Thyssenkrupp Elevator: Field Maintenance

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 51

ThyssenKrupp Elevator UAE

.JUTVCJTIJ Elevator
7'(- Field Maintenance

Elevator Filed Maintenance 1


Table of Contents

Mitsubishi VFGL
Mitsubishi VFEL

Elevator Filed Maintenance 2



Mitsubishi VFGL
Quick Maintenance guide


ThyssenKrupp Elevator UAE

Elevator Filed Maintenance 3


Toggle & Rotary Switch Position

Elevator Filed Maintenance 4


Rotary Switch 7SEG3
UP : Lit when UP Command given
DN : Lit when DOWN Command given
21 : Door Open Command available
22 : Door Close Command available
29 : Safety Circuit Monitoring, Lit when OK
5:SD Contactor Monitoring, Lit when SD ON
PP : Line Phase Monitoring, Lit when OK
Elevator Filed Maintenance 5
7 SEGMENT
CONTENT OF INDICATOR
7SEG3 7SEG2 7SEG1
7SEG3 7SEG2 7SEG1
CONTENT OF SET, MONO
FUNCTION AND ERROR
DISPLAY
Inspection/Maintenance Mode
1. Switch the “AUTO-HAND” Switch in
KCA-94X Boardto lower side “HAND”


2. LED “60” must be OFF and “MNT” LED
must be ON

3. Run the lift UP & DN trough the “UP-DN”
Switch On the right side panel above the
MCB

Checking the Safety Circuit
1. Drawing code “SF-0X” is for safety cct drawing

2. The code G012 or G0XX is the group code,
in which you can find where the connection is
located or going to

3. Safety circuit are 110 VDC

3. Check the safety point in the Terminal Block (TB)
according to the SF-XX Drawing or in the connector.
refer to connector list in the back of CP Door.


4. Check the check point as below :

“73” Car Safety Cct


“79” Source for car safety Cct
“77” PIT stop switch
“78” Governoor Safety Cct

Elevator Filed Maintenance 6


SUPPLY UNIT

There are 3 Transformer Unit


TR-01 is the Main Transformer for supplying most
of the voltage. Located in the botom side of CP

TR-A, TR-B , is the Transformer for Hall Main Supply,


The number of TR-A,B etc is depend on the number
of landing floors

TR-G , is the transformer for supplying Lighting,


Super Visory Cct, Hall Button Group Supply

There are 2 SMPS (Switch Mode PS)


MPS-1 , is the Switch Mode Power Supply unit
located in the CP for supplying the CP Board P1 & E1

KNOW HOW
TR-01 Must be adopted to the correct supply voltage
Fiber optic connector in P1 is for group operation
Number after the PCB name inside the box is for Option :
Eg : KCD- 91 1A X , 1A is an Option Available

No Program to be downloaded for Mitsubishi
PS is Drawing for Power Suply
SF is drawing For Safety Circuit
BK is drawing for Brake & Safety related to Brake Cct
OR is drawing for Car signals
MC is drawing for Main Controler

Elevator Filed Maintenance 7


ROTARY SWITCH FUNCTION
SET1 SET0 MON1 MON0
0 6 0 8 Under Installation (this is for manual
operation for Installaion
(Will display floor height data)

0 8 0 8 Normal Operation (Floor Display)

0 0 0 8 Normal Operation (Floor Display)

1 SHIFT 0 8 As a SHIFT function

2 DNSH 0 8 As a DNSH function

3 WGHG 0 8 As a WGHG Function

4 WGHO 0 8 As a WGHO Function

0 2 0 8 (Write) No Load (NL)Setting for


installation

0 3 0 8 (Write) Balance Load (BL) Setting
for installation

0 4 0 8 Manual Operation with Speed


4mpm

0 5 0 8 (Write) No load weight data store


for maintenance( Orig BL - Orig
NL)+ Current Load

0 7 0 8 SPA (Write the floor height data),


start recording Floor data during
PDSET

0 9 0 8 CHK Mode

0 A 0 8 Door Disable (intelligent door


invalid)

0 B 0 8 Adjust Brake Torque ( Set brake
torque value using decimal)

Elevator Filed Maintenance 8
ROTARY SWITCH FUNCTION
SET1 SET0 MON1 MON0
0 C 0 8 Check Overload Buzzer, display will
show load ratio (%), to test the Buzzer
operate SW1

0 D 0 8 Matching the magnetic pole

0 E 0 8 TSD Allowance (margin) testing

0 F 0 8 TSD Running testing

0 0 0 0 Error Code Display

0 0 0 1 Car Position Indicator



0 0 0 8 Normal Operation

0 0 0 B Brake Checking

0 0 0 D Display Current Load, actuate SW1


will display NL data, actuate SW1
will display BL data

0 0 0 Other Indicate No of Floors

0 0 F 0 Drive Software Version


0 0 F 1 Control -1 Software Version




0 0 F 2 Suoervisory 1 Software Version

0 0 F 3 Suoervisory 2 Software Version




0 0 F 4 Control -2 Software Version

Elevator Filed Maintenance 9


ROTARY SWITCH FUNCTION
SET1 SET0 MON1 MON0

0 0 F 5 Parameter (CC) Software Version

0 0 F 6 Maintenance Software Version

0 0 F 7 Group Control -1 Software Version

0 0 F 8 Group Control -2 Software Version

0 0 F 9 Parameter (GC) Software Version

Notes :

