Laboratory Test Frequency, LGED S| item of Works Type / Name of test | ae 1) Plasticity Index (PI) | One 2,000 m! it) 4 day soaked CBR One 2,000 mi? 4. Embankment iti) MDD. (Standard) _ "One 2,000 m> *| iv) FDD. ‘One 600 m5 =| | __| wer One200m | | i) Plasticity index (P1) One 5,000 m# | ii) 4 day soaked CBR (One 5,000 m# 2 ‘Sub grade iii) MDD z ine 5,000 iv) FDD One 900 me | ¥) DCP ~ One 300 m? | )FM/Gradation ‘One 500 m? ii) 4 day soaked CBR ~One,000m | 3 | Improved Sub grade| ii) MOD E- Sele tT || iv) FDD One 300m | [ vy) DCP 4 sc. One 100 m' ] i)Gradation = ‘One 500 m? | | ii) 4day soaked CBR 6 X, One 750m | ii) LAA 1 .) One 1,000m | 4 | sub-base iv) MDD One 750 mi | web | One 150 m? | vi) W/A (Stone/Brick) ones00m' | wii) DCP One 50 m* if i) Gradation One 500 m? | ij4daysoaked CBR One 750m? iii) MDD. a One 750 m? 5 | Base Course ivyeDD | One1s0m | V)LAA One 1,000 m? vi) W/A (Stone/Brick) One 500 m* wil) DCP [ One 50m? S| ttemorworks Type / Name of test Saal Teal i} Compressive Strength Set 1,000 m & | Edging ii) Water Absorption Set 1,000m 1) Compressive Strength set 2,000 m? hap se 1 Water Absorption “_set2,000 me i) Softening Point One 10,000 m2 i) Flash Point : One 10,000 m* ii Penetration (One 7.500 m= ie iv) Gradation of FA One 5,000 m= 8 | Materials ¥) Gradation of CA One 5,000 mi vi) WA of CA One 5,000 m# vi) LAA One 5,000 mé vii) Flakiness Index One 5,000 m# DFM One 50 mé ii) W/A (Coarse Aggregate) One $0 m? it AA /acy One 50 m® 9 | concrete iv) Gradation of CA ¥) Setting Time of Cement vii) CS of Concrete | i) Compressive Strength of et 300 me? if) Water Absorption of Bricks Set 300m’ it Bfflorescence of Bricks Set 300 m? 10 | Brick Works iv) Setting Time of Cement Set 300 a ¥) CS of Cement Set 300 mi Wi) FM of Sand Set 300 m* =i aac | NR sat/0 10000 If the number of test(s) to be pefformed as per specified test-frequency for any item becomes ‘whole number with a fraction equal to 0.20 or less, that case the actual number of test (s) shall the whole number only. On, the other hand if the fraction is more than 0.20 then the actual number‘ test(s) for that item shall be rounded to next whole number Engineer in-charge has the right increase the no. of tests for any item beyond the set frequency as he deems required to ensure the {quality and contractor is to perform the additional tests on his own, Implementation of various items of work should be carried out according to the set frequency. costs of all tests even additional to the frequency requirement should be covered by the quoted rate. ‘TEST FEES FOR QUALITY CONTROL TEST, LGED a name of est vit | Rate A CEMENT 2 [Seng Tine tach | 700.00 3 T compressive Strength (3,7,28 days) (Each Set comprises with 3 cubes) Set 1,200.00 4 T Fineness by sieve Each 500.00 AGGREGATE Sieve aa of ie Area bach 4 unit ‘weight 400.00 S| Absorption of Coarse Aggregate z Each 300.00 7 | Los Angles Abrasion 2 Each 1,000.00 @ [Te Percent Fes vatFV) Fach | 1860000 9 | Aureaate Casing Value Fach | 90000 70 | Agrees impoct Value tech | 60000 11 | CBR of Coarse Aggregate - Each 8,000.00 12 | CBR of Fine Aggregate Fach | 7.00000 15 cP Test tach | 20000 16 | Field Density by Sand Cone Method Each 800.00 7 Field Density by Core-Cutter Method Each 400.00 418 | Voids Ratio Each 300.00 19 | Soundness of. Aggregate Each 2,000.00 20" | lngtion index (EN) Fach 30000 21 | kines index (1) sch) 20000 cick 2 | Water Absorption (6 Nos) Set 1,000.00 3 | Sie & Shape (Nos) se] stn00 4 | weight (vo) sar | 20000 ~[ orescence (Nos) se | 30000 Page 369 Name of Test D. CONCRETE: Compressive Strength Cylinder (Each set comprises with 3 specimen) Compressive Strength of Cube (Each set comprises with 3 specimen) | Concrete Gylinder Casting & Testing (Each set comprises with 3 specimen) | Concrete Cube Casting & Test prises with 3 specim: ‘Slump test Design of Concrete Mixes Impact of Hammer Test Core Cutter “ng Tote {i) Transportation TK.500/day E. Bitumen : 1 _| Softening Point (R&B) E ae Ae LACEY : = te a 4 | Loss-on-heating test ois, : fol S| Standard Penetration 7 - “6 | Core cutter ae = ‘) Cutting [ ii) Transportati ‘Bituminous material Test ') Sample Preparation (Each set comprises with 3 specimen.) 