Viper Cable Charts and Wiring Diagrams
Viper Cable Charts and Wiring Diagrams
Viper Cable Charts and Wiring Diagrams
(V 5.4)
Program Version
The product described in this manual is computer based, and most functions are realised by software.
This manual corresponds to:
• Software Version CPU 5.4
It was released in May, 2006.
Product and Documentation Changes
Big Dutchman reserve the right to change this document and the product herein described without
further notice. In case of doubt, please contact Big Dutchman.
Latest date of change appears from the back page.
NOTE
• All rights reserved. No part of this manual may be reproduced in any manner whatsoever
without the expressed written permission of Big Dutchman in each case.
• Big Dutchman have made reasonable efforts to ensure the accuracy of the information
contained in this manual. Should any mistakes or imprecise information occur in spite of
this, Big Dutchman would appreciate being notified hereof.
• Irrespective of the above, Big Dutchman shall not accept any liability with regard to loss or
damage caused or alleged to be caused by reliance on any information contained herein.
• Copyright 2006 by Big Dutchman
IMPORTANT
NOTES CONCERNING THE ALARM SYSTEM
Where climatic control is used in livestock buildings, breakdowns, malfunctions or faulty settings may
cause substantial damage and financial losses. It is therefore most important to install a separate,
independent alarm system, which monitors the house concurrently with the climate computer.
According to EU-directive No. 91/629/EØF and 91/630/EØF an alarm system must be installed in any
house that is mechanically ventilated.
Please note that the product liability clause of Big Dutchman’s general terms and conditions of sale
and delivery specify that an alarm system must be installed.
In case of misoperation or improper use, ventilation systems can result in production loss
or cause loss of lives among animals.
Big Dutchman recommend that ventilation systems should be mounted, operated and
serviced only by trained staff and that a separate emergency opening unit and an alarm
system be installed as well as maintained and tested at regular intervals, according to Big
Dutchman’s terms and conditions of sale and delivery.
1 INTRODUCTION 7
3.4 Connection of Winch Motors for Air Intake or System with one Winch
Motor....................................................................................................... 24
3.4.1 CL 75A 24 V Winch Motor for Air Intake ................................................................... 24
3.4.2 Two CL 75A 24 V Decentralized Winch Motors for Air Intake in one House with
Intake in one Zone .......................................................................................................... 25
3.4.3 Six CL 75A 24 V Decentralized Winch Motors for Air Intake in one House with
Intake in three Zones...................................................................................................... 26
3.4.4 CL 75A 230 V Winch Motor for Air Intake ................................................................. 27
3.4.5 Joventa DAG 2.p1 Winch Motor for Air Intake .......................................................... 28
3.4.6 CL 74B Winch Motor for Air Intake ............................................................................ 29
3.4.7 Joventa DMG 1.1s Winch Motor for Air Intake.......................................................... 29
3.4.8 DA 20 Winch Motor for Air Intake............................................................................... 30
3.4.9 CL 74AV Stepless Winch Motor for Air Intake .......................................................... 31
3.4.10 Two CL 74B Decentralized Winch Motors for Air Intake.......................................... 32
1 INTRODUCTION
This document includes a collection of cable charts and wiring diagrams, which are to be used when
installing a Viper Climate and Production computer in any house. The document may therefore
contain sections that are not relevant to the specific house. In case of doubt, contact Big Dutchman
Service or your dealer.
The connection terminals in Viper Climate and Production computer are universal so that various
components can be connected to the individual terminals.
The connection may differ from the showed connection depending on which components are to be
connected. Therefore, the diagrams in this document must be considered examples.
The Viper Climate and Production computer installation menu (Technical/Setup/ Installation)
indicates precisely to which terminals a component must be connected. When the wiring diagrams
read, “See the setup menu Show installation”, it refers to the indications of the computer. See
also Technical Manual.
If a Big Dutchman wiring box has not been bought, it can be replaced by a locally manufactured
wiring box.
The installation must be made by an authorized electrician according to the current national
regulations and EU regulations.