Elevator Filed Maintenance 10


3)TOGGLE SWITCH SETTING

ROTARY SWITCH TOGGLE FUNCTION


SET1 SET0 MON1 MON0 SWITCH
All but 0,8 All but 0,8 0 0 SW1 CONFIRM
SW1 CHANGE
All but 0,8 All but 0,8 0 0 SW2 TOP CALL
SW2 BOTTOM CALL
0 0 All but 8 ALL SW1 UPC (Up call1
floor)
SW1 DNC (Down call
1 floor)
0 0 8 All but F SW1 NO USE
SW1 CHANGE

0 0 All but 8.9 ALL SW2 TOP CALL


SW2 BOTTOM CALL

0 0 8 All but F SW2 NO USE


SW2 CHANGE

0 0 8 All but F SW2 NO USE


SW2 CHANGE

Elevator Filed Maintenance 11


STTP For adjusting the levelling speed to final
stop,
For levelling accuracy, also adjust shift for
fine levelling

DLB For brake time adjustment during start.


O<--- opening late;Early opening--->F

LTB For brake time adjustment after final stop


O<--- Closing Late;Early closing--->F

TSD Terminal stop device

WGHO= For overload adjustment setting.


Rotate until overload device(29W)activated

WGHG= For load weighing device tuning, for rolled


back adjustment.

SHIFT= For riding comfort adjustment, to adjust the


+/- creeping time so the lift can reach the
level floor( default=8)

O<---under creeping; over creeping--->F


DNSH= For adjustment of down levelling,
if floor level cannot reach during Down Run
DNSH neeeds to be adjusted
(default=8),
O<---above level, below level--- >F

Elevator Filed Maintenance 12


LED MEANING

UP= Upward direction, Lit when up command is given

Dn= Downward direction, Lit when down command is given.

PP= Phase sensor, Lit when the lind in phase/ voltage is


normal.

21= Door open comand available.

22= Door close command available.

29= Safety circuit monitoring, lit if safety circuit is ok.

5= SD Contactor Monitoring

CWDT= CPU watch dog C(Car)

MWDT CPU watch dog M(Controller)

SWDT CPU watch dog S( Hall)

41DG Door Circuit

DZ Door Zone

60 Automatic Operation

Elevator Filed Maintenance 13


Elevator Filed Maintenance 14
Checking Error Code
1. Go to RS Mode for Error Checking
2. 7SEG3 will shows E, 7SEG2 Will shows the Error code as per description below
3. Wait for 2 seconds interval for next error to be shown
Code (7SEG2) Error Definition
0 No other faults
1 SWTGBL (ABNORMAL LOW SPEED,TGBL)
2 SWTGBH (ABNORMAL LOW SPEED,TGBH)
3 SWTGBR(ABNORMAL REVERSE RUNNING DIRECTION,TGBR)
4 SWTAST(LOSE SPEED,AST ERROR)
5 SSOCOK(OVERCURRENT DETECTION OR IPM ERROR DETECTION,OCO)/
SSIOCFO(GPS3)
Elevator Filed Maintenance 15
Code (7SEG2) Error Definition
6 SOVLT( Over voltage,OVL)
7 SSLVLT(LOW VOLTAGE,LVL)
8 SYCFLB(LB# CONTACTOR ERROR)/SWCFLB(GPS3)
9 SYCF5(5# or SD CONTACTOR ERROR)/SWCF5(GPS3)
A SYCFBK(BRAKE WINDING ERROR,#BK ERROR)/SWCFBK(GPS3)
B CAR SERIAL COMMUNICATION ERRO/STSTSCE
C LANDING FLOOR SERIAL COMMUNICATION ERROR/STSTSHE
D STSYER(SYSTEM ERROR,JUMPER SETTING ERROR)
E SDDNRS(DR-CPU UNABLE RESTART TESTING)
F SWNRS2 (CC-CPU UNABLE RESTART TESTING)
SETTING UP TABLE FOR JUMPER PLUGS & ROTARY SWITCHES

