CHECK 

CRACK WIDTH ACCORDING TO ACI 224R‐EQ.4‐2a®

W=0.076 β Fs ( dc * A)^0.33
W=most probable maximum crack width (in)
β=ratio of distance between N.A and tension face to distance between N.A and RFT (y/y 1)
Fs=reinforcing steel service stress (KSI)
dc=thickness of cover from the extreme tension fiber to closest bar (in)
A=area of concrete symmetric with rienfocing steel divided by number of bar (in2)((b*2dc)/n)

b = 100 cm Es= 2100000 kg/cm2


t= 30 cm As= T  16 @ 75 2679.466667
dc= 5 1.968504 in As'= T  16 @ 150 1339.733333
d'= 5 cm fc'= 300 kg/cm
Mw= 6.5 m.t where, Sec. type Water‐Retaining Structure crack width limit
Tw= 0 t w= 0.0039 in SAFE
w= 0.09978 mm

d= 25 cm
Ec= 261539.7 kg/cm2
n=Es/Ec= 8.029375
Number of bars 13.33333
z= 8.119376 cm
Fc= 60.7272 kg/cm2
Fs= 1013.75 kg/cm2 14.1925 ksi
A= 75 cm2 11.62791 in2
β= 1.296198
26.79467 cm2
13.39733 cm2

0.004 in