Inspected By:

Inspection Date: 1/2/2021 12:36:03 PM Location


Equipment Equipment Name:
Ambient Air Temp: 21.2°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09930.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 24.6°C
Image Range 21.2°C to 35.3°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:36:03 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.7°C
Hot 35.3°C
Cold 21.2°C
Inspection Date: 1/2/2021 12:36:22 PM Location
Equipment Equipment Name:
Ambient Air Temp: 21.5°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09931.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 26.1°C
Image Range 21.5°C to 37.2°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:36:22 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 25.0°C
Hot 37.2°C
Cold 21.5°C
Inspected By:
Inspection Date: 1/2/2021 12:37:49 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.1°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09932.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 26.4°C
Image Range 25.1°C to 28.9°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:37:49 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 26.0°C
Hot 28.9°C
Cold 25.1°C
Inspected By:
Inspection Date: 1/2/2021 12:38:17 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.1°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09933.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 27.7°C
Image Range 25.1°C to 36.7°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:38:17 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 27.4°C
Hot 36.7°C
Cold 25.1°C
Inspected By:
Inspection Date: 1/2/2021 12:40:13 PM Location
Equipment Equipment Name:
Ambient Air Temp: 24.0°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09934.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 26.1°C
Image Range 24.0°C to 32.2°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:40:13 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 25.9°C
Hot 32.2°C
Cold 24.0°C
Inspected By:
Inspection Date: 1/2/2021 12:40:33 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.3°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09935.IS2

Image Info
Transmission 1.00
Average Temperature 24.9°C
Image Range 23.3°C to 36.7°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:40:33 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 25.6°C
Hot 36.7°C
Cold 23.3°C
Inspected By:
Inspection Date: 1/2/2021 12:41:45 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.3°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09936.IS2

Image Info
Transmission 1.00
Average Temperature 25.0°C
Image Range 23.3°C to 27.9°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:41:45 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.9°C
Hot 27.9°C
Cold 23.3°C
Inspected By:
Inspection Date: 1/2/2021 12:45:45 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.5°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09937.IS2

Image Info
Transmission 1.00
Average Temperature 25.0°C
Image Range 23.5°C to 28.1°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:45:45 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.2°C
Hot 28.1°C
Cold 23.5°C
Inspected By:
Inspection Date: 1/2/2021 12:46:51 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.6°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09938.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 25.2°C
Image Range 23.6°C to 27.9°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:46:51 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.2°C
Hot 27.9°C
Cold 23.6°C
Inspected By:
Inspection Date: 1/2/2021 12:48:09 PM Location
Equipment Equipment Name:
Ambient Air Temp: 24.3°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09939.IS2

Image Info
Transmission 1.00
Average Temperature 26.1°C
Image Range 24.3°C to 29.0°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:48:09 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 27.2°C
Hot 29.0°C
Cold 24.3°C
Inspected By:
Inspection Date: 1/2/2021 12:48:52 PM Location
Equipment Equipment Name:
Ambient Air Temp: 22.6°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09940.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 23.9°C
Image Range 22.6°C to 25.4°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:48:52 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 23.9°C
Hot 25.4°C
Cold 22.6°C
Inspected By:
Inspection Date: 1/2/2021 12:49:54 PM Location
Equipment Equipment Name:
Ambient Air Temp: 24.0°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09941.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 25.3°C
Image Range 24.0°C to 27.1°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:49:54 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.6°C
Hot 27.1°C
Cold 24.0°C
Inspected By:
Inspection Date: 1/2/2021 12:50:52 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.6°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09942.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 25.3°C
Image Range 23.6°C to 28.2°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:50:52 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 25.3°C
Hot 28.2°C
Cold 23.6°C
Inspected By:
Inspection Date: 1/2/2021 12:59:27 PM Location
Equipment Equipment Name:
Ambient Air Temp: 21.8°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09943.IS2

Image Info
Transmission 1.00
Average Temperature 25.2°C
Image Range 21.8°C to 31.8°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 12:59:27 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 25.4°C
Hot 31.8°C
Cold 21.8°C
Inspected By:
Inspection Date: 1/2/2021 1:05:59 PM Location
Equipment Equipment Name:
Ambient Air Temp: 21.9°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09944.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 23.8°C
Image Range 21.9°C to 29.0°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:05:59 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 25.6°C
Hot 29.0°C
Cold 21.9°C
Inspected By:
Inspection Date: 1/2/2021 1:08:40 PM Location
Equipment Equipment Name:
Ambient Air Temp: 21.9°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09945.IS2

