Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10

LONTAR EXTENSION COAL FIRED


A
STEAM POWER PLANT (1X315MW) A

PIPING AND INSTRUMENT DIAGRAM INDEX

TABLE OF CONTENTS

B&V DWG. NO. TITLE B&V DWG. NO. TITLE

B B
189963-4UUU-M2000 INDEX 189963-4HNC-M2145 INDUCED DRAFT

189963-4UUU-M2001A,B LEGEND 189963-4HAN-M2586A,B,C BOILER VENTS AND DRAINS

189963-4LBA-M2587 MAIN STEAM 189963-4SGA-M2361A,B PLANT FIRE PROTECTION

189963-4LBB-M2590 HOT REHEAT STEAM 189963-CSGA-M2547A,B,C SITE FIRE PROTECTION

189963-4LBC-M2591 COLD REHEAT STEAM 189963-CSGA-M2665 FIRE PROTECTION-MAIN PUMPS

189963-4LAB-M2341A,B BOILER FEED WATER 189963-CSGB-M2666 FIRE PROTECTION-SEAWATER MAIN PUMPS

189963-4LBG-M2061A,B,C AUXILIARY STEAM 189963-4SGA-M2667 FIRE PROTECTION-BOOSTER PUMPS

C 189963-4LBQ-M2601 HP EXTRACTION STEAM C


189963-4GAA-M2660 SEA WATER SUPPLY

189963-4LBS-M2602A,B LP EXTRACTION STEAM


189963-4QJA-M2201 HYDROGEN SUPPLY

189963-4LCH-M2604A,B HP HEATER DRAINS


189963-4QJF-M2204 NITROGEN SUPPLY

189963-4LCJ-M2605A,B,C LP HEATER DRAINS


189963-4GDK-M2640A,B,C WASTE WATER COLLECTION

189963-4LCM-M2606A,B,C HEATER VENTS & MISC DRAINS


189963-4LBK-M2594A,B,C,D,E TEMPORARY BLOWOUT

189963-4LCA-M2343A,B,C,D,E CONDENSATE
189963-4LAN-M2621 BFP STEAM DRIVEN TURBINE EXHAUST DUCT

189963-4MAJ-M2262 CONDENSER AIR EXTRACTION


189963-4GQB-M2642 SANITARY DRAINAGE COLLECTION

189963-4MAJ-M2267 COOLING WATER VACUUM PRIMING


D
189963-4HAF-M2483 VACUUM CLEANING SYSTEM D

189963-4EGA-M2401 FUEL OIL UNLOADING


CIVIL
CONTRACTOR DOCUMENT REVIEW
189963-4EGB-M2402 FUEL OIL TRANSFER R MECH
E
LOG DATE : V ELECT
189963-4EGC-M2403 FUEL OIL SUPPLY I
IN COMM NO : E I&C
W
189963-4QEA-M2180A,B COMPRESSED AIR GENERATION A APPROVED SUPPORT

B APPROVED AS NOTED CONTRACTOR


189963-4QEB-M2181A,B,C,D SERVICE AIR DISTRIBUTION
C NOT APPROVED RECORD
D
189963-4QFD-M2182A,B,C,D,E INSTRUMENT AIR DISTRIBUTION I
I INFORMATION WORKING DOCUMENT
S
T
APPROVAL DOES NOT RELIEVE CONTRACTOR R
189963-4PAB-M2263A,B,C,D,E CIRCULATING WATER I
FROM RESPONSIBILITY FOR ERROR OR
DEVIATIONS FROM CONTRACT B
E REQUIREMENTS U E
189963-4PCB-M2321 AUXILIARY COOLING WATER T
I
BY DATE : O
189963-4PGA-M2322A,B,C,D,E,F,G CLOSED CYCLE COOLING WATER N
LOG DATE :

189963-4GHB-M2663A,B,C,D SERVICE WATER OUT COMM NO :

189963-4GKB-M2664A,B,C POTABLE WATER

189963-4GUB-M2644A,B OILY WASTE WATER COLLECTION 1 09-NOV-2018 ISSUED FOR OWNER APPROVAL CTL CTL PJ JZ XL

0 B 09-JAN-2017 ISSUED FOR OWNER APPROVAL JZX JZX JZ


189963-4LCD-M2346A,B CYCLE MAKEUP & STORAGE
NO STATUS DATE REVISIONS AND RECORD OF ISSUE DRN DES CHK PDE APP

F
189963-4GCF-M2661 RAW WATER SUPPLY
PT. PERUSAHAAN LISTRIK NEGARA (PERSERO)
AGENCY OF THE MINISTRY OF MINES AND ENERGY
189963-4MAL-M2261A,B,C,D TURBINE VENT AND DRAIN GOVERNMENT OF THE REPUBLIC OF INDONESIA
F

APPROVED FOR LONTAR EXTENSION COAL FIRED STEAM POWER PLANT(1X315MW)


578

189963-4MAV-M2624A,B TURBINE LUBE OIL PURIFICATION CONTRACT NO : 0436.PJ/DAN.02.01/DIR/2015


9.
11.

189963-4MAW-M2623A,B TURBINE GLAND SEALS AND DRAINS


CONSTRUCTION PT. PLN (PERSERO)
on v8.

PUSAT ENJINIRING KETENAGALISTRIKAN


THE DISTRIBUTION AND USE OF THE NATIVE FORMAT CAD
1 0 0 9 8 - 0 0 -M - 5 2 - H A - 0 1 - 0 1
croStati

FILE OF THIS DRAWING IS UNCONTROLLED. THE USER PLN DWG No.


SHALL VERIFY TRACEABILITY OF THIS DRAWING TO THE
OWNER DRAWING TITLE OWNER DRAWING NUMBER OWNER REV NO
1=1

LATEST CONTROLLED VERSION.


Mi

44 PM

B&V DRAWING NUMBER B&V REV NO


15:

LONTAR EXTENSION
11/9/2018 4:

R
R
COAL FIRED STEAM POWER PLANT (1X315MW) 189963-4UUU-M2000 1
che85882

DESIGNER DRAWN CODE


PIPING AND INSTRUMENT DIAGRAM
CTL CTL
INDEX
CHECKED DATE AREA
A1

09-NOV-2018