DATA TRB 2 588487 4 April 2019
DATA TRB 2 588487 4 April 2019
DATA TRB 2 588487 4 April 2019
7 Beban Perpipaan
Main Deck 100 psf
Cellar Deck 75 psf
Sub cellar deck
8 Helideck 1
Type Sikorsky/Hughes
Rules API RP 2L
CELLAR DECK
No. Description Jumlah Berat (Kip) Ukuran
1 Gas Cooler 1 15.68 OD 38'' x 20'-0''
2 Emergency generator 1 20.16 22'-0'' x 9'-0'' x 10'-11''
3 Battery box 1 1 1.79 2'-3'' x 2'-3'' x 1'-9''
4 Battery box 2 1 1.79 2'-3'' x 2'-3'' x 1'-9''
5 Vertical separators 1 1 36.77 OD 54'' x 8'-4''
6 Vertical separators 2 1 36.77 OD 54'' x 8'-4''
7 Maintenance building 1 44.80 12'-3'' x 6'-4'' x 8'-0''
8 Switch gear 1 7.84 5'-0'' x 2'-2'' x 8'-10''
9 Switch gear building 1 5.04 26'-0'' x 24'-0'' x 14'-0''
10 Switch gear building 1 6.72 7'-0'' x 18'-0'' x 13'-6''
11 Diesel fuel tank 1 58.24 10'-0'' x 10'-0'' x 10'-0''
12 Toilet 1 2.24 4'-0'' x 6'-0'' x 8'-0''
13 Transformer-1 1 92.00 16'-6' x 12'-10'' x 12'-0''
14 Transformer-2 1 12.00 9'-0'' x 5'-0'' x 6'-9''
15 Vertical air receiver 1 1.20 OD 38'' x 6'-4''
MAIN DECK
No. Description Jumlah Berat (Kip) Ukuran
1 Battery box 1 1 1.79 2'-3'' x 2'-1' x 1'-9''
2 Battery box 2 1 1.79 2'-3'' x 2'-1' x 1'-9''
3 Air compressor package 1 5'-8'' x 3'-6'' x 6'-0''
3.36
4 Load break switch 1 1.19 4'-6'' x 2'-5'' x 6'-5''
5 Container room-1 1 23.52 34'-0'' x 10'-0'' x 20'-0'
6 Container room-2 1 23.52 34'-0'' x 10'-0'' x 20'-0'
7 Process control room 1 9.24 16'-0'' x 14'-0'' x 12'-0''
8 Transformer 1 19.23 12'-6'' x 8'-0'' x 8'-0''
9 Instrument storage 1 5.60 8'-0'' x 6'-8'' x 6'-6''
10 Fresh water tank 1 7.09 11'-6'' x 8'-0'' x 10'-0''
11 Air receiver 1 1.20 OD 36'' x 75''
12 Ansul drum chemical skid 1 9'-3'' x 5'-2'' x 4'-5''
2.47
13 Mechanical storage 1 7.84 8'-2'' x 8'-1'' x 8'-9''
14 Life capsule 1 2.69 …
15 Communication microwave 1 10'-4'' x 10'-0'' x 9'-10''
5.38
16 Communication tower 1 17.92 10'-5'' x 10'-5'' x 100'-0''
17 Fuel tank 1 13.44 5'-7'' x 4'-5'' x 4'-7''
18 Power instrument storage 1 8'-2'' x 8'-2'' x 9'-0''
4.44
19 Toilet 1 2.24 5'-0'' x 4'-0'' x 8'-0''
20 Flare bridge 1 … …
EQUIPMENT SIZE
I. CELLAR DECK
SIZE
No. Description Jumlah Berat (Kip) Ukuran LENGTH WIDTH
feet inch feet
1 Gas Cooler 1 15.68 OD 38'' x 20'-0'' 38
2 Emergency generator 1 20.16 22'-0'' x 9'-0'' x 10'-11'' 22 9
3 Battery box 1 1 1.79 2'-3'' x 2'-3'' x 1'-9'' 2 3 2
4 Battery box 2 1 1.79 2'-3'' x 2'-3'' x 1'-9'' 2 3 2
5 Vertical separators 1 1 36.77 OD 54'' x 8'-4'' 54
6 Vertical separators 2 1 36.77 OD 54'' x 8'-4'' 54
7 Maintenance building 1 44.80 12'-3'' x 6'-4'' x 8'-0'' 12 3 6
8 Switch gear 1 7.84 5'-0'' x 2'-2'' x 8'-10'' 5 2
9 Switch gear building 1 5.04 26'-0'' x 24'-0'' x 14'-0'' 26 24
10 Switch gear building 1 6.72 7'-0'' x 18'-0'' x 13'-6'' 7 18
11 Diesel fuel tank 1 58.24 10'-0'' x 10'-0'' x 10'-0'' 10 10
12 Toilet 1 2.24 4'-0'' x 6'-0'' x 8'-0'' 4 6
13 Transformer-1 1 92.00 16'-6' x 12'-10'' x 12'-0'' 16 6 12
14 Transformer-2 1 12.00 9'-0'' x 5'-0'' x 6'-9'' 9 5
15 Vertical air receiver 1 1.20 OD 38'' x 6'-4'' 38
I. CELLAR DECK
SIZE
WIDTH HEIGHT No. Description Jumlah Berat (Kip)
inch feet inch
38 20 1 Gas Cooler 1 15.68
10 11 2 Emergency generator 1 20.16
3 1 9 3 Battery box 1 1 1.79
3 1 9 4 Battery box 2 1 1.79
54 8 4 5 Vertical separators 1 1 36.77
54 8 4 6 Vertical separators 2 1 36.77
4 8 7 Maintenance building 1 44.80
2 8 10 8 Switch gear 1 7.84
14 9 Switch gear building 1 5.04
13 6 10 Switch gear building 1 6.72
10 11 Diesel fuel tank 1 58.24
8 12 Toilet 1 2.24
10 12 13 Transformer-1 1 92.00
6 9 14 Transformer-2 1 12.00
38 6 4 15 Vertical air receiver 1 1.20
