PCM 600 Protection and Control Manager

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 62

_______________ __________

_____ ____
_____
ABB Power ____
Technology PCM 600
_____ ____
Products
_____ ____ Protection and control
manager

Substation Automation Products

Protection and Control Manager


PCM 600
PCM 600- What does it mean?

Protection and Control Manager for the 600 series


A common tool for all ABB products globally, designed for IEC 61850
Backwards compatible with most products

© ABB Group
Slide 2
1MRG000873, November 2009
What are we talking about..
PCM 600. Introduction ON Line Help
The Navigator – PCM Frame Extra Features
Configuration Tool – ACT Signal Monitoring Tool

Signal Matrix Tool – SMT Event Viewer Tool

Setting Tool - PST


Disturbance Handling Tool
Scheduler and e-mailing
Graphic Display Editor

PC ßà REx 670 Communication Set-up


User Management and Users Levels

© ABB Group
Slide 3
1MRG000873, November 2009
Tools – PCM 600 installation CD

Installation of PCM600 tools:


- PCM600 & Tools
- Connectivity Packages

© ABB Group
Slide 4
1MRG000873, November 2009
PCM 600 – Update Manager

n This program can be used for


integrating the Connectivity
Packages with PCM 600
n It is launched from a shortcut that
is created in the desktop by
installation of the PCM 600
© ABB Group
Slide 5
1MRG000873, November 2009
Components of PCM600
PCM600 consists of:
n Configuration (ACT)
n Signal Matrix (SMT)
Configuration of:
I/O cards,
Analog Input Cards
GOOSE Recieve
n Parameter Setting (PST)
n Disturbance Handling
n Graphic Display Editor
(LCD Mimic Editor)
n Time scheduler
nSignal Monitoring
nEvent Viewer

© ABB Group
Slide 6
1MRG000873, November 2009
Tools – PCM 600 in the SA environment

© ABB Group
Slide 7
1MRG000873, November 2009
Communication PC – IED – Front Connection

© ABB Group
Slide 8
1MRG000873, November 2009
Communication PC - IEDs - Ethernet (LAB)

© ABB Group
Slide 9
1MRG000873, November 2009
Communication PC - IEDs - ETHERNET

© ABB Group
Slide 10
1MRG000873, November 2009
Communication setting

n Easy set-up of IP address for


each IED from PCM600.
n Standard Windows Control
Panel for set-up of PC
ethernet card

© ABB Group
Slide 11
1MRG000873, November 2009
Configuration tool ACT

© ABB Group
Slide 12
1MRG000873, November 2009
PCM600-Functions list
After inserting the function blocks in ACT list of function
is associated to your IED in PCM600

Save

© ABB Group
Slide 13
1MRG000873, November 2009
Signal Matrix Tool (SMT)

SMT is the tool to define relationship


between VIRTUAL INPUT/OUTPUT
signals and REAL INPUT/OUTPUT
signals.
© ABB Group
Slide 14
1MRG000873, November 2009
SMT: How it works in practice

Without changing ANYTHING in ACT


Configuration, I want to physically
connect same signal to BINARY
INPUT 5 instead of BINARY NPUT 1.

I WILL USE SMT!

© ABB Group
Slide 15
1MRG000873, November 2009
SMT: How it works in practice

© ABB Group
Slide 16
1MRG000873, November 2009
Signal Matrix Tool (SMT)

© ABB Group
Slide 17
1MRG000873, November 2009
The result of Input Configuration:
SMT

ACT

BINARY INPUT CARD


IN SLOT 3
© ABB Group
Slide 18
1MRG000873, November 2009
SMT: Virtual and Real Binary Outputs
THIS IS WHAT YOU DO in ACT:

Signal matrix Binary output(“Virtual


binary output block”)

© ABB Group
Slide 19
1MRG000873, November 2009
SMT for Binary Outputs

THIS IS WHAT YOU DO IN SIGNAL MATRIX TOOL:

© ABB Group
Slide 20
1MRG000873, November 2009
The role of SMT for Binary Outputs

© ABB Group
Slide 21
1MRG000873, November 2009
Analog Input Configuration

© ABB Group
Slide 22
1MRG000873, November 2009
Configuration of Analog Inputs in ACT

© ABB Group
Slide 23
1MRG000873, November 2009
HMI LED Configuration

© ABB Group
Slide 24
1MRG000873, November 2009
Settings

Possibility to show Basic Settings or ”Advanced Settings”

© ABB Group
Slide 25
1MRG000873, November 2009
Parameter Setting Tool

© ABB Group
Slide 26
1MRG000873, November 2009
Settings

Possibility to filter the parameters

© ABB Group
Slide 27
1MRG000873, November 2009
Settings

These 2 parameters
have been changed!