1) JUMPER PLUGS
0 : LOCATION INSERTED THE PLUGS

P1

KCD-91X

JPCL

WITH CL-ROM O


JPS=S E1
KCH-945

JUMPER ROTARY JP1~JP6


S/W A B OC (SW1)
JPS
S120 0 7
S130 0 3
S140 0 7
S150 0 8

Elevator Filed Maintenance 16


Elevator Filed Maintenance 17
EXPLANATION OF TEST POINT ON KCJ-42X BOARD REMARKS
TEST POINT FUNCTION
ICU U PHASE CURRENT COMMAND SIGNAL TESTING
ICV V PHAS CURRENT COMMAND SIGNAL TESTING
IU U PHASE DIRECT CURRENT SENSOR (DC-CT)FEEDBACK SIGNAL TESTING
IV V PHASE DIRECT CURRENT SENSOR (DC-CT)FEEDBACK SIGNAL TESTING
TV PWM USED TRIANGULAR (LOAD WAVE)SIGNAL TESTING
PWU U PHASE VOLTAGE COMMAND( BIAS AMPLIFIER OUTPUT) SIGNAL TESTING
PWV V PHASE VOLTAGE COMMAND( BIAS AMPLIFIER OUTPUT) SIGNAL TESTING
Elevator Filed Maintenance 18
TEST POINT FUNCTION REMARKS
PWW W PHASE VOLTAGE COMMAND( BIAS AMPLIFIER OUTPUT) SIGNAL TESTING
0V GROUND
A 5V TEST(+5V)POWER DETECTION CIRCUIT
TES *1
B
TING
OCC TEST OVER CIRCUIT DETECTION CIRCUIT *2
*1 Short-circuit 5V test point A and 0V on KCJ-420 and switch on Inspection mode.
1 Make sure that CWDT and DWDT lamp on KCJ-40X is not lit.
2 Changed to automatic mode, and confirm LED *89 is not lit.
3 Short Circuit 5V test point B and 0V make sure that it is same with above mentioned (1)
*2 Short-circuit test point OCC and 0V on KCJ-420 and set the car to automatic running mode
Make sure LED *89 on KCJ-40X is OFF and the car is stop immediately.
4) FLASH MEMORY
SYMBOL REMARKS VALUE

DLB - 8

STPP - 8

LTB - 8

NLWT -

BLWT -

SHIFT - 8

DNSH - 8

WGHG - 8

WGHO - 8



[NOTES]
1 DO NOT SET THE TOGGLE SWITCH "R/M-FWR"TO
THE FWR SIDE.
2 ADJUST ROTARY SWITCH "SET 1/0 & 0/8", "MON 1/0 & 0/8"
AND TOGGLE SWITCH "R/M-FWR" TO THE R/M SIDE WHEN
ELEVATOR IS HANDED OVER.

Elevator Filed Maintenance 19


Elevator Filed Maintenance 20
EXPLANATION OF 7-SEGMENT LED DISPLAY ON CARTOP BOARD
DISPLAY ERROR CODE EXPLANATION DISPLAY RROR CODE EXPLANATION
0 DOER CPU3 SERIAL COMMUNICATION
ERROR ( CPU3 RESET) 0
1 DOCH INVERTER OVERCURRENT 1
2 DGLV +12v UNDER VOLTAGE 2
3 DPLV MAIN CIRCUIT UNDER VOLTAGE 3
4 DCWD CPU1 ANALOG WDT ERROR 4 GS ERROR
5 DDWD CPU2 ANALOG WDT ERROR 5 POSITION
MONITORING DEVICE
ERROR(OLT/CLT IS ON
SIMULTANEOUSLY)
6 DDWD CPU2 DIGITAL WDT ERROR 6
Elevator Filed Maintenance 21
DISPLAY ERROR CODE EXPLANATION DISPLAY RROR CODE EXPLANATION
7 DGBR DOOR OPERATION LOGIC ERROR 7
8 DGBR DOOR CLOSE OPERATION ERROR 8
9 DCWD CPU1 DIGITAL WDT ERROR 9
A DGBH MAXIMUM SPEED TESTING A POSITION AREA
COUNT CHECKING
B DPSW POSITION MONITORING DEVICE
ERROR(INAPPROPRIATE OLT/CLT
POSITION SIMULTANEOUSLY) B
C DPLG ENCODER ERROR C
D DOCR OVERLOAD ERROR( MOTOR NORMAL POWER
OVERCURRENT) D DISPLAY WHEN
POWER IS CUT
E ------ SAFETY FACTOR OF DLD IS TOO
SMALL E
F DGBH OVERSPEED DETECTION NORMAL
RUNNING F
Elevator Filed Maintenance 22
EXPLANATION OF LED INDICATION ON CARTOP BOARD (DOR-1XX, DOR -2XX)
LED NAME EXPLANATION REMARKS
DCV USED FOR RECTIFIER VOLTAGE TESTING. WHEN THE POWER IS
DISCONNECTED, THE VOLTAGE FOR ELECTROLYTIC CAPACITOR
WILL REMAIN FOR 4-6SECONDS. WHEN THE VOLTAGE IS DEREASED
TO 17-30v,DCV(LED) IS OFF. WHEN DCV IS DISCONNECTED
ABNORMALLY, USING MULTIMETER TO TEST RECTIFIER VOLTAGE TO
PREVENT DAMAGE OF ANY CIRCUIT OR ELECTRONIC COMPONENT.
OLT/CLT LED IS LIT WHEN OLT/CLT IS VALID( LED IS LIT WHEN POSITION
SWITCH IS ACTIVATED)
GCUT IMPROPER CIRCUIT TESTING OPERATION CAUSES BOARD DRIVE
CIRCUIT DISCONNECTED. WHEN 7-SEGMENT LED DISPLAYING
“0-F””O-E”, GCUT LED: ON
H5V WHEN THE VOLTAGE OUTPUT IS AT 5V, LED IS LIT.
Elevator Filed Maintenance 23
EXPLANATION OF LED INDICATION ON CARTOP BOARD (DOR-1XX, DOR -2XX) (Contd..)
LED NAME EXPLANATION REMARKS
GOFF LED IS LIT WHEN DOOR CIRCUIT IS DISCONNECTED.