SIZE
Ukuran I. CELLAR DECK
LENGTH (ft) WIDTH (ft) HEIGHT (ft)
No. Description
OD 38'' x 20'-0'' 3.17 3.17 20 1 Gas Cooler
22'-0'' x 9'-0'' x 10'-11'' 22 9 10.92 2 Emergency generator
2'-3'' x 2'-3'' x 1'-9'' 2.25 2.25 1.75 3 Battery box 1
2'-3'' x 2'-3'' x 1'-9'' 2.25 2.25 1.75 4 Battery box 2
OD 54'' x 8'-4'' 4.50 4.50 8.33 5 Vertical separators 1
OD 54'' x 8'-4'' 4.50 4.50 8.33 6 Vertical separators 2
12'-3'' x 6'-4'' x 8'-0'' 12.25 6.33 8 7 Maintenance building
5'-0'' x 2'-2'' x 8'-10'' 5 2.17 8.83 8 Switch gear
26'-0'' x 24'-0'' x 14'-0'' 26 24 14 9 Switch gear building
7'-0'' x 18'-0'' x 13'-6'' 7 18 13.50 10 Switch gear building
10'-0'' x 10'-0'' x 10'-0'' 10.00 10.00 10 11 Diesel fuel tank
4'-0'' x 6'-0'' x 8'-0'' 4.00 6.00 8 12 Toilet
16'-6' x 12'-10'' x 12'-0'' 16.50 12.83 12 13 Transformer-1
9'-0'' x 5'-0'' x 6'-9'' 9.00 5.00 6.75 14 Transformer-2
OD 38'' x 6'-4'' 3.17 3.17 6.33 15 Vertical air receiver
Total
SIZE
Ukuran II. MAIN DECK
LENGTH (ft) WIDTH (ft) HEIGHT (ft)
No. Description
2'-3'' x 2'-1' x 1'-9'' 2.25 2.08 1.75 1 Battery box 1
2'-3'' x 2'-1' x 1'-9'' 2.25 2.08 1.75 2 Battery box 2
5'-8'' x 3'-6'' x 6'-0'' 3 Air compressor package
5.67 3.50 6
4'-6'' x 2'-5'' x 6'-5'' 4.50 2.42 6.42 4 Load break switch
34'-0'' x 10'-0'' x 20'-0' 34.00 10.00 20 5 Container room-1
34'-0'' x 10'-0'' x 20'-0' 34.00 10.00 20 6 Container room-2
16'-0'' x 14'-0'' x 12'-0'' 16.00 14.00 12 7 Process control room
12'-6'' x 8'-0'' x 8'-0'' 12.50 8.00 8 8 Transformer
8'-0'' x 6'-8'' x 6'-6'' 8.00 6.67 6.50 9 Instrument storage
11'-6'' x 8'-0'' x 10'-0'' 11.50 8.00 10 10 Fresh water tank
OD 36'' x 75'' 3.00 3.00 6.25 11 Air receiver
9'-3'' x 5'-2'' x 4'-5'' 12 Ansul drum chemical skid
9.25 5.17 4.42
8'-2'' x 8'-1'' x 8'-9'' 8.17 8.08 8.75 13 Mechanical storage
… 0.00 0.00 0 14 Life capsule
10'-4'' x 10'-0'' x 9'-10'' 15 Communication microwave
10.33 10.00 9.83
10'-5'' x 10'-5'' x 100'-0'' 10.42 10.42 100 16 Communication tower
5'-7'' x 4'-5'' x 4'-7'' 5.58 4.42 4.58 17 Fuel tank
8'-2'' x 8'-2'' x 9'-0'' 18 Power instrument storage
8.17 8.17 9
5'-0'' x 4'-0'' x 8'-0'' 5.00 4.00 8 19 Toilet
… 0.00 0.00 0 20 Flare bridge
Total
EQUIPMENT AREAS
Amount Weigth (kips) Area (ft2) Luas Yang Digunakan Area (ft2)
1 15.68 7.87 Cellar Deck 1474.83
1 20.16 198 Main Deck 1633.48
1 1.79 5.06
1 1.79 5.06
1 36.77 15.90
1 36.77 15.90
1 44.80 77.58
1 7.84 10.83
1 5.04 624
1 6.72 126
1 58.24 100
1 2.24 24
1 92.00 211.75
1 12.00 45
1 1.20 7.87
Total 1474.83
Possible Size for Cellar Deck (1800 ft2) Ukuran Deck Length Width
Length Width Area (ft2) Cellar Deck 50 56
50 56 2800 Main Deck 50 56
0
2
0.570 0.570
3
10.0074
9.252 0.653 4.049 13.955
9
10
2.271733
13
0.311 3.937
3.626662
4.000538
14
4.000538
15
3.626662
3.626662
Total 10.0074 11.25386 0.903 1.183 23.42038 23.42038 25.036 2.751 0 3.4219 28.8839 0.8690 0 6.765067 0 137.9148
Beban Equipment yang Mengenai Secondary Girder pada Main Deck
Eq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Kips 1.79 1.79 3.36 1.19 23.52 23.52 9.24 19.23 5.60 7.09 1.20 2.47 7.84 2.69 5.38 17.92 13.44 4.44 2.24 Total
ft2 4.69 4.69 19.83 10.88 340.00 340.00 224.00 100.00 53.33 92.00 7.07 47.79 66.01 0.00 103.33 108.51 24.66 66.69 20.00
0.797209
1
0.797209
0.663774 1.046957 1.71073
2
0.021766
4.099 0.062 4.161
9
10
1.263366
1.170469 0.092897
Total 0.627025 0.356282 1.436442 0.663774 11.759 0 4.681875 8.158 3.202 3.071 0 0.998955 3.987108 0 0 0 4.77436 2.641374 0.812 47.170
Beban Equipment yang Mengenai Main Girder pada Cellar Deck
Eq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total
