Today's Date 21-Sep-2020

Colocation Application Colo Application Date 8-Mar-2019


Revision 0
Have charge Yes

PROTELINDO SITE ID Island Province City


JAW-BTN-0058-T-B Java Banten Tangerang

Latitude (Decimal/DMS) Longitude (Decimal/DMS) Site Type Tower Type


-6.24021 106.68942 RT SST
Building Height Tower Height Vertical Space On Tower Tower Extension Required
9.2 20 (from: 26.20 m to 29.20 m) YES X NO

CLIENT Client Site ID Client Site Name Client Contact Contact Phone #
SMARTFREN ZJKT2_5435/JAK0891 PERUMAHANWISMATAJURMW_NEW Lukman Wahyudi 8881853041
The information provided into this application is valid for 15 calendar days.
1. BTS ANTENNAS (RF) DETAILS CABLES
Item e - exist Dimensions (mm)
n - new Height (m) Quant Manufacturer Model Azim (0) Quant Size (")
r -remove (LxWxD)

1.1 n 27.7 1 Rosenberger BA-B74Q7X90V-00 2690 x 349 x 199 0 0 0

1.2 n 27.7 1 Rosenberger BA-B74Q7X90V-00 2690 x 349 x 199 120 0 0

1.3 n 27.7 1 Rosenberger BA-B74Q7X90V-00 2690 x 349 x 199 240 0 0

1.4

1.5

1.6

1.7

1.8

1.9

1.10

Remarks: Share Elevation

2 . MW ANTENNAS (Transmission) DETAILS CABLES


Item e - exist
n - new Height (m) Quant Manufacturer Model Diameter (m) Azim (0) Quant Size (")
r -remove

2.1 n 29 1 Unknown Unknown 0.3 0 0 0

2.2

2.3

2.4

2.5

2.6

2.7

2.8

2.9

2.10

2.11

2.100

3. TMA/ODU/RRU/FILTER/OTHERS DETAILS CABLES


Item e - exist Dimensions (mm)
n - new Height (m) Quant Manufacturer Model Azim (0) Quant Size (")
r -remove (LxWxD)
3.1 n 27.7 1 ZTE R8862A 425 x 220 x 133 0 0 0
3.2 n 27.7 1 ZTE R8862A 425 x 220 x 133 0 0 0
3.3 n 27.7 1 ZTE R8862A 425 x 220 x 133 0 0 0
3.4 n 27.7 1 ZTE ZXSDR R8978 430 x 400 x 125 0 0 0
3.5 n 27.7 1 ZTE ZXSDR R8978 430 x 400 x 125 0 0 0
3.6 n 27.7 1 ZTE ZXSDR R8978 430 x 400 x 125 0 0 0
3.7 n 27.7 1 ANDREW Filter 256 x 174 x 109 0 0 0
3.8 n 27.7 1 ANDREW Filter 256 x 174 x 109 0 0 0
3.9 n 27.7 1 ANDREW Filter 256 x 174 x 109 0 0 0
3.10
Remarks:
e - exist
n - new
r -remove
Length Width 4 . GROUND SPACE DETAILS
4.1 n 1.2 3 Equipment Pad Dimension

4.2

4.3

4.4

4.5

ADDITIONAL LEASED/SITAC REQUIRED : YES NO DIMENSIONS Length : Width :

ADDITIONAL CME CAPEX REQUIRED : YES NO DIMENSIONS Length : Width :

Remarks:

5. SHELTER/POWER REQUIREMENTS
TYPE OF EQUIPMENT REQUIRED : INDOOR (SHELTER) X OUTDOOR (CABINET) OTHER
ELECTRICITY REQUIREMENTS : kVA : 6.6 n x A (phases) : 3 phases
PERMANENT GENSET REQUIRED : YES NO DIMENSIONS Length : Width :

Remarks:

Prepared by Leasing Engineering Colocation Client

Prasasti N

Date 21-Sep-2020 Date Date Date Date


* The requested Coax Cable size is greater than the specification allowed in the MLA. Lessee must install the cables using a feeder cable clamp to reduce the wind loading effect on the tower.
Lessee acknowledges certain sites require permanent genset (no PLN available) and will be responsible for providing its own permanent power.

Lessee hereby agrees to guarantee that the equipment installed or requested to be installed, at or on the tower is solely for the interest of Lessee. If Protelindo finds any evidence which indicates that any
equipment installed, or requested to be installed, at or on the tower will be used to broadcast spectrum and/or frequency which is not allocated by the Government to Lessee, Protelindo shall deem that
Lessee has installed additional equipment on the tower, and charge Lessee with a full colocation rate in addition to the applicable lease fee.