21 LED IS LIT WHEN DOOR OPEN SIGNAL IS AVAILABLE.

22 LED IS LIT WHEN DOOR CLOSE SIGNAL IS AVAILABLE.
DOQ WHEN SAFETY EDGE IS ACTUATED ( EXCEPT DLD)OR PRESSING
COP DOOR OPEN BUTTON TO CAUSE THE CAR DOOR REOPEN,
THE LED WILL LIGHT FOR MORE THAN 50 SECONDS
WDT LED IS OFF WHEN WDT IS ACTIVATED

LD0/LD MON FUNCTION

Elevator Filed Maintenance 24


LOAD INDICATION

SW

D
I SW
LOAD WEIGHING

LDI LDO CENTER POSITION


ADJUSTMENT

REMARKS SWITCH FUNCTION AND LED

INDICATES 50% LOAD INDICATES NO LOAD INDICATES CURRENT


7-SEGMENT DISPLAY
WEIGHT SAVED INTO WEIGHT SAVED INTO LOAD’S WEIGHT
E2PROM E2PROM



LD0/LD MON FUNCTION

Elevator Filed Maintenance 25


LOAD INDICATION

SW

2
ADJUSTMENT(Contd…)

I SW
LOAD WEIGHING

LDI LDO CENTER POSITION


TAKE THE CURRENT TAKE THE CURRENT LOAD AS
REMARKS SWITCH FUNCTION AND LED

LOAD AS BL( NO LOAD) NL( NO LOAD) AND STORE


7-SEGMENT DISPLAY
AND STORE INTO INTO EEPROM
EEPROM ( LED IS ( LED IS BLINKING INDICATES CURRENT
BLINKING WHEN WHEN STORING AND WEIGHT
STORING AND STOPPED STOPPED WHEN
WHEN STORING IS STORING IS
COMPLETED) COMPLETED)



LD0/LD MON FUNCTION

Elevator Filed Maintenance 26


STORED WEIGHT(WHEN INSTALLATION)

SW

5
ADJUSTMENT(Contd…)


I SW
LOAD WEIGHING

LDI LDO CENTER POSITION



REMARKS SWITCH FUNCTION AND LED

INDICATES STORE THE CURRENT LOAD AS NL


7-SEGMENT DISPLAY
THE STORED ( NO LOAD). TAKE ORIGINAL BL LOAD-
BL LOAD ORIGINAL LOAD + CURRENT LOAD AS BL
IN TO WRITE IN.(LED IS BLINKING WHEN INDICATES THE
EEPROM STORING AND STOPPED CURRENT LOAD
WHEN STORING IS COMPLETED)


PDSET( STORE FLOOR HEIGHT DATA)

Run the Elevator with low speed and stop the elevator
at bottom floor levelling zone.Press DCB.SPA button,the display
on p1 board will blink. Now, run the elevator fom bottom floor
to top floor with low speed ( no stop at half way). After elevator
car stop at top floor, display on P1 board will stop blinking and
will display the top floor’s number. PDSET is completed( see the
following procedure)

1. Stop the car at the lowest floor, Check DZ Signal under


maintenance mode

2. Place switch DCB-SPA on KCD -91 in control panel to the


lower side “SPA”

3. Is 7-Segment LED display blinking?


If not check wheter the Final LS is cut or Level inductor
faulty

4. Run the Elevator manually from bottom floor to top floor


under manual mode, DO NOT STOP BEFORE REACHING
TOP FLOOR

5. Once the PD-SET is Finish, the 7 Segment display will


show floor number.

