CHECK 

CRACK WIDTH ACCORDING TO ACI 224R‐EQ.4‐2a®

W=0.076 β Fs ( dc * A)^0.33
W=most probable maximum crack width (in)
β=ratio of distance between N.A and tension face to distance between N.A and RFT (y/y 1)
Fs=reinforcing steel service stress (KSI)
dc=thickness of cover from the extreme tension fiber to closest bar (in)
A=area of concrete symmetric with rienfocing steel divided by number of bar (in2)((b*2dc)/n)

b = 100 cm Es= 2100000 kg/cm2


t= 30 cm As= T  16 @ 150 1339.733333
dc= 6.6 2.598425 in As'= T  16 @ 150 1339.733333
d'= 6.6 cm fc'= 300 kg/cm
Mw= 1.6 m.t where, Sec. type Water‐Retaining Structure crack width limit
Tw= 0 t w= 0.0035 in SAFE
w= 0.08824 mm

d= 23.4 cm
Ec= 261539.7 kg/cm2
n=Es/Ec= 8.029375
Number of bars 6.666667
z= 6.165529 cm
Fc= 24.79561 kg/cm2
Fs= 556.5243 kg/cm2 7.79134 ksi
A= 198 cm2 30.69767 in2
β= 1.382953
13.39733 cm2
13.39733 cm2

0.004 in