 HF-0287H1 Rig site AT5005 UC UC Camp fire pump is not switing on due to have low battery problem
28 12/13/2019 HF-0287H1 Rig site AT5005 UC UC Mud spillage observed around the trip tank
29 12/14/2019 HF-0287H1 Rig site AT5005 UA UA AD started the mud tank cleaning job without PTW
30 12/14/2019 HF-0287H1 Rig site AT5005 UC UC Eye wash station on mud tank found empty
31 12/15/2019 HF-0287H1 Rig site AT5005 UA UA Crew were working on the mud pump with out proper PPE
32 12/16/2019 HF-0287H1 Rig site AT5005 UA UA Electrician was working on electrical installation without electrical PPE
33 12/17/2019 HF-0287H1 Rig site AT5005 UC UC Chemcial spillage on the walkway of mud tank cause slippery hazard
34 12/18/2019 HF-0287H1 Rig site AT5005 UC UC One Mud tank's lid found open wide, it may cause of fell down inside the tank
35 12/19/2019 HF-0287H1 Rig site AT5005 UC UC Fire extenguisher is not available in public toilet
36
37
38
39
40
41
42
43
45
46
47
48
49
50
51
52
53
54
55
56
57
58
OBSERVATION 2019
Closed Status Recorded
Action taken Immediately Observed By
Date O/C by
Keep protect the fire hoses inside the box to prevent from
HSE 12/2/2019 O HSE
damage by harsh weather
Advise them about to wear all PPE while at work place HSE 12/1/2019 C HSE
New safety signs have been arranged and will posted within
HSE 12/6/2019 C HSE
due date
Give him new google and request him to wear all time while
HSE 12/6/2019 C HSE
mixing the chemical
Advise him about to wear all grinding related PPE HSE 12/7/2019 C HSE
Advise mud boy about to close the lid of mud tank after
HSE 12/7/2019 C HSE
finish cleaning tank
Advise all crew on rig floor about to keep clean the entire rig
HSE 12/8/2019 C HSE
floor
Informed RM about to fix the air leakage problem with SCBA HSE 12/8/2019 C HSE
Advise them about to wear all PPE while mixing the chemical HSE 12/11/2019 C HSE
Fill the SCBA and put back at respective place HSE 12/12/2019 C HSE
Informed rig manager about to fix the problem with the camp
HSE 12/13/2019 C HSE
fire pump
Advise AD about to fill the eye wash station with fresh and
HSE 12/14/2019 C HSE
clean water
Advise all crew about to wear all PPE before before to start
HSE 12/15/2019 C HSE
the work
advise all crew about to keep close the all tank lids after the
HSE 12/18/2019 C HSE
end of work
NO. Name company Position Nationality D\N Shift Room N Date In Date out
Petrochina
1 79 948 1 1 0 2 0 0 0 0
2 78 936 0 3 0 1 1 0 0 0
3 74 888 1 1 0 0 1 0 0 0
4 75 900 1 1 0 1 1 0 0 0
5 73 876 1 1 0 2 2 0 0 0
6 70 840 1 2 0 0 0 0 0 0
7 69 828 1 1 0 1 0 0 0 0
8 69 828 1 1 0 0 0 0 0 0
9 68 816 1 1 0 0 0 0 0 0
10 69 828 1 1 0 0 0 0 0 0
11 66 792 1 1 0 0 1 0 0 0
12 75 900 1 1 0 1 0 0 0 0
13 78 936 0 2 0 1 0 0 0 0
14 72 864 1 1 0 3 1 0 0 0
15 67 804 1 0 3 0 0 0 0
16 67 804 1 0 0 1 0 0 0 0
17 67 804 0 1 0 0 0 0 0 0
18 68 816 0 1 0 0 0 0 0 0
19 69 828 0 1 0 1 0 0 0 0
20 0 0 0 0 0 0 0 0 0 0
21 0 0 0 0 0 0 0 0 0 0
22 0 0 0 0 0 0 0 0 0 0
23 0 0 0 0 0 0 0 0 0 0
24 0 0 0 0 0 0 0 0 0 0
25 0 0 0 0 0 0 0 0 0 0
26 0 0 0 0 0 0 0 0 0 0
27 0 0 0 0 0 0 0 0 0 0
28 0 0 0 0 0 0 0 0 0 0
29 0 0 0 0 0 0 0 0 0 0
30 0 0 0 0 0 0 0 0 0 0
31 0 0 0 0 0 0 0 0 0 0
Total 1353 16236 14 21 0 17 7 0 0 0
12/19/2019
Inspection Drills
1 0
1 0
1 0
1 0
1 1
1 1
1 0
1 0
1 0
1 0
1 0
1 1
1 0
1 1
1 1
1 0
1 0
1 0
1 1
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
19 6