OMNI II

TOUCH SCREEN
PATIENT MONITOR

ECG, SPO2, NIBP,


HR, TEMP, RESP.

n 12.1” color TFT display with touch screen.


n Multi-lead ECG monitoring
n Touch screen user interface
n NIBP list & OxyCRG dynamic view display
n Drug dose calculations
n Large font display with 4, 6 & 8 waveforms shown
n Networkable with Central Monitoring System via
a wireless or wired network
n S-T Segment & 72 hours trend data analysis
n Compact design is convenient for mobile monitoring
n Multi-lingual settings
n Optional:
Advanced, Affordable Medical Technology For The World Dual IBP, EtCO2 and Built-in thermal recorder
OMNI II TECHNICAL SPECIFICATIONS

Physical Dimensions & Weight ECG (cont.) SPO2


Main Unit Sweep Speed: 12.5, 25 and 50 mm/s ASpO2: Anti-motion SpO2
Dimension: 555mm H x 335mm W x 235mm D HR Display Range: 15-300bpm SpO2% Range: 0-100%
Weight: 5kg Accuracy: ±1% or ±1bpm, whichever is greater SpO2 Accuracy: ±2% 70-100%, non-motion
S-7 Segment Detection: 7 channels ±3% 70-100%, motion
Application Measurement Range: -2.0mv - +2.0mv Pulse Rate Range: 30-250 bpm
Neonatal, pediatric and adult patients Arrhythmia Analysis: 13 types Pulse Rate Accuracy: ±2 bpm (non-motion)
Alarm Limit Range Setting ±3 bpm (motion)
Operation Environment Upper limit: 80-400bpm Alarm Upper-lower Limit Setting:
Power Lower limit: 20-150bpm upper limit 70-100%
Source: External AC power or internal battery lower limit 70-100%
AC Power: 100-240VAC, 50/60Hz, <150VA RESP SpO2 Probe
Battery: Rechargeable Lead-Acid Measure Method: RA-LL impedance Red light LED wavelength 660nm±5nm
Operating time under the normal Range: 0-120 rpm Infrared light LED wavelength 905nm±10nm
condition: 1 hour Accuracy ±3 rpm
Operating time after the first alarm of Alarm Upper-lower Limit Setting: IBP (OPTION)
low battery: 10 mines Upper limit: 6-120 rpm, Measurement Range: -50-300mmHg
Temperature Lower limit: 3-120 rpm Channel: 2 channels
Working: 5-40˚C Sweep Speed: 12.5 and 25 mm/s Pressure transducer: sensitivity, 5µV/V/mmHg
Storage: -20-65˚C Impedance range: 300-3000Ω
Relative Humidity NIBP Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Working: 30-75% Measuring Technology: Automatic oscillating measurement Resolution: 1mmHg
Storage: ≤80% Cuff Inflating: <30s (0-300mmHg, standard adult cuff) Accuracy: ±1mmHg or ±2%, whichever is greater
Altitude Measuring Period: AVE<40s Alarm range: -50-300mmHg
Operating Altitude: Up to 5,000 meters Mode: Manual, Auto, STAT
Hyperbaric Pressure: Up to 405.3 kPa Measuring Interval in AUTO Mode: EtCO2 (OPTION)
2 min-4 hrs Mode of Sampling: Sidestream
Peformance Specifications Pulse Rate Range: 30-250 (bpm) Principle of Operation: Non-dispersive infrared (NDIR) single
Display: 12.1” color TFT, Touch Screen Measuring Range: Adult/Pediatric Mode beam optics, dual wavelength, no
Resolution: 800 x 600 pixels SYS 40-250 (mmHg) moving parts.
Trace: 4, 6, 8 or 9 waveforms DIA 15-200 (mmHg) CO2 measurement Range:
ECG (I, II, III, aVR, aVL, aVF, V1-V6), Neonatal Mode 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
PLETH, RESP, IBPx2, ETCO2 SYS 40-135 (mmHg) CO2 Calculation Method:
Indicator: Alarm indicator DIA 15-100 (mmHg) BTPS (Body Temperature Pressure Saturated)
Power indicator Resolution: 1mmHg CO2 Resolution: 0.1mmHg(0-69mmHg),
QRS beep and alarm sound Accuracy: Pressure 0.25mmHg(70-150mmHg)
Trend time: 72 hours Maximum Mean error: ±5mmHg CO2 Accuracy: 0-40 mmHg ± 2 mmHg
Recorder: Built-in, thermal array, 2 channels Maximum Standard deviation: 8mmHg 41-70 mmHg ± 5% of reading
Record width: 48mm Overpressure Protection: 71-100 mmHg ± 8% of reading
Recorder paper: 50mm Adult Mode 280 (mmHg) 101-150 mmHg ± 10% of reading
Record speed: 25mm/s, 50mm/s Neonatal Mode 150 (mmHg) Above 80 breath per minute ± 12%
OxyCRG: Combines HR, SPO2 and Respiration Alarm Limit Setting of reading
trends into a single graph SYS 50-240 mmHg Sampling rate: 100Hz
DIA 15-180 mmHg Respiration Rate: 2-150 bpm
ECG Respiration Rate accuracy: ±1 breath
Input: 5-lead ECG cable and standard AAMI TEMP Response Time: <3 seconds - includes transport time
line for connection Range: 0-50˚C (32-122˚F) and rise time
Lead Choice: I, II, III, aVR, aVF, aVL, V Accuracy: Without sensor Inspired CO2 measurement Range:
Gain Choice: x0.125, x0.25, x0.5, x1.0, x2.0 Display Resolution: 0.1˚C 3-50 mmHg
Filter: Diagnostic mode: 0.05-100Hz Alarm Upper-lower Limit Setting:
Monitoring mode: 0.05-75Hz Upper limit 0-50˚C Specifications subject to change without notice.
Surgical mode: 1-20Hz Lower limit 0-50˚C
ECG Waveforms: 7 channels Channel: 2 channels, provide T1, T2, ∆T
Penetration Voltage: 4000VAC 50/60Hz

Selectable Screens:
4, 6 or 8 waveforms