Professional Documents
Culture Documents
Thyssenkrupp Elevator: Field Maintenance
Thyssenkrupp Elevator: Field Maintenance
Thyssenkrupp Elevator: Field Maintenance
.JUTVCJTIJ Elevator
7'(- Field Maintenance
Mitsubishi VFGL
Mitsubishi VFEL
2. LED “60” must be OFF and “MNT” LED
must be ON
3. Run the lift UP & DN trough the “UP-DN”
Switch On the right side panel above the
MCB
Checking the Safety Circuit
1. Drawing code “SF-0X” is for safety cct drawing
2. The code G012 or G0XX is the group code,
in which you can find where the connection is
located or going to
3. Safety circuit are 110 VDC
3. Check the safety point in the Terminal Block (TB)
according to the SF-XX Drawing or in the connector.
refer to connector list in the back of CP Door.
4. Check the check point as below :
0 0 0 B Brake Checking
Notes :
5= SD Contactor Monitoring
DZ Door Zone
60 Automatic Operation
1) JUMPER PLUGS
0 : LOCATION INSERTED THE PLUGS
P1
KCD-91X
JPCL
WITH CL-ROM O
JPS=S E1
KCH-945
STPP - 8
LTB - 8
NLWT -
BLWT -
SHIFT - 8
DNSH - 8
WGHG - 8
WGHO - 8
[NOTES]
1 DO NOT SET THE TOGGLE SWITCH "R/M-FWR"TO
THE FWR SIDE.
2 ADJUST ROTARY SWITCH "SET 1/0 & 0/8", "MON 1/0 & 0/8"
AND TOGGLE SWITCH "R/M-FWR" TO THE R/M SIDE WHEN
ELEVATOR IS HANDED OVER.
D
I SW
LOAD WEIGHING
LD0/LD MON FUNCTION
2
ADJUSTMENT(Contd…)
I SW
LOAD WEIGHING
LD0/LD MON FUNCTION
5
ADJUSTMENT(Contd…)
I SW
LOAD WEIGHING
PDSET( STORE FLOOR HEIGHT DATA)
Run the Elevator with low speed and stop the elevator
at bottom floor levelling zone.Press DCB.SPA button,the display
on p1 board will blink. Now, run the elevator fom bottom floor
to top floor with low speed ( no stop at half way). After elevator
car stop at top floor, display on P1 board will stop blinking and
will display the top floor’s number. PDSET is completed( see the
following procedure)
Elevator Filed Maintenance 35
NOMENCLATURE (CONTD..)
Group No. Code Application
G154 ACL10 G024 ACL1 OUTSIDE CONTROL PANEL
G157 RADX WITHOUT RADIATOR
G158 RADX WITTH RADIATOR(HYD. ELEVATOR ONLY)
G159 RADA G158 (HYD ONLY)
G160 60HZ 50 HZ (HYD ONLY)
G161 50HZ 60HZ (HYD ONLY)
G162 HOFF WITH POWER SUPPLY ONLY FOR DESIG
NATED FLOOR DURING FE
G163 HOFFX WITH POWER SUPPLY FOR ALL FLOORS
DURING FE
G164 FESO G196 PHASE-1 < G196 WITH 2ND
PHASE-1 KEY SW>
G165 HKDX G014 NOT DISABLED LIFT FOR HK
G166 HKD DISABLED LIFT FOR HK
G167 SHBT IU ONLY
G170 EER3X G091 (JAPAN ONLY)
G171 EER3X G091 (JAPAN ONLY)
G172 MA G091 (JAPAN ONLY)
G174 FERAX G100 WITHOUT KEY SW.AUTO POS
G175 FERA G100 WITH KEY SW.AUTO POS
G178 EERD WITH EER-D
G180 VSL SCS-R (JAPAN ONLY)
G181 VSL 3 SCS-R 3-4 JAPAN ONLY
G182 MDC
G183 MDH