HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through Rate
as per (in Rs.)
schedule

49 Wiring for light point / fan point / exhaust fan / call bell point
with 1.5 Sq. mm. PVC insulated heat resistant flame retardant
(HRFR) and low smoke single core (flexible) copper conductor
cable in surface/recessed PVC conduit and earthing the light
point with 1.5 Sq.mm. HRFRLS/PVC insulated single core
copper conductor cable as required.

203 Group C. point 592.00


Add cost index @ 25% 148.00
Total:- 740.00
Add GST @12% 88.80
Total:- 828.80
Add 1% Labour cess 7.40
Total:- 836.00
50 Wiring for circuit/sub-main with following size PVC insulated
heat resistant flame retardant (HRFR) and low smoke single
core (flexible) copper conductor cable in surface/recessed
steel conduit along with 1 No.HRFRLS/PVC insulated single
core copper conductor cable of same size for earthing as
required
116 2x1.5 Sq. mm. Mtr. 162
Add cost index @ 25% 40.50
Total:- 202.50
Add GST @12% 24.30
Total:- 226.80
Add 1% Labour cess 2.03
Total:- 229.00
51 Wiring for power plug with 2x4 Sq. mm. PVC insulated heat Mtr. 213
resistant flame retardant (HRFR) and low smoke single core
(flexible) copper conductor cable in surface/recessed steel
conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated
single core copper conductor cable for earthing as required.

Add cost index @ 25% 53.25


Total:- 266.25
Add GST @12% 31.95
Total:- 298.20
Add 1% Labour cess 2.66
Total:- 301.00
52 Supplying and fixing of following way, single pole and
neutral sheet steel MCB distribution board, 240 volts, on
surface / recess, complete with tinned copper bus- bar, wire-set,
neutral link, earth bar, din-bar, detachable gland plate, blanking
plate, cable, identification labels interconnections, phosphatized
and powder painted, including earthing etc. as required:-

1803 Single door-8 way Each 644.00


Add cost index @ 25% 161.00
Total:- 805.00
Add GST @12% 96.60
Total:- 901.60
Add 1% Labour cess 8.05
Total:- 910.00
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through Rate
as per (in Rs.)
schedule

53 930 Supplying and fixing plain pendent with 16/0.20 mm twin Each 129
twisted,
flexible, PVC insulated, cotton braided, copper cable and brass
pendent holder including connections etc. as required:-

Add cost index @ 25% 32.25


Total:- 161.25
Add GST @12% 19.35
Total:- 180.60
Add 1% Labour cess 1.61
Total:- 182.00
54 Providing and fixing shock proof slim decorative extruded
fixture with domestic electronic ballast, suitable for 36 watt
FTL (T8), complete with all accessories (excluding the T-8
Tube), connections, testing and commissioning etc. as required

2609 1 x36 watt-FTL(T8) (Category-A) Each 646


Add cost index @ 25% 161.50
Total:- 807.50
Add GST @12% 96.90
Total:- 904.40
Add 1% Labour cess 8.08
Total:- 912.00
55 Providing, Installation, testing and commissioning of ceiling fan
with regulator, including wiring the down rods of standard length
(up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton
braided, copper cable, including providing and fixing phenolic
laminated sheet cover on the fan box and earthing etc. as
required:-

2501 Ceiling Fan 1200 mm sweep, Category-A


Each 1548.00
Add cost index @ 25% 387.00

Total:- 1935.00
Add GST @12% 232.20

Total:- 2167.20
Add 1% Labour cess 19.35
Total:- 2187.00

56 Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity,


240 volts, 'C' curves, miniature circuit breaker of following poles in the
existing MCB DB complete with connections etc. as required:-

1709 Double pole. Cat-A. Each 652.00


Add cost index @ 25% 163.00
Total:- 815.00
Add GST @12% 97.80
Total:- 912.80
Add 1% Labour cess 8.15
Total:- 921.00
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through Rate
as per (in Rs.)
schedule

