Professional Documents
Culture Documents
2009 PiCCO Advanced Hemodynamic Monitoring PDF
2009 PiCCO Advanced Hemodynamic Monitoring PDF
PiCCO-Technology ®
• Volumetric preload
• Afterload, contractility
• Volume responsiveness
PULSION History
PiCCO2®
2007
Dräger Infinity®
COLD System Philips PiCCO PiCCO SmartPod™
PiCCO® PiCCO plus® 2002 2005
1986-1997 Module 2003
1997
1-1
Background hemodynamics
Preload
Afterload Contractility
– GEDV
SVR CFI
– SVV
Pulmonary
edema
EVLW
Red Blood
Volume Vasopressors Inotropes
Cells
1-2
PiCCO2® - See more than others
• Continuous cardiac output
lungs
• Volumetric preload
Thermodilution-
Bolus via
standard CVC right and
left heart • Afterload
Monitoring via
body circulation PiCCO catheter • Contractility
• Volume responsiveness
1-3
Background hemodynamics
Arterial line
(PiCCO® Catheter
available in different
sizes)
Central venous line
(Standard CVC)
Axillary artery
Adults: 4F 8 cm, 3.15 in
Small adults: 3F 7 cm, 2.76 in
Brachial artery
Adults: 4F 16 cm, 6.29 in
Femoral artery
Adults: 5F 20 cm, 7.78 in
Adults: 4F 22 cm, 8.66 in
Small adults: 4F 16 cm, 6.29 in
Children: 3F 7 cm, 2.76 in
Children: 4F 8 cm, 3.15 in
1-4
Background hemodynamics
Physiology
Nutrition weeks
Water days
O2 minutes
Man can survive for weeks without nutrition, for days without water
but for only minutes without oxygen
1-6
Anatomy - the circulation
Lungs
Heart
Veins Intestines
1-7
Background hemodynamics
Hemo - blood
Oxygen transport
1-8
Physiology and pathophysiology
1-9
Background hemodynamics
• Severe sepsis
• Septic shock
• Respiratory failure
• Myocardial infarction
• Severe trauma
• Intracerebral bleeds
• Severe liver disease
• Burns
• Transplantation surgery
• Cardiac surgery
• Other high risk surgical procedures
Electrocardiogram (ECG)
Pulse oximetry
(SpO2)
Non invasive blood
pressure (NIBP)
These products are examples to illustrate and are not distributed by PULSION Inc.
1-10
Basic monitoring – invasive
Precise monitoring of certain variables requires often access to the circulatory system.
The Echo technology is a diagnostic tool for visualizing the heart`s morphology. The PA catheter (Swan
Ganz) monitors the pulmonary circulation and the PiCCO-Technology monitors the body circulation.
1-11
Background hemodynamics
Cardiac Output - CO
Amount of blood that is transported by the heart in one minute
Cardiac Output
• PiCCO2® works via a standard central venous catheter and a special arterial catheter
and its use is warranted in all cases where the patients volume status is unclear and / or
where accurate monitoring is required
1-13
Train the Trainer Folder US
See instructions for use and package insert for full prescribing information. Technical specifications are subject
to change without further notice. © 2009 PULSION Medical Systems all rights reserved.
© PULSION 08/2009
MPI851405US_R00
PULSION Medical Inc. • 2445 Gateway Drive • Suite 110 • TX 75063 Irving, USA
Tel. +1 (214) 446 8500 • Fax +1 (214) 446 6702 • Toll free +1 877 655 8844