Rectangular Isolated Footing Analysis
Footing description: the column at the center is loader with a column load and its moment is acting about the transverse o
Input Data:
Footing Data:
Determining the required additional load on the column so that the whole base of the footing will be under pressure
FORMULA:
Paddt'l= (q'max(A)(B))-700 Paddt'l= 1913.333 kN
NG ANALYSIS
t is acting about the transverse of the footing base.
Input Data:
Footing Data:
Footing Length, L 3m
Footing Width, B 2.5 m
Footing Thickness, T 0.7 m
Column load, P 1200 kN
Column Moment, M 360 KN-m
Base of the footing ,b 2.2 m
Unit Weight of Concrete 24 kn/m3
Unit Weight of Soil 18 kn/m3
Determining the minimum required gross allowable soil bearing capacity to carry the given loads
FORMULA:
q= qmin+ (ɣconc*T)-ɣsoil(b-T) q= 88.60 kPa