Project Scope of Work: Residential Remodel 6071 Baldwin Ave Riverside, CA 92509 USA
Project Scope of Work: Residential Remodel 6071 Baldwin Ave Riverside, CA 92509 USA
Project Scope of Work: Residential Remodel 6071 Baldwin Ave Riverside, CA 92509 USA
PROPERTY INFORMATION
PROPERTY TYPE
SINGLE FAMILY RESIDENTIAL.
GENERAL NOTES
PROJECT DIRECTORY
RESIDENTIAL REMODEL
NEEDING CLARIFICATION SHALLBE REPORTED TO THE Laura A. Quiroz / (909) 349-0799
OWNER PRIOR TO THE BEGINNING WORK.NO ALLOWANCE
SHALL BE GIVEN FOR FAILURE TO COMPLY WITH THE ENGINEER OF RECORD:
187'-1
ABOVE OR ANY CONDITIONS THAT CAN BE DETERMINED Fredy Orellana, P.E w/ Oconsulting LLC
0"
EXAMINING THE SITE, DRAWINGS, AND SPECIFICATIONS. (949) 754-2826
fredy@oconsultingengineering.com
2)THE CONTRACTOR AND SUB-CONTRACTOR SHALL
VERIFY ALL DIMENSIONS ON THE DRAWINGS. AND SHALL PROPERTY INFORMATION
IMMEDIATELY NOTIFY THE OWNER OF ANY ADDRESS
EXISTING ONE STORY SINGLE FAMILY RESIDENTIAL 6071 Baldwin Ave Riverside, CA 92509 USA
DISCREPANCIES PRIOR TO CONSTRUCTION LAYOUT. NO TOTAL=1469.00 SQ FT
ALLOWANCE SHALL BE GIVEN TO THE CONTRACTOR OR ASSESOR'S ID:
TWO CAR GARAGE = 784.00 SQ FT
SUBCONTRACTOR FOR CHANGES RESULTING FROM
FAILURE TO COMPLY W/ THESE REQ'MTS NEW ROOM ADDITION = 495.20 SQ FT PROPERTY BOUNDARY DESCRIPTION
LOT 5 MB 159 / 058 TRACK 20122
3) DO NOT SCALE THE DRAWINGS. ALL DIMENSION
SPECIFIED GOVERN. DIMENSIONS ARE NOMINAL AND ARE 3" EXISTING PROPERTY SQUARE FOOTAGE
38'-
TO THE FACE OF OBJECTS UNLESS OTHERWISE 1,469.00 SQ.FT
INDICATED. 784.00 SQ FT TWO CAR GARAGE
30'-9"
ADDITION SQUARE FOOTAGE
495.20 SQ.FT
17'-7"
1 "
15'-
12"
22'-8" 1/4"
32'
12'-6"
12" TWO
3" 12"
CAR
12'-2"
3"
26'-5"
GARGE
EXISTING
21'-2" 30' 3"
12"
ADDITION)
22'
3"
10"
SHEET INDEX
12"
12"
10'-9"
24'-
1/4"
IRVINE, CA 92618
A1.0 FLOOR PLAN AND ROOF PLAN (949) 754-2826
E
WIN
AVE
NE OF BALDWIN AV
A2.0 ELEVATIONS
ALD
SHEET TITLE
DWIN
F BAL
EO
LINE
ENT
56'-1" TO CENTER LI
E
TO C
40'-
TS
48'-3"
1/16"=1'-0"
S=2.00%
GEOS TO EXISTING WASTE
WATER SYSTEM
G.T.
Ø2''
WINDOW SCHEDULE
W TYPE REMARKS
1 48" X 48" HORIZONTAL SLIDE EGRESSED, SCREEN
(N)BEDROOM 2 36" X 36" HORIZONTAL SLIDE, SCREE
(N)LIVING
3 48" X 36" HORIZONTAL SLIDE EGRESSED, SCREEN
4 24" X 36" FIXED, SCEEN
5 24" X 12" HORIZONTAL SLIDE OBSCURED, SCREEN
6 26" x 48" FIXED, SCEEN
NEW
s (ROOM EXISTING DOOR SCHEDULE
(N)BATH ROOM
ADDITION) D SIZE REMARKS
(N)WALK-IN 1 24" X 80" PRE-HUNG INTERIOR DOOR, WITH 6 RAISED PANELS
2 30" X 80" PRE-HUNG STELL ENTRY DOOR, WITH RAISED PANELS
S.D. C.M.
(E)DINNIG (E)KITCHEN 3 30" X 80" PRE-HUNG INTERIOR DOOR, WITH 6 RAISED PANELS
Ø4'' Ø2''
Ø2''
S=2.00%
Ø4''
GEOS TO EXISTING WASTE
S= WATER SYSTEM
1.
00%
NEW
(E)MASTER BEDROOM SIMBOLOGY
(E)MASTER BATH
S.D.
S.D. (E)GARAGE
SD
(E) BATH SMOKE DETECTOR
S.D. C.M.
NEW WALL / DOOR OPENING BEING CLOSED
RESIDENTIAL REMODEL
(N)BEDROOM (N)LIVING S.D. C.M.
Ø1/2'' (E)LIVING
(N)BEDROOM (N)LIVING
4'
s D3 (E)BEDROOM (E)BEDROOM
(N)BATH ROOM
D1
S.D. S.D.
