The document summarizes key components of a building cooling system, including their locations and functions. It describes that a chiller uses an evaporator and compressor to cool water, which is then piped to air handling units. The air handling units condition air by cooling it and supplying it to rooms. Excessively warm water from the chiller is cooled in a cooling tower through evaporation before returning to the cooling system.
The document summarizes key components of a building cooling system, including their locations and functions. It describes that a chiller uses an evaporator and compressor to cool water, which is then piped to air handling units. The air handling units condition air by cooling it and supplying it to rooms. Excessively warm water from the chiller is cooled in a cooling tower through evaporation before returning to the cooling system.
The document summarizes key components of a building cooling system, including their locations and functions. It describes that a chiller uses an evaporator and compressor to cool water, which is then piped to air handling units. The air handling units condition air by cooling it and supplying it to rooms. Excessively warm water from the chiller is cooled in a cooling tower through evaporation before returning to the cooling system.
CHILLER ROOM CHILLER Consist of evaporator which heated water and change it to vapor. Then the vapor is transported to the compressor, where it is then compressed into a high pressure vapor. The vapor then entered the condenser where ambient water removes heat to cool it to a high pressure liquid. PIPE LINE Two separate pipes which Flow pipe that carries cold water to AHU and Return pipe that carries used or high temperature water from AHU PUMP To pump out cold water from chiller to higher level AHU Room AIR HANDLING AHU takes outside air, re-condition it UNIT ROOM AHU and supply it as fresh and cool air to the room. All hot air is taken and filtered. Next, the air is pass through cooling coil that consist of cooled fluid. The air is cool down and ready to carried out via air duct into the room. TOP ROOF Cools down excessive warm water from COOLING TOWER the chiller by flow out the water to the top of the cooling tower. Then the water will flow through the fill and flows down to a larger surface area to increase evaporation and remove heat. Large fan draw air across the fill which accelerates evaporation and further cools the water. The water then return to the cooling system to cool the heat source COOLING SYSTEM FLOW