Precautions for user 2

Instruction of Product 3

Protection function and

Caution in use 4

Touch screen and how to use? 6

Remove Common Faults 8

1
Maintenance of Machine 9

Technical parameters 10

2
8、Technical parameters
Model DJHF-4881E
Power supply 380V/3P/50Hz
Input rated power 15.8Kw
Electric current 31A
Nominal capacity
20KG/HOUR
(30℃RH80%)
Air flow 4000m³/h
Refrigerant R22
Refrigerant charge 2.5kgs per compressor
Cooling capacity 18.7Kw
Suitable temperature 5~38°C
Indoor unit: 250kg
Weight
Outdoor unit: 180kg
Indoor: L1400*W715*H1825
Dimension(mm)
Outdoor: L1350*W900*H820

The products design parameters above are subject to


change without notice.

9、What in the box


1、One Dehumidifier 2、One Instructions For user
3、Feet for outdoor unit 4、Four Copper pipe

10
Hangzhou Shuyi Electric Appliance Co., Ltd.

Address:1st Floor, 7th building no 202 Zhenzhong Road,Sandun

Town .Xihu District, Hangzhou City, China

Tel:86-571-88967981 Fax: 86-571-88952137

Http://www.dehumidifierchina.com
A/C Dehumidifier
DJHF-4881E

Instructions For user

●Thank you for buying Dehumidifier.


●In order to you can use the machine safety and properly,
Please read the instruction carefully before using. After
reading, please keep this instruction safety for the time
you need it.
·Use this machine needs regular cleaning filters, isolation
measures should be taken in the dusty environment.
Otherwise will reduce the life of machine, or cause an
accident.
·Prohibit the use of the method of pulling the power plug as
switch.
·Do not let the power cord is damaged or do any processing.
·When using this machine, you need to separate wiring and
install air switch, and reliable ground.
·Prohibit the fingers or sticks inserted in the outlet.
·Prohibit the transformation, except under the guidance of the
company's technical staff.

2、Instruction of Product

3
6、Remove Common Faults
Failure phenomenon Cause Analysis processing method
1、power cut to restore power
2、Power is not normal to restore the power
The machine is not
3、the power plug is not Put plug into the receptacle
running
plugged in
4、Fuse blowout Replace the fuse
1、Filter Clogged Clean the filter
2、Air inlet and outlet Removal of obstructions
obstacles make good ventilation
Poor dehumidification
3、Windows and doors Close doors and windows
function
is not closed and vents
4、Refrigerant leak Contact with the dealer or
manufacturer
1、Doors and windows Close doors and windows
are Not closed
Long-term operation
2、Indoor whether Close steam source
still can't get "the
there is water vapor Change a room
applicable wet "purpose
source
3、room too large
1、The machine placed Place the machine steady or
Noise abnormal not smooth add cushions
2、Filter Clogged Clean the filter
1、When the failure can not be ruled out and recognized the
need for repair, please contact the supplier or service stations,
do not attempt to disassemble the machine repair.
2、When dehumidifier is running or stopped, you will hear the
sound of refrigeration cycle, which is a normal phenomenon,
not a fault.

8
3、Discharge hot air from outlet is a normal phenomenon.

7、Maintenance of Machine
Before maintenance cut off the power, unplug it from the
electrical outlet.

General maintenance
Body: wipe with a soft cloth. If very dirty, with a little hard, wet
cloth decontamination, or with a soft cloth moistened with a
diluted neutral detergent.

Regular maintenance
Cleaning filter:filters accumulate dust, affect the dehumidifying
effect, or even failure, must be cleaned regularly, at least once
a month cleaning available vacuum cleaner dust removing
filter online. Filter put up (<40 ℃) water for rinsing, dry Refit.

Note:
The filter can not direct sun, roasted, in order to avoid
distortion. Before power on the dehumidifier should be fitted
with filters.

When not in use for a long time:


Unplug the power cord, the power cord closed placed in a dry,
cool place can be. The machine Do horizontally, this will result
in failure or abnormal sound. Maintenance stop action, and
unplug it, do not use wet hands to pull the power.
1、Precautions for user
·Use the machine on flat firm floor. Don't put objects before
Vent for better efficiency.
·Don't use the machine in combustible explosive corrosive or
dusty environment.
·Please keep 100cm space around the machine at least for
ventilation.
·Please use the machine away from heat for less power
consumption.
·The temperature of the machine is suitable for the range of 5
℃ ~ 38 ℃, higher than 38 ℃ environment often leaves the
compressor protector action, stop running automatically (this is
normal), but long-term use will affect the life of the machine.
Below 5 ℃, absolute humidity of the environment is quite low,
unless it is absolutely necessary, do not use.
·When the machine used against a wall, the air inlet from the
wall at least 0.5 meters above the outlet from the wall must be
more than one meter, otherwise it will affect the dehumidifying
effect or cause machine failure.
·Do not exceed 45 degrees inclination the machine in moved
or placed.
·Drainage to correctly handle the assembly of the drain pipe.
·In the low temperature Ordinance, the defrost water will
gradually freezes at the outlet, timing shutdown, until all the ice
melted, and then boot to avoid water overflow to disk from

2
hydrocephalus indoor.

3 ℃, this is a normal phenomenon, please feel free to use.

4、When the room temperature below 10 ℃, the

environment absolute humidity is relatively low, may not

necessarily use the dehumidifier

5、The air inlet and outlet must be at least 20cm away from

the wall spacing, so as not to affect the dehumidifying effect or

cause a malfunction.

  6、Please try to seal work environment, in order to

increase the effect of dehumidifier.

  7、Do not place may come into contact with water or

susceptible to chemical use.

  8、Do not use any relay, extension cord or adapter to

connect the machine.

  9、The unit should not be placed next to the stove, heater

and other equipment will heat, and may be subject to direct

sunlight or wind and rain places.

5
 10、Use should erase the dust from the power line and
tighten the plug, placed in a stable place.
  11、Do not damage or modify the power cord, do not self-
repair, disassemble or modify the machine.
  12、When continuous drainage, please put the drain pipe
for drainage flow.
  13、If problem occurs, please turn off the machine and
unplug the power cord.

5、Touch screen and how to use?

Interface
Press “ENTER” into home interface
6
Press “Run” button into running interface

1. “RH-SET”- To set the RH value you want 1~99%


2. “TEMP-SET”- To set temperature you want 5~60℃
3. Don’t enter “Set” to change any setting if not necessary

7
3、Protection function

1、The dehumidifier automatic defrost protection function:

Defrost, the compressor stops running, automatic defrost when

the evaporator frosting to a certain extent, when the frost

melts, the system automatically power up and running again.

2、Compressor delay start protection function: To 3

minutes after the delay after the compressor is stopped,in

order to start again.

4、Caution in use

1、When it is moved, do not body tilted more than 45 °, to

prevent damage to the compressor.

2、Scope of the temperature of the machine for 5 ℃ ~ 38

℃.

3、When the dehumidifier working, due to the operation of

4
the compressor produce heat, so the room temperature up to