Instruction of Product 3
Caution in use 4
1
Maintenance of Machine 9
Technical parameters 10
2
8、Technical parameters
Model DJHF-4881E
Power supply 380V/3P/50Hz
Input rated power 15.8Kw
Electric current 31A
Nominal capacity
20KG/HOUR
(30℃RH80%)
Air flow 4000m³/h
Refrigerant R22
Refrigerant charge 2.5kgs per compressor
Cooling capacity 18.7Kw
Suitable temperature 5~38°C
Indoor unit: 250kg
Weight
Outdoor unit: 180kg
Indoor: L1400*W715*H1825
Dimension(mm)
Outdoor: L1350*W900*H820
10
Hangzhou Shuyi Electric Appliance Co., Ltd.
Http://www.dehumidifierchina.com
A/C Dehumidifier
DJHF-4881E
2、Instruction of Product
3
6、Remove Common Faults
Failure phenomenon Cause Analysis processing method
1、power cut to restore power
2、Power is not normal to restore the power
The machine is not
3、the power plug is not Put plug into the receptacle
running
plugged in
4、Fuse blowout Replace the fuse
1、Filter Clogged Clean the filter
2、Air inlet and outlet Removal of obstructions
obstacles make good ventilation
Poor dehumidification
3、Windows and doors Close doors and windows
function
is not closed and vents
4、Refrigerant leak Contact with the dealer or
manufacturer
1、Doors and windows Close doors and windows
are Not closed
Long-term operation
2、Indoor whether Close steam source
still can't get "the
there is water vapor Change a room
applicable wet "purpose
source
3、room too large
1、The machine placed Place the machine steady or
Noise abnormal not smooth add cushions
2、Filter Clogged Clean the filter
1、When the failure can not be ruled out and recognized the
need for repair, please contact the supplier or service stations,
do not attempt to disassemble the machine repair.
2、When dehumidifier is running or stopped, you will hear the
sound of refrigeration cycle, which is a normal phenomenon,
not a fault.
8
3、Discharge hot air from outlet is a normal phenomenon.
7、Maintenance of Machine
Before maintenance cut off the power, unplug it from the
electrical outlet.
General maintenance
Body: wipe with a soft cloth. If very dirty, with a little hard, wet
cloth decontamination, or with a soft cloth moistened with a
diluted neutral detergent.
Regular maintenance
Cleaning filter:filters accumulate dust, affect the dehumidifying
effect, or even failure, must be cleaned regularly, at least once
a month cleaning available vacuum cleaner dust removing
filter online. Filter put up (<40 ℃) water for rinsing, dry Refit.
Note:
The filter can not direct sun, roasted, in order to avoid
distortion. Before power on the dehumidifier should be fitted
with filters.
2
hydrocephalus indoor.
5、The air inlet and outlet must be at least 20cm away from
cause a malfunction.
5
10、Use should erase the dust from the power line and
tighten the plug, placed in a stable place.
11、Do not damage or modify the power cord, do not self-
repair, disassemble or modify the machine.
12、When continuous drainage, please put the drain pipe
for drainage flow.
13、If problem occurs, please turn off the machine and
unplug the power cord.
Interface
Press “ENTER” into home interface
6
Press “Run” button into running interface
7
3、Protection function
4、Caution in use
℃.
4
the compressor produce heat, so the room temperature up to