Material List: Produced On 23/12/2020 With Xpress Selection V9.1.0 - Database DIL 16.1.1
Material List: Produced On 23/12/2020 With Xpress Selection V9.1.0 - Database DIL 16.1.1
Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.
1. Material List
Model Type Model Name Qty Description
Outdoor unit RHXYQ14ATL 1 Heat pump VRV IV 220V(TL)LA
RHXYQ22ATL 8 Heat pump VRV IV 220V(TL)LA
Indoor unit FXMQ250MAVE 20 VRV M-A - Ceiling Mounted Duct
Branch unit BHFP22P151 3 Outdoor unit multi connection piping kit
KHRP26A72T 4 Refnet branch piping kit
KHRP26A73T + KHRP26M73TP 13 Refnet branch piping kit
Centralized controller DCM601A51 1 intelligent Touch Manager
Gas tight joint BDGTA09 20 Daikin gas tight joint
BDGTA12 2 Daikin gas tight joint
BDGTA15 16 Daikin gas tight joint
BDGTA1512 8 Daikin gas tight joint
BDGTA19 58 Daikin gas tight joint
BDGTA22 35 Daikin gas tight joint
BDGTA2219 20 Daikin gas tight joint
BDGTA28 27 Daikin gas tight joint
BDGTA2825 1 Daikin gas tight joint
BDGTA41 31 Daikin gas tight joint
Option or add-on BRC1E63 20 Wired Remote Controller (Navigation Remote Controller)
Refrigerant R410A 86,3kg Extra refrigerant charge
Copper pipe Piping ⅜" 94,4m Soft copper pipe
Piping ⅝" 18,1m Soft copper pipe
Piping ¾" 130,5m Hard copper pipe
Piping ⅞" 94,4m Hard copper pipe
Piping 1⅛" 18,1m Hard copper pipe
Piping 1¼" 19,6m Hard copper pipe
Piping 1½" 14,5m Hard copper pipe
Piping 1⅝" 96,4m Hard copper pipe
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 1
2. Indoor Unit Details
2.1. Table of Abbreviations
Name Logical name of the device
FCU Device model name
Tmp C Indoor conditions in cooling (dry bulb temp. / wet bulb temp.)
Rq TC Required total cooling capacity
Max TC Available total cooling capacity
TC Total cooling capacity
Rq SC Required sensible cooling capacity
Max SC Available sensible cooling capacity
SC Sensible cooling capacity
Tevap Evaporating temperature of indoor unit coil
Tdis C Indoor unit discharge air temperature in cooling
Tmp H Indoor temperature in heating
Rq HC Required heating capacity
Max HC Available heating capacity
HC Heating capacity
Tdis H Indoor unit discharge air temperature in heating
Airflow Supplied airflow
Sound Sound pressure low and high
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 2
2.2. UC1 - RHXYQ66ATL
Capacity data at conditions and connection ratio (106%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Tmp H Rq HC Max HC Tdis H Airflow
°C kW kW kW kW °C °C °C kW kW °C cfm
UE1 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE2 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE3 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE4 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE5 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE6 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE7 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 3
2.3. UC2 - RHXYQ66ATL
Capacity data at conditions and connection ratio (106%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Tmp H Rq HC Max HC Tdis H Airflow
°C kW kW kW kW °C °C °C kW kW °C cfm
UE8 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE9 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE10 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE11 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE12 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE13 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE14 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 4
2.4. UC3 - RHXYQ58ATL
Capacity data at conditions and connection ratio (103%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Tmp H Rq HC Max HC Tdis H Airflow
°C kW kW kW kW °C °C °C kW kW °C cfm
UE15 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE16 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE17 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE18 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE19 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
UE20 FXMQ250MAVE 24,0 / 17,0 n/a 24,4 n/a 18,8 6,0 11,3 20,0 n/a 31,5 41,3 2543
The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 5
3. Outdoor Unit Details
3.1. Table of Abbreviations
Name Logical name of the device
Model Device model name
Tmp C Outdoor temperature in cooling
CC Available cooling capacity
Rq CC Required cooling capacity
Tmp H Outdoor conditions in heating (dry bulb temp. / wet bulb temp.)
