Download as pdf
Download as pdf
You are on page 1of 1
Plumbing Symbols and Abbreviations PIPING SYSTEMS LABELS WATER PIPING SYSTEMS: GAS AND AIR PIPING SYSTEMS: —scw— COLD SOFT WATER ——A— _cOWPRESSED AIR —-—— cowater —#2— _HypRoGEN FIRE PROTECTION —c— NaTsRALaS. HOT WATER —12— NITROGEN HOT WATER RETURN —vae— _vaCuUM (air) NON-FOTABLE WATER ‘TEMPERED WATER REVERSE OSMOSIS WATER WASTE AND VENT SYSTEMS: SITE PIPING SYSTEMS: — cD — _ CONDENSATE DRAIN —F—— FIREMAN —cw— CLEARWATER VENT Fv FORCE MAIN —cwe— CLEARWATER WASTE SAN SANITARY SEWER —Fw— _ FoRCEMAIN — st — stor sewer —w— _noRect waste —w— _ warer une ——00— OVERFLOW DRAINLINE —(©)SAN— _BXISTING SANITARY —stT— storm —SS0— SUBSOILDRAINLINE — — —_ UNDERFLOOR FOR WASTE OR SOIL, SUBSOL, STORM & FORCE MAIN, —---- ver —SAN—— _WASTEOR SOIL LINE NOTE: (E) PRIOR TO SYSTEM TYPE DENOTES EXISTING PIPING (F) PRIOR TO SYSTEM TYPE DENOTES FUTURE PIPING PIPE FITTINGS ——+5 =LB0WDOWN ——40 L0WwUP —+6+— TEEDOWN —+0+1— TEEUP J} ripe car —D—_ CONCENTRIC REDUCER — ‘VALVE IN VERTICAL ++ TEE BRANCH +H (DOUBLE WE ——+4 __uneconminuaTion BREAK HT We ——S_ PLuweino Four stors +11 WE WH VENT UP —15+-— PIPELINE STRAINER DRAINS AND CLEANOUTS o FLOOR DRAIN on FIXTURE WASTE TRAP rr) FLOOR SINK —4co — CLEANOUT ° HUB DRAIN FCO@— —- FLOORCLEANOUT @ FLOOR SINK PIPING VALVES AND SPECIALTIES b— ANGLE VALVE —L— arvent. autowaric hw —KD}—_—satancins vate (AIR VENT, MANUAL, —6-—_—s BAL VALVE —pdSRba BACKFLOW PREVENTER i BUTTERALY VALVE ° ‘CONSTANT FLOW REGULATOR = 43 DEMOLITION OF PING. Rs cecx ave eee —— owmrouvare —— _orecrion or Row t— DRAIN VALVE = arectionor prc rise (a) OR DROP (0) —ge— _FLosT oeraTeD VALVE - DRAIN PLUS —+—_. (GAS SHUTOFF VALVE sf EXPANSION JOINT —we— GATE VALVE. REI — _FLEXIELE CONNECTION —— cose lve es = FLOW SWITCH gr Puc vave Delp FLOWSENSING DEVICE Ply ——P4— _POSTINDICATOR VALVE —— — _ casREGULATOR —p— PRESSURE REDUCING VALVE 4 GAS OUTLET th presoune RELIEF VANE Xy Hosea eR auick orENING VALVE —t— pxreseus —p<— _ sHurorrvatve a Pa QUICK OFENING VALVE —4 serespus —pa— sHuTorr vALvE Q —1 PRESSURE GAUGE —L— scenoovare a Des ——l— pressure swrto —B—_ TRIFLEDUTY VALVE Sx ‘STEAM TRAP es ‘2AVAY CONTROL VALVE (VALVE _ BODY AS SPECIFIED) ——L— _ tervonerer t= SAY MIXING VALVE WH WALL HYDRANT . =~ 42 VAY VALVE WITH ARROW INDICATING |AMMER ARRESTOR: ~ FAIL POSITION WATER — = ‘VALVE IN BOX cS) PLUMBING ABBREVIATIONS AB ABOVE MAK MAXIMUM ACE ACCESS MB MOP BASIN: ADL ADJUSTABLE MBH THOUSANDS OF BTU PER HOUR AEF ROVE FINISHED FLOOR NG EGHANIGAL GONTRAGTOR AFG ABOVE FINISHED GRADE Nica WINMIUM CIRCUIT AMPACITY ALT ALTERNATE NCC WOTOR CONTROL CENTER AP ACOESS PANEL NEP ——_WECHANICAL, ELECTRICAL ABPROX, APPROXIMATELY AND eIPING ARCH ARCHITECTURAL MER MECHANICAL EQUIPMENT ROOM: ASSY ASSEMBLY ‘MEZZ MEZZANINE AVG AVERAGE VFR MANUFACTURER wi MANHOLE BFF BELOW FINISHED FLOOR win viva alos = BULOING Wisc —_WISCELLANEOUS sor BOTTOM ID WOUNTED BOP BOTTOM OF PIPE MIG MOUNTING: or BATHTUB BTU BRITISH THERMAL