57 Supplying and erection of 6 amps. to 32 amps. rating, 10 KA


breaking capacity, 240 volts, 'C' curves, miniature circuit
breaker of following poles in the existing MCB DB complete
with connections etc. as required:-

1701 Single pole. Cat-A. Each 153


Add cost index @ 25% 38.25
Total:- 191.25
Add GST @12% 22.95
Total:- 214.20
Add 1% Labour cess 1.91
Total:- 216.00

58 Supplying and fixing following rating, double pole, 240 volts, isolator in the
existing MCB DB complete with connections, testing and commissioning etc.
as required.
1716 40 Amps. Cat-A. Each 323
Add cost index @ 25% 80.75
Total:- 403.75
Add GST @12% 48.45
Total:- 452.20
Add 1% Labour cess 4.04
Total:- 456.00

Executive Engineer,
IPH Division Thunag
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through
as per Rate (in Rs.)
schedule

102 Wiring for light point / fan point / exhaust fan / call bell point
with 1.5 Sq. mm. PVC insulated heat resistant flame
retardant (HRFR) and low smoke single core (flexible) copper
conductor cable in surface/recessed PVC conduit and
earthing the light point with 1.5 Sq.mm. HRFRLS/PVC
insulated single core copper conductor cable as required.

203 Group C. point 592.00


Add cost index @ 25% 148.00
Total:- 740.00
Add GST @12% 88.80
Total:- 828.80
Add 1% Labour cess 7.40
Total:- 836.00

103 213 Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat Meter 96.00
resistant flame retardant (HRFR) and low smoke single core
(flexible) copper conductor cable in surface/recessed PVC
conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated
single core copper conductor cable for earthing as required.

Add cost index @ 25% 24.00


Total:- 120.00
Add GST @12% 14.40
134.40
Add 1% Labour cess 1.20
Total:- 136.00
104 214 Wiring for power plug with 2x4 Sq. mm. PVC insulated heat Meter 148.00
resistant flame retardant (HRFR) and low smoke single core
(flexible) copper conductor cable in surface/recessed PVC
conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated
single core copper conductor cable for earthing as required.

Add cost index @ 25% 37.00


Total:- 185.00
Add GST @12% 22.20
Total:- 207.20
Add 1% Labour cess 1.85
Total:- 209.00
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through
as per Rate (in Rs.)
schedule

105 Supplying & fixing metal box of following sizes (nominal size)
on surface or in recess suitable for fixing phenolic laminated
sheet cover in front including painting etc. as required:-

105.01 803 200mm.x150mm.x75mm. deep Each 81.00


Add cost index @ 25% 20.25
Total:- 101.25
Add GST @12% 12.15
Total:- 113.40
Add 1% Labour cess 1.01
Total:- 114.00
105.02 802 180mm.x100mm.x60mm. deep each 68.00
Add cost index @ 25% 17.00
Total:- 85.00
Add GST @12% 10.20
Total:- 95.20
Add 1% Labour cess 0.85
Total:- 96.00
106.00 905 5 pin 5/ 6 Amps socket outlet, porcelain base/ piano type. each 31.00
Add cost index @ 25% 7.75
Total:- 38.75
Add GST @12% 4.65
Total:- 43.40
Add 1% Labour cess 0.39
Total:- 44.00
107.00 906 6 pin 15/16 Amps socket outlet, porcelain base/ piano type. each 58.00

Add cost index @ 25% 14.50


Total:- 72.50
Add GST @12% 8.70
Total:- 81.20
Add 1% Labour cess 0.73
Total:- 82.00
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through
as per Rate (in Rs.)
schedule

108.00 Supplying and fixing following rating Piano-type switch


/socket on the existing switch box / cover including
connections etc. as required.
108.01 901 S.P. 5/ 6 Amps one way switch, piano type. each 23.00
Add cost index @ 25% 5.75
Total:- 28.75
Add GST @12% 3.45
Total:- 32.20
Add 1% Labour cess 0.29
Total:- 32.00
108.02 903 Bell push, piano type. each 24.00
Add cost index @ 25% 6.00
Total:- 30.00
Add GST @12% 3.60
Total:- 33.60
Add 1% Labour cess 0.30
Total:- 34.00
108.03 904 S.P. 15/16 Amps one way switch, porcelain base/ piano type. each 49.00

