Many information you must think about before you create IDB
How many digital units and radio units needed for that conf?
Regarding that our digital unit in 2G (DUG 20) can carry up to 12 carriers and
RRUS 01 B8 carries up to 4 carriers and RRUS 02 B8 carries up to 8 carriers and
these RRUSs are used for 900 MHz band.. the same utilization for RRUSs 01&02 B3
but it for 1800 MHz band.
So, it`s clear that if we have a required configuration 4+4+4 we need only one DU
but if we need 4+4+5 we`ll need 2 DUs.
Now we`ll describe how to install an IDB through the common program OMT.
As agreed from the above DU will carry only 12 carriers so we`ll need 2 DUs
RBS 6000 2G
serial RJ
5 1
3 2
2 3
Now we start our OMT prog and start to create our IDB
4. in the cabinet type box, select the cabinet type.
Standard if we have 3 fan groups.
14. after that you press OK and confirm all these done steps
15.
16.
A comparison between your HW and your IDB will be provided by the OMT and
through that comparison you will check that everything is OK . if there is anything
wrong OMT will give you info or warning about that.
20. you bring your RBS back to the remote mode (No maintenance mode)
21. please make sure that all RRUS in remote mode (no maintenance mode)
Now you almost finished but there are two important parameters that is highly
important mentioned
the RBS must have only one master DU and the rest DUs must be defined as slave
and this definition is done through defining the node .
And then you add external nodes with the same no# of slave DUs.
Please make sure that each node EC bus connected to its port in the SHU as
configured in the IDB
Master B1
Slave 0 A5
Slave 1 A6
Slave 2A7
If this cab will be groomed with another then you select its network topology as
cascade. And then define its TEI values to be 61.
Now let`s configure the RBS identity
These info will be founded printed on the cab itself.