kips 15.68 20.16 1.79 1.79 36.77 36.77 44.80 7.84 5.04 6.72 58.24 2.24 92.00 12.00 1.20
ft2 7.87 198.00 5.06 5.06 15.90 15.90 77.58 10.83 624.00 126.00 100.00 24.00 211.75 45.00 7.87
MG 1 0.000
Cellar Deck
No Deskripsi Beban
Total 158.673
Beban Equipment yang Mengenai Main Girder pada Main Deck
Eq 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
kips 1.79 1.79 3.36 1.19 23.52 23.52 9.24 19.23 5.60 7.09 1.20 2.47 7.84 2.69 5.38 17.92 13.44 4.44 2.24 Total
4.69 4.69 19.83 10.88 340.00 340.00 224.00 100.00 53.33 92.00 7.07 47.79 66.01 0.00 24.66 66.69 20.00
ft2
MG 1 0.663774 1.046957 1.71073
Total 0 0 1.037647 0.663774 1.215431 0 1.170469 2.462978 0 0.998031 0 0.813471 1.834412 0 0 0 0 1.046957 0.7 11.94317
Main Deck
No Deskripsi Beban
Total 59.113
MAIN DECK SCANTLINGS (Gratings)
a. Deck Flooring
S = 0.113426
h = 0.8249579113843 in
Dari tabel tebal pelat didapatkan tebal pelat yang mendekati adalah = 7/8 In
Berat pelat tiap ft2 = 36.78 psf = -0.00026 ksi
Decimal Nominal Thickness, In
1/8 0.125
3/16 0.1875
1/4 0.25
5/16 0.3125
3/8 0.375
7/16 0.4375
1/2 0.5
9/16 0.5625
5/8 0.625
3/4 0.75
7/8 0.875
1 1
CELLAR DECK SCANTLINGS (Gratings)
a. Deck Flooring
S = 0.104919
ℎ= √(6𝑆/𝑏)
h = 0.793419 in
Dari tabel tebal pelat didapatkan tebal pelat yang mendekati adalah = 3/4 In
Berat pelat tiap ft2 = 31.68 psf = 0.00022 ksi
Decimal Nominal Thickness, In
1/8 0.125
3/16 0.1875
1/4 0.25
5/16 0.3125
3/8 0.375
7/16 0.4375
1/2 0.5
9/16 0.5625
5/8 0.625
3/4 0.75
7/8 0.875
1 1
PERHITUNGAN AREA HELIDECK
𝑥= √( 〖 25.3 〗 ^2/2)
x = 17.8898 ft
x=a=b = 18 ft
HELIDECK DECK SCANTLINGS (Gratings)
a. Deck Flooring
S = 0.00121
ℎ= √(6𝑆/𝑏)
h = 0.085203 In
Dari tabel tebal pelat didapatkan tebal pelat yang mendekati adalah = 1/8 In
Berat pelat tiap ft2 = 6.16 psf = 4.277778E-05 ksi
(Sumber : API RP 2L-1996 (2006)
3
Smin = 60.25137 in
S = -464.8701 in3
S = 104.53695183 In3
𝜎_𝛼
S = -799.1398694 in3
S = 2.309144 In3
S = 8.766255 In3
e. menentukan profil beam
Selected Beam Profile : AISC Manual 13th Edition. Table 1-1 W
W 8 x 15 Shapes
2nd Level 68
7 3 Level Height (-z)
rd
30 38 -52
Mudline
10 Water Depth 90 0 -90
Elevation
26.1
Main
27 Deck
(Top
of Steel
Plate)
29.9
30 Subcellar
Deck
(Top
of Steel
Plate)
110.5
MAIN DECK - MATERIAL TAKE OFF
EQUIPMENT
Pressure Load Linear Weight Area Weight
No. Description
(psf) (lb/ft) (ft )
2
(kips)
1 Battery box 1 1.79
2 Battery box 2 1.79
3 Air compressor package 3.36
4 Load break switch 1.19
5 Container room-1 23.52
6 Container room-2 0.00
7 Process control room 9.24
8 Transformer 19.23
9 Instrument storage 5.60
10 Fresh water tank 7.09
11 Air receiver 0.00
12 Ansul drum chemical skid 2.47
13 Mechanical storage 7.84
14 Life capsule 0.00
15 Communication microwave 0.00
16 Communication tower 0.00
17 Fuel tank 13.44
18 Power instrument storage 4.44
19 Toilet 2.24
20 Flare bridge 0.00
BLANKET LOAD
21 Live Load 100 2800 280.00
22 Piping Load 100 2800 280.00
23 Plate Self-Weight 36.78 2800 102.98
EQUIPMENT
Pressure Load Linear Weight Length Weight
No. Description
(psf) (lb/ft) (ft) (kips)
24 SG1 40 50.00 2.00
25 SG2 40 50.00 2.00
26 SG3 40 50.00 2.00
27 SG4 40 50.00 2.00
28 SG5 40 50.00 2.00
29 SG6 40 50.00 2.00
30 SG7 40 50.00 2.00
31 SG8 40 50.00 2.00
32 SG9 40 50.00 2.00
33 SG10 40 50.00 2.00
34 SG11 40 50.00 2.00
35 SG12 40 50.00 2.00
36 SG13 40 50.00 2.00
37 SG14 40 50.00 2.00
38 SG15 40 50.00 2.00
BLANKET LOAD
39 MG1 192 50 9.60
40 MG2 192 56 10.75
41 MG3 192 50 9.60
42 MG4 192 56 10.75
SUM 836.94
RIAL TAKE OFF
NT
Coordinate from center point Moment to Deck CG (kips.ft)
No.
