Raisecom Technology Co., Ltd.

Datasheet
1-slot or 4-slot Chassis

In small-capacity situation, Raisecom presents and through which the four service modules
its 4-slot chassis RC001-4, 4-slot network in RC002-4 can be network managed.
manageable chassis RC002-4 and single- Fixed in RC001-1 series single-slot chassis,
slot chassis RC001-1 to meet customer Raisecom's modular devices become stand-
requirements of installing and/or managing alone equipments, and can be either placed
on table or mounted on wall or rack with RC001-1-DC Chassis
different service modules, including media
converter, fber optic modem, PDH multiplexer, accessories. The employment of power supply
interface converter, G.SHDSL modem and connector of RC001-1 depends on customer's
CWDM cards, concentratedly on one platform. need. Except for traditional connector for AC
RC001-4 and RC002-4 have identical structure or DC power supply, an option of connector
and dimension.The only difference is that for wide-range power supply is provided.
RC002-4 has an in-built SNMP agent module, RC001-1-AC/WP Chassis

Feature
Slot Number RC001/RC002-4 has 4 slots;
RC001-1 has one slot.
Power Supply AC: 100~240V, 50/60Hz; RC001/RC002-4 Chassis
DC: -72~-36V DC
WP: 100~240V AC or -72~-36V DC (the WP power supply connector
will adapt to the factual power supply automatically)
Power Protection overcurrent protection, short circuit protection
Network management RC002-4 is a chassis with in-built SNMP agent module. The SNMP Specifcation
agent module enables the network managment over service modules in
Dimension RC001/002-4:
RC002-4 and their peer devices.
440x44x266mm (WxHxD)
RC001-1:
158x40x200mm (WxHxD)
Ordering Information Power RC001/002-4: ≤40W
RC001-1-AC 1U, 1-slot chassis, with AC power supply connector Consumption RC001-1: ≤10W
RC001-1-DC 1U, 1-slot chassis, with DC power supply connector Working 0~45 degree Celsius
RC001-1-WP 1U, 1-slot chassis, with WP wide-range power supply connector that adapts Temperature
to the factual power supply (AC or DC) automatically Relative Humidity 5%~95%
RC001-1 Rack- Accessory for installing RC001-1 chassis on 19" rack, two RC001-1 can be Storing -40~70 degree Celsius
Mount Tray placed on one tray. ambience
RC001-1 Rack- Accessory for installing RC001-1 chassis on 19" rack, one RC001-1 uses
Mount Angle two rack-mount angles Compliance
RC001-1 Wall- Accessory for installing RC001-1 chassis on wall, one RC001-1 users two
Mount Angle wall-mount angles Standards UL,CE,FCC, CSA
RC001-4-AC 1U, 4-slot chassis, with AC power supply connector complied with IP30
RC001-4-DC 1U, 4-slot chassis, with DC power supply connector
RC002-4-AC 1U, 4-slot chassis with in-built SNMP management agent and AC power
supply connector
RC002-4-DC 1U, 4-slot chassis with in-built SNMP management agent and DC power
supply connector