Elevator Filed Maintenance 27


NOMENCLATURE
Group No. Code Application
G001 IPM INVERTER TYPE “IPM”
G002 IGBT INVERTER TYPE “IGBT”
G003 KRTX WITHOUT “T6” TERMINAL
G004 KRT WITH “T6” TERMINAL
G005 CHR1 CHANGE RESISTANCE TYPE 1
G006 CHR2 CHANGE RESISTANCE TYPE 2
G007 CHR3 CHANGE RESISTANCE TYPE 3

G009 LF1 LINE FILTER TYPE 1
G010 LF2 LINE FILTER TYPE 2
G011 LF3 LINE FILTER TYPE 3
G012 GB FOR GB
G013 WDE FOR WDE
G014 HK FOR HK
G015 WLD EXPORT(EXCLUDE GB-WDE OR HK)
G016 JPN ONLY JAPAN
G017 JPNX EXCEPT JAPAN
G018 WDEX EXCEPT WDE
G019 IU FOR IU
G021 MCB JAPAN ONLY
G022 MCBX EXPORT STANDARD
G023 ATX WITHOUT “TR-P”
G024 AT WITH”TR-P”
G025 200-250V, 380-390V PRIMARY VOLTAGE
OF INVERTER PART

Elevator Filed Maintenance 28


NOMENCLATURE (CONTD..)
Group No. Code Application
G026 206-215V,391-410V PRIMARY VOLTAGE
OF INVERTER PART
G027 216-220V,411-420V PRIMARY VOLTAGE
OF INVERTER PART
G029 ACL1X WITHOUT “AC REACTOR”
G030 ACL1 WITH AC REACTOR
G031 G024 400V POWER VOLTAGE 400
G032 G024 400V 346,415,420,460V
G033 380,440,480V
G034 H1V3,5SQ JAPAN ONLY
G035 H1V5,5SQ POWER WIRE SIZE, JAPAN
ONLY
G036 H1VBSQ, POWER WIRE SIZE
G037 H1V14SQ
G038 F14SQ
G040 5.5SQ EARTH WIRE SIZE
G041 14SQ EARTH WIRE SIZE
G042 22SQ EARTH WIRE SIZE
G043 TR-A 300 VA
G044 500VA
G045 1KVA
G046 UMR CLOCKWISE MOTOR ROTATION WHEN
CAR UP
G047 UML COUNTER CLOCKWISE MOTOR ROTA
TION WHEN CAR UP
G048 RP2 WITH ROPING 2:1
G051 BR1 EH-3510 JAPAN ONLY
G052 BR2 NO G051 AND G058 DESIGNATION
G053 RLX WITHOUT RELEVEL

Elevator Filed Maintenance 29


NOMENCLATURE (CONTD..)
Group No. Code Application
G054 RLUD G055 RLU/RLD (FOR WDE OR HK)
(WITH RELEVEL OR HOUSING JOB)
G055 RL WITH RELEVEL
G056 MELDX WITHOUT MELD
G057 MELD WITH MELD
G058 BR3 TRACTION MACHINE TYPE EH-3520
G060 1C 1CAR
G061 HSKX WITHOUT POWER SUPPLY CHANGE
ABLE FOR HALL STATIONS
G062 1CX 1CAR
G063 HSK WITH POWER SUPPLY CHANGEABLE
FOR HALL STATIONS
G064 FEX EXPORT(STANDARD)
G065 FE (JAPAN ONLY)
G066 LIGK LIGHTING POWER BY LOCAL
G067 LIGY LIGHTING POWER BY LIGHTING TRANS
FORMER

Elevator Filed Maintenance 30


NOMENCLATURE (CONTD..)
Group No. Code Application
G068 2SQ JAPAN ONLY
G069 3. 5SQ JAPAN ONLY
G070 H2-X2 TAP SELECTION TABLE FOR
LIGHTING TRANSFORMER
G071 H3-X3 TAP SELECTION TABLE FOR
LIGHTING TRANSFORMER
G072 H3-X2 TAP SELECTION TABLE FOR
LIGHTING TRANSFORMER
G073 H4-X2 TAP SELECTION TABLE FOR
LIGHTING TRANSFORMER
G074 H4-X3 TAP SELECTION TABLE FOR
LIGHTING TRANSFORMER
G075 H5-X2 TAP SELECTION TABLE FOR
LIGHTING TRANSFORMER
G076 H5-X3 TAP SELECTION TABLE FOR
LIGHTING TRANSFORMER
G077 H2-X3 TAP SELECTION TABLE FOR
LIGHTING TRANSFORMER
G080 HET JAPAN ONLY
G081 Z1 WITH P.C.B KCA-70XX FOR OPTION 1/F
G082 CDBX WITHOUT PCB BASKET

Elevator Filed Maintenance 31


NOMENCLATURE (CONTD..)
Group No. Code Application
G083 CDB WITH PCB BASKET
G084 ACBX WITHOUT BREAKER PCB
G085 ACB WITH BREAKER PCB
G086 HSTA WITH ADDITIONAL POWER SUPPLY FOR
HALL STATION A
G087 HSTB WITH ADDITIONAL POWER SUPPLY A.B
FOR HALL STATION
G088 HSTD WITH ADDITIONAL POWER SUPPLY
A,B,C,D FOR HALL STATION
G089 HSCHX WITHOUT CHANGEABLE CIRCUIT FOR
SERIAL LINE
G090 HSCH WITH CHANGEABLE CIRCUIT FOR SE
RIAL LINE
G091 EER WITH EER-S OR EER-P
G092 EERPX WITH EER-S
G093 EERP WITH EER-S OR EER-P
G094 EESWX WITH EER-S WITHOUT EER KEY SWITCH

