Active Humidification: For Adult, Pediatric & Infant Respiration
Active Humidification: For Adult, Pediatric & Infant Respiration
Active Humidification: For Adult, Pediatric & Infant Respiration
Active Humidification
for Adult, Pediatric & Infant Respiration
nice 8010
nice 8050
80-05-015 80-05-016
Infant / Neonatal disposable Auto feed Adult / Pediatric disposable Auto feed
Humidification chamber (optional) Humidification chamber (optional)
Application
Infant T-Piece Resuscitator with Air/O2 Blender and
Respiratory Humidifier.
Provides a warmed and humidified flow
of air-oxygen mixture to the infant
Respiratory Care range of product
illustrates the breathe of Respiratory
therapies patients may require when
in need of Respiratory assistance.
nice 8050 Humidifier Features
Temperature Probe
Designed for use in hospital environment wherever The nice 8050 & nice 8010 accommodates both
80-05-003 with Flow Sensor medical gas is being supplied to patients, nice 8050 high and low flow ventilation therapies, as well as
heated and non heated wire breathing system.
& nice 8010 heated wire humidifier incorporates
nice 8010 Humidifier
latest technology that provides Physiological level of Two type of humidification chamber to use the
Temperature Probe therapy to meet the patient particular needs.
80-05-006 humidity at body temperature.
Humidifier The nice 8050 features dual servo control feedback Reusable/Disposable Adult chamber - for
Temperature Probe system, incorporates to constant monitoring and pediatric & adult respiratory application
MR730 control chamber and proximal temperatures in the
airway line. As a result high temperature gases Reusable/Disposable Infant chamber - for
80-05-007 Compatible
cannot exist anywhere in the system. When use a Pediatrics and Neonatal application
2pin Heater Wire heated wire breathing system from nice 8050,
ventilated gas continues to warm during delivery. The nice 8050 & 8010 delivers precise, reliable
Adapter for disposable
Rain-out and waste are reduced, while the need for performance. An advanced microprocessor
breathing Circuit
80-05-005 circuit change is minimized.
controller assures the control of the system. The
3pin Heater Wire Comprehensive audible & visual alarm constantly system responds immediately to any change in
Adapter for disposable protects against potential problems. The nice 8050 settings, and constant self diagnostic verify proper
will alert at variations of set temperature Vs actual.
80-05-010 breathing Circuit operation every second of use. High and low
The design of nice 8050 & nice 8010 makes it the temperature protection is assured throughout
2pin Heater Wire
ideal humidification system for Adult Ventilator, Infant
Adapter for Reusable Ventilator, Infant Resuscitator & Oxygen Therapy for operation, including warm up and setting changes.
Adult, Paediatric & Neonatal care. If the delivery temperature exceed 41º C
breathing Circuit
80-05-004
Neotech
74-00-020, Rev 03