x y z Wx Wy Wz
-2.46 -9.46 0.88 -4.40 -16.93 1.57 1
-4.54 -9.46 0.88 -8.13 -16.93 1.57 2
14.00 -18.00 3.00 47.04 -60.48 10.08 3
-21.00 -9.33 3.21 -24.99 -11.10 3.82 4
6.20 -6.75 10.00 145.71 -158.76 235.20 5
0.00 0.00 0.00 0.00 0.00 0.00 6
19.25 -6.28 6.00 177.87 -58.00 55.44 7
-1.92 18.00 4.00 -36.94 346.14 76.92 8
-12.25 -6.69 3.25 -68.60 -37.48 18.20 9
-5.56 -18.00 5.00 -39.45 -127.67 35.47 10
0.00 0.00 0.00 0.00 0.00 0.00 11
21.00 7.56 2.21 51.91 18.69 5.46 12
10.50 15.89 4.38 82.32 124.55 34.30 13
0.00 0.00 0.00 0.00 0.00 0.00 14
0.00 0.00 0.00 0.00 0.00 0.00 15
0.00 0.00 0.00 0.00 0.00 0.00
-14.00 1.29 2.29 -188.16 17.31 30.80 16
-21.00 -1.80 4.50 -93.30 -7.98 19.99 17
-14.00 -18.00 4.00 -31.36 -40.32 8.96 18
0.00 0.00 0.00 0.00 0.00 0.00
OAD
0 0 0 0.00 0.00 0.00
No.
0 0 0 0.00 0.00 0.00
0 0 0 0.00 0.00 0.00 19
20
NT 21
Coordinate from COG Moment to Deck CG (kips.ft) 22
x y z Wx Wy Wz 23
-24.50 0.00 0.00 -49.00 0.00 0.00 24
-21.00 0.00 0.00 -42.00 0.00 0.00 25
-17.50 0.00 0.00 -35.00 0.00 0.00 26
-14.00 0.00 0.00 -28.00 0.00 0.00 27
-10.50 0.00 0.00 -21.00 0.00 0.00 28
-7.00 0.00 0.00 -14.00 0.00 0.00 29
-3.50 0.00 0.00 -7.00 0.00 0.00 30
0.00 0.00 0.00 0.00 0.00 0.00 31
3.50 0.00 0.00 7.00 0.00 0.00 32
7.00 0.00 0.00 14.00 0.00 0.00 33
10.50 0.00 0.00 21.00 0.00 0.00
14.00 0.00 0.00 0.00 0.00 0.00 29
17.50 0.00 0.00 0.00 0.00 0.00 30
21.00 0.00 0.00 42.00 0.00 0.00 31
24.50 0.00 0.00 49.00 0.00 0.00 32
OAD
-21 0 0.00 -201.60 0.00 0.00
0 18 0.00 0.00 193.54 0.00
21 0 0.00 201.60 0.00 0.00
0 -18 0.00 0.00 -193.54 0.00
SUM -53.49 -28.96 537.77
COG -0.064 -0.035 0.643
CELLAR DECK - MATERIAL TAKE OFF
EQUIPMENT
Pressure Load Linear Weight Area Weight Coordinate from center point
Description
(psf) (lb/ft) (ft )
2
(kips) x y
Gas Cooler 15.68 0.00 13.30
Emergency generator 20.16 21.00 3.48
Battery box 1 1.79 -15.90 18.00
Battery box 2 1.79 -13.15 18.00
Vertical separators 1 36.77 -3.50 8.29
Vertical separators 1 36.77 1.50 8.29
Maintenance building 44.80 -11.84 -5.56
Switch gear 7.84 -2.42 18.00
Switch gear building 0.00 0.00 0.00
Switch gear building 6.72 8.46 19.86
Diesel fuel tank 58.24 -1.72 -14.79
Toilet 2.24 10.50 -18.00
Transformer-1 0.00 0.00 0.00
Transformer-2 12.00 11.50 -7.17
Vertical air receiver 0.00 0.00 0.00
BLANKET LOAD
Live Load 110 2800 308.00 0 0
Piping Load 75 2800 210.00 0 0
Plate Self-Weight 31.68 2800 88.70 0 0
EQUIPMENT
Pressure Load Linear Weight Length Weight Coordinate from COG
Description
(psf) (lb/ft) (ft) (kips) x y
SG1 55 50.00 2.75 -24.50 0.00
SG2 55 50.00 2.75 -21.00 0.00
SG3 55 50.00 2.75 -17.50 0.00
SG4 55 50.00 2.75 -14.00 0.00
