Recovery Boiler Air Systems Rick A. Wessel, PH.D
Recovery Boiler Air Systems Rick A. Wessel, PH.D
Recovery Boiler Air Systems Rick A. Wessel, PH.D
Slide 3
4.5-1
Slide 5 shows just the combustion air Until recently, the combustion air to all
system with the fans, ducting and air levels was preheated. Now there are many
heaters. There is more than one forced draft applications where unheated air is used
fan on most recovery boilers. In this case, above the liquor gun level. The furnace gas
two fans deliver air through large air heaters at this level is nearly 2000°F (~1100°C) so
located in the ducting to the primary and air preheating is not required. Cold tertiary
secondary air level while a third fan delivers air also increases jet penetration due to its
ambient air to the tertiary level. high density; this promotes mixing of the
flue gases.
Slide 5
Slide 7
Secondary Air
Air
Heater
Air
Primary Air
Duct
4.5-2
AIR SYSTEM ARRANGEMENTS AND The Role of Primary Air
Slide 10
Slide 9
Characteristics of Turbulent Jets
1
Centerline Velocity, V c /V n
• Jet Expansion
0.6
Vn = nozzle velocity
Slide 12 describes the role of the secondary
0.4
0.2
air in a recovery furnace.
0
0 10 20 30 40 50
Tube Distrance from Nozzle, z/Dn Slide 12
Wall
Velocity
The Role of Secondary Air
Windbox Profile
= 0.2
Jet, V/V c
Edge of
Air Port
Nozzle
Jet Centerline Expansion
Angle ~16° • Secondary air controls char bed height
– Jet penetration to center of furnace needed
Gas
Entrainment – Large ports and high pressure air required
• Secondary air burns char and volatiles
Slide 10 describes the role of the primary air – Intensive mixing of air and combustion gases
in a recovery furnace. Slide 11 presents an – Heat release needed to dry liquor spray
inside view of primary air ports and • Optimized to match liquor firing conditions
discusses their arrangement.
4.5-3
Slide 13 shows three common arrangements Slide 15 shows a similar result for a 2-wall
for the secondary air nozzles. The 4-wall partial interlace arrangement which uses a
arrangement is most common on older pattern of large jets opposed by small jets in
boilers, but 2-wall arrangements are used on a similar interlace configuration. There is
most retrofits and new boilers. The slightly less penetration of the large jets
interlaced arrangement in the center of Slide with this arrangement because some of the
13 is a 4x3 nozzle pattern. The arrangement flow is diverted to the small jets, but the two
of air nozzles allows sufficient room for jet flow patterns are otherwise similar.
expansion without interference from
neighboring jets. Flow Pattern for Partial Interlace Slide 15
Slide 13
Secondary Air Arrangements
Small Large
Jet Jet
4.5-4
Slide 17 describes the role of the tertiary air Slide 19 lists several tertiary air port
in a recovery furnace. Reducing conditions arrangements that are commonly used in
in the lower furnace improve smelt recovery boilers.
reduction and reduce NOx emissions.
Oxidizing conditions in the upper furnace Alternate Tertiary Air Arrangements
Slide 19
4.5-5
Slide 21 describes how an air system Air System Operating Problems
Slide 22
Louver damper
AIR SYSTEM PROBLEMS • Adjusts flow rate
• pressure and velocity
Two of the problems encountered with decrease with flow rate
recovery boiler air systems are their Velocity damper
inflexibility once installed, and their need • Adjusts air port nozzle
for frequent port cleaning. This is described area and flow rate
4.5-6
must be cleaned periodically. The traditional Slide 26
Isolation Damper
Air Port Opening
te d
rac
Ret
ed
end
Ext Flow problems can also be generated by
other equipment in the delivery ducts. The
velocity vectors in Slide 27 show the very
non-uniform flow pattern that is generated
by one type of damper arrangement. If this
There are several other potential design damper were near an elbow or nozzle, air
problems with recovery boiler air systems. delivery could be very non-uniform and
These are described in Slide 25. intermittent.
Slide 25 Slide 27
Air System Design Problems Damper Flow Problems
Slide 26 shows one example of the type of Slide 28 shows 4-wall and 2-wall secondary
problem that can be encountered in air duct air arrangements with significant jet
and air nozzle design. In this case, the interference. The air jets cannot traverse the
nozzle in the top of the slide is not being fed furnace without crashing into opposing jets,
uniformly. This causes improper air flow and being deflected away from a path of free
through the nozzle and therefore poor penetration. For the two-wall secondary air
furnace operation. The lower nozzle arrangement, the air nozzles are too tightly
arrangement shows an inexpensive spaced for the jets to expand and form an
modification used to solve this problem. effective interlace.
4.5-7
Slide 28 SUMMARY
Jet Interference
Slides 30 and 31 summarize the main points
from this introduction to recovery boiler air
system design and operation.
Inter-
ference Interference
Slide 30
Implications for RB Air Systems
Gas
Recirculation FURTHER READING
Adams, T. N., General Characteristics of
Air Nozzles Kraft Black Liquor Recovery Boilers,
Char bed
Chapter 1 of Kraft Recovery Boilers,
Adams, T. N., Ed., TAPPI Press, Atlanta,
Gas flow channeling can result in severe GA, pp. 1-38 (1997).
carryover fouling in the upper furnace and
insufficient gas mixing to destroy TRS gases Jones, A. K., Recovery Boiler Air Supply
that are released in the lower furnace and Gas Flows, Chapter 7 of Kraft Recovery
reducing zone. Boilers, Adams, T. N., Ed., TAPPI Press,
Atlanta, GA, pp. 181-214 (1997).