Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Work Station - Saab TankRadar® MaC

The same type of PC is used as Work Station for both Saab TankRadar® MaC and
Saab TankRadar® G3.

A large 21" color monitor is included as standard on the MaC Work Station. The
large screen provides ample space for the mimic in the control windows of the Work
Station software.

The design of the operator´s interface in the MaC Work Station software is very
similar to that of Saab TankRadar® G3. In this way the operator can comfortably
switch between monitoring and control windows.

The control windows of the Work Station software contain mimic diagrams showing
tanks, pumps, valves, sensors etc. A standardized set of graphic symbols and
layouts are used to make the windows as clear and user-friendly as possible.
Following these standards, each of the control windows are specially made
according to the requirements of each customer.

A number of Work Stations can be placed in a network at various locations onboard.


By connecting the optional Redundancy Box, a redundancy can be obtained, allowing
one of the master Work Stations to fail.

Welcome to view an illustration showing an example of a control window (66


kB).

You control a valve or a pump or any other controllable device by pressing the Light
Pen against its symbol on the Work Station´s screen with the Light Pen.

A device can be controlled in two different ways: either in an on/off manner or in an


analog manner.

Hit the device´s symbol lightly with the Light Pen and a small control window is
opened, where you can enter the desired control setpoint of the device.
Technical Data for MaC Work Station
Computer Type approved PC
Monitor Saab TankRadar® Mac 21" monitor (Width x Height x Depth)
Operating System QNX
Power supply 115 VAC +10 to -15%, 47-63 Hz or
230 VAC +10 to -15%, 47-63 Hz
Dimensions
- PC, Monitor, mounting plate
- Keyboard 415 x 545 x 425 mm
Keyboard 470 x 40 x 195 mm
(Width x Height x Depth)

Work Station Redundancy (Option)

When two or more Work Stations are connected in a network, two of them can be
configured as masters and be connected to the Redundancy Box. If the active
master Work Station fails, the redundant master will automatically detect this and
take over control of the system.

The Redundancy Box switches the signal to the active master. The active master
has exclusive control over the Redundancy Box. Only one of the master Work
Stations is active at any one time. The redundant master Work Station works like any
slave Work Station until it detects that the active master has failed.

Technical Data for the Redundancy Box


Connection to Work RS-232 and Bitbus, max 3 m. Cable supplied by Saab
Station Marine Electronics
Power supply 115 VAC +10 to -15%, 47-63 Hz or 230 VAC +10 to -15%,
47-63 Hz
Dimensions 280 x 230 x 110 mm (Width x Height x Depth)
Work Station - Saab TankRadar® MaC

The same type of PC is used as Work Station for both Saab TankRadar® MaC and
Saab TankRadar® G3.

A large 21" color monitor is included as standard on the MaC Work Station. The
large screen provides ample space for the mimic in the control windows of the Work
Station software.

The design of the operator´s interface in the MaC Work Station software is very
similar to that of Saab TankRadar® G3. In this way the operator can comfortably
switch between monitoring and control windows.

The control windows of the Work Station software contain mimic diagrams showing
tanks, pumps, valves, sensors etc. A standardized set of graphic symbols and
layouts are used to make the windows as clear and user-friendly as possible.
Following these standards, each of the control windows are specially made
according to the requirements of each customer.

A number of Work Stations can be placed in a network at various locations onboard.


By connecting the optional Redundancy Box, a redundancy can be obtained, allowing
one of the master Work Stations to fail.

Welcome to view an illustration showing an example of a control window (66


kB).

You control a valve or a pump or any other controllable device by pressing the Light
Pen against its symbol on the Work Station´s screen with the Light Pen.

A device can be controlled in two different ways: either in an on/off manner or in an


analog manner.

Hit the device´s symbol lightly with the Light Pen and a small control window is
opened, where you can enter the desired control setpoint of the device.
Technical Data for MaC Work Station
Computer Type approved PC
Monitor Saab TankRadar® Mac 21" monitor (Width x Height x Depth)
Operating System QNX
Power supply 115 VAC +10 to -15%, 47-63 Hz or
230 VAC +10 to -15%, 47-63 Hz
Dimensions
- PC, Monitor, mounting plate
- Keyboard 415 x 545 x 425 mm
Keyboard 470 x 40 x 195 mm
(Width x Height x Depth)

Substation

The Substation contains electronics and wire terminals for input


signals as well as control signals. The main function of the
Substation is to handle the signals between the Work Station and
the connected control equipment.

Signals from various devices, such as valve positions, pressures


and temperatures, are sent to the Substation where they are
processed and sent to the Work Station for presentation. When
the operator orders actions from a Work Station, these orders are
sent to a Substation. From the Substation, control signals are sent
to the corresponding equipment, such as on/off switches, pumps
and valves.

Each Substation handles input/output signals to and from:

• Valves and pumps (actuators and feedbacks).

• Temperature and pressure sensors.

• On/off switches.

• Other types of sensors and equipment (refer to Technical Specifications).

Technical Data for the Substation


Cabinet
Dimensions 600 x 950 x 415 mm
(Width x Height x Depth)
Extension cabinet
Dimensions 600 x 950 x 415 mm
(Width x Height x Depth)
Substation Input channels
Resistance Temperature Detectors Pt100 according to DIN or JIS standards
(RTD) Type
Current Transmitters
- Current range 4 to 20 mA (0 to 20 mA)
- Input resistance Input resistance 50 Ohm, max
- Accuracy ± 1% of full range
Potentiometers
- Total resistance 1 kOhm, min
- Accuracy Limited by potentiometer linearity
Digital Inputs (voltage-free contacts)
- Supply 24 V
- Load current 2 mA
Intrinsically Safe Inputs
(multiplexors)
I.S. RTD-MUX (15 Pt100 elements)(RTD)
-50 to +100 °C (-58 to +212 °F)
- Range +/-1 °C
- Accuracy SP (EEx ia) IIC
- Approval
I.S. Pot-Mux (15 Potentiometers)
- Range 1 to 10 kOhm
- Approval SP, (EEx ia) IIC
Substation Output Channels
Analog
- Current 0 to 20 mA or 4 to 20 mA
- Accuracy ±0.5% of full scale
- Voltage -10 to +10 V
- Accuracy ± 0.2% of full scale
Digital
- Transistor output (open collector) 30 V, 100 mA, max
- Relay contacts nominal 250 V, 2 A, max

You might also like