Comment: Diagrama de Control

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

DIAGRAMA DE CONTROL

Comment

Prepared By

Date
PLC Parameter 9/24/2020
Data Name : Memory Capacity
Memory Capacity
[Memory Capacity]
8000

[Program Capacity]
8000 Steps

[Comments Capacity]
0 Block 0 Points

[File Register Capacity


0 Block 0 Points

1
PLC Parameter 9/24/2020
Data Name : PLC System
PLC System
[Battery Less Mode]
OFF

[MODEM Initialized]
None

[RUN Terminal Input]


None

2
PLC Parameter 9/24/2020
Data Name : Device
Device
[Device]
Latch Latch Setting
Sym. Dig. Points Start End End
Start Range
Supplemental Relay M 10 3072 0 3071 500 1023 0 - 1023
State S 10 1000 0 999 500 999 0 - 999
Timer T 10 256 0 255
Counter(16bit) C 10 200 0 199 100 199 0 - 199
Counter(32bit) C 10 56 200 255 220 255 200 - 255
Data Register D 10 8000 0 7999 200 511 0 - 511

3
Program setting 9/24/2020
Data Name : Program setting

Execution type Program file name


[Title]
Execution Program MAIN

4
Ladder 9/24/2020
Data Name : MAIN

X000 M200
0 M200 B/D 14 19 43 61
B/D

X002 M101 M100


2 M100 A/S 28

AUTOMATI MANUAL A AUTOMATI B/D 6 10 35 53

CO UX CO AUX

X003 M100 M101


5 M101 A/S 29

MANUAL AUTOMATI MANUAL A B/D 3 13 38 56

CO AUX UX

M50 M101 M200 D1 T7


8 T7 A/S 27

MANUAL A TIMER VA B/D 20


UX LVULA 1

X050 M100 M200 T7 X052


Y030
SELECTOR AUTOMATI TIMER VA SELECTOR VALVULA
VALVULA CO AUX LVULA 1 CABINA 1 CAB A
1 B

X053
Y033
SELECTOR VALVULA
CABINA 1 CAB 2
A

T7 M100 M101 D2 T8
27 T8 A/S 51

TIMER VA AUTOMATI MANUAL A TIMER VA B/D 44


LVULA 1 CO AUX UX LVULA 2

M101 X052 X050 X051 M100 M200 T8 X052


Y031
MANUAL A SELECTOR SELECTOR SELECTOR AUTOMATI TIMER VA SELECTOR VALVULA
UX CABINA VALVULA VALVULA CO AUX LVULA 2 CABINA 2 CABINA
B 1 3 B 1

X053 X053
Y034
SELECTOR SELECTOR VALVULA
CABINA CABINA 2 CABINA
A A 2

5
Ladder 9/24/2020
Data Name : MAIN

T8 M101 D3 T9
51 T9 B/D 62

TIMER VA MANUAL A TIMER VA B/D


LVULA 2 UX LVULA 3

X051 M100 M200 T9 X052


Y032
SELECTOR AUTOMATI TIMER VA SELECTOR VALVULA
VALVULA CO AUX LVULA 3 CABINA 3 CABINA
3 B 1

X053
Y035
SELECTOR VALVULA
CABINA 3 CABINA
A 2

69 END

6
Device Comment 9/24/2020
Data Name : COMMENT
Device Name Comment
M100 AUTOMATICO AUX
M101 MANUAL AUX
X002 AUTOMATICO
X003 MANUAL
X050 SELECTOR VALVULA1
X051 SELECTOR VALVULA 3
X052 SELECTOR CABINA B
X053 SELECTOR CABINA A
X054 SELECTOR CABINA A
Y030 VALVULA 1 CAB A
Y031 VALVULA 2 CABINA 1
Y032 VALVULA 3 CABINA 1
Y033 VALVULA 1 CAB 2
Y034 VALVULA 2 CABINA 2
Y035 VALVULA 3 CABINA 2
T7 TIMER VALVULA 1
T8 TIMER VALVULA 2
T9 TIMER VALVULA 3

7
TC Setting 9/24/2020
Data Name : MAIN
Position Device Setting Value
( 15) T7 D1
( 39) T8 D2
( 57) T9 D3

8
Device List 9/24/2020
Data Name : Device List

Find In:(Entire project)


Find What:Used Device (Contact & Coil)
Print Range:Whole Range

*:in use (times): the number of coil uses

Device Contact Coil Parameter Comment


M100 * (Times)
*( 1) AUTOMATICO AUX
M101 * *( 1) MANUAL AUX
M200 * *( 1)
T7 * *( 1) TIMER VALVULA 1
T8 * *( 1) TIMER VALVULA 2
T9 * *( 1) TIMER VALVULA 3

9
Project Contents List 9/24/2020
Data Name : Project Contents List
Workspace Name :
Project Name : REPROGRAMACION LIN4
Title :

Data Name Last Change Title


Parameter 23/09/2020 10:19:18 a. m.
PLC Parameter 23/09/2020 10:19:18 a. m.
Global Device Comment 23/09/2020 03:31:55 p. m.
Program Setting
Execution Program
MAIN 23/09/2020 10:19:20 a. m.
MAIN 23/09/2020 05:20:32 p. m.
POU
Program 23/09/2020 10:19:20 a. m.
MAIN 23/09/2020 05:20:32 p. m.
Local Device Comment
Device Memory 23/09/2020 10:19:20 a. m.
MAIN 23/09/2020 10:19:20 a. m.

10