Professional Documents
Culture Documents
Shark 200 Data Logging Meter With IO Brochure - E149702
Shark 200 Data Logging Meter With IO Brochure - E149702
Shark 200
®
Meter/Transducer
• Simple Multifunction Meter: V-Switch™ Key 1 • Power Quality Recording up to 512 Samples/Cycle
• Historical Data Logging: V-Switch™ Key 2 • Embedded Web Server - with Smartphone and Tablet
Support
• Additional Memory for Extensive Data Logging:
V-Switch™ Keys 5 and 6 • Dual Ethernet Ports Compatible with Modbus,
DNP3 over TCP/IP, and IEC 61850 Protocols!
• Advanced Power Quality Waveform Recorder:
V-Switch™ Keys 5 and 6 • Supports Email on Alarm and Periodic Email
Notification of Meter Status and Readings
• Ethernet Port Offers Data Push to Cloud Servers
• Enhanced Security with IP Whitelisting
High Performance Waveform Advanced Features Summary
Recording
• High Performance Waveform Recorder
Basic Features Summary • Up to 4 Megabytes Flash for Historical Data Logging and PQ
Recording
• 0.2% Class Revenue Certifiable Energy and Demand Metering • Extremely Configurable Field Upgradable I/O
• 100BaseT Ethernet – Rapid Response™ Technology
• Meets ANSI C12.20 0.2 CL and IEC 62053-22 0.2S Accuracy
Standard • V-Switch™ Technology
• High Precision Frequency Measurement for Frequency Control
• Multifunction Measurement
• 3 Line .56" LED display and % of Load Bar for Analog Perception Applications
2 MB Data Logging P P P
3 MB Data Logging P Advanced Revenue Energy Metering Capabilites
4 MB Data Logging P P P P
Harmonic Analysis P P P P
• Line Frequency Time Sync • Historical Load Profiling
TLC and CT/PT Compensation P P P P P P
Limit and Control Functions P P P
• Traceable Watt-hour Test • Transformer and Line Loss
64 Samples per Cycle Waveform Recorder P
Pulse Compensation
512 Samples per Cycle Waveform Recorder P • Utility Block and Rolling • CT/PT Compensation
Average Demand
2
Extensive Data Logging Capability System Events Log
I/O Change Log Limit Alarms and Control Capability (V4 and Higher)
• Provides a Time Stamped Log of Any Relay Output • Any Measured Parameter • Based on % of Full Scale
• Provides a Time Stamped Log of Input Status Changes • Up to 16 Limits Settings
• 2048 Events Available • Voltage/Current Imbalance
Samples Pre Post Max Max Harmonic Recording to the 40th Order
per Event Event Waveform Waveform
Cycle Cycles Cycles per Event per Event
16 32 96 256 85
The Shark® 200 meter provides
V5 32 16 48 128 85
advanced harmonic analysis to the
64 8 24 64 85 40th order for each voltage and current
128 4 12 32 170 channel, in real time. Using the stored
V6 256 2 6 16 170 waveforms, harmonic analysis is
512 1 3 8 170 available to the 255th order.
Note: Sampling rate based on 60 Hz systems. For 50 Hz systems, multiply by 1.2.
3
Standard Communication
Capability
The Shark® 200 meter provides two independent communication ports • KYZ Pulse - In addition to the RS485 port, the meter also
with advanced features. includes Pulse Outputs mapped to absolute energy.
Rear Mounted Serial Port with KYZ Pulse Front Mounted IrDA Communication
• RS485 - This port allows RS485 communication using Mod- Uniquely, the Shark® 200 meter also has an optical IrDA port, allowing
bus or DNP3 protocols. Baud rates are from 1200 to 57600. you to program it with an IrDA-enabled laptop.
The Shark® 200 meter offers unequaled I/O PO1S: Four Pulse Outputs / Four Status Inputs
expandability. Using the two universal option slots, the unit can be
• Programmable to any energy parameter and pulse
easily configured to accept new I/O cards, even after installation. The unit
value.
auto-detects installed I/O option cards. Up to 2 cards of any type can be
used per meter. • Form A: Normally open contacts.
• Also used for End of Interval pulse.
INP100S: 100BaseT Ethernet Capability
• NTP time server for high accuracy network time RO1S: Two Relay Outputs / Two Status Inputs*
synchronization.
