Active Humidification: For Adult, Pediatric & Infant Respiration

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Neotech

Active Humidification
for Adult, Pediatric & Infant Respiration

nice 8010

nice 8050

Heated Wire & Non Heated Wire


Invasive & Non Invasive Mode Flow detection
nice 8050 nice 8010
Servo Control Servo control
Heated (Respiratory)Humidifier Heated (Respiratory)Humidifier
Invasive & Non Invasive Application Non Invasive Application
Adult Care & Pediatric Care Adult Care
Capable of operating in either invasive or non invasive Capable of operating in non invasive application
application with invasive and non invasive mode. with low, medium & high temperature setting.
It can be used for non invasive ventilation and
It can be used for invasive ventilation, non invasive
oxygen therapy with absolute humidity > 12 mg/l
ventilation and oxygen therapy with
obsolute humidity > 12 mg/l
Infant Care
Infant Care Capable of operating in non invasive Application
Capable of operating in either invasive and non invasive with low, medium & high temperature setting.It can be
used for Infant Resuscitation, and Oxygen therapy with
control mode with flow detection. It can be used for
absolute Humidity > 12 mg/l
invasive ventilation, Infant Bubble CPAP, Resuscitation,
and Oxygen therapy with absolute Humidity > 33 mg/l
nice 8020 nice 8030
Reusable Paediatric/Neonatal Humidification Reusable Adult Humidification
Chamber (optional) Chamber (optional)
Auto clavable low compressible volume humidifying Auto clavable humidifying chamber with peak
chamber. flow bypass.
Chamber compressible Volume for high flow 360ml. Chamber compressible Volume for high flow 700ml.
Maximum water capacity 230ml. Maximum water capacity 280ml.
360 deg viewable water line for ease to monitor 360 deg viewable water line for ease to monitor
the water level from all angles. the water level from all angles.
Highly durable intended for multiple usages. Highly durable intended for multiple usages.
Withstands prolonged exposures to high temperature Withstands prolonged exposures to high temperature
and repeated sterilization. and repeated sterilization.
Water fill port for refilling water during operation. Water fill port for refilling water during operation.
Bio-compatible material minimizes risk on patient Bio-compatible material minimizes risk on patient
with safer material. with safer material.

Humidification Chamber Disposable

80-05-015 80-05-016

Infant / Neonatal disposable Auto feed Adult / Pediatric disposable Auto feed
Humidification chamber (optional) Humidification chamber (optional)

Application
Infant T-Piece Resuscitator with Air/O2 Blender and
Respiratory Humidifier.
Provides a warmed and humidified flow
of air-oxygen mixture to the infant
Respiratory Care range of product
illustrates the breathe of Respiratory
therapies patients may require when
in need of Respiratory assistance.
nice 8050 Humidifier Features
Temperature Probe
Designed for use in hospital environment wherever The nice 8050 & nice 8010 accommodates both
80-05-003 with Flow Sensor medical gas is being supplied to patients, nice 8050 high and low flow ventilation therapies, as well as
heated and non heated wire breathing system.
& nice 8010 heated wire humidifier incorporates
nice 8010 Humidifier
latest technology that provides Physiological level of Two type of humidification chamber to use the
Temperature Probe therapy to meet the patient particular needs.
80-05-006 humidity at body temperature.
Humidifier The nice 8050 features dual servo control feedback Reusable/Disposable Adult chamber - for
Temperature Probe system, incorporates to constant monitoring and pediatric & adult respiratory application
MR730 control chamber and proximal temperatures in the
airway line. As a result high temperature gases Reusable/Disposable Infant chamber - for
80-05-007 Compatible
cannot exist anywhere in the system. When use a Pediatrics and Neonatal application
2pin Heater Wire heated wire breathing system from nice 8050,
ventilated gas continues to warm during delivery. The nice 8050 & 8010 delivers precise, reliable
Adapter for disposable
Rain-out and waste are reduced, while the need for performance. An advanced microprocessor
breathing Circuit
80-05-005 circuit change is minimized.
controller assures the control of the system. The
3pin Heater Wire Comprehensive audible & visual alarm constantly system responds immediately to any change in
Adapter for disposable protects against potential problems. The nice 8050 settings, and constant self diagnostic verify proper
will alert at variations of set temperature Vs actual.
80-05-010 breathing Circuit operation every second of use. High and low
The design of nice 8050 & nice 8010 makes it the temperature protection is assured throughout
2pin Heater Wire
ideal humidification system for Adult Ventilator, Infant
Adapter for Reusable Ventilator, Infant Resuscitator & Oxygen Therapy for operation, including warm up and setting changes.
Adult, Paediatric & Neonatal care. If the delivery temperature exceed 41º C
breathing Circuit
80-05-004