Andreas Gerold Michael Litvinko


Tel.: + 49(0) 3946 - 91 99 90 Tel.: + 375 17 259 11 03
Fax: + 49(0) 3946 - 91 99 91 Fax: + 375 17 259 11 18
Bossestasse 9, Mobil: + 49(0) 171 - 74 262 76 Mobil: + 375 297 600 103
06484 Quedlinburg,Deutschland E-mail: andreas.gerold@gersis.eu E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
Raisecom Technology Co., Ltd.
Datasheet
RC001-1D single-slot chassis
RC001-1D is a single-slot chassis designed service, occupies 2 slots in RC002-16 . Fixed
for service modules that take up 2 slots in in RC001-1D, these modular devices become
RC002-16. It is applicable for telecom carrier stand-alone equipments, and can be either
and important enterprise user in the feld of placed on table or mounted on wall or rack with
fnance, electric power, petroleum industry, and accessories. The employment of power supply
etc. To provide high service capacity, some of connector depends on user's need. Except
Raisecom's modular devices, including Ethernet for traditional connector for AC or DC power
to 4/8E1 interface converters, PDH multiplexers supply, an option of connector for wide-range
providing 4/8 E1 channels, and multi-service power supply is provided.
multiplexers providing 4/8/16 plus 1 Ethernet
RC001-1D Front Panel
Feature
Power Supply AC power supply connector for AC power supply
Connector or DC power supply connector for DC power supply Specifcations
or WP power supply connector adapted to the factual power
Dimension 158x64x200mm(WxHxD)
supply (AC or DC) automatically Power Supply AC 100~240V, 50/60Hz
Power Protection overcurrent protection DC -36V~-72V
Slot Number 1 slot, with the width of 2 slot of RC002-16 Power less than or equal to 15W
Consumption
Ordering Information Working -5~55 degree Celsius
RC001-1D-AC Temperature
single-slot chassis, with a connector for AC power supply
Humidity 5%~95%
RC001-1D-DC single-slot chassis, with a connector for DC power supply Storing -40~70 degree Celsius
RC001-1D-WP single-slot chassis, with a connector automatically adapted to Temperature
the factual power supply (AC or DC)
Rack-Mount Tray accessory for fxing RC001-1D on to 19-inch rack Compliance
Rack-Mount Angle accessory for fxing RC001-1D on to 19-inch rack Standards CE and UL
Wall-Mount Angle accessory for mounting RC001-1D on wall

Application

Service Modules in RC001-1D


Ethernet to E1 Interface Converters
RC954-FE(FX)4E1, RC954-2FE4E1-BL,
RC954-2FE8E1-BL
PDH Multiplexer
RC832-120L, RC832-240L(-BL)
Multi-Service PDH Multiplexer
RCMS2802-120LFE(-BL), RCMS2802-
240LFE(-BL), RCMS2802-120LGE(-BL),
RCMS2802-240LGE(-BL)

Andreas Gerold Michael Litvinko


Tel.: + 49(0) 3946 - 91 99 90 Tel.: + 375 17 259 11 03
Fax: + 49(0) 3946 - 91 99 91 Fax: + 375 17 259 11 18
Bossestasse 9, Mobil: + 49(0) 171 - 74 262 76 Mobil: + 375 297 600 103
06484 Quedlinburg,Deutschland E-mail: andreas.gerold@gersis.eu E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
Raisecom Technology Co., Ltd.
Datasheet
RC001-1M single-slot network-manageable chassis
RC001-1M is a single-slot chassis with in-built realizes network management function like
SNMP management module. It is designed for confguration management, diagnostics, loop
telecom carrier and important enterprise user activation, monitoring and fault management.
in the feld of fnance, electric power, petroleum There is one console port, one Ethernet port
industry, and etc. Fixed in RC001-1M, modular and one slot for modular device on the front
media converters, PDH multiplexers, interface panel. The AC and DC power supply connectors
converters, G.SHDSL modems and other on the rear panel of RC001-1M provides users RC001-1M Front Panel
modules designed for 1U slots become stand- with the fexibility of using AC power supply, or
alone and network-manageable equipments. DC power supply or both of them.
The SNMP agent module built in RC001-1M

Feature RC001-1M Rear Panel


Power Supply AC power supply, or DC power supply, or both AC and DC
power supply
Power Protection overcurrent protection, short circuit protection, overheat
protection
Slot Number 1 slot Specifcations
InterfaceType 1 SNMP interface for network management Dimension 260x38x190mm(WxHxD)
1 CONSOLE interface for initial confguration of SNMP Power Supply AC 100~240V,0.35A,50/60Hz
Netwrok network management over the service module in the RC001- DC -48V,0.6A
Management 1M and the device on the opposite side of the communication Power less than or equal to 15W
Consumption
Working 0~45 degree Celsius
Ordering Information Temperature
RC001-1M single-slot chassis, with inbuilt SNMP network management Humidity 5%~95%
agent module, 1 AC and 1 DC power supply connector Storing -40~70 degree Celsius
Temperature