Elevator Filed Maintenance 32


NOMENCLATURE (CONTD..)
Group No. Code Application
G095 EESW WITH EER-S WITH EER KEY SWITCH
G096 VIB WITH EER-S
G097 AEA JAPAN ONLY
G098 EXPX WITH EER-S
G099 EXP JAPAN ONLY
G100 FER WITH FER
G101 OEP WITH OEPS
G102 EMRX G101 WITOUT EMEREGENCY POWER
A-TYPE SIGNAL
G103 EMR G101 WITH EMERGENCY POWER A-
TYPE SIGNAL
G104 OEPA WITH OEPS-A

Elevator Filed Maintenance 33


NOMENCLATURE (CONTD..)
Group No. Code Application
G105 ESTB WITH EMERGENCY STOP SWITCH IN
COP
G106 FESS FE SW 1SET/CAR
G107 FESB FE SW 1SET/BANK
G108 AVS AUDIO-VISUAL SIGNAL FOR FE
OPERATION
G110 TFSD JAPAN ONLY
G111 WP WITH WARNING PANEL
G112 LY48 WARNING PANEL LAMP VOLTAGE IS
DC48V
G113 NSS WITH MODE TYPE SERVICE CUT 1MODE
G114 NSS2 G113 WITH 2-4 MODE
G115 INTAB JAPAN ONLY
G116 EMAB MAL-FUNCTION SIGNAL OUTPUT
(SAFETY CIRCUIT TROUBLE)
G117 CONA MAL-FUNCTION SIGNAL OUTPUT
(SAFETY CIRCUIT TROUBLE)
G118 INTA JAPAN ONLY
G120 INTB JAPAN ONLY
G121 HBDC6 JAPAN ONLY
G122 HB100 JAPAN ONLY
G123 OCP JAPAN ONLY
G124 CPD JAPAN ONLY
G125 CPDK JAPAN ONLY

Elevator Filed Maintenance 34


NOMENCLATURE (CONTD..)
Group No. Code Application
G126 CPDK JAPAN ONLY
G128 LION JAPAN ONLY
G130 VSS JAPAN ONLY
G131 VS3 G130(SCS-R)
G133 ITV JAPAN ONLY
G135 GL JAPAN ONLY
G136 MWEL WITH MELD LAMP ON WARNING PANEL
G137 1D1G
G138 1D2G
G139 2D2G
G140 LSES
G142 HYD JAPAN ONLY
G143 400NX EXPORT TO HK WITHOUT M/R RUN-
STOP SW
G144 400N EXPORT TO HK WITH M/R RUN-STOP
SW
G145 DB WITH DOUBLE BRAKE
G146 COL1X JAPAN ONLY
G147 COL1 JAPAN ONLY
G148 C200 JAPAN ONLY
G149 C200X JAPAN ONLY
G151 AT1 G024 TR-P INSIDE CONTROL PANEL
G152 AT0 G024 TR-P OUTSIDE CONTROL PANEL
G153 ACL11 G030 ACL1 INSIDE CONTROL PANEL


Elevator Filed Maintenance 35
NOMENCLATURE (CONTD..)
Group No. Code Application
G154 ACL10 G024 ACL1 OUTSIDE CONTROL PANEL
G157 RADX WITHOUT RADIATOR
G158 RADX WITTH RADIATOR(HYD. ELEVATOR ONLY)
G159 RADA G158 (HYD ONLY)
G160 60HZ 50 HZ (HYD ONLY)
G161 50HZ 60HZ (HYD ONLY)
G162 HOFF WITH POWER SUPPLY ONLY FOR DESIG
NATED FLOOR DURING FE
G163 HOFFX WITH POWER SUPPLY FOR ALL FLOORS
DURING FE
G164 FESO G196 PHASE-1 < G196 WITH 2ND
PHASE-1 KEY SW>
G165 HKDX G014 NOT DISABLED LIFT FOR HK
G166 HKD DISABLED LIFT FOR HK
G167 SHBT IU ONLY
G170 EER3X G091 (JAPAN ONLY)
G171 EER3X G091 (JAPAN ONLY)
G172 MA G091 (JAPAN ONLY)
G174 FERAX G100 WITHOUT KEY SW.AUTO POS
G175 FERA G100 WITH KEY SW.AUTO POS
G178 EERD WITH EER-D
G180 VSL SCS-R (JAPAN ONLY)
G181 VSL 3 SCS-R 3-4 JAPAN ONLY
G182 MDC
G183 MDH