9'-6"
D3 D3
(N)WALK-IN
s
(N)BATH ROOM
S.D.
(N)WALK-IN W6
PLUMBING PIPE HOT WATER SUPLY PIPE THE CONSTRUCTION SHALL NOT
VERTICAL TEE.
RESTRICT A FIVE-FOOT CLEAR AND
HORIZONTAL TEE.
UNOBSTRUCTED ACCESS TO ANY
12"
HORIZONTAL TEE. HORIZONTAL ELBOW. WATER OR POWER DISTRIBUTION
1/4"
FACILITIES (POWER POLES,
HORIZONTAL Y BRANCH. VERTICAL ELBOW.
PULL-BOXERS,TRANSFORMERS,
VERTICAL ELBOW. VERTICAL TEE. VAULTS, PUMPS, VALVES, METERSM
APPURTENANCES, ETC.) OR TO THE
HORIZONTAL ELBOW.
LOCATION OF THE HOOK-UP. THE
HORIZONTAL 45 ELBOW NEW CONSTRUCTION SHALL NOT BE
(ROOM EXISTING WITHIN TEN FEET OF ANY POWER.
SIPHON ADDITION)
FAILURE TO COMPLY MAY CAUSE
PIPE REDUCER. CONSTRUCTION DELAYS AND/OR
12" ADITIONAL EXPENSES.
3" 12"
3" AN APROVED SEISMIC GAS SHUT
OFF VALVE OR EXCESS FLOW SHUT
OFF VALVE WILL BE INSTALLED ON
s
(N)BEDROOM
THE FUEL GAS LINE ON THE
(N)LIVING
S.D. C.M. S.D. C.M.
12" DOWN-STREAM SIDE OF THE UTILITY
3" METER AND BE RIGIDLY CONNECTED
TO THE EXTERIOR OF THE BUILDING
s
IRVINE, CA 92618
FUEL GAS PIPING.( PER (949) 754-2826
3"
ONRDENANCE 170,158 AND
s s
(N)BATH ROOM
12"
(N)WALK-IN
S.D.
180,670)(INCLUDES COMMERCIAL SHEET TITLE
ADDITIONS AND TI WORK OVER
$10,000.) SEPARTE PLUMBING
PERMIT IS REQUIRED. FLOOR PLAN AND ROOF
3"
ELECTRICAL PLAN 12" PLAN
12"
1/4" = 1'-0"
SYMBOLOGY 1/4" PROVIDE ULTRA-FLUSH WATER
CLOSET FOR ALL NEW
s TWO POLE SW ITCH
CONSTRUCTION. EXISTING SHOWER
s SINGLE POLE SWITCH HEADS AND TOILETS MUST BE
LIGHT FIXTURE
110V DUPLEX CONVENIENCE OUTLET WITH GROUND FAULT
ADAPTED FOR LOW WATER
CONSUMPTION. A1.0
INTERUPTER H = 1' WATER HEATER MUST BE STRAPPED
110V DUPLEX CONVENIENCE OUTLET WITH GROUND FAULT ROOF PLAN TO WALL(SEC. 507.3 & LAPC)
INTERUPTER H = 4'
W
NEW
NEW
(ROOM EXISTING
ADDITION)
S.D. C.M.
(E)DINNIG (E)KITCHEN
N
S
(E)MASTER BEDROOM
(E)MASTER BATH
S=2.00%
S.D.
GEOS TO EXISTING WASTE
S.D. (E)GARAGE
WATER SYSTEM
(E) BATH S.D.
G.T.
(E) CLOSET S.D.
Ø1/2''
Ø2''
s
S.D. C.M.
(E)LIVING
(N)BEDROOM (N)LIVING
Ø1/2'' S.D. C.M. S.D. C.M.
s
(E)BEDROOM (E)BEDROOM
S.D. S.D.
s s
(N)BATH ROOM
S.D.
(N)WALK-IN
Ø4'' Ø2''
COMES FROM EXISTING
Ø1/2'' Ø2''
S=2.00%
WATTER SUPPLAY SYSTEM
Ø4''
3"
3" 3"
3" 3"
12"
1/4" 12"
E
12" 12" 1/4" 12"
EXISTING CLAY TILE ROOF
EXISTING CLAY TILE ROOF COMPOSITION ROLL ROOFING OVER TWO
12" 12" LAYER 15# FELT HOT MOPPED
ROOM ADITION
EXISTNG EXISTNG
EXISTNG EXISTNG
EXISTNG
3'
8'-11"
T.T.P.8'
8'-6"
5'-6"
(E)
STUCCO
3'-8"
*STUCCO
1'-6"
RESIDENTIAL REMODEL
NEW
(ROOM
EXISTING
ADDITION)
EXISTING CLAY TILE ROOF
3'
3'
(E)
8'-6"
(E)
6'-8"
(E)
7'
7'
7'
(E)
STUCCO STUCCO STUCCO
(E) *STUCCO
3'-8"
WEST ELEVATION
NEW
EXISTING
(ROOM
ADDITION)
EXISTING CLAY TILE ROOF
SHEET TITLE
2' 2' 4'-3" 2'-2" 6' 6' 3' 5' 16' 9'
1'
ELEVATIONS
8'-11"
5'-6"
5'-6"
4'
4'
7'
5'-8"
(E)
(E)
(E)
2'-8"
2'-8"
1'-6"
1'-6"