Add cost index @ 25% 12.25


Total:- 61.25
Add GST @12% 7.35
Total:- 68.60
Add 1% Labour cess 0.61
Total:- 69.00
109.00 Providing, Installation, testing and commissioning of ceiling
fan with regulator, including wiring the down rods of standard
length (up to 30 cm) with 16/0.20 mm twin twisted flexible,
cotton braided, copper cable, including providing and fixing
phenolic laminated sheet cover on the fan box and earthing
etc. as required:-

2501 Ceiling Fan 1200 mm sweep, Category-A each 1548.00


Add cost index @ 25% 387.00
Total:- 1935.00
Add GST @12% 232.20
Total:- 2167.20
Add 1% Labour cess 19.35
Total:- 2187.00
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through
as per Rate (in Rs.)
schedule

110.00 Providing and installation of stationary storage type Electric


water heater (Geyser) of various sizes by means of
Expansion-bolts with nuts and washers, including embedding
of expansion-bolts in the wall, providing and fixing of Non-
return valve, Dead weight safety valve, 2 No C.P. connection
rods 18" long, making good the damages, electrical
connections, safety valve connections, testing and
commissioning etc. as required:-

110.01 2406 25 Liter capacity water heater (Cat-B) each 7126.00


Add cost index @ 25% 1781.50
Total:- 8907.50
Add GST @12% 1068.90
Total:- 9976.40
Add 1% Labour cess 89.08
Total:- 10065.00
110.02 2402 6 Liter capacity water heater (Cat-B) each 5148.00
Add cost index @ 25% 1287.00
Total:- 6435.00
Add GST @12% 772.20
Total:- 7207.20
Add 1% Labour cess 64.35
Total:- 7272.00
Providing and installation of exhaust fan of following sizes in
the existing opening, including making the hole to suit the
size of the above fan, making good the damages,
connections, testing and commissioning etc. as required:-

111 2505 Exhaust Fan, Heavy duty, 300 mm sweep each 2596.00
Add cost index @ 25% 649.00
Total:- 3245.00
Add GST @12% 389.40
Total:- 3634.40
Add 1% Labour cess 32.45
Total:- 3667.00
112 942 Installation, testing and commissioning of pre-wired, each 49.00
fluorescent light fitting/ compact fluorescent fitting of all types
complete with all accessories and tubes etc. directly on
ceiling/wall, including connections with 16/0.20 mm twin
twisted flexible, cotton braided, copper cable and earthing
etc. as required:-
Add cost index @ 25% 12.25
Total:- 61.25
Add GST @12% 7.35
Total:- 68.60
Add 1% Labour cess 0.61
Total:- 69.00
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through
as per Rate (in Rs.)
schedule

113.00 2711 Supplying and fixing of bulk head fitting of all sizes and
shapes, containing one No. thread type CFL lamp holder (s),
complete with all accessories but excluding CFL lamp
including making connections, testing etc. as required.

113.01 Bulk head fitting, CFL type (Category-A) each 385.00


Add cost index @ 25% 96.25
Total:- 481.25
Add GST @12% 57.75
Total:- 539.00
Add 1% Labour cess 4.81
Total:- 544.00
114.00 Supplying and fixing of fancy wall bracket containing thread
type CFL lamp holder (s) of all sizes and shapes, complete
with all accessories but excluding CFL lamp including making
connections, testing etc. as required.
114.01 2701 Fixed type wall bracket 150 dia, single lamp.(Category-A) each 533.00
Add cost index @ 25% 133.25
Total:- 666.25
Add GST @12% 79.95
Total:- 746.20
Add 1% Labour cess 6.66
Total:- 753.00
114.02 2705 Mirror light 460 mm, single lamp.(Category-A)
each 533.00
Add cost index @ 25% 133.25
Total:- 666.25
Add GST @12% 79.95
Total:- 746.20
Add 1% Labour cess 6.66
Total:- 753.00
115.00 933 Supplying and fixing bakelite batten/angle holder including each 32.00
connections etc. as required:-
Add cost index @ 25% 8.00
Total:- 40.00
Add GST @12% 4.80
Total:- 44.80
Add 1% Labour cess 0.40
Total:- 45.00
116.00 937 Supplying and fixing Ding-Dong / Electronic musical bell, each 143.00
suitable for D.C./A.C. single phase,230 volts complete as
required:-
Add cost index @ 25% 35.75
Total:- 178.75
Add GST @12% 21.45
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through
as per Rate (in Rs.)
schedule