Elevator Filed Maintenance 36


NOMENCLATURE (CONTD..)
Group No. Code Application
G185 GC WITH GC PANEL
G186 GCX WITHOUT GC PANEL
G187 CHUX JAPAN ONLY
G188 CHDX JAPAN ONLY
G189 CHGX JAPAN ONLY
G190 EK1 JAPAN ONLY
G191 EKI2 JAPAN ONLY
G192 EKI3 JAPAN ONLY
G195 ANSIX ANSI-FE WITHOUT ANSI-FE OEPRATION
INCLUDED FOR IU
G196 ANSI ANSI-FE WITH ANSI-FE OEPRATION
INCLUDED FOR IU
G197 BSFE WITH FE OPERATION FOR ENGLAND
G198 GRFE WITH FE OPERATION FOR GERMANY
G350 HSX WITHOUT HALL STATION
G351 RC WITH RETIRING CAMPANEL
G352 HSN WITH HALL STATION
G353 HSN2 WITH C/P I/F SYSTEM (HALL STATION)
G356 MHB MAIN HALL BUTTON CONNECT CAR
G357 SHB SUB HALL BUTTON CONNECT CAR
G359 RC2 WITH RETIRING CAM I/F
G400 FC WITH KEY-CAR (FIRE MAN)

Elevator Filed Maintenance 37


NOMENCLATURE (CONTD..)
Group No. Code Application
G401 FCX EXCEPT KEY-CAR
G402 HB WITH HALL BUTTON
G405 2C 2
G406 3C 3
G407 4C 4
G415 HBF HALL BUTTON WITH .F
G416 HBG HAL BUTTON WITH .G
G417 HBH HALL BUTTON WITH .H
G418 HB1 HALL BUTTON WITH.I
G420 DFP1 DUBAI FERTYPE KEY SW
G421 DFP2 DUBAI FER TYPE KEY SW.+ FIRE
DETECTOR
G422 DFP3 DUBAI FER TYPE FIRE DETECTOR
G430 HKDG G014 WITH DISABLED LIFT IN BANK
FOR HK
G435 DBG WITH CONNECTOR DBG
G440 ALBA WITH INPUT FOR MAL-FUNCTION
SIGNAL FROM OTHER BANK
G441 BSO WITH BSO
G442 TFS WITH TFS
G443 TEMP WITH TEMP
G444 MCRT WITH MELMOS

Elevator Filed Maintenance 38


NOMENCLATURE (CONTD..)
Group No. Code Application
G445 MFER FER CONTROL BE MELMOS
G446 MFERX FER CONTROL BY KEY SW(NON USE
MELMOS)
G447 YOB1 GR01(1-2), JAPAN ONLY
G448 Y0B3 GR01(3-4), JAPAN ONLY
G450 P1WL WITH POSITION IND AT PARA
WP(LAMP NO LATCH TYPE)
G451 9<=STOPS<=16
G452 17<=STOPS<=24
G453 25<=STOPS<=32
G454 PIWD WITH POSITION IND AT PARA
WP(DIGITAL NO LATCH TYPE)
G455 PIWLL WITH POSITINO IND AT PARA
WP(LAMP LATCH TYPE)
G456 PIWDL WITH POSITION IND AT PARA
WP(DIGITAL LATCH TYPE)
G460 BOEPX G101 WITHOUT JOIN OTHER BANK
DEPS
G461 BDEP G101 WITH JOIN OTHER BANK DEPS
G462 FRB G461 1ST RETURN BANK
G463 FRBX G461 EXCEPT G462
G464 KB KEY-BANK(SUPPLIED BY COMMON
POWER SOURCE)

Elevator Filed Maintenance 39


NOMENCLATURE (CONTD..)
Group No. Code Application
G465 KBX EXCEPT KEY BANK
G470 NSQ WITH EACH FLOOR TYPE SERVICE
CUT
G471 9<=STOPS<=16
G472 17<=STOPS<=24
G473 25<=STOPS<=32
G480 GDRR WITH PCB GDR-R
G481 GDRD WITH PCB GDR-D
G490 G083 POWER VOLTAGE
200,230,346,380,460V
G491 G083 POWER VOLTAGE
210,240,400,460V
G492 G083 POWER VOLTAGE 210,250,420V
G493 G083 POWER VOLTAGE 400V
GS01
GS02
GS03

Elevator Filed Maintenance 40


Explanation on electric symbols
of GPS-3 passenger Elevator
CODE NAME LOCATION
IDSD DOWN TRAVEL TERMINAL LOWER PART OF
LANDING SLOW-DOWN HOISTWAY
SWITCH
IDSDA DOWN TRAVEL TERMAINAL LOWER PART OF
LANDING SLOW HOISTWAY
IUSD UP TRAVEL TERMINAL UP PART OF
LANDING SLOW HOISTWAY
IUSDA UP TRAVEL TERMINAL UP PART OF
LANDING SLOW HOISTWAY
5/SD MAINT CIRCUIT CONTACT CONTROL PANEL
ACB BREAKER OF GROUP CONTROL PANEL
CONTROL
ACL2 AC REACTOR CONTROL PANEL
ALARM ALARM AND INTERPHONE IN-CAR OPERA
BUTTON TION PANEL
AUTO/HAND AUTO/HAND SETING CAR TOP, IN-CAR,
SWITCH MACHINE ROOM

