Anybus X-gateway - ControlNet™ Adapter Interface Network Installation Sheet

Product Overview LED Indicators Accessories Checklist


The ControlNet interface can be either top- or bottom-mounted. LED Indication Meaning The following items are required for installation:
Both of these options are illustrated below. GW Status See Gateway Installation Sheet • USB cable (included)
Green Initialized • ControlNet configuration tool (not included)
Top-mounted Interface
Green (flashing) Waiting for initialization • EDS file for ControlNet (see www.anybus.com)
MS
MAC ID x 10 Red Major fault, unrecoverable • ControlNet tap (not included)
NAP Ch. A Ch. B MAC ID x 1 Red (flashing) Minor fault, recoverable • Termination resistor1 (optional, not included)
(X1.3) (X1.1) (X1.2) Power Connector (X3) Off Module not initialized
Red Major fault Installation and Startup Summary
Ch. A and Ch. B
Red (flashing) Node configuration error (Depending on your setup, some steps may not be required.)
Red/green (alternating) Hardware self test 1. Connect the gateway to the network
Off Channel disabled 2. Select an unused MAC ID with the rotary switches
Green Normal operation 3. Attach a termination resistor1 (optional)
Ch. A or Ch. B Green (flashing) Temporary error or not configured 4. Connect a PC to the gateway via USB (optional)
Red (flashing) No other nodes or media fault 5. Power up and configure the gateway
Red/green (alternating) Network configuration error 6. Install the EDS file in the ControlNet configuration tool
Off No connection has been opened
Bottom-mounted Interface MO
Green A connection has been opened
MAC ID x 10
NAP Ch. A Ch. B MAC ID x 1
Top-mounted
(X2.3) (X2.1) (X2.2) 1 If node is installed at the end of the bus

GW Status
MS
Ch. A (X1.1)
Ch. B (X1.2)
MO

(NAP = Network Access Port) GW Status


MS
Ch. A (X2.1)
Ch. B (X2.2)
Technical Support
MAC ID Switches MO Technical support, documentation and software downloads are
Two rotary DIP switches are used to set the MAC address of the available at www.anybus.com.
interface between 1 and 99. USB USB Technical questions regarding the ControlNet fieldbus system should
(X4) (X4) be addressed to ODVA at www.odva.org.
Example:

MAC ID = 42 (4 x 10) + (2 x 1) Bottom-mounted

x10 x1
ODVA™ and ControlNet™ are trademarks of ODVA, Inc.

SP1755, rev. 2.00, Mar 2015 www.anybus.com