SIMPLICITY, PRODUCTIVITY, QUALITY RESULTS © a single, heated, level sensing aim minimizes I mechanical complexity y Py ‘and rapicly moves to all | 4 positions for: s optimized sample : = and reagen! mixing : : i =) 0 up io 3 different reagents Zi = addition 1o ecch method # sample ore-ilution ‘e sample rerun with or without dilution ‘e probe double washing between each sampling cycle sinner ond outer probe washing after every cycle y © a PRACTICAL DESIGN ON BOARD REAGENTS 2 up jo 64 reagents on 4 separate racks dditionol 8 positions n board storage at 8°C +12 °C # barcode tracking of reagents (optional) SAT 450 is 6 fully autemotic, random access onalyzer designed to suppert the modem laberctory in achieving improved cost efficiency, reduced rerun and manual handling, I provides quality results while following rigid quality, system procedures and in strict compliance wih regulatory agency requirements a |.S.E. MODULE (OPTIONAL) edirect measurement of Sodium, Potessium, Chloride and Lithium scasy access for reagent replacement ‘s mointenance ree electrodes Ci COST EFFICIENCY © 80 long Ife, 6 mm optical path, semiisposcble cuvetes 55 ae (4 separate racks with 20 cuveties each) « selective cuvette wash with 3 different liquids: ecid, clkaline and neviral E< T— * low water consumption: 1.5 I/h {© 200 p minimum reaction volume ‘e cuvote quoily automate chack FLEXIBILITY d technology and slicated system cering allow easy s for maintenance oses by simply j up the entire ight endlyical chesis ¢4 universal racks for cups ond primary tubes ‘= continuous looding of up to 15 samples an each rack (serum, plosma, urine} ‘urgent somple loading alowed ct any time stondords ond conirels can be placed on the some rocks with no limitations e positive identification of samples loptionel) ‘reagent dilution on board LIST OF APPLICATIONS The SAT 450 has all parameters set based on cur reagent kits given below: CLINICAL CHEMISTRY. a oe a Pin ue IMMUNOTURBIDIMETRY im ACID PHOSPHATASE Kinoic Colorimetric Talet 1 ACID GLYCOPROTEIN ALBUMIN BCG BCG Colorimetric Liquid cal ANTITRYPSINE AIDOLASE: Kinetic UW yo o2 MACROGLOBULIN ALK PHOSPATASE __Monochy. Light DGKC Ponders iid © ANTITROMBIN Ili ALK. PHOSPATASE DGKC. Liquid APO AL AMYLASE ‘CNP.GS Liquid APOB AMMONIUM Enzymatic UV yo ‘ASO. - QUANTITATIVE BIL DIRECT Jencrossik Grof Liguid a BIL TOTAL Jencrossik Grof Liguid a CALCIUM OCre Liquid CCERULOPLASMIN CALCIUM ARS I “aesen079 il Liauid CHAINS CHLORIDE Mercurie Thiscyanate Liquid CHAINS & CK = NAC SL uv —_Lguid CRP. QUANTITATIVE CK MB Kinet i FIBRINOGEN = CHOLESTEROL SL CHOD-PAP Liquid’ HAPTOGLOBIN HDL CHOL Divect Liquid oA z LDL CHOL Duect Liquid 1g CHOLINESTERASE SL__ Buryrythiocholine Liguid lo CREATININE life medified Liquid MICROALBUMIN DIBUCAINE NUMBER _Kineic Liguid RHEUMATOID FACTOR - QUANTITATIVE GAMMA GT SL Szasziis Liquid TRANSFERRIN GLUCOSE St GODFOD Liguid Gorsi eile UV = IFES Liquid Con Kinetic UV = IFEG Liquid HAEMOGLOBIN «;.peng * Tuibidimetic Liquid IRON F Forere © Power +i LOH SL Kinetic UV. DGKE Liquid LIPASE Colorimetic Liquid MAGNESIUM Blue Xi guid MICROPROTEIN B Colerimotie guid PHOSPHORUS ww guid x (ASSIUM Enzymatic lye : SODIUM Enzymatic lye TOTAL PROTEIN. Colerimetie Biurl guid TRIGLYCERIDES GPOFOD guid UREA UV SL Kineiie Enzymafe WV Liquid UREA 2 Enzymate Colorimetric Liquid RIC ACID SL Enzyatc Ti Louie SOFTWARE OVERVIEW, The SAT 450 operating softwere runs under multitasking WINDOWS XP and WINDOWS VISTA. its bright graphical user interface simplifies routine work cond offers the operator concise guide through tho cperating functions eal me presentation of samplo and recgont status dynamic monitoring of test execution eanalyzer detailed status with error messages, incubation temperaiue control, START, STOP, and PAUSE functions ‘eall parameters ore completely user