Elevator Filed Maintenance 41


Explanation on electric symbols
of GPS-3 passenger Elevator contd..
CODE NAME LOCATION
BK BRA CONTROL COIL TRACTION MA
CHINE
BRA BRAKE,CHARGE CONTROL PANEL
RESISTANCE UNIT
CAB EARTH EARTH PLATE CAR TOP,MACHINE
ROOM
COMMON CONFIRMATION BUTTON CAR TIO
FOR HAND OPERATION
CH CONTROL CONTACT OF CONTROL PANEL
CHARGING CIRCUIT
CHG CHARGING CIRCUIT CONTROL PANEL
BREAKER
CTU CTV CURRENT SENSOR CONTROL PANEL
CWT-GOV CONTER WEIGHT
GOVERNOR SWITCH GOVERNOR
DL DOWN TRAVEL LOWER PART OF
LIMIT SWITCH HOISTWAY

Elevator Filed Maintenance 42


Explanation on electric symbols
of GPS-3 passenger Elevator contd..
CODE NAME LOCATION
DOOR CUT CUT OFF DOOR CAR TOP, IN- CAR
MACHINE OPERATION
SWITCH
DOT DOWN TRAVEL TERMINAL LOWER PART OF
STOP SWITCH HOISTWAY
DOWN DOWN TRAVEL BUTTON CARTOP,MACHINE
IN HAND MODE ROOM
DS LANDING DOOR LOCK LANDING DOOR
SWITCH
DSR DOWN TRAVEL LOWER PART OF
TERMAINAL SLOW - HOISTWAY
DOWN SWITCH
DZU DZD LEVELING SWITCH CAR TOP
E.EXIT CAR SAFETY WINDOW CAR TOP
FAN SW IN-CAR FAN SWITCH IN-CAR OPERA
TIONAL PANEL
FC-M FERRITE CORE CONTROL PANEL
FE SW FIRE RETURN LANDING
OPERATION SWITCH

Elevator Filed Maintenance 43


Explanation on electric symbols
of GPS-3 passenger Elevator contd..
CODE NAME LOCATION
PIT STOP SW STOP SWITCH PIT
POWER DOOR MOTOR POWER CAR TOP
(ON CAR) SWITCH
RUN/STOP OPERATION / STOP CAR TOP
SWITCH
RWP HAND WHEEL MACHINE ROOM
INSPECTION SWITCH
RZU RZD RE-LEVEL SWITCH CAR TOP
SAF SAFETY GEAR SWITCH CAR PLATFORM
SECRET PASSWORD CALL IN-CAR OPERA
CALL OPERATION SWITCH TION PANEL
TR-01 MAIN CONTROL CONTROL PANEL
TRANSFORMER
TR-A ADDITIONAL CONTROL PANEL
TRANSFORMER
TR-G GROUP CONTROL CONTROL PANEL
ADDITIONAL
TRANSFORWER

Elevator Filed Maintenance 44


Explanation on electric symbols
of GPS-3 passenger Elevator
CODE NAME LOCATION
UL UP TRAVEL LIMIT STOP UP PART OF
SWITCH HOISTWAY
UOT UP TRAVEL TERMINAL UP PART OF
POSITION SWITCH HOISTWAY
UP INSPECTION UP CAR TOP, IN-CAR,
TRAVEL BUTTON MACHINE ROOM
USR UP TRAVEL TERMINAL UP PART OF
LANDING SLOW-DOWN HOISTWAY
SWITCH
FER SW FIRE RETURN OPERATION
SWITCH LANDING
GOC CAR GOVERNOR SWITCH GOVERNOR
GS CAR DOOR LOCK SWITCH CAR DOOR
INTERPHONE IN-CAR INTERPHONE IN-CAR OPERATION
DEVICE PANEL
IS INVERTER CONTROL PANEL
KRA REGENERATION UNITS CONTROL PANEL
LB BRAKE CONTROL CONTROL PANEL
CONTACT
LF WAVE FILTER CONTROL PANEL
LIGHT B IN-CAR LIGHT SWITCH IN-CAR OPERA
TION PANEL

Elevator Filed Maintenance 45


Explanation on electric symbols
of GPS-3 passenger Elevator
CODE NAME LOCATION
M TRACTION MOTOR TRACTION
MACHINE
MPS-1 STABILIZED VOLTAGE
SUPPLY CONTROL PANEL
NON SERVICE SERVICE LANDING IN-CAR OPERA
SWITCHOVER TION PANEL
NORMAL/INS NORMAL/INSPECTION CAR TOP
SWITCH
NORMAL/IND NORMAL/INDEPENDENT IN-CAR OPERA
SWITCH TION PANEL
NORMAL/W.A NORMAL/WITH IN-CAR
ATTENDANT SETTING OPERATION
SWITCH PANEL

Elevator Filed Maintenance 46


Elevator Filed Maintenance 47
Elevator Filed Maintenance 48
Elevator Filed Maintenance 49
Elevator Filed Maintenance 50
Elevator Filed Maintenance 51