Specification nice 8050 nice 8010


Recommended Gas Flow Range up to 60 LPM for Invasive Mode
up to 120 LPM for Noninvasive Mode up to 60 LPM

Mode of operation Invasive &Noninvasive Low, Standard & High


Temperature Control Settings Temperature & Humidity setting performance (at 23°C Ambient Temperature)
Chamber outlet set point 36 - 42°C for Invasive Mode Constant Flow Delivered patient
Setting
32 - 36°C for Noninvasive Mode range (L/min) temperature (°C)
Airway set point 35 - 40°C for Invasive Mode Low 5 to 60 28 to 32
31 - 35°C for Noninvasive Mode Heater wire Mode Standard 5 to 60 29 to 33
Temperature Display Range High 5 to 30 32 to 35
15 to 70°C
Temperature Accuracy Accuracy ±0.3°C (in 25 to 45°C range) Low 5 to 60 24 to 26
Non-
Standard 5 to 40 26 to 29
Heater wire Mode
High 5 to 30 27 to 31
Humidity Performance >33 mg/L for Invasive Mode >12 mg/L @ 5 to 60 L/min
>12 mg/L for Noninvasive Mode
Heater Plate 150VA 150VA
Heater Wire AC24V, 60VA AC24V, 60VA
Input Supply Voltage AC230V, 50Hz, AC230V, 50Hz,
Warm-up Time Less than 30 minutes Less than 30 minutes
Alarms High Humidity, Low Humidity, Ambient Temperature High, Ambient
Probe Fail, No Gas Flow, Heater Fault, Temperature Low, Probe Fail, Heater Fault,
Heater Wire Fault, Add Water. Heater Wire Fault.
Operating Temperature 18 to 26°C 18 to 26°C
Storage Temperature -10 to 50°C -10 to 60°C
Operating Humidity 15 to 90% RH, Noncondensing 15 to 90% RH, Noncondensing
Storage Humidity 50 to 90% RH, Noncondensing 50 to 90% RH, Noncondensing
MDD – Product Classification Class Ilb Class IIb
Quality Management System ISO 13485:2016 ISO 13485:2016
Electrical Safety Standard IEC 60601-1 IEC 60601-1
EMC Safety Standard IEC 60601-1-2 IEC 60601-1-2
Device Specific standard ISO 80601-2-74 ISO 80601-2-74
Dimension(without Chamber) 13.5 cm (L) X 16.5 cm (D) X 15.5 (H) 13.5 cm (L) X 16.5 cm (D) X 15.5 (H)
Weight 3kgs 3kgs
Protection against ingress of liquid IPX1 IPX1
Maximum operating pressure 20kPa 20kPa
Gas leakage @ Maximum pressure <100ml / min <100ml / min

Neotech
74-00-020, Rev 03

An ISO 13485 Certified Company (With Design)


Regd. Office & Factory: No. 85, Krishna Industrial Estate, Mettukuppam, Vannagaram, Chennai 600095. INDIA.
Tel.: +91-44-24762594, 24764608, Fax: +91-44-24766920, www.niceneotech.com.
E-mail info@niceneotech.com, marketing@niceneotech.com,
Toll Free:1800-425-2594

You might also like