1) Stability & Flow i) Asphalt Mix Design Bitumen Extraction Shrinkage Limit Zou Sertakeas LS | Natural Moisture Content | Liquid Limit Plastic Limit “Unit weight Specific Gravity Sieve & Hydrometer combined Analysis +Specific glavity Sand equivalent test Void ratio Consolidation test Field Vane Shear Test for cohesive Soll Name of Test 1) Unconsolidated Untrained Direct Shear test ee Fach | 1,600.00 Bach [2,500.00 L ee 75 [nal Sear Tex | Uacnsldatd Unraned zach | _is0000] i const fen | 280000 on 150000 3.50000 16 | Permeability | Dcohesive 2,000.00 i) Non -Cohesive Each | 1,000.00 G. Sub-Soll Investigation: “Sub-soll exploration & testing to be executed according to the advice of design unit, LGED in regards tothe no. of bore hole, types &no, of laboratory test P 1 | Mobilization and demobilization of boring equipment such as drilling rig, drilling pipes. drop hammer, tripod, pulley, chain wrangle, sample collection | ‘devices tools and plants tripod for temporary camp.& arrangement for water Supply, other accessories and manpower at work site within 25 km from district head atrs. etc all complete and accepted by the Engineer. I aT visit and inspection of sampling by the Geo-tech. Expert/Engineer _| Persite | 3,678.69 Persite | 579639 | Erection and placement of boring equipment at site TVOn diy ground ae with 02.75m depth of water ias308 “IVA te wth wae depth betwen 075m ad 3 er point| 258267 site with water depth above 3m ~ [er point | 3.97400 Execution of Boring :Driling 100 mm dia bore-hole by wash boring method i) 0 109 meter )) 9 meter to 18 meter Execution of Standard Penetration Test 1) 0 9 meter : Per Point ii) 9 meter to 18 meter See Per Point | 10 meter to 27meter [Per Point iw) 27meter to 36 meter [Per Point ¥) 36 meter to 45 meter Per Point | i w)Above 45 meter [Per Point | | caneclon ot bisrbed Sepa Wevery Lim baer Werieon [Pers Collection of Undisturbed soil Samples by Shelby Tube from cohesive layer including preservation, transportation and accepted by the Engineer (ASTM .1587-83) Per Sample ae Name of Test Unit Rate Mapping & Reporting 1 Preparation of Topographic map ofthe site Preparation, writing and submission of report on sub-soll investigation containing 2. | all parameters, bearing capacities, x-sections, two or more sets of data ete. ll Complete as per satisfaction and direction of engineer in-charge Plate Load Test 7 | Plate load test mobilization, demobiliation arrangement of plates forloading and | Per test allother required materials, execution of tests recording the data preparation and submission of test report and accepted by the Engineer-in charge. | ‘Cone Penetration Test (CPT) 7] Hlectronic Gone Penetration Test with pore pressure measurement, dissipation test | Each | up to S0m depth to measure friction ange, un-drained shear strength, SPTIN6O, Relative density, pore pressure etc. Test on- ground surface 2 | sectronic Cone Penetration Test with pore pressure measurement, dissipation test up to 50m depth to measure friction angle, undrained shear strength, SPT N6O, Relative density, poe pressure etc. Test on- water Each H. Reinforcement 1 Tensile Strength (Bar dia up to 19mm) I T ‘Tensile Strength (Bar dia > 19mm - 40mm) 3 Bend (Bar dia up to 19mm) + Bend (Bar dia > 19mm - 40mm) |. Miscellaneous. 1 | Calibration of Pressure gauge 2 | calibration of Hydraulic jack without Pressure Gauge 3. | calbration of Hydraulic Jack with Pressure Gauge Calibration of Compre Calibration of Proving Ring Pile Integrity Test Bearing Pad 1 Hardness (ASTM D-2240) ii) Test of Compression Set for 22hr at 100°C (ASTM D-395) 1a) Ash Content vill) No. and thickness of Elastomer layer and Steel Plate In case of smaller works up to an estimated cost of 10,00,000.00 (Ten lac) for each Individual prescribed lab test frequency is not mandatory. The concerned Engineer can determine the test practical needs and demands and then perform those tests inthe field to ensure quality

You might also like