SG5 55 50.00 2.75 -10.50 0.00
SG6 55 50.00 2.75 -7.00 0.00
SG7 55 50.00 2.75 -3.50 0.00
SG8 55 50.00 2.75 0.00 0.00
SG9 55 50.00 2.75 3.50 0.00
SG10 55 50.00 2.75 7.00 0.00
SG11 55 50.00 2.75 10.50 0.00
SG12 55 50.00 2.75 14.00 0.00
SG13 55 50.00 2.75 17.50 0.00
SG14 55 50.00 2.75 21.00 0.00
SG15 55 50.00 2.75 24.50 0.00
BLANKET LOAD
MG1 261 50 13.05 -21 0
MG2 261 56 14.62 0 18
MG3 261 50 13.05 21 0
MG4 261 56 14.62 0 -18
SUM 948.09
OFF HELI DE
EQUIPMENT
Pressure Load Linear Weight Area Weight Coordinate from center point Moment to Deck CG (k
(psf) (lb/ft) (ft )
2
(kips) x y z Wx
1.67 -21 18 0 -35.07
BLANKET LOAD
40 324 13.0 -21 18 0 -272.16
6.16 324 2.0 -21 18 0 -272.16
EQUIPMENT
Pressure Load Linear Weight Length Weight Coordinate from COG Moment to Deck CG (k
(psf) (lb/ft) (ft) (kips) x y z Wx
13 18.00 0.23 -30.00 18.00 35.00 -7.02
13 18.00 0.23 -27.00 18.00 35.00 -6.32
13 18.00 0.23 -24.00 18.00 35.00 -5.62
13 18.00 0.23 -21.00 18.00 35.00 -4.91
13 18.00 0.23 -18.00 18.00 35.00 -4.21
13 18.00 0.23 -15.00 18.00 35.00 -3.51
13 18.00 0.23 -12.00 18.00 35.00 -2.81
BLANKET LOAD
15 18 0.27 -30 18 35.00 -8.10
15 18 0.27 -12 18 35.00 -3.24
15 18 0.27 -21 27 35.00 -5.67
233.28 0
233.28 0
4.86 9.45
4.86 9.45
7.29 9.45
543.11 85.68
0.649 0.102
MATERIAL TAKE OFF SUMMARY
Wy (kips-ft) Wz (kips-ft)
The deck supported by single deck leg. This deck leg placed right at the COG
-28.96 537.77 must support all the weight.
-10.66 -8560.27
12.38 1.95
-27.24 -8020.55 Total Weight (W) =
Yo Yo Xo =
COG
-0.02 -4.45 Yo =
So,
DL4 =
Assumptions
a. σy =
E =
b.
Concentric Load, no bending stress occurred, only axial c
c. Assumed as portal frame with one end pinned and the othe
AISC Specification 2005].
Design Steps
1
Guess the pre-eliminary Outside Diameter (OD) and Thick
of Gyration (r), and Sectional Modulus (S). OD/t should ha
good practice. [El-Reedy, 2014 Page 94; ISO 19902, 2007
OD/t =
OD =
t =
ID =
A =
05) r =
S =
2
Determine the Buckling Factor (k) and Length of Unbraced
in pre-eliminary design. While ISO 19902 recommended th
Alignment Chart (Figure C-C2.2) for d, rotation free and tra
1; ISO 19902, 2007 Page 100; AISC ASD, 2005 Page 240
Determine the Buckling Factor (k) and Length of Unbraced
in pre-eliminary design. While ISO 19902 recommended th
Alignment Chart (Figure C-C2.2) for d, rotation free and tra
1; ISO 19902, 2007 Page 100; AISC ASD, 2005 Page 240
k =
L =
Sr =
3
Calculate the Local Buckling (fxe) for Axial Compression. [IS
114]
Cx =
E =
fxe =
fy =
Therefore, the fxe is valid because:
0.041379 ≤
4
Calculate the Column Buckling (fc) for Axial Compression.
