HEAT EXCHANGER SHELL ID CAL

Shell ID according to Table 1

Number of Tubes 115


Tube OD mm 19.05 0.01905 meter

For Triangular Pitch


Bundle Diameter(ID) 0.298 meter
Shell ID 0.348 meter
For Squar Pitch
Bundle Diameter(ID) 0.328 meter
Shell ID 0.378 meter
By Simple geometry
Triangular Pitch 0.031 Meter

Area of the Pitch 0.001 Meter2


Total Area 0.097 Meter2

Bundle ID 0.352 Meter


Shell Id 0.402 Meter

Prem Baboo
R SHELL ID CALCULATIONS
Table1

Triangular pitch

Number of Passes 1 2 4 6 8

K1 0.319 0.249 0.175 0.0743 0.0365

n 2.14 2.207 2.285 2.499 2.675

1/n 0.4672897 0.4531038 0.4376368 0.4001601 0.3738318

Squar pitch

Number of Passes 1 2 4 6 8

K1 0.215 0.156 0.158 0.0402 0.0331

n 2.207 2.291 2.263 2.617 2.643

1/n 0.4531038 0.4364906 0.4418913 0.3821169 0.3783579


Sizing Heat Exchanger

Design og Pre-Heater
C-302

Side Shell

Fluid Condensing Vapor

Inlet Temperature ℃ 75

Outlet Temperature ℃ 42

Density Kg/m3 1000

ML Feed Rate m3/hr 0.845

Mass Feed Rate Kg/hr 844.8


14.0808080808081
Sp heat Kcal/Kg C 0.9

Heat Load Kcal/hr 25092

Design Heat Load Kcal/hr

LMTD ℃

LMTD Correction ℃

Overall U Kcal/hr.m2.C

Calculated HTA m2

Provide HTA 20% extra m2

Tube OD mm

Tube Length mm

Area of One Tube m2

Calculated Total No of Tubes m2


Tube OD

Tube ID

Area of One Tube

Tube bundle csa

No of Tubes
Tube

EA+Cyclo ML

35

52

820

4.00

3280 0.9111111111 0.2346801347

0.45 3.762 1.881

25092 Results

27601.2 10% excess

13.450

12.105

200 50- 250 BTU/hr.ft2.F


243
11.401 486

13.68

19.05

2000

0.119634

114.36
340

328

0.119634

0.08445344

0.705931758530184
3.2857142857
1.1895840669
13.450079272