Total:- 200.20
Add 1% Labour cess 1.79
Total:- 202.00
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through
as per Rate (in Rs.)
schedule

117.00 Supplying and fixing of following sizes of PVC conduit along


with the accessories in surface / recess including cutting the
wall and making good the same in case of recessed conduit
as required:-

601 20 mm. dia Meter 49.00


Add cost index @ 25% 12.25
Total:- 61.25
Add GST @12% 7.35
Total:- 68.60
Add 1% Labour cess 0.61
Total:- 69.00
118.00 Supplying and fixing following rating, double pole (single
phase & neutral) 240 volts, residual current circuit breaker
(RCCB), having a sensitivity current up to 300 miliampers in
the existing MCB DB complete with connections, testing and
commissioning etc. as required.

118.01 1726 25 Amps. Cat-A. each 1664.00


Add cost index @ 25% 416.00
Total:- 2080.00
Add GST @12% 249.60
Total:- 2329.60
Add 1% Labour cess 20.80
Total:- 2350.00
119.00 1901 Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, Set 2679.00
including accessories and providing masonry enclosure with
cover plate having locking arrangement and watering pipe
etc. ( but without charcoal or coke and salt ) complete as
required.

Add cost index @ 25% 669.75


Total:- 3348.75
Add GST @12% 401.85
Total:- 3750.60
Add 1% Labour cess 33.49
Total:- 3784.00
120.00 1902 Extra for using salt and charcoal for pipe earth electrode Set 904.00
complete as required.
Add cost index @ 25% 226.00
Total:- 1130.00
Add GST @12% 135.60
Total:- 1265.60
Add 1% Labour cess 11.30
Total:- 1277.00
121.00 1909 Supplying and laying 6 SWG G.I. wire at 0.50 mtr. below Meter 24.00
ground level for earth electrode conductor, including
soldering etc. as required.
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through
as per Rate (in Rs.)
schedule

Add cost index @ 25% 6.00


Total:- 30.00
Add GST @12% 3.60
Total:- 33.60
Add 1% Labour cess 0.30
Total:- 34.00
122.00 Wiring for circuit / sub-main with following size PVC insulated
heat resistant flame retardant (HRFR) and low smoke single
core (flexible) copper conductor cable in PVC casing &
capping along with 1 No.HRFRLS/PVC insulated single core
copper conductor cable of same size for earthing as required.

122.01 314 2x10 Sq. mm. Meter 253.00


Add cost index @ 25% 63.25
Total:- 316.25
Add GST @12% 37.95
Total:- 354.20
Add 1% Labour cess 3.16
Total:- 357.00
122.02 313 2x6.0 Sq. mm. Meter 168.00
Add cost index @ 25% 42.00
Total:- 210.00
Add GST @12% 25.20
Total:- 235.20
Add 1% Labour cess 2.10
Total:- 237.00
HPSR-2009

Sr. No. Item code Abbreviated Nomenclature / Description of items Units Through
as per Rate (in Rs.)
schedule

122.03 312 2x4.0 Sq. mm. Meter 117.00


Add cost index @ 25% 29.25
Total:- 146.25
Add GST @12% 17.55
Total:- 163.80
Add 1% Labour cess 1.46
Total:- 165.00
310 2x1.5 Sq. mm. Meter 66.00
Add cost index @ 25% 16.50
Total:- 82.50
Add GST @12% 9.90
Total:- 92.40
Add 1% Labour cess 0.83
Total:- 93.00

