Connection Design As Per Bs en 1993-1-8:2005

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 3

CONNECTION DESIGN AS PER BS EN 1993-1-8:2005

DESIGN DATA

Structural steel grade = S355


Yeid Strength = 355 N/mm²
Ultimate Tensile Strength = 430 N/mm²
Modulus of elasticity of steel , E = 210000 N/mm²

VERTICAL STUB TO MONORAIL BEAM CONNECTION


Max FX = 17.9 KN Refer Attahed staad out put
Max FZ = 0 KN
Max FY = 133.3 KN
Max Mx = 29.3 KNm
BOLT CHECK FOR SHEAR
Design Criteria = Fv,Ed < Fv,Rd

Total Design Shear Force = 17.9 KN


Number Bolt provided = 8
Dia of Bolt = 20 mm
Area of rod = 314.1593 mm²
Design Shear per Bolt (Fv,Ed) = 2.24 KN
Design shear resistance per bolt ( Fv,Rd) =

fub = 800 N/mm² Refer Table 3.1 BS EN 1993-1-8:2005


ƳM2 = 1.25 Refer Table 2.1 BS EN 1993-1-8:2005
Fv,Rd = (0.6 x 800 x 0.75 x A )/1.25
= 90.48 KN
KN <
(Fv,Ed) 2.24 KN < 90.48 KN ( Fv,Rd)
HENCE BOLT SAFE SHEAR
BOLT CHECK FOR BEARING
Design Criteria = Fv,Ed < Fb,Rd
Plate thickness (t) = 12 mm
Design Bearing Resistance per bolt ( Fb,Rd) =

Ultimate Tensile Strength (fu) = 510 N/mm²


ɑb = 1 Refer Table 3.4 BS EN 1993-1-8:2005
( Fb,Rd) = 137.088 KN
(Fv,Ed) 2.24 KN < 137.09 KN ( Fb,Rd)
HENCE BOLT SAFE BEARING
BOLT CHECK FOR TENSION
Design Criteria = Ft,Ed < Ft,Rd

Design Tension Resistance per bolt ( Ft,Rd) =

K2 = 0.63 Refer Table 3.4 BS EN 1993-1-8:2005


Design Tension Resistance per bolt ( Ft,Rd) 95.00 KN
Design of Tensile force per rod ( Ft,Ed)
Direct Tension = 133.3 KN
Direct Tension Per rod = 133.3/8
= 16.66 KN
Tension Due To moment
Bolt Neutral Axis (d/7) = 58.33 mm
top bolt c-l
Ft = M x (dmax) / d^2 bolt in tension
First row of bolt Tension (Ft1 )
Ft = 29.3 x 10^6 x222.5 /(( 222.5^2 +122.5^2+22.5^2)x2) 222.5
first row bolt Ft1 = 50.136 KN

Total Tension per rod = 66.80 KN


( Ft,Ed) = 66.80 KN
77.5 bolt in compresion
Second row of bolt Tension (Ft2 )
Ft = 25.3 x 10^6 x122.5 /(( 222.5^2 +122.5^2+22.5^2)x2)
first row bolt Ft12 = 23.88 KN
Total Tension per rod = 40.54
Third row of bolt Tension (Ft3 )
Ft = 25.3 x 10^6 x22.5 /(( 222.5^2 +122.5^2+22.5^2)x2)
first row bolt Ft1 = 2.5 KN
Total Tension per rod = 19.16 KN
( Ft,Ed) = 66.80 KN

( Ft,Ed) 66.80 KN < 95.00 KN ( Ft,Rd)


HENCE BOLT SAFE TENSION
BOLT COMBINE SHEAR AND TENSION CHECK
Fv,Ed + Ft,Ed <1
Fv,Rd 1.4x Ft,Rd
2.2375 + 66.80 = 0.53
90.48 133.00
HENCE BOLT SAFE IN COMBINE SHEAR AND TENSION

WELD CAPACITY CHECK


Design Criteria = Fw,Ed < Fw,Rd
Design weld resistance per unit length (Fw,Rd) = fvw.d x a
fvw.d = 220 0 Refer clause 4.5.3.3 BS EN 1993-1-8:2005
a = 6 mm
Fw,Rd = 1320 N/mm
Length of the weld = 250 mm
Total weld resistance (Fw,Rd) = 330 KN
> 253.01 KN
HENCE OK

PLATE CHECK FOR BENDING

N,Ed = 271 KN (Total Tension for two Bolt)


Maximum length of plate between column web to Bolt line( c ) = 20
Maximum Moment (Mpl,1,Rd,u) = 271x0.025
= 5.42 KNm
Thickness of Plate provided 16+16 = 32 mm
=
Thickness of Plate required = 1.1x8.13
0.25x0.1x3555x1000
= 25.92 mm
Provided Plate Thickness = 32 mm
Hence Safe

You might also like