PROCUREMENT, CONSTRUCTION AND COMMISSIONING OF AUTOMATIC BACKWASH WASH FILTER PACKAGES (1 NOS) ON 72 INCH

PROJECT TITLE:
SEA WATER SUPPLY LINES AT MAA REFINERY
CONTRACT NUMBER: CA/CPD/0265 DOCUMENT NUMBER: S0265.29-3.60-202-A-E REV: 6

SPECIFICATION FOR BUTTERFLY VALVE


PIPING
TAG NUMBER: VBU14401 SIZE RANGE: 4" - 12" IW3X
CLASS:
150# (260 PSIG SHUT FF TO ASME B16.5 (SURFACE FINISH:
RATING: STANDARD: API 609 ENDS:
OFF PRESSURE) 125-250 in)
SERVICE: SEA WATER

VALVE SPECIFICATION MANUFACTURER'S PROPOSAL


S.NO. DESCRIPTION
CONSTRUCTION MATERIAL CONSTRUCTION MATERIAL
ALM. BRONZE TO B148 UNS
1 BODY / TYPE CASTING
C95500
CATEGORY-B, BI-DIRECTIONAL, DOUBLE FLANGED,
2 CATEGORY
TRIPLE OFFSET
3 STEM ANTI BLOW OUT

4 DISC TRIM - ALUMINIUM


5 BODY SEAT BRONZE

6 RETAINING RING

7 BUSHING SUITABLE FOR SEA WATER


GRAPHITE WITH
SACRIFICIAL CORR. INHIB. &
8 STEM PACKING RENEWABLE
INCONEL WIRE
REINFORCEMENT
9 BOLTS ASTM A193 GR B7

10 NUTS ASTM A194 GR 2H

AS PER CLAUSE 6 OF KNPC STD. 50P2, PURCHASE


11 TESTING AND INSPECTION
REQUIREMENTS (TECHNICAL) VALVES

12 SPECIAL SERVICE CONDITION MAX. TEMP. 167°F MIN. TEMP. 14°F

13 FACE TO FACE DIMENSIONS API 609

14 TYPE OF BORE FULL BORE

15 TESTING STANDARD API 598 & KNPC ENGG STD 50P2

16 HYD. TEST PRESSURE (BODY) 400 PSIG

17 HYD. TEST PRESSURE (SEAT) BOTH SIDE 286 PSIG

18 TEST PRESSURE WITH AIR 60-100 PSIG

19 REQUIREMENT OF GEAR OPERATOR REQUIRED ABOVE 6"

20 PAINTING NOT APPLICABLE (AS PER KNPC STANDARD 83A1)

21 NACE REQUIREMENTS NOT REQUIRED


NOTES:
1) ALL VALVES SHALL MEET THE REQUIREMENTS OF KNPC ENG. STD. 50P2 - STANDARD FOR PURCHASING REQUIREMENTS (TECHNICAL) VALVES.
2) DOCUMENTATION SHALL INCLUDE MATERIAL TEST CERTIFICATES, PRESSURE TEST REPORTS, NDE ETC, MENTIONED IN THE COMPANY STANDARDS.
MANUFACTURING RECORD BOOK SHALL BE SUBMITTED.
3) PMI TEST OF VALVE AND INTERNALS FOR ALL NON CS PARTS SHALL BE AS PER EXHIBIT A, ANNEXURE A-16, QA/QC REQUIREMENTS FOR PROJECTS.
4) SEAT LEAKAGE TEST SHALL BE PERFORMED FOR BOTH DIRECTION AS PER API 598.