Supplying and fixing of following way, single pole and


neutral sheet steel MCB distribution board, 240 volts, on
surface / recess, complete with tinned copper bus- bar, wire-
set, neutral link, earth bar, din-bar, detachable gland plate,
blanking plate, cable, identification labels interconnections,
phosphatized and powder painted, including earthing etc. as
required:-

123.00 1803 Single door-8 way each 644.00


& Add cost index @ 25% 161.00
Total:- 805.00
Add GST @12% 96.60
Total:- 901.60
Add 1% Labour cess 8.05
Total:- 910.00

Executive Engineer
IPH Division Thunag
HPSR-2009

117 Supplying and fixing of following sizes of PVC conduit along


with the accessories in surface / recess including cutting the
wall and making good the same in case of recessed conduit
as required:-

601 20 mm. dia Meter 49.00

Add GST @12% 5.88


54.88
Add 1% Labour cess 0.49
Total:- 55.00
105 Supplying & fixing metal box of following sizes (nominal size)
on surface or in recess suitable for fixing phenolic laminated
sheet cover in front including painting etc. as required:-

105.01 803 200mm.x150mm.x75mm. deep each 81.00

Add GST @12% 9.72


90.72
Add 1% Labour cess 0.81
Total:- 92.00
106 802 180mm.x100mm.x60mm. deep each
68.00
Add GST @12% 8.16
76.16
Add 1% Labour cess 0.68
Total:- 77.00

Page 30
HPSR-2009

Through Rate
Item No Abbreviated Nomenclature / Description of items Units
(in Rs.)
Supplying and fixing following rating Piano-type switch /socket
on the existing switch box / cover including connections etc. as
required.

108.01 901 S.P. 5/ 6 Amps one way switch, piano type. each 23.00

Add GST @12% 2.76

25.76

Add 1% Labour cess 0.23

Total:- 26.00

108.02 903 Bell push, piano type. each 24.00

Add GST @12% 2.88

26.88

Add 1% Labour cess 0.24

Total:- 27.00

108.03 904 S.P. 15/16 Amps one way switch, porcelain base/ piano type. each 49.00

Add GST @12% 5.88


54.88
Add 1% Labour cess 0.49
Total:- 55.00
106 905 5 pin 5/ 6 Amps socket outlet, porcelain base/ piano type. each 31.00

Add GST @12% 3.72


34.72
Add 1% Labour cess 0.31
Total:- 35.00
107 906 6 pin 15/16 Amps socket outlet, porcelain base/ piano type. each 58.00

Add GST @12% 6.96


64.96
Add 1% Labour cess 0.58
Total:- 66.00
115 933 Supplying and fixing bakelite batten/angle holder including each 32.00
connections etc. as required:-

Add GST @12% 3.84


35.84
Add 1% Labour cess 0.32
Total:- 36.00
116 937 Supplying and fixing Ding-Dong / Electronic musical bell, each 143.00
suitable for D.C./A.C. single phase,230 volts complete as
required:-

Add GST @12% 17.16


160.16
Add 1% Labour cess 1.43
Total:- 162.00
112 942 Installation, testing and commissioning of pre-wired, fluorescent each 49.00
light fitting/ compact fluorescent fitting of all types complete with
all accessories and tubes etc. directly on ceiling/wall, including
connections with 16/0.20 mm twin twisted flexible, cotton
braided, copper cable and earthing etc. as required:-

Add GST @12% 5.88


54.88
Add 1% Labour cess 0.49

Page 36
HPSR-2009

Total:- 55.00

Page 37
HPSR-2009

Through Rate
Item No Abbreviated Nomenclature / Description of items Units
(in Rs.)
118 Supplying and fixing following rating, double pole (single
phase & neutral) 240 volts, residual current circuit breaker
(RCCB), having a sensitivity current up to 300 miliampers in
the existing MCB DB complete with connections, testing and
commissioning etc. as required.