UNITS NA NOT APPLICABLE BTUH BRITISH THERMAL UNITS NIG NOT IN GONTRAGT PER HOUR NO. NUMBER Bw BETWEEN Nes NOWINAL PIRE SIZE NPSH NET POSTIVE SUCTION HERD cae CEILING ACCESS PANEL NeT NATIONAL PIPE THREAD cre] CONTRACTOR FURNISHED, NR NEAR CONTRACTOR INSTALLED NTS NOTTOSCALE CoH USI FEET PER MINUTE CF CUBIC FEETPER HOUR oc ON CENTER cl CENTERLINE 00 OUTSIDE DIAMETER: cis ceILNG FO OWNERFURNSHED, CONTRACTOR CMU CONCRETE MASONRY UAIT INSTALLED co CLEANOUT OFOL —_GWNERFURMSHED, OWNER COND CONDUCTOR INSTALLED CONT CONTRACTOR OP OVERLOAD PROTECTION: COP COEFFICIENT OF ov OUTLET VELOCITY PERFORMANCE CIR CENTER P Pune cw COPPER °c PLUMBING CONTRACTOR cur COLD WATER PCF BOUNDS PER CUBIC FOGT CHU COLD WATERFDKTURE UMTS 70 PRESSURE DROP PH PHASE oo DRAIN DECK on POST INDICATOR VALVE DEG DEGREES: PLBG ‘PLUMBING DT ETAL Poo —_POINTOF CONNECTION DFU DRAINAGE FIXTURE UNIFS = POLYPROPYLENE oa DIAMETER PPH POUNDS PER HOUR Dit DIMENSION PRY PRESSURE RELIEF VALVE on Own PSF BOUNDS PER SQUARE FOOT os DowksPoUT 3 POUNDS PER SQUARE INCH or DRAIN TILE PSIA POUNDS PER SQUARE INCH ABSOLUTE OWG. DRAWING PSIG POUNDS PER SQUARE INCH GAUGE PVC POLYVINYL CHLORIDE E EXISTING Ex ERCH aa RADIUS ec ELECTRICAL CONTRACTOR RCP REINFORCED CONCRETE PIPE EEW EMERGENCY EVEWASH = ROOF DRAIN EFF, EFFICIENCY: ‘REC RECESSED a EXPANSION JOINT RECPT RECEPTACLE ELEC ELECTRICAL REQD REQUIRED ELEY ELEVATION RF ROOF ew EMERGENCY al ROUGHN Fue EQUIPMENT Re REVOLUTIONS PER MINUTE es EMERGENCY SHOWER RPZ ‘REDUCED PRESSURE ZONE VALVE ef EXPANSION TANK Rv RELIEF VALVE ETR EXIST TO REMAIN Ewe ELECTRIC WATER COOLER s ‘SLOPE EWH —_ELECTRICWATER HEATER Sch SCHEDULE WT ENTERING WATER SOR ‘STANDARD DIMENSION RATIO TEMPERATURE = SHOWER BH BRiAUST ST SHEET EXP EXPANSION 50S SLABONGRADE est XIsTING SPEC SPECIFICATION xT EXTERIOR sa ‘SQUARE ss SERVICE SINK F FUTURE Ss STAINLESS STEEL FCO FLOOR GLEANOUT STD STANDARD fo FLOOR DRAIN STRU STRUCTURAL FFE _ FINISHED FLOOR ELEVATION FLA —-FULLLOADANPS TeP TEMPERATURE AND PRESSURE FIR FLOOR TBR TOBEREMOVED Fu FACTORY MUTUAL 2 TRENCH ORAN Fe FIREPROOF TOFU TOTAL DRAIN FIXTURE UNITS FRM FEET PER MINUTE TEMP TEMPERATURE FPS. FEET PER SECOND TOB TOP OF BEAM FRT ——FLORT AND THERWOSTATIC ToD TOP OF DUCTIBECK fr reer Tol TOR OFolsT FTO FOOTING TOP TOP OF IPE Fu FDCTURE UNITS jos TOPOFSLAB TSTAT THERMOSTAT oA Gauge TWEU TOTAL WATER FIXTURE UNITS GAL GALLON TYP TYPIGAL GALV GALVANIZED oy GENERAL CONTRACTOR UNO UNLESS OTHERWISE NOTED GPM GALLONS PER MINUTE GPH GALLONS BER HOUR v vent vel veLociry 6 Hose olba wie VALVE I a0x HD HUB DRAIN vou VOLUME iP HORSE POWER He. HIGH POINT HVAC HEATING. VENTILATING & w wiDTH AIR CONDITIONING wi wir wr HOT WATER: wo WITHOUT Hieu HOT WATER FDCTURE UNITS ne WATER COLUMN WSFU WATER SUPALY FRCTURE UNITS ID INSIDE DIAMETER We WATER GAUGE i INVERT ELEVATION IN INGHES Ko KvockouT L LavaTORY Las, POUNDS | LBIHR POUNGS PER HOUR, Lr LINEAR FEET iP LOW PONT ur LUGHTING LWT LEAVING WATER TEMPERATURE

You might also like