Page 114]
𝒇_𝒄=(𝟏−𝟎.𝟐𝟕𝟖𝝀^𝟐)𝒇_𝒚
𝒄
λ =
fc =
5
Determine the stress (σc) caused by the concentric load of
leg. (σc = axial compressive stress due to forces from facto
P =
σc =
𝝈_𝒄≤𝒇_𝒄
/𝜸_(𝑹,𝒄)
σc ≤
0.276759 ≤
7
ISO 19902 required that the sum of the ratio of actual load
tubular members subjected to combined axial compression
the following condition at all cross-sections along their leng
γR,cσc/fyc =
DECK LEG - HELI DECK
k leg placed right at the COG of the heli deck. So it can be assumed that the deck leg
a =
b =
c =
19.07 kips d =
0.0 ft
0.0 ft a/a =
a/b =
a/c =
19.07 kips a/d =
05), Chakrabarti (2005) and checked using ISO 19902 (2007) for Column
Design Total Weight
COG
h one end pinned and the other rotation-fixed K=1.0 [case (d) Table C-C2.2
side Diameter (OD) and Thickness (t). Then calculate its Net Area (A), Radius
Modulus (S). OD/t should have the value between 19 to 60 or less than 60 for
14 Page 94; ISO 19902, 2007; Chakrabarti, 2005 Page 330 Vol 1]
40 OK!
30 in (Outside Diameter)
3/4 in (Wall Thickness)
28 1/2 in (Inside Diameter)
68 8/9 in2 (Net Sectional Wall Area)
10 1/3 in (Radius of Gyration)
491.6918 in3 (Sectional Modulus)
1.5
108 in 𝑺_𝒓=𝒌𝑳/ Crane
𝒓
15.66 Heli DL4
(fxe) for Axial Compression. [ISO 19902, 2007 Page 88; El-Reedy, 2014 Page
ng (fc) for Axial Compression. [ISO 19902, 2007 Page 88; El-Reedy, 2014
Assumptions
a.
𝝀=𝑺_𝒓/𝝅 b.
√(𝒇_𝒚𝒄/𝑬)
c.
0.175628
35.69 ksi
Design Steps
used by the concentric load of deck (DL) as axial compressive stress on deck 1
stress due to forces from factored actions) [ISO 19902, 2007 Page 87]
r first guess the pre-eliminary OD and t, we need to make sure that tubular
compressive forces shall be designed to satisfy the following condition: [ISO
fc/γR,c
30.24687 OK! 2
sum of the ratio of actual load/allowable load should be less than 1 where
o combined axial compression and bending forces shall be designed to satisfy
cross-sections along their length: [ISO 19902, 2007 Page 95]
3
0.009072 ≤ 1.0 OK!
𝒇_𝒄=(𝟏−𝟎.𝟐𝟕𝟖𝝀^𝟐
𝒄
5
7
DECK LEG - MAIN DECK
27.52 ft
27.79 ft DL3 DL3 DL4
27.8 ft
c c
27.53 ft
1
0.990284 e e
b
0.989928 a
0.999637
W = 837 kips
Xo = -0.06 ft
Yo = -0.03 ft
DL2 x b = DL1 x a
DL2 = (a/b) x DL1
DL2 = 0.990284 x DL1
DL3 x c = DL1 x a
DL3 = (a/c) x DL1
DL3 = 0.989928 x DL1
DL4 x d = DL1 x a
DL4 = (a/d) x DL1
DL4 = 0.999637 x DL1
C WSD (Manual and Specificaton) (2005), Chakrabarti (2005) and checked using ISO 19902 (2007) for Column
Design
ssumptions
σy = 36 ksi Use Steel with,
E = 29000 ksi (ASTM A36)
Assumed as portal frame with one end pinned and the other rotation-fixed K=1.0 [case (d) Table C-C2.2
AISC Specification 2005].
esign Steps
Guess the pre-eliminary Outside Diameter (OD) and Thickness (t). Then calculate its Net Area (A), Radius
of Gyration (r), and Sectional Modulus (S). OD/t should have the value between 19 to 60 or less than 60 for
good practice. (El-Reedy, 2014 Page 94; ISO 19902, 2007; Chakrabarti, 2005 Page 330 Vol 1)
OD/t = 40 OK!
OD = 30 in (Outside Diameter)
t = 0.75 in (Wall Thickness)
ID = 28.5 in (Inside Diameter)
A = 68.91869 in2 (Net Sectional Wall Area)
r = 10.34484 in (Radius of Gyration)
S = 491.6918 in3 (Sectional Modulus)
Determine the Buckling Factor (k) and Length of Unbraced Member (L). Chakrabarti recommended k = 1.5
in pre-eliminary design. While ISO 19902 recommended the use of k = 1 if the leg is braced and Length
Alignment Chart (Figure C-C2.2) for d, rotation free and translation fixed. [Chakrabarti, 2005 Page 312 Vol.
1; ISO 19902, 2007 Page 100; AISC ASD, 2005 Page 240 Commen. C]
For simplification, use k = 1.5 as recommended by Chakrabarti (2005) though the theoritical k
value is 1 as shown in Table C-C2.2 AISC ASD (2005). Then Calculate the effective slenderness
ratio (Sr).
k = 1.5
L = 324 in 𝑺_𝒓=𝒌𝑳/
𝒓
Sr = 46.98
Calculate the Local Buckling (fxe) for Axial Compression. [ISO 19902, 2007 Page 88; El-Reedy, 2014 Page
114]
Calculate the Column Buckling (fc) for Axial Compression. [ISO 19902, 2007 Page 88; El-Reedy, 2014
Page 114]
𝒇_𝒄=(𝟏−𝟎.𝟐𝟕𝟖𝝀^𝟐)𝒇_𝒚 𝝀=𝑺_𝒓/𝝅
𝒄 √(𝒇_𝒚𝒄/𝑬)
λ = 0.526884
fc = 33.22 ksi
Determine the stress (σc) caused by the concentric load of deck (DL) as axial compressive stress on deck
leg. (σc = axial compressive stress due to forces from factored actions) [ISO 19902, 2007 Page 87]
To check the validation of our first guess the pre-eliminary OD and t, we need to make sure that tubular
members subjected to axial compressive forces shall be designed to satisfy the following condition: [ISO
19902, 2007 Page 87]
𝝈_𝒄≤𝒇_𝒄
/𝜸_(𝑹,𝒄)
σc ≤ fc/γR,c
5.923651 ≤ 28.15399 OK!