Image Info
Transmission 1.00
Average Temperature 23.9°C
Image Range 21.9°C to 30.0°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:08:40 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.8°C
Hot 30.0°C
Cold 21.9°C
Inspected By:
Inspection Date: 1/2/2021 1:12:32 PM Location
Equipment Equipment Name:
Ambient Air Temp: 22.8°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09946.IS2

Image Info
Transmission 1.00
Average Temperature 24.0°C
Image Range 22.8°C to 25.6°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:12:32 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 23.5°C
Hot 25.6°C
Cold 22.8°C
Inspected By:
Inspection Date: 1/2/2021 1:13:59 PM Location
Equipment Equipment Name:
Ambient Air Temp: 21.5°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09947.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 23.5°C
Image Range 21.5°C to 30.4°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:13:59 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 23.0°C
Hot 30.4°C
Cold 21.5°C
Inspected By:
Inspection Date: 1/2/2021 1:17:42 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.6°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09948.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 27.4°C
Image Range 25.6°C to 30.4°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:17:42 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 26.9°C
Hot 30.4°C
Cold 25.6°C
Inspected By:
Inspection Date: 1/2/2021 1:17:57 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.6°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09949.IS2

Image Info
Transmission 1.00
Average Temperature 27.2°C
Image Range 25.6°C to 30.3°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:17:57 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 27.5°C
Hot 30.3°C
Cold 25.6°C
Inspected By:
Inspection Date: 1/2/2021 1:21:43 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.9°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09950.IS2

Image Info
Transmission 1.00
Average Temperature 27.2°C
Image Range 25.9°C to 30.0°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:21:43 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 26.8°C
Hot 30.0°C
Cold 25.9°C
Inspected By:
Inspection Date: 1/2/2021 1:21:50 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.0°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09951.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 26.7°C
Image Range 25.0°C to 29.0°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:21:50 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 26.2°C
Hot 29.0°C
Cold 25.0°C
Inspected By:
Inspection Date: 1/2/2021 1:24:58 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.5°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09952.IS2

Image Info
Transmission 1.00
Average Temperature 27.1°C
Image Range 25.5°C to 30.7°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:24:58 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 26.9°C
Hot 30.7°C
Cold 25.5°C
Inspected By:
Inspection Date: 1/2/2021 1:25:11 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.1°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09953.IS2

Image Info
Transmission 1.00
Average Temperature 26.5°C
Image Range 25.1°C to 28.7°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:25:11 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 26.5°C
Hot 28.7°C
Cold 25.1°C
Inspected By:
Inspection Date: 1/2/2021 1:29:40 PM Location
Equipment Equipment Name:
Ambient Air Temp: 24.8°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09954.IS2

Image Info
Transmission 1.00
Average Temperature 26.5°C
Image Range 24.8°C to 29.6°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:29:40 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 25.4°C
Hot 29.6°C
Cold 24.8°C
Inspected By:
Inspection Date: 1/2/2021 1:29:53 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.7°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09955.IS2

Image Info
Transmission 1.00
Average Temperature 27.1°C
Image Range 25.7°C to 29.7°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:29:53 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 27.2°C
Hot 29.7°C
Cold 25.7°C
Inspected By:
Inspection Date: 1/2/2021 1:34:29 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.4°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09956.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 26.8°C
Image Range 25.4°C to 31.5°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:34:29 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 26.9°C
Hot 31.5°C
Cold 25.4°C
Inspected By:
Inspection Date: 1/2/2021 1:40:01 PM Location
Equipment Equipment Name:
Ambient Air Temp: 25.4°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09957.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 27.0°C
Image Range 25.4°C to 31.7°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:40:01 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 26.4°C
Hot 31.7°C
Cold 25.4°C
Inspected By:
Inspection Date: 1/2/2021 1:42:08 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.0°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09958.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 24.8°C
Image Range 23.0°C to 29.6°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:42:08 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 25.2°C
Hot 29.6°C
Cold 23.0°C
Inspected By:
Inspection Date: 1/2/2021 1:57:58 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.4°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09960.IS2