Application Compliance
Standards CE and UL

Service modules working and managed in RC001-1M


RC1~RC6 series media converters
RC8xx series PDH multiplexers providing 1/2/4 E1 channels or 1 DS1 channel or
1 DS3/E3 channel Bossestasse 9,
Multi-service PDH multiplexer RCMS2x01 series and RCMS2802-60GE-BL 06484 Quedlinburg,Deutschland
Andreas Gerold
RC9xx series Ethernet to E1, Ethernet to DS3/E3, Ethernet to V.35, V.35 to E1 Tel.: + 49(0) 3946 - 91 99 90
interface converters Fax: + 49(0) 3946 - 91 99 91
Mobil: + 49(0) 171 - 74 262 76
OPCOM200 series CWDM modular equipments E-mail: andreas.gerold@gersis.eu
RC1102 series G.SHDSL modem Michael Litvinko
Tel.: + 375 17 259 11 03
Fax: + 375 17 259 11 18
Mobil: + 375 297 600 103
E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
Raisecom Technology Co., Ltd.
Preliminary Datasheet
RC001-2M dual-slot network-manageable chassis
RC001-2M is a dual-slot chassis with in-built function like confguration management,
SNMP management module. It is designed for diagnostics, loop activation, monitoring and
telecom carrier and important enterprise user fault management. There is one console port,
in the feld of fnance, electric power, petroleum one Ethernet port and two slots for two units
industry, and etc. Fixed in RC001-2M, modular of individual single-slot width modular device
media converters, PDH multiplexers, interface or one unit of 2-slot width modular device on
converters, G.SHDSL modems and other the front panel. The AC and DC power supply RC001-2M Front Panel
modules that take up 2 slots in RC002-16 connectors on the rear panel of RC001-2M
become stand-alone and network-manageable provides users with the fexibility of using AC
equipments.The SNMP agent module built power supply, or DC power supply or both of
in RC001-2M realizes network management them.

RC001-2M Rear Panel

Feature
Power Supply Single AC power supply, or single DC power supply, or both Specifcations
AC and DC power supply with two individual connectors or a Dimension 320x65x200mm(WxHxD)
auto-sensing connector Power Supply AC 100~240V,0.35A,50/60Hz
Power Protection overcurrent protection, short circuit protection, overheat DC -48V,0.6A
protection Power less than or equal to 15W
Slot Number Consumption
2 slots
Working 0~45 degree Celsius
InterfaceType 1 SNMP interface for network management Temperature
1 CONSOLE interface for initial confguration of SNMP Humidity 5%~95%
Netwrok network management over the service module in the RC001- Storing -40~70 degree Celsius
Management 2M and the device on the opposite side of the communication Temperature

Compliance
Standards CE and UL

Ordering Information
RC001-2M-AC/DC Dual-slot chassis, with in-built SNMP network management
agent module, 1 AC and 1 DC power supply connecters
RC001-2M-WP Dual-slot chassis, with in-built SNMP network management
agent module, 1 AC/DC auto-sensing power supply connecter
RC001-2M-AC Dual-slot chassis, with in-built SNMP network management
agent module, AC power supply
RC001-2M-DC Dual-slot chassis, with in-built SNMP network management
agent module, DC power supply

Andreas Gerold Michael Litvinko


Tel.: + 49(0) 3946 - 91 99 90 Tel.: + 375 17 259 11 03
Fax: + 49(0) 3946 - 91 99 91 Fax: + 375 17 259 11 18
Bossestasse 9, Mobil: + 49(0) 171 - 74 262 76 Mobil: + 375 297 600 103
06484 Quedlinburg,Deutschland E-mail: andreas.gerold@gersis.eu E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
Raisecom Technology Co., Ltd.
Preliminary Datasheet
RC001-2M dual-slot network-manageable chassis

Typical Application

Dual-slot-width service modules working and managed in RC001-2M (02/2008)


RC8xx series PDH multiplexers
RCMS series Multi-service PDH multiplexers
RC9xx series Ethernet over PDH(E1s) inverse multiplexers

One-slot-width service modules working and managed in RC001-2M (02/2008)


RC1xx~RC6xx series media converters
RC8xx series PDH modem and multiplexers
RCMS series Multi-service PDH multiplexers
RC9xx series Ethernet over E1(s), Ethernet over DS3/E3, Ethernet over V.35, V.35 to E1 interface
converters and inverse multiplexers
OPCOM200 series CWDM modular equipments
RC1102 series G.SHDSL modems
Warning: The total power consumption of the 2 one-slot-width service modules working in
RC001-2M must not exceed 12W.