118.01 1726 25 Amps. Cat-A. each 1664.00


Add GST @12% 199.68
1863.68
Add 1% Labour cess 16.64
Total:- 1880.00
123 Supplying and fixing of following way, single pole and
neutral sheet steel MCB distribution board, 240 volts, on
surface / recess, complete with tinned copper bus- bar, wire-
set, neutral link, earth bar, din-bar, detachable gland plate,
blanking plate, cable, identification labels interconnections,
phosphatized and powder painted, including earthing etc. as
required:-

123 1803 Single door-8 way each 644.00

Add GST @12% 77.28


721.28
Add 1% Labour cess 6.44
Total:- 728.00

Page 68
HPSR-2009

119 1901 Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, Set 2679.00
including accessories and providing masonry enclosure with
cover plate having locking arrangement and watering pipe etc.
( but without charcoal or coke and salt ) complete as required.

Add GST @12% 321.48


3000.48
Add 1% Labour cess 26.79
Total:- 3027.00
120 1902 Extra for using salt and charcoal for pipe earth electrode Set 904.00
complete as required.
Add GST @12% 108.48
1012.48
Add 1% Labour cess 9.04
Total:- 1022.00
121 1909 Supplying and laying 6 SWG G.I. wire at 0.50 mtr. below Meter 24.00
ground level for earth electrode conductor, including soldering
etc. as required.

Add GST @12% 2.88


26.88
Add 1% Labour cess 0.24
Total:- 27.00

Page 74
HPSR-2009

Providing and installation of stationary storage type Electric


water heater (Geyser) of various sizes by means of
Expansion-bolts with nuts and washers, including
embedding of expansion-bolts in the wall, providing and
fixing of Non-return valve, Dead weight safety valve, 2 No
C.P. connection rods 18" long, making good the damages,
electrical connections, safety valve connections, testing and
commissioning etc. as required:-

2402 10 Liter capacity water heater (Cat-B) each 5148.00


Add GST @12% 617.76
5765.76
Add 1% Labour cess 51.48
Total:- 5817.00
2406 25 Liter capacity water heater (Cat-A) each 7126.00
Add GST @12% 855.12
7981.12
Add 1% Labour cess 71.26
Total:- 8052.00
Providing, Installation, testing and commissioning of ceiling
fan with regulator, including wiring the down rods of standard
length (up to 30 cm) with 16/0.20 mm twin twisted flexible,
cotton braided, copper cable, including providing and fixing
phenolic laminated sheet cover on the fan box and earthing
etc. as required:-

2501 Ceiling Fan 1200 mm sweep, Category-A each 1548.00


Add GST @12% 185.76
1733.76
Add 1% Labour cess 15.48
Total:- 1749.00
Providing and installation of exhaust fan of following sizes in
the existing opening, including making the hole to suit the
size of the above fan, making good the damages,
connections, testing and commissioning etc. as required:-
2505 Exhaust Fan, Heavy duty, 300 mm sweep each 2596.00

Add GST @12% 311.52


2907.52
Add 1% Labour cess 25.96
Total:- 2933.00
Supplying and fixing of fancy wall bracket containing thread
type CFL lamp holder (s) of all sizes and shapes, complete
with all accessories but excluding CFL lamp including
making connections, testing etc. as required.
2701 Fixed type wall bracket 150 dia, single lamp.(Category-A) each 533.00
Add GST @12% 63.96
596.96
Add 1% Labour cess 5.33
Total:- 602.00
Supplying and fixing of fancy wall bracket containing thread
type CFL lamp holder (s) of all sizes and shapes, complete
with all accessories but excluding CFL lamp including
making connections, testing etc. as required.
2705 Mirror light 460 mm, single lamp.(Category-A) each 533.00

Page 84
HPSR-2009

Add GST @12% 63.96


596.96
Add 1% Labour cess 5.33
Total:- 602.00
2711 Supplying and fixing of bulk head fitting of all sizes and
shapes, containing one No. thread type CFL lamp holder (s),
complete with all accessories but excluding CFL lamp
including making connections, testing etc. as required.

Bulk head fitting, CFL type (Category-A) each 385.00

Add GST @12% 46.20

Page 85