Image Info
Transmission 1.00
Average Temperature 25.4°C
Image Range 23.4°C to 31.7°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 1:57:58 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.5°C
Hot 31.7°C
Cold 23.4°C
Inspected By:
Inspection Date: 1/2/2021 2:00:34 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.8°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09961.IS2

Image Info
Transmission 1.00
Average Temperature 25.9°C
Image Range 23.8°C to 31.6°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:00:34 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.6°C
Hot 31.6°C
Cold 23.8°C
Inspected By:
Inspection Date: 1/2/2021 2:02:16 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.7°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09962.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 25.5°C
Image Range 23.7°C to 31.4°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:02:16 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.3°C
Hot 31.4°C
Cold 23.7°C
Inspected By:
Inspection Date: 1/2/2021 2:03:42 PM Location
Equipment Equipment Name:
Ambient Air Temp: 22.4°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09963.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 24.2°C
Image Range 22.4°C to 30.4°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:03:42 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 23.3°C
Hot 30.4°C
Cold 22.4°C
Inspected By:
Inspection Date: 1/2/2021 2:05:12 PM Location
Equipment Equipment Name:
Ambient Air Temp: 22.6°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09964.IS2

Image Info
Transmission 1.00
Average Temperature 24.7°C
Image Range 22.6°C to 31.8°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:05:12 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 23.2°C
Hot 31.8°C
Cold 22.6°C
Inspected By:
Inspection Date: 1/2/2021 2:08:11 PM Location
Equipment Equipment Name:
Ambient Air Temp: 22.9°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09965.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 24.8°C
Image Range 22.9°C to 36.7°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:08:11 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.9°C
Hot 36.7°C
Cold 22.9°C
Inspected By:
Inspection Date: 1/2/2021 2:18:30 PM Location
Equipment Equipment Name:
Ambient Air Temp: 24.0°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09966.IS2

Image Info
Transmission 1.00
Average Temperature 27.2°C
Image Range 24.0°C to 44.7°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:18:30 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 26.4°C
Hot 32.6°C
Cold 24.0°C
Inspected By:
Inspection Date: 1/2/2021 2:32:50 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.2°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09967.IS2

Image Info
Transmission 1.00
Average Temperature 25.0°C
Image Range 23.2°C to 30.4°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:32:50 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 25.3°C
Hot 30.4°C
Cold 23.2°C
Inspected By:
Inspection Date: 1/2/2021 2:41:47 PM Location
Equipment Equipment Name:
Ambient Air Temp: 24.4°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09968.IS2

Image Info
Transmission 1.00
Average Temperature 26.9°C
Image Range 24.4°C to 34.2°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:41:47 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 27.9°C
Hot 34.2°C
Cold 24.4°C
Inspected By:
Inspection Date: 1/2/2021 2:42:45 PM Location
Equipment Equipment Name:
Ambient Air Temp: 24.1°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09969.IS2

Image Info
Transmission 1.00
Average Temperature 26.7°C
Image Range 24.1°C to 34.1°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:42:45 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 27.1°C
Hot 34.1°C
Cold 24.1°C
Inspected By:
Inspection Date: 1/2/2021 2:52:45 PM Location
Equipment Equipment Name:
Ambient Air Temp: 22.9°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

IR_09970.IS2 Visible Light Image

Image Info
Transmission 1.00
Average Temperature 24.7°C
Image Range 22.9°C to 30.7°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:52:45 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.7°C
Hot 30.7°C
Cold 22.9°C
Inspected By:
Inspection Date: 1/2/2021 2:54:47 PM Location
Equipment Equipment Name:
Ambient Air Temp: 23.8°C Wind Speed
Load (%) Max Rated Load:
Exception Temperature: Potential Problem
Recommended Action Repair Priority:
Emissivity: 0.87 Reflected Temperature: 22.0 °C
Camera Manufacturer Fluke Thermography Camera: TiS10-16010562

Visible Light Image


IR_09971.IS2

Image Info
Transmission 1.00
Average Temperature 25.7°C
Image Range 23.8°C to 31.9°C
Camera Model TiS10
IR Sensor Size 80 x 60
Image Time 1/2/2021 2:54:47 PM
Calibration Range -20.0°C to 80.0°C

Main Image Markers


Name Temperature
Centerpoint 24.9°C
Hot 31.9°C
Cold 23.8°C