ISO 19902 required that the sum of the ratio of actual load/allowable load should be less than 1 where
tubular members subjected to combined axial compression and bending forces shall be designed to satisfy
the following condition at all cross-sections along their length: [ISO 19902, 2007 Page 95]
Since no bending load, (only axial compressive stress), then the 2nd term of equation is 0.
a = 27.42 ft DL2
DL4 b = 27.89 ft DL3 DL3
b
c = 27.9 ft
c
d = 27.43 ft
a/a = 1
e a/b = 0.983148
b
a/c = 0.982796
a/d = 0.999635
DL2 x b = DL1 x a
DL2 = (a/b) x DL1
DL2 = 0.983148 x DL1
DL3 x c = DL1 x a
DL3 = (a/c) x DL1
DL3 = 0.982796 x DL1
DL4 x d = DL1 x a
DL4 = (a/d) x DL1
DL4 = 0.999635 x DL1
MAX = 643.3
007) for Column AISC WSD (Manual and Specificaton) (2005), Chakrabarti (2005) and checked using ISO 19902 (
Design
Assumptions
a. σy = 36 ksi
E = 29000 ksi
b.
Concentric Load, no bending stress occurred, only axial compression stress.
d) Table C-C2.2 c. Assumed as portal frame with one end pinned and the other rotation-fixed K=1.0 [case
AISC Specification 2005].
Design Steps
1
t Area (A), Radius Guess the pre-eliminary Outside Diameter (OD) and Thickness (t). Then calculate its N
or less than 60 for of Gyration (r), and Sectional Modulus (S). OD/t should have the value between 19 to
30 Vol 1) good practice. (El-Reedy, 2014 Page 94; ISO 19902, 2007; Chakrabarti, 2005 Page
OD/t = 40
OD = 30 in
t = 0.75 in
ID = 28.5 in
l Area) A = 68.91869 in2
n) r = 10.34484 in
s) S = 491.6918 in3
2
ommended k = 1.5 Determine the Buckling Factor (k) and Length of Unbraced Member (L). Chakrabarti re
ced and Length in pre-eliminary design. While ISO 19902 recommended the use of k = 1 if the leg is b
2005 Page 312 Vol. Alignment Chart (Figure C-C2.2) for d, rotation free and translation fixed. [Chakrabart
1; ISO 19902, 2007 Page 100; AISC ASD, 2005 Page 240 Commen. C]
For simplification, use k = 1.5 as recommended by Chakrabarti (2005) though the theo
value is 1 as shown in Table C-C2.2 AISC ASD (2005). Then Calculate the effective sl
ratio (Sr).
k = 1.5
L = 192 in
Sr = 27.84
3
Reedy, 2014 Page Calculate the Local Buckling (fxe) for Axial Compression. [ISO 19902, 2007 Page 88; E
114]
4
l-Reedy, 2014 Calculate the Column Buckling (fc) for Axial Compression. [ISO 19902, 2007 Page 88;
Page 114]
𝒇_𝒄=(𝟏−𝟎.𝟐𝟕𝟖𝝀^𝟐)𝒇_𝒚 𝝀=𝑺_𝒓/𝝅
𝒄 √(𝒇_𝒚𝒄/𝑬)
λ = 0.312228
fc = 35.02 ksi
5
ve stress on deck Determine the stress (σc) caused by the concentric load of deck (DL) as axial compres
7 Page 87] leg. (σc = axial compressive stress due to forces from factored actions) [ISO 19902, 20
ure that tubular 6 To check the validation of our first guess the pre-eliminary OD and t, we need to make
g condition: [ISO members subjected to axial compressive forces shall be designed to satisfy the follow
19902, 2007 Page 87]
𝝈_𝒄≤𝒇_𝒄
/𝜸_(𝑹,𝒄)
σc ≤ fc/γR,c
9.33419 ≤ 29.68166
7
ss than 1 where ISO 19902 required that the sum of the ratio of actual load/allowable load should be
designed to satisfy tubular members subjected to combined axial compression and bending forces shall b
5] the following condition at all cross-sections along their length: [ISO 19902, 2007 Page
. Since no bending load, (only axial compressive stress), then the 2nd term of equation is
a ea e
DL1
a
ment Equilibrium
kips
kips
kips
kips
/O Leg Weight)
kips
kips
kips
kips
kips
ompression stress.
OK!
(Outside Diameter)
(Wall Thickness)
(Inside Diameter)
(Net Sectional Wall Area)
(Radius of Gyration)
(Sectional Modulus)
𝑺_𝒓=𝒌𝑳/
𝒓
𝒇_𝒙𝒆=𝟐𝑪_𝒙 𝑬𝒕/𝑫
𝝈_𝒄=𝑷
/𝑨
OK!
