Professional Documents
Culture Documents
General Information: Location A Location B
General Information: Location A Location B
General Information: Location A Location B
General Information
File name: ab_1550_100ns_10s_Fiber15.trc
Test date: 7/29/2019 Customer:
Test time: 1:49:48 PM Company:
Cable ID: Fiber ID: Fiber15
Job ID:
Comments:
Locations
Location A Location B
Location
Operator
Model MAX-730C-SM2-EA
Serial number 1135517
Calibration date 6/14/2018 (UTC)
Results
Span length: 3.8901 km Average loss: 0.352 dB/km Injection level: 24.1 dB
Span loss: 1.370 dB Average splice loss: 0.101 dB
Span ORL: 36.35 dB Maximum splice loss: 0.217 dB
Graph
Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 2.475 dB/km A-B average loss: 5.873 dB/km
a 2.0003 23.575 A-B LSA loss: 4.950 dB 4-point Event Loss: 21.547 dB
A 3.9999 15.780 A-B ORL: 41.39 dB Maximum reflectance: -54.7 dB
B 6.0001 4.032
b 7.9998 0.000
Macrobend
Position (km) Delta Loss (dB)
Pass/Fail Thresholds
1550 nm (9 µm)
Splice loss (dB) 0.300
Connector loss (dB) 0.750
Reflectance (dB) -40.0
Fiber section attenuation (dB/km) 0.400
Span loss (dB) 20.000
Span length (km) 0.0000
Span ORL (dB) 15.00
Test Parameters
A→B
Wavelength (nm) 1550 nm (9 µm)
Range (km) 10.0000
Pulse (ns) 100
Duration (s) 10