Andreas Gerold Michael Litvinko


Tel.: + 49(0) 3946 - 91 99 90 Tel.: + 375 17 259 11 03
Fax: + 49(0) 3946 - 91 99 91 Fax: + 375 17 259 11 18
Bossestasse 9, Mobil: + 49(0) 171 - 74 262 76 Mobil: + 375 297 600 103
06484 Quedlinburg,Deutschland E-mail: andreas.gerold@gersis.eu E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
Raisecom Technology Co., Ltd.

RC002-16 16-slot Chassis with SNMP Management Datasheet

RC002-16 is a 19" rack-mountable 3U platform unit with no connection to the adjacent cards.
which supports two rear-loading, redundant, This allows each card to support a different
load-sharing, hot-swappable AC or DC power rate, interface or media.
supplies. Up to 16 modular converters can be All cards are hot-wappable and can be replaced
installed in the chassis, providing a CO/POP without interfering with the data transmission of
site solution for connecting up to 16 remote other cards.
users (15 with SNMP function). RC002-16 supports SNMP management with
RC002-16 is manageable access system for NMS1 card inserted. The network management
providing full convergence of the Last Mile software iEMS enables the user to change RC002-16
with a variety of technologies, rates, interfaces the setup confguration, get real-time alerts on
and media. The system supports standard system status, active diagnostics, and receive
technologies G.703/704, G.SHDSL and statistics on system functionality in a graphic
IEEE802.3. Each card in the RC002-16 works in format.
a point-to-point confguration opposite a remote

Feature RC001-NMS1
Slot Number Up to 16 slots for modular converters
Redundant Power Two rear-loading, redundant, load-sharing, hot-swappable AC or DC or one
Supply AC and one DC power supplies
Hot-wappable RC002-16 can operate with single or dual AC or DC power supplies. Specifcation
power supply Each power supply supports a full rack of any combination of cards. Number of slot 16
The redundant power supply can be replaced without affecting system Power supply Two hot-swappable AC or DC
performance power supplies
Flexibility Single chassis for various modular converters with a variety of technologies, Input power AC: 185V-265V, 50/60Hz
rates, interfaces and media supply voltage DC: -36V- -72V
Hot-swappable All cards are hot-swappable and can be replaced without interfering with the Rated Current 20A
modular converters data transmission of other cards
Short Current Yes
Safety Compliance CE and UL Protection
Effcient Heat Optimal structure for effcient heat dissipation Over Current 30A
dissipation Protection
Network The chassis can be managed by Raisecom network management platform Noise ≤100mVp-p
Management Nview iEMS (graphic format), which allowing confguration management,
Port CONSOLE: RJ-45
diagnostics and loop activation, as well as monitoring and fault management
specifcation ETH (for SNMP and Telnet):
Real-time The management software enables the user to change the setup (For NMS1 RJ-45
confguration and confguration, get real-time alerts on system status, activate diagnostics, and network Cascading port: RJ45
monitoring receive statistics on system functionality in a graphic format. management
Ordering Information card)
Indicators PWR: for power supply
RC001-NMS1 Network management master module for RC series modules, installed into PS1-5: PS1 for modules
3U 16-slot chassis PS1-12: PS1 for 1st fan
RC001-NMS2 Network management slave module for RC series modules, installed into 3U PS2-5: PS2 for modules
16-slot chassis PS2-12: PS2 for 2nd fan
RC002-16AC/S 3U, 16-slot chassis with one AC power supply connector Dimension 442x130.5x350mm (WxHxD)
RC002-16AC/D 3U, 16-slot chassis with two AC power supply connector Power ≤80W (at max load)
RC002-16DC/S 3U, 16-slot chassis with one DC power supply connector consumption
RC002-16DC/D 3U, 16-slot chassis with two DC power supply connector Working Temp: 0~50 degree Celsius
RC009-2AC Redundant AC power supply for RC002-16 ambience RH: 5~90% non-condensing
Storage Temp: -40~85 degree Celsius
RC009-2DC Redundant DC power supply for RC002-16
ambience RH: 20~90% non-condensing
Mount Angle 21 Accessory for installing RC002-16 on 21" rack, two angles for one chassis Safety CE marking
Mount Angle 23 Accessory for installing RC002-16 on 23" rack, two angles for one chassis compliance UL
Note: The RC002-16 chassis can be installed on 19" rack directly without any accessory.