OK!
mmary
t (in)
0.75
0.75
0.75
ea e
PILE DIMENSION
TUGAS RANCANG BESAR II 2018/2019
Design Steps
1. Guess the Initial Pile Dimension and Penetration Depth (h). Pile OD should be equal or
less than Deck Leg and Jacket Leg inside diameter (d) (Chakrabarti, 2005).
OD = 30 in (Outside Diameter)
t = 0.75 in (Thickness)
d = 28.500 in (Inside Diameter)
2. Calculate Ultimate Pile Capacity (Qu). This is the sum of end-bearing capacity (Qp) and skin
friction capacity (Qs) as mentioned in API RP 2A WSD (2000), and used by Chakrabarti (2005)
and Dawson (1983).
3. Calculate the total compressive force of pile (F). This is equal to the sum of pile weight (W)
(minus bouyancy), submerged soil weight (Ws), and maximum force from deck leg (DL).
PILE DIMENSION
TUGAS RANCANG BESAR II 2018/2019
4. API RP 2A WSD (2000) requires the usage of Safety Factor (S.F.). For design environment
condition use S.F. = 1.5, and operating environment condition use S.F. = 2. The allowable pile
capacity (Qa) is equal to ultimate pile capacity (Qu) divided by the safety factor, or the ratio
between ultimate pile capacity and total compressive force should be greater than the safety
factor.
SF = 2 𝑄_𝑎=𝑄_𝑢/ 𝑄_𝑢/F≥S.F.
(S.F.).
Qu = 1415.68 kips
F = 648.10 kips
OD = 30 in D/t 40.00
t = 0.75 in OK!
h = 10.00 ft
JACKET LEGS
TUGAS RANCANG BESAR II 2018/2019
Design Steps
1. Guess the Initial Jacket Leg Diameter (OD) and Thickness (t). Jacket Leg Inside
Diameter (d) sized to accommodate pile.
McClelland (1986) recommended the use of D/t less than 45, Chakrabarti (2005) and
API (2000) recommended the use of D/t less than 60, while Reedy (2014)
recommended the use of D/t between 19 to 60.
ODpile = 30.000 in
As initial guess, Chakrabarti (2005) mentioned that jacket leg inside diameter (d) must be 3
or 4 in larger than pile outside diameter (OD pile). This provide the use of clearance or gap (ξ)
between the pile OD and jacket inside diameter of 1.5 to 2 in.
OD = 36.500 in
t = 0.625 in
d = 35.250 in OK! (not less than dmin)
2. API RP 2A requires an increment in diameter for marine growth. For tubular member
in the splash zone, we should add corrosion allowance to the thickness of the jacket
leg. API RP 2A recommended 1/8 to 3/16 in.
tcor = 0.125 in
t = 0.625 in
t = 0.750 in
L = 30.594 ft
k = 2
r = 1.167 ft
Sr = 52.447 OK!
JACKET BRACES
TUGAS RANCANG BESAR II 2018/2019
Assumptions
Design Steps
𝐿=√((𝑎+(𝑎/𝑆))^2+ℎ^2 ) 𝛼=(𝑎+𝑏)/2
𝑏=𝑎+2(ℎ/𝑆) ℎ
Chakrabarti also recommended that the selected OD for brace must have the
diameter ratio (β = ODbrace/ODjacket) more than 0.3.
(Continued)..
3. Guess OD for brace that satisfies the D/t requirements, and its value is between the OD 70
and OD90. Bramlette and McClelland (1986) recommended the use of D/t less than 45,
Chakrabarti (2005) and API (2000) recommended the use of D/t less than 60, while
Reedy (2014) recommended the use of D/t between 19 to 60.
β 0.425
OK!
4. API RP 2A requires an increment in diameter for marine growth. For tubular member in
the splash zone, we should add corrosion allowance to the thickness of the jacket leg.
API RP 2A recommended 1/8 to 3/16 in. And the slenderness ratio S r should be in
between 70 and 90.
72
SCANTLINGS PROPERTIES SUMMARY
TUGAS RANCANG BESAR II 2018/2019
Plate (Flooring)
ThicknessArea WeightPanel Size
Deck
(in) (psf) (ft2)
Cellar Deck 3/4 31.68 2800
Main Deck 7/8 36.78 2800
Heli Deck 1/8 6.16 324
Secondary Girders
Secondar Linear WeightDepth Web (in) Flange (in) Fillet Radius Area
Deck Shape
y Girder (lb/ft) (in) Thickness Width Thickness (in) (in2)
Cellar SG 1 -
W 24 x 55 55 23.600 0.395 7.010 0.505
Deck SG 17
Main SG 1 -
W 18 x 40 40 17.900 0.315 6.020 0.525
Deck SG 17
Heli SG 1 -
W 4 x 13 13 4.160 0.280 4.060 0.345
Deck SG 7
Main Girders
Linear WeightDepth Web (in) Flange (in) Fillet Area
Main
Deck Shape Thicknes Thicknes Radius
Girder (lb/ft) (in) Width (in) (in2)
s s
Cellar MG 1-
W 30 x 261 397 31.6 0.93 15.2 1.65
Deck MG4
Main MG 1-
W 24 x 192 593 25.5 0.81 13 1.46
Deck MG4
Heli MG 1-
W 8 x 15 279 8.11 0.245 4.02 0.315
Deck MG 3
DECK LEG - SUMMARY
TUGAS RANCANG BESAR II 2018/2019