DOL 12
HOUSE
Viper
DOL 14
DOL 12
DOL 12
HOUSE Viper
MC 278M
DOL 14
DOL 12
Viper
MC 278CT
= Junction box
NB Use min. 1 mm2 armoured installation cables everywhere, however min. 1.5mm2 for CL 75 24 V
R. Do not use any shrink-on sleeves.
CL 74AV stepless
Viper
CL 75A 24 V
CL 75A 230 V
DA 20
Joventa
DMG 1.1s
Joventa
DAG 2.p1
CL 74B
Viper
3-wire
Max. 6.8 A
Maximum 16 A MC 37
MC 23U
Maximum 3 × 10 A
Cooling
External cooling
Electronic differential
pressure sensor
Auxiliary sensor
2-wire
Max. 6.8 A
3-wire
Max. 16 A MC 37
MC 23U
Max. 3 × 10 A
Electronic
differential Curtain
pressure sensor
Auxiliary sensor
ON/OFF
relay heating
Cooling
CL 74AV
CL 74A ON/OFF
Inlet
CL 75A 24 V Viper
Inlet
min. 1.5 mm2
CL 75A 230 V
CL 75CT 230 V
Test
one-pole switch
Viper
Alarm system
Viper
DOL 12
Front2
TEST
one-pole switch
Viper
2
Use rigid wiring cable min. 1.5 mm .
Alarm system
Viper
DOL 12
TEST
one-pole switch
Viper
Viper
MC 278CT
Maximum 6.8 A
2-wire
3-wire
Maximum 6.8 A
Air outlet 1
CL 74AV
See Show
installation
Air outlet 1
CL 74AV
Viper
Air outlet 2
CL 74AV
See Show
installation
CL 75A 24 V
Air intake
Viper
Winch motor
CL 75A 24 V
Viper
CL 75A 230 V
Air intake
Viper
Air intake
Viper
CL 74B
Air intake
Viper
Air intake
Viper
DA 20
Viper
Air intake
BL = Blue
Br = Brown
S = Black
Air intake
CL 74AV
Viper BASIS MODULE
CL 74B CL 74B
Air intake
Viper
Air outlet 1
CL 74AV
Air outlet 1
CL 74AV
Viper
Air outlet 2
CL 74AV
CL 75A 24 V
Air outlet 1
Viper
CL 75A 230 V
Air outlet 1
Viper
Air outlet 1
Viper
CL 74B
Air outlet
Viper
Air outlet 1
Viper
Step 8
Step 7
Step 6
Step 5
Step 4
Step 3
Step 2
Step 1
Air outlet 1
CL 74AV
Stepless
MultiStep®
Viper
BL = Blue
BR = Brown
S = Black
Viper
Internal cooling
Cooled air
Air
Viper
External cooling
BL = Blue
BR = Brown
S = Black
Wind velocity
Wind direction
Swivel shutter
CL 74A
Cable
Fan
Recirculation motor
MC 37
MC 37. 230 V 16 A
Viper
Air Supply
Mount the fans for air supply in an external fan speed controller MC 37.
This diagram is an example of the typical connection. Connect it to the potentiometer of Air intake 1 .
MC 37
MC 37. 230 V 16 A
Viper
Air Intake
See the above diagrams 3.4.
Air Outlet
Connect the air outlet like an ordinary MultiStep®.
MC 37
MC 37. 230 V 16 A
Viper
Air Intake
See above diagrams 3.4.
Air Outlet
See above diagrams 3.5.
24-hour clock
Feeding system
Light
Water
Silo weighing
Silo auger
Silo auger
Cross auger
Silo weighing
24-hour clock
Feeding system
Light
Water
Silo auger
Silo auger
Cross auger
Dimmer
MS 41R
proximity
switch
Water meter
Poultry
weighers
Tip weigher
Silo 1
Silo 1 Silo 2
Silo 2
Silo 1
Silo 1 Silo 2
Silo 2
Switch and
contactor Viper/Wiring box
Weighing module
I/O-module
Viper
WB1600 or WB6000
load cells/weight bars
Weighing
module
Power module
MC 235/236
Data network
Viper
module
Weighing modulel
Power supply
Data network module
Viper
Loadcell schield
termination
Weigher
Poultry 2
weigher
Weigher
1
MS 41R
MS 41R
Water
Light
Feeding system
Cross auger
Wiring box
MS 45R
MS 45R sensor in the last pan
House
C
Viper