Andreas Gerold Michael Litvinko


Tel.: + 49(0) 3946 - 91 99 90 Tel.: + 375 17 259 11 03
Fax: + 49(0) 3946 - 91 99 91 Fax: + 375 17 259 11 18
Bossestasse 9, Mobil: + 49(0) 171 - 74 262 76 Mobil: + 375 297 600 103
06484 Quedlinburg,Deutschland E-mail: andreas.gerold@gersis.eu E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
Raisecom Technology Co., Ltd.
RC002 Cascade
With management agent master
module RC001-NMS1 and
slave module RC001-NMS2
connecting in the manner shown
on the right, four RC002-16
chassis forms a cascade.
At most sixty pairs of
equipments at both local and
remote sites can be managed
through one IP address which
is the IP address of RC001-
NMS1.

Typical Application

Andreas Gerold Michael Litvinko


Tel.: + 49(0) 3946 - 91 99 90 Tel.: + 375 17 259 11 03
Fax: + 49(0) 3946 - 91 99 91 Fax: + 375 17 259 11 18
Bossestasse 9, Mobil: + 49(0) 171 - 74 262 76 Mobil: + 375 297 600 103
06484 Quedlinburg,Deutschland E-mail: andreas.gerold@gersis.eu E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
Raisecom Technology Co., Ltd.
Datasheet
RC004-16 Chassis for PDH FOM Modular Devices

RC004-16 is a 19" rack mountable 10U of other cards. RC004-16 supports SNMP
16-slot chassis for Raisecom modular type network management with RC004-16NMS1
Fiber Optical Modem (4E1, 8E1, 16E1 card inserted in slot 0, and along with the
and 8E1+4ETH) and it has rear-loading, RC004-16NMS2 card cascade can be realized
redundant, load-sharing,hot-swappable AC or up to 4 RC004-16 chassis. The network
DC power supply. Each card in the RC004-16 management software NNM enables users to
works in a point-to-point mode with a remote change the setup confguration, get real-time
unit and so as to provide a CO/POP site alerts on system status, active diagnostics,
solution for Fiber Optical Modem users. All and receive statistics on system functionality
cards are hot-swappable and can be replaced in a graphic format.
without interferring with the data transmission RC004-16 16-slot Chassis
with SNMP Management
Feature
Slot Number Up 16 slots for modular converters
Redundant Power Two rear-loading, redundant, load-sharing, hot-swappable AC or DC or one
Supply AC and one DC power supplies
Hot-wappable RC004-16 can operate with single or dual AC or DC power supplies.
power supply Each power supply supports a full rack of any combination of cards.
The redundant power supply can be replaced without affecting system
performance
Flexibility Single chassis for various modular converters with a variety of technologies, RC004-16NMS1
rates, interfaces and media
Hot-swappable All cards are hot-swappable and can be replaced without interfering with the
Management Agent Module
modular converters data transmission of other cards
High Reliability NEBS Compliant
Safety Compliance CE and UL
Effcient Heat Optimal structure for effcient heat dissipation
dissipation RC004-16NMS2
Ordering Information Management Cascade
Module
RC004-16NMS1 Master agent module for network management, installed in slot 0 of
RC004-16 chassis
RC004-16NMS2 Cascade module for network management, installed in slot 0 of RC004-16
chassis
RC004-16AC 10U, 16-slot chassis with one AC power supply
Specifcation
(can provide redundant power supply) Power supply Two hot-swappable AC or DC
RC004-16DC 10U, 16-slot chassis with one DC power supply power supplies
(can provide redundant power supply) Input power AC: 185V-265V, 50/60Hz
RC007-2AC Redundant power supply for RC004-16 chassis, AC supply voltage DC: -36V- -72V
RC007-2DC Redundant power supply for RC004-16 chassis, DC Short Current Yes
Mount Angle 19 Accessory for installing RC004-16 chassis on 19" center mounted rack Protection
Center Note: RC004-16 chassis can be directly installed on normal front mounted Dimension 436(W)*440(H)*360(D)mm
19" rack and need no additioinal mount angle. Power ≤150W (at max load)
Mount Angle 21 Accessory for installing RC004-16 chassis on 21" center mounted rack consumption
Center Working Temp: 0~50 centigrade
ambience RH: 5~90% non-condensing
Storage Temp: -40~85 centigrade
ambience RH: 20~90% non-condensing
Compliance
Standard UL