• 250 V AC / 30 V DC - 0.25 A relays, form C.
• 12 simultaneous Modbus TCP/IP connections; 5
• Trigger on user set alarms.
simultaneous DNP over TCP/IP connections.
• Set delays and reset delays.
• Supports data push to Cloud servers.
(INP100S)
HTTP
Modbus TCP/IP or IEC 61850 Protocol
Simultaneous Connections
to Multiple Software Systems
INP100S - Web Server, Modbus, DNP, and Email • Dual Ethernet Port Capable
• Simultaneous Modbus, DNP over Ethernet, and IEC 61850
• Web Server with Configurable HMI
• Smartphone Compatible Both INP100S and INP300S offer enhanced security through the Exclusive
• 12 Connections Modbus TCP/IP Client feature, which provides secure communication for a Whitelisted IP/
MAC address, to protect from unauthorized programming.
• 5 Connections DNP over TCP/IP
• Data Push of Meter Readings to Cloud Servers
• Send Email on Alarm or Periodic Email Notification of Meter
Status and Readings
4.85” 4.65" 4.76"
[12.32cm] [11.81cm] 12.10cm
4.10" 4.14” 0.62”
INP300S - Web Server, Modbus, DNP, and IEC 61850 [10.41cm] 10.52cm 1.61cm
9.04cm
5.02”
3.56”
4.85”
Ic Ib Ia
• 5 Modbus Connections LO LO LO
• 5 MMS Clients
Embedded Web Server with Smartphone Support
• Web Server for Status and Configuration 3.25” 0.91" 3.25”
[8.26cm] 2.31cm 8.26cm
4 X 0.2”
The unit mounts directly in an ANSI C39.1 (4” round form) or an IEC 92
mm DIN square form. This is perfect for new installations and for existing 4.0”
panels. In new installations, simply use DIN or ANSI punches. For existing
[9.04cm]
9.20cm
3.56”
panels, pull out old analog meters and replace them with the Shark® 200
meter. The meter uses standard voltage and current inputs so that CT and
PT wiring does not need to be replaced. American European
(One meter fits both standards)
This transducer version of the Shark® 200 meter does not include a
display. The unit mounts directly to a DIN rail and provides an RS485 Easy DIN Rail
Mounting
Modbus or Level 2 DNP3 output and the expandable I/O.
5
Typical Substation Solutions
The Shark® 200 meter allows you to log substation data over time with
regard to electrical usage, demand, voltage, current, PF, and many other
parameters. This enables a complete analysis of the power system over
time.
The Shark® 200 meter's advanced output capability brings back data
using many different communication media, such as RS485, Ethernet, and
analog outputs. This ensures that one meter can be used for almost every
substation application, no matter what communication infrastructure is
needed.
6
Dimensional Drawings
[12.75cm]
[9.04cm]
[12.32cm]
HI HI HI
5.02”
3.56”
4.85”
Ic Ib Ia
LO LO LO
Wiring Diagrams
LINE LINE
N A B C A B C
FUSES FUSES
3 x 0.1A 3 x 0.1A
N A B C A B C
LOAD LOAD
LINE LINE
N A B C A B C
FUSES FUSES
3 x 0.1A 2 x 0.1A
Earth Ground
Earth Ground
N A B C A B C
LOAD LOAD
7
Specifications
Voltage Inputs: Isolation: Standard Meter Accuracy:
Communication Format:
• (20-576) Volts Line To Neutral, • All Inputs and Outputs are Galvani- • See Page 2
(0-721) Volts Line to Line cally Isolated to 2500 Volts • 2 Com Ports (Back and Faceplate)
• Note: For 2.5 element programmed units, de-
• Universal Voltage Input Environmental Rating: • RS485 Port through Backplate
grade accuracy by an additional 0.5% of reading.
• Input Withstand Capability – Meets IEEE • Storage: (-20 to +70) °C • IrDA through Faceplate
C37.90.1 (Surge Withstand Capability) • Note: For 1A (Class 2) Nominal, degrade
• Operating: (-20 to +70) °C • Com Port Baud Rate: (1200 - 57600)
• Programmable Voltage Range to Any PT ratio accuracy to 0.5% of reading for watts and
• Humidity: to 95% RH Non-Condensing • Com Port Address: 1-247 energy; all other values 2 times rated accuracy.