programmable, 1 up b 999 mohheds can bo momerized al setings ore uer programmable euser defined insirument factors user selectable precilution and re-dilution ratio ‘euser selectable semples re-run option test calculation models ore user selectable: Factor, Standard, Linear Fit, Foint to Point, Guadratic, Cubic, Guaitic, Cubic Inv., Spline, logilegit, Exponential, log-log Cubic |AUTOMATIC DETECTION OF ‘e-antigen excess (hook effect) end point limit «substrate depletion ‘fixed lime and kinetic reaction lineerity ‘display of test reaction curves display of teat calibration curves elevyJennings QC statistics DIAGNOSTIC SOFTWARE (4) ‘s cach instrument part can be singularly torted # remale diagnostic capability in development) Used thUi « mulilangvege files {user programmable) ‘bidirectional communication compliant with ASTM standard straceability end lot management SPECIFICATIONS SYSTEM DESCRIPTION Benchtop, fully automatic, random access, open cnalyzer for clinical and immunoturbicimeric assoys EEans © End point, Kinetic, Differential, Bichrometic, Fixed Time and Immuncturbidimetric up to 999 tests, all user programmable Up to 72 reagents can be loaded into the relrigeroted ccomparhmant end disributed on: «4 removable racks wih 16 positions each (25 ml continers) 2 8 exta postions for 25 ml containers # 10/20 mi containers con be edapted SAMPLE LOADING| #4 universal, seperate eacks for continuous loading of samples, calibrators end controls « each reck cortains up bo ISeypsond/or tubes 10-16 mm diom,, 40-100 min height «8 extra pcsitons fr uigent samples clibraters and contol + Urgent sample execution is alowed at any time Up to 450 tests /hour including I.5.E. {300 tests/hour photometric} READING SYSTEM « direct reading, dua! channel photometer #200 pl minimum reading volume «9 narrow band, autematicelly seleced interferential fikers: 340, 380, 405, 450, 510, 540, 580, 620, 680 halogen lamp 6V/10W #6 mmm opiical path e linear Fom 0.0001 to 4.200 Abs. igh resolution (0.0001 Abs.) Factory: AMS stl Anolyzer Medical System 00012. Guidonia - Rome (tialy) - Vie E. Borsenti, 17/8 Tel: +39 0774 354441 Fox: +39 0774 578035 HYPERLINK “hitp://swww.oms-cnalyzers.com” email: info@amsanelyzers.com Sales & Customer Service: ASSEL srl 00012 Guidonic - Rome (aly) ~ Vie E, Barsanti, 13/A Tal: +39 0774 357492 Fox; +39 0774 372179 - 0774 376102 HYPERLINK “hitp://wvnw.osselitaly.com” email: info@asselitaly.cu ‘One mechanical arm performs all somoling operations with # liquid lovel sensing (caoccitive) © reagent preavarming at 37°C. © automatic probe washing e sample volume range: 2.0 pl + 50pl (0.25 ul incr.) ‘ereagent 1 vclume range: 3.0 pl + 330 pl {1 pl iner.| ‘reagent 2 volume ange: 3.0 pl + 330 pl (1 pl iner| ‘reagent 3 velume range: 3.0 pl + 330 pl (1 pl iner| ‘© sample precilution # sample rerun with or without dilution Holds €0 cuvettes divided into 4 racks with 20 cuvettes each ond performs the following operations: © automatic cwvelte woshing © confinyous monitoring of cuvette quality # incubation temperature control at 37°C = 0.3 [RENEE (minimum requiroments) © CPU: Pentium ll, 500 Maz © RAM Momory: 256 Mb © CD Rom: 32x © FD: 1.44 Mb, 1/3" ® HD: 20 Gb EIDE ATA ~ 3 UDMA © Printer: Windows compatible © Communication: USB and/or RS 232 pot © Software: WINDOWS XP © Direct potentiometry |.S.£, module for Na+, K+, Cl+, Lis (140 tests/hour) + Positive borcode readers fer reagents ond comples [code 128, codobar, code 2of 5 interleaved, code 39) INSTALLATION REQUIREMENTS Power Supply: 90 = 250 VAC, 47 = 63 Hz Electric consumption: 386 Watt Water Consumption: 1.5 I/h Analytical Module: © Height: 50 cm @ Wieth; 70 em @ Length: 90 em © Weight: 35 kg Room Tomporature: 18°C = 30°C Relative Humidity: 20% + 85% All the above features can be changed without prior notice, IVD ce

You might also like