Andreas Gerold Michael Litvinko


Tel.: + 49(0) 3946 - 91 99 90 Tel.: + 375 17 259 11 03
Fax: + 49(0) 3946 - 91 99 91 Fax: + 375 17 259 11 18
Bossestasse 9, Mobil: + 49(0) 171 - 74 262 76 Mobil: + 375 297 600 103
06484 Quedlinburg,Deutschland E-mail: andreas.gerold@gersis.eu E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
Raisecom Technology Co., Ltd.
Datasheet
RC006-1 Series single-slot chassis
Raisecom modem pool RC006-12 could modem pool RC006-12 could be deployed in
feed high speed and legacy data service, remote site with single-slot chassis RC006-1
leased line service and backhauling of mobile as well to enable customer to save cost for
BTS and connectivity WiMAX CPE of Metro inventory. Raisecom also offers the single-slot
Ethernet simultaneously. It could hybrid support chassis with SNMP & console ports RC006-1M
for multiple levels PDH products including for single module application in central offce. RC006-1
E1 extension PDH fber optical multiplexer,
PCM multiplexer, Ethernet over PDH Inverse
Multiplexer. All of the module in central offce

RC006-1, RC006-1M RC006-1M

Features
Construction Single-slot, 19 inch, 1Unit high
Specifcation
Power Supply Single AC, or single DC, or AC/DC redundant power supplies Console port RS-232 standard
RC006-1 non-management chassis RJ-45
RC006-1M SNMP interface for management, Console interface for SNMP initial 9600bps
confguration. SNMP port 10/100Mbps
In support of management over service modules in the chassis and FDX/HDX
remote devices Auto-negotiation
In support of online upgrade IEEE802.3x fow control
Auto-MDI/MDIX
Ordering Information Dimensions 430(W)*44.45(H)*266mm(D)
Power Supply 180VAC~260VAC
RC006-1-X single-slot chassis for modules in RC006-12 -36VDC~-72VDC
RC006-1M-X single-slot chassis for modules in RC006-12, SNMP management +12VDC~+36VDC
X indicates the optical port specifcation: Power <5W (non-managable)
AC: 220V/230VAC power supply; Consumption <15W (managable)
DC: -48VDC power supply; Working Temp: 0~50 centigrade
AC/DC: AC and DC redundant power supply ambience RH: 5~90% non-condensing
Safety CE certifcation
compliance
Application
Modules Working & Managed
in RC006-1M
Ethernet to E1 Interface Converter
RC956-FE(X)8E1
PDH Fiber Optic Multiplexer
RC832-120(-BL),RC832-240(-BL)
Multi-Service PDH Multiplexer
RCMS2802-120FE(-BL),RCMS2802-240FE(-
BL),RCMS2812-120FE,RCMS2812-240FE(-
BL),RCMS2812-480FE(-BL)
Voice/Data over E1/Fiber Multiplexer
RC3102,RC3202
Optical Line Protection Card for CWDM system
OPCOM100-OLP-A
RCVS series Video Optical Multiplexer

Andreas Gerold Michael Litvinko


Tel.: + 49(0) 3946 - 91 99 90 Tel.: + 375 17 259 11 03
Fax: + 49(0) 3946 - 91 99 91 Fax: + 375 17 259 11 18
Bossestasse 9, Mobil: + 49(0) 171 - 74 262 76 Mobil: + 375 297 600 103
06484 Quedlinburg,Deutschland E-mail: andreas.gerold@gersis.eu E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
Raisecom Technology Co., Ltd.