• Supports: 3 Element WYE, 2.5 Element WYE, • Faceplate Rating: NEMA 12 • 8 Bit, Parity Setting: Odd, Even, None
2 Element Delta, 4 Wire Delta Systems Compliance:
• Mounting Gasket Included • Modbus RTU, ASCII, or DNP3 Protocols
• Input Impedance 1 Mega Ohm/Phase; Burden: • IEC 62053-22 0.2S
0.36 VA/Phase at 600 V; 0.014 VA at 120 Volts • Protection: IP 30 - Meter Front/Back, Optional KYZ Pulse:
DIN Rail Mounting, Optional Plug-in I/O Modules • ANSI C12.20 0.2 CA
• Input Wire Gauge: AWG#12 -26/ • Type Form C Contact
(0.129 -3.31) mm2 Sensing Method:
• On Resistance: 35 Ohms Max • ANSI (IEEE) C37.90.1 Surge Withstand
Current Inputs: • True RMS
• Peak Voltage: 350 V DC • ANSI C62.41 (Burst)
• Class 10: (0.005 to 11) A, 5 A Nominal • Sampling at over 400 Samples/Cycle on all
Channels of Measured Readings Simultaneously • Continuous Load Current: 120 mA • EN61000-6-2 – Immunity for
• Class 2: (0.001 to 2) A, 1 A Nominal Secondary
• Harmonics Resolution to 40th Order • Peak Load Current: 350 mA (10 ms) Industrial Environments: 2005
• F ault Current Withstand (at 23 °C):
• Waveform up to 512 Samples/Cycle • Off State Leakage Current @350 V DC: 1uA • EN61000-6-4 – Emission Standards
100 A for 10 Seconds, 300 A for 3
Seconds, 500 A for 1 Second Update Rate: Dimensions and Shipping: for Industrial Environments: 2007
• Continuous Current Withstand: 20 A for Screw • Watts, VARs, and VA - Every 6 Cycles • Weight: 2 lbs /.91 kg • EN61326-1 - EMC Requirements: 2006
Terminated or Pass Through Connections
• All Other Parameters - Every 60 Cycles • Basic Unit: H4.85" x W4.85" x L4.25" • KEMA Certified for IEC 61850
• Programmable Current to Any CT Ratio
Power Supply: • Shark® 200 Meter Mounts in 92 mm
• Burden 0.005 VA per Phase Max at 11 A • Certified to UL/IEC 61010-1 and CSAC22.2
DIN & ANSI C39.1 4" Round Cutouts
• Option D2: (90 to 265) Volts AC and (100 No. 61010-1, UL File: E250818
• Pickup Current: 0.1% of Nominal to 370) Volts DC Universal AC/DC Supply • hark® 200T Transducer: DIN Rail
S
Class 10: 5 mA: Class 2: 1 mA Mounted Using Attached DIN Rail Clip • REACH/RoHS Compliance
• Option D: (18-60) Volts DC (24
• Pass Through Wire Diameter: 0.177” / 4.5 mm to 48 VDC Systems) • Shipping Container Dimensions: 6” Cube • New York State approved for
• Burden: 10 VA Max residential metering
Ordering Information - All fields must be filled in to create a valid part number.
Model Frequency Current V-Switch™ Power I/O Slot 1* I/O Slot 2* Mounting
Range Input Pack Supply (Shark® 200 Meter)
Option - - - - - - -
Numbers:
Example: Shark200 - 60 - 10 - V2 - D2 - INP100S - X - X
Shark200 60 10 V1 D2 X X X
(Meter/Transducer) 60 Hz System 10 A Multifunction Meter Only (90-265) V AC/ None None ANSI Mounting
Secondary DC
V3 PO1S PO1S
Power Quality Harmonic 4 Pulses/4 Status 4 Pulses/4 Status
Accessories V4 1mAOS 1mAOS
Limits & Control 4 Channel Analog 4 Channel Analog
Communication Converters Output 0-1 mA Output 0-1 mA
(bidirectional) (bidirectional)
9PINC RS485 to USB Adapter
V5 20mAOS 20mAOS
CAB6490 USB to IrDA Adapter 64 Samples/Cycle 4 Channel Analog 4 Channel Analog
Unicom 2500 RS485 to RS232 Converter Waveform Recording Output 4-20 mA Output 4-20 mA