MN REINFORCEMENT (Sq.

mm) FOR DIIFFERENT FLOORS


FILE : option-4 WIND SPEED- 44 m/s
M25 Fe500 (Main) Fe415 (Sec.) ZONE-II FOR EARTHQUAKE

S.No. NO. SIZE PLINTH GROUND 1FLOOR 2FLOOR CRITICAL PROV. REIN. % GROUP

1 101 230 X 380 806 1252 1047 681 1252 1256.64 4-16+4-12 1.44 C1 OK
16 116 230 X 380 1009 1662 1036 511 1662 2060.88 4-20+4-16 2.36 C3 OK
8 108 230 X 380 950 1719 1108 906 1719 2060.88 4-20+4-16 2.36 C2 OK
22 122 230 X 380 997 1765 1328 1188 1765 2060.88 4-20+4-16 2.36 C4 OK
5 105 230 X 380 1049 1767 1170 607 1767 2060.88 4-20+4-16 1.81 C2 OK
9 109 230 X 380 910 1801 1172 801 1801 2060.88 4-20+4-16 2.36 C2 OK
17 117 230 X 380 1293 1806 1164 625 1806 2060.88 4-20+4-16 2.36 C3 OK
20 120 230 X 380 1112 1852 1185 651 1852 2060.88 4-20+4-16 1.81 C3 OK
12 112 230 X 380 1250 1875 1163 495 1875 2060.88 4-20+4-16 2.36 C2 OK
21 121 230 X 380 1302 1881 1185 813 1881 2060.88 4-20+4-16 1.81 C4 OK
19 119 230 X 380 1206 1951 1298 809 1951 2060.88 4-20+4-16 2.36 C3 OK
10 110 230 X 380 1228 2304 1880 1592 2304 2513.27 4-20+4-20 2.88 C2 OK
18 118 230 X 380 1467 2355 1524 657 2355 2513.27 4-20+4-20 2.88 C3 OK
11 111 230 X 380 1363 2415 1398 705 2415 2513.27 4-20+4-20 2.88 C2 OK
7 107 230 X 450 790 1506 1143 1157 1506 1608.50 4-16+4-16 1.55 C2 OK
6 106 230 X 450 1294 2607 1866 1283 2607 3220.13 4-25+4-20 3.11 C2 OK
15 115 300 X 450 1251 1793 1520 1262 1793 2060.88 4-20+4-16 1.53 C3 OK
4 104 300 X 450 1166 1881 1791 1508 1881 2060.88 4-20+4-16 1.53 C2 OK
14 114 300 X 450 1318 1883 1458 1396 1883 2060.88 4-20+4-16 1.53 C3 OK
3 103 300 X 450 1222 1911 1813 1614 1911 2060.88 4-20+4-16 1.53 C2 OK
2 102 300 X 450 1197 1965 1804 1516 1965 2060.88 4-20+4-16 1.53 C2 OK
13 113 300 X 450 1647 2002 1333 1020 2002 2060.88 4-20+4-16 1.53 C2 OK