HC Available heating capacity (integrated heating capacity)
Rq HC Required heating capacity
Piping Largest distance from indoor unit to outdoor unit
Bse Refr Standard factory refrigerant charge (5m actual piping length)
excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook
Ex Refr Extra refrigerant charge
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 6
3.2. Outdoor Details
Name Model Comb Tmp C CC Rq CC Tmp H HC Rq HC
% °C kW kW °C kW kW
UC1 RHXYQ66ATL 106 29,0 148,2 170,5 16,0 / 11,0 207,1 220,5
UC2 RHXYQ66ATL 106 29,0 141,8 170,5 16,0 / 11,0 186,7 220,5
UC3 RHXYQ58ATL 103 29,0 118,5 146,1 16,0 / 11,0 173,1 189,0
Sufficient distance should be respected between the modules according to the service & operation space rules as
mentioned in the databook.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 7
3.2.1. UC1 - RHXYQ66ATL
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 8
3.2.2. UC2 - RHXYQ66ATL
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 9
3.2.3. UC3 - RHXYQ58ATL
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 10
4. Piping Diagrams
Pipes marked with a short red stripe in the diagrams must be connected to the device with a reducing joint.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 11
4.2. Piping UC2
UC2
RHXYQ66ATL
RHXYQ22ATL RHXYQ22ATL RHXYQ22ATL
5,0m [4] 5,4m [4] 5,2m [4] 5,3m [4] 5,0m [4] 5,0m [4] 8,5m [4]
⅜"×⅞" ⅜"×⅞" ⅜"×⅞" ⅜"×⅞" ⅜"×⅞" ⅜"×⅞" ⅜"×⅞"
UE8 UE9 UE10 UE11 UE12 UE13 UE14
FXMQ250MAVE FXMQ250MAVE FXMQ250MAVE FXMQ250MAVE FXMQ250MAVE FXMQ250MAVE FXMQ250MAVE
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 12
4.3. Piping UC3
UC3
RHXYQ58ATL
RHXYQ22ATL RHXYQ22ATL RHXYQ14ATL
2,0m [4] 2,0m [4] 2,0m [4] 2,0m [4] 2,0m [4] 8,0m [4]
⅜"×⅞" ⅜"×⅞" ⅜"×⅞" ⅜"×⅞" ⅜"×⅞" ⅜"×⅞"
UE15 UE16 UE17 UE18 UE19 UE20
FXMQ250MAVE FXMQ250MAVE FXMQ250MAVE FXMQ250MAVE FXMQ250MAVE FXMQ250MAVE
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 13
5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook.
F1F2 = Please select the cable type and size in accordance with the databook.
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 14
5.2. Wiring UC2
to centralized controller
P1,P2
UC2 BRC1E63
UE8
RHXYQ66ATL
FXMQ250MAVE
OUT F1,F2 IN F1,F2 F1,F2
RHXYQ22ATL L, N 10,1A 1ph
Q1,Q2 L1,L2,L3 P1,P2
76A 3ph UE9 BRC1E63
FXMQ250MAVE
RHXYQ22ATL F1,F2
Q1,Q2 L1,L2,L3 L, N 10,1A 1ph
76A 3ph P1,P2
UE10 BRC1E63
RHXYQ22ATL FXMQ250MAVE
Q1,Q2 L1,L2,L3 F1,F2
76A 3ph L, N 10,1A 1ph
P1,P2
UE11 BRC1E63
FXMQ250MAVE
F1,F2
L, N 10,1A 1ph
P1,P2
UE12 BRC1E63
FXMQ250MAVE
F1,F2
L, N 10,1A 1ph
P1,P2
UE13 BRC1E63
FXMQ250MAVE
F1,F2
L, N 10,1A 1ph
P1,P2
UE14 BRC1E63
FXMQ250MAVE
F1,F2
L, N 10,1A 1ph
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 15
5.3. Wiring UC3
to centralized controller
P1,P2
UC3 BRC1E63
UE15
RHXYQ58ATL
FXMQ250MAVE
OUT F1,F2 IN F1,F2 F1,F2
RHXYQ22ATL L, N 10,1A 1ph
Q1,Q2 L1,L2,L3 P1,P2
76A 3ph UE16 BRC1E63
FXMQ250MAVE
RHXYQ22ATL F1,F2
Q1,Q2 L1,L2,L3 L, N 10,1A 1ph
76A 3ph P1,P2
UE17 BRC1E63
RHXYQ14ATL FXMQ250MAVE
Q1,Q2 L1,L2,L3 F1,F2
55A 3ph L, N 10,1A 1ph
P1,P2
UE18 BRC1E63
FXMQ250MAVE
F1,F2
L, N 10,1A 1ph
P1,P2
UE19 BRC1E63
FXMQ250MAVE
F1,F2
L, N 10,1A 1ph
P1,P2
UE20 BRC1E63
FXMQ250MAVE
F1,F2
L, N 10,1A 1ph
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 16
6. Device Options
6.1. Outdoor Unit Options
Model Description Used by
BHFP22P151 Outdoor unit multi connection piping kit UC3 [RHXYQ58ATL] UC2 [RHXYQ66ATL] UC1 [RHXYQ66ATL]
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 17
7. Centralized Controllers
7.1. Concept
Control Groups Specific Controller Models
Control group 1
iTouchManager
UC1 (7) # outdoors 3
UC2 (7) # indoors 20 # controllers 1
UC3 (6)
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 18
7.2. Control group 1
UC1 (7)
RHXYQ66ATL OUT F1,F2
UC3 (6)
RHXYQ58ATL
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 19