© ABB Group
Slide 28
1MRG000873, November 2009
download/upload

© ABB Group
Slide 29
1MRG000873, November 2009
PCM600 – Importing a project (decompression)

© ABB Group
Slide 30
1MRG000873, November 2009
PCM600 – Importing a project (decompression)

© ABB Group
Slide 31
1MRG000873, November 2009
PCM600 – Exporting a project (compression)

Project Structure
Settings
Configuration
Uploaded Disturbances
Communication Settings..
…… Everything!

© ABB Group
Slide 32
1MRG000873, November 2009
PCM600 – Exporting a project (compression)

© ABB Group
Slide 33
1MRG000873, November 2009
PCM600 – Exporting a project (compression)

© ABB Group
Slide 34
1MRG000873, November 2009
© ABB Group
Slide 35
1MRG000873, November 2009
Engineering Flow – Upload all

© ABB Group
Slide 36
1MRG000873, November 2009
PCM600 Engineering

n Create a new project

© ABB Group
Slide 37
1MRG000873, November 2009
PCM600 Engineering

n Build the structure


n Insert Region
n Insert Substation
n Insert Voltage Level

© ABB Group
Slide 38
1MRG000873, November 2009
PCM600 Engineering

n Build the structure


n Insert Bay’s
n Insert IED’s

© ABB Group
Slide 39
1MRG000873, November 2009
PCM600 Engineering

n Final structure
n To be consider about..
n No spaces allowed for
the item names in the
structure

© ABB Group
Slide 40
1MRG000873, November 2009
PCM600 Engineering

© ABB Group
Slide 41
1MRG000873, November 2009
Disturbance handling

© ABB Group
Slide 42
1MRG000873, November 2009
Disturbance Report Tool – The report
The Disturbance (Disturbance 1)

Automatic scaling ”around”


the perturbation
Automatic visualisation of
binary signals related to the
event
Automatic estimation of fault
quantities

© ABB Group
Slide 43
1MRG000873, November 2009
Disturbance Report Tool – The report
The Disturbance (Disturbance 1)
Estimated fault voltage
(the time of calculation is
indicated here)

© ABB Group
Slide 44
1MRG000873, November 2009
Disturbance Report Tool – The report
The Disturbance (Disturbance 1)
Estimated fault voltages and
currents
(the time of calculation is
indicated here)

© ABB Group
Slide 45
1MRG000873, November 2009
Time Scheduler

© ABB Group
Slide 46
1MRG000873, November 2009
E-mailing

It is possible to e-mail a notification to several users as soon as a new


disturbance has been uploaded from an IED.

© ABB Group
Slide 47
1MRG000873, November 2009
Graphic Mimic Editor

© ABB Group
Slide 48
1MRG000873, November 2009
Graphical Display Editor (Mimic Editor)

© ABB Group
Slide 49
1MRG000873, November 2009
Graphical Display Editor (Mimic Editor)

Easy ”drag and drop” graphic


design

© ABB Group
Slide 50
1MRG000873, November 2009
Signal Monitoring

© ABB Group
Slide 51
1MRG000873, November 2009
Start Online Monitoring

© ABB Group
Slide 52
1MRG000873, November 2009
Manual Refresh

© ABB Group
Slide 53
1MRG000873, November 2009
Event Viewer

Ø Internal Events
Ø Event List
© ABB Group
Slide 54
1MRG000873, November 2009
Event Viewer

© ABB Group
Slide 55
1MRG000873, November 2009
© ABB Group
Slide 56
1MRG000873, November 2009
Event Viewer

© ABB Group
Slide 57
1MRG000873, November 2009
PC ßà IED Communication Set-up

© ABB Group
Slide 58
1MRG000873, November 2009
IEC 61850 Communication

Is it really so simple? Just enter the IED TCP/IP address?


Where are the other settings for subnet-mask etc?

They are in Windows:


Control Panel / Network Connection / LAN / TCP/IP / Properties

What about if you need to have a different subnet mask or if you


cannot give a fixed TCP/IP address to your PC?
à A solution is to use 2 network cards in the same PC.

© ABB Group
Slide 59
1MRG000873, November 2009
Users Management and User Levels

There are 3 user levels with passwords.


Their authority has to be defined.

© ABB Group
Slide 60
1MRG000873, November 2009
On Line Help
Just ”SELECT and press F1”:

© ABB Group
Slide 61
1MRG000873, November 2009
© ABB Group
Slide 62
1MRG000873, November 2009

You might also like