• 5A receptacle points can be a three pin or two pin points, but a 15A receptacle
point is always a three pin point.
• While designing a single storied building, we are always seeing the conduits going
down. So ‘conduit going down’ mark should be placed after each conduit
termination.
• In fittings and fixture diagram fluorescent lights must be small in length compared
to the diameter of ceiling fan.
Wrong Right
• Any size of conduits can be used but only those available to the market have to be
used.
• 5A components are driven by 1.5 mm2 wires and 15A components from 4 mm2. 2.5
mm2 wires are also used to drive some instruments but it is usual practice to use 4
mm2 wires for high current rated instruments. 2.5 mm2 wires are generally used to
connect switchboards if a lot of load is connected to the switchboard and also for
switchboard to distribution board connection.
Wire cross
sections are
expressed as this
• If more than one conduit is to be placed in a room then 90o alignment between the
conduits should be kept as long as possible.
• Prime target of conduit layout is to use least length of conduit not least number of
them.
• Wires are cheaper than conduits, so there should be no law about how much wire
is need in a conduit layout.
Example 1:
Fittings and Fixtures layout:
A4 SL1 5A
A3
5
4
A1
C2 3
F2
SS2 F3
A2
2 SS3
ST1
F1 1
SS1
K1
K1
TV1
TS1
C1
Conduit Layout:
C1 C1
L L
C1 C2
C2 3 C1
L F L
F
C1
S
C4 C3
C1
2
S
T C2
C6 C7 S
C3
F
C2
1
S C1
L
SB 1 SB 2 SB 3
R R R
K K C F SS ST TS A C F SS A F SS
1 2 1 1 1 1 1 1 2 2 2 2 3 3
SB 5 SB 4
A K SL
4 3 1
Example 2:
Fittings and Fixtures layout:
L1
A4 SL1 5A
A3
5
4
A1
C2 3
L2
F2 SS2
F3
A2
2 SS3
ST1
F1 1
SS1
K1 K1 L3
TV1
TS1
C1
L4
Conduit Layout:
L C1 L
C1
L
C1 C2
5
C1
4 6
C2 C2 C1
3
L F L
F
C1
S
C4 C4
C1
2 S C2
L
7
T
C2
C2
C6 C7 S
C3
F
C1
1 C1
S C1
L
SB 1 SB 2 SB 3
R R R
K K C F SS ST TS A C F SS A F SS
1 2 1 1 1 1 1 1 2 2 2 2 3 3
SB 7 SB 6 SB 5 SB 4
L A K SL
L L L 1 4 3 1
1 2 3
Example 3:
Fittings and Fixtures layout:
A4 SL1 5A
A3
5
L1
6
S1
15A
4
A1
C2 3
L2
F2
SS2 F3
A2
2 SS3
ST1 F1
SS1 1
L3
K1
K1
TV1
TS1
C1
L4
L C1 L
C1
C8,9
L
C1 C2
5
C8 C9 C1
4
S
C2 3 C2 6 C1
L F L
F
C1
S
C4 C4
C1
2 S C2
L
7
T
C2
C2
C6 C7 S
C3
F
C1
1 C1
S C1
L
SB 1 SB 2 SB 3
R R R
K K C F SS ST TS A C F SS A F SS
1 2 1 1 1 1 1 1 2 2 2 2 3 3
DB DB
2X1.5 mm2 ECC 2 2X1.5 mm2 ECC 2
16SWG 2X2.5 mm ECC 16SWG 2X2.5 mm ECC
16SWG 16SWG
SB 7 SB 6 SB 5 SB 4
L A K SL
L L L 1 4 3 1
1 2 3
To Supply
2X70mm2 PVC/PVC
Underground Cabls
Through 2” GI Pipes
MDB 100A SP
MCB
10 10 15
2 2 2X4 mm2
2X2.5 mm 2X2.5 mm ECC 14 SWG
ECC 16 SWG ECC 16 SWG
SB4 SB6 S1
Legends of Wires:
C1 = 2X1.5mm2
C2 = 4X1.5mm2
C3 = 6X1.5mm2
C4 = 8X1.5mm2
C5 = 10X1.5mm2
C6 = 12X1.5mm2
C7 = 14X1.5mm2
C8 = 2X2.5mm2
C9 = 2X4mm2
C8,9=2X2.5mm2 and 2X4mm2
L
• Three pin receptacle points to drive exhaust fans are denoted as, .
Like other lintel level components.
• Three pin 15A receptacle points are driven by distribution board directly, not from
any switchboard as other plug points. 2X4 mm2 wire is need for one such a point.
• Switchboards are connected to distribution board via 1.5 or 2.5 mm2 wires and 4
mm2 in case of very high loads (unusual for domestic purposes).
Practice Section:
L L
L F L
F
2
S
1
S
L
L L
4 6
3
L F L
F
2 S
7
T
1
S
L
Assignment:
Assignment 2 Figure:
A4
SL1 5A
A3
5
L1
6
C2 A1 3 ST2
L2
F2
SS2 F3 S1
A2
15A
2 SS3
A2
7
F1 1
ST1 SS1
K1 L3
K1
TV1
TS1
C1
L4
A4
SL1 5A SL2 5A
A3 SS4
5 K4
K3
L1
6 8
C2 A1 3 ST2 9
C4
L2
F2
SS2 F3 S1 SS5 A5
SS3 A2
15A
2
A2 F4
S2
7 A2
15A
C3
F1 1
ST1 SS1
K1 L3
K1
10
TV1
TS1
C1
L5
L6
L4