RC006-12 12 service slots multi-service modem pool

RC006-12 is a ETSI complied 19" rack- PDH product up to 16E1; PCM multiplexer’
mountable 6U high platform which supports s analog voice and legacy data service for
two front-loading, redundant, load-sharing, enterprise customers; carrier grade multi-
hot-swappable AC or DC power supplies. Up service PDH product with up to 16 E1s
to 12 modular service cards and one network (including 1*V.35) and 1*10/100M Ethernet
management card can be installed in the interface.
chassis, providing a CO/POP site solution for Redundant fber optic links and power supply
connecting up to 12 remote CPE. could guarantee the maximum networking
RC006-12 multi-service modem pool feeds uptime. Switching over time from primary
simultaneously high speed and legacy data fber link to secondary is less than 50ms. This
service, analog voice service, leased line platform could supply SNMP management,
service and backhauling of Mobile BTS and TELNET, and local craft terminal management
connectivity WiMAX CPE to Metro Ethernet. through RS232 interface. Full range of
It could hybrid support for multiple level PDH management makes carrier to easily operate RC006-12 12 service slots
products such as: cost effective E1 extension and monitor local and remote device anywhere. multi-service modem pool

Feature Specifcation
Slot Number 15 slots, 12 slots for service cards, 2 slots for power supply modules and 1
Number of slot 15
slot for network management card
12 slots for service cards
Redundant Power Two front-loading, redundant, load-sharing, hot-swappable dual AC or dual 2 slots for power supply
Supply DC or one AC and one DC power supply modules
Hot-wappable RC006-12 can operate with single or dual AC or DC power supplies. 1 slot for network
power supply Each power supply supports a full rack of any combination of cards. management card
The redundant power supply can be replaced without affecting system Power supply Two hot-swappable AC or DC
performance power supplies
Flexibility Single chassis for various modular cards with a variety of technologies, Input power AC: 85V-265V, 50/60Hz
rates, interfaces and media, unifed SNMP management for all the modules supply voltage DC: -36V- -72V
Hot-swappable All cards are hot-swappable and can be replaced without interfering with the Rated Current 20A
modular converters data transmission of other cards
Short Current Yes
Safety Compliance CE and UL Protection
Effcient Heat Optimal structure for effcient heat dissipation Over Current Yes
dissipation Protection
Network The chassis can be managed by Raisecom network management platform Noise ≤100mVp-p
Management Nview iEMS (GUI), which allowing confguration management, diagnostics
Port CONSOLE: RJ-45
and loop activation, as well as monitoring and fault management
specifcation ETH (for SNMP and Telnet):
Real-time The management software enables the user to change the setup (For NMS1 RJ-45
confguration and confguration, get real-time alerts on system status, activate diagnostics, and network
monitoring receive statistics on system functionality in a graphic format. management
card)
Net Weight 4.6kg (with two power
supplies)
Ordering Information Dimension 442(W)*248(H)*267(D)mm
RC006-12-NMS Network management module for RC006-12 chassis Power ≤300W (at max load)
consumption
RC006-12AC/S 6U, 12 service slots chassis with one 115V or 230V AC power supply
Working Temp: -5~50 centigrade
RC006-12AC/D 6U, 12 service slots chassis with two 115V or 230V AC power supplies
ambience RH: 5~90% non-condensing
RC006-12DC/S 6U, 12 service slots chassis with one -48V DC power supply
Storage Temp: -40~85 centigrade
RC006-12DC/D 6U, 12 service slots chassis with two -48V DC power supplies ambience RH: 20~90% non-condensing

Andreas Gerold Michael Litvinko


Tel.: + 49(0) 3946 - 91 99 90 Tel.: + 375 17 259 11 03
Fax: + 49(0) 3946 - 91 99 91 Fax: + 375 17 259 11 18
Bossestasse 9, Mobil: + 49(0) 171 - 74 262 76 Mobil: + 375 297 600 103
06484 Quedlinburg,Deutschland E-mail: andreas.gerold@gersis.eu E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com
Raisecom Technology Co., Ltd.

Typical Applicatioin

Andreas Gerold Michael Litvinko


Tel.: + 49(0) 3946 - 91 99 90 Tel.: + 375 17 259 11 03
Fax: + 49(0) 3946 - 91 99 91 Fax: + 375 17 259 11 18
Bossestasse 9, Mobil: + 49(0) 171 - 74 262 76 Mobil: + 375 297 600 103
06484 Quedlinburg,Deutschland E-mail: andreas.gerold@gersis.eu E-mail: mikhail.litvinko@gersis.eu
www.sis-group.com

You might also like