Corporate Office & Zonal Office (West)

Solitare Corporate Park, Building No. - 11,


5th Floor, 167, Guru Hargovindji Marg,
Andheri - Ghatkopar Link Road,    
Chakala, Andheri (E), Mumbai - 400 093,
Maharashtra, India.
Ph.: (91 - 22) 6709 1900
Fax: (91 - 22) 6709 1924/25/26

Zonal Office (North)


Unit No. 1008, 10th Floor, WTT Tower - B,
Plot No. C - 1, Sector - 16,
Noida - 201 301
Ph.: (91 - 120) 4879 050, 4879 073

Zonal Office (South)


39 - I, North Parade Road, Chakrapani Colony,
St. Thomas Mount, Chennai - 600 016 Exclusion of Liability
Ph.: (91 - 44) 2231 3633/59/60 The information contained herein is provided for
Fax: (91 - 44) 2231 3644/45 general reference purpose only. By providing the
information contained herein, Supreme Petrochem
Zonal Office (East)
Ltd makes no guaranty or warranty, and does not
183, Rajdanga, Block BF II, 1st Floor, assume any liability, with respect to the accuracy or
Shantipally, Kolkata - 700 107 completeness of such information, or the product
Ph.: (91 - 33) 2441 7069 results in any specific instance and hereby
Fax: (91 - 33) 2441 7039 expressly disclaims any implied warranties of
merchantability or fitness for a particular purpose,
Sales Office (Bengaluru)
or any other warranties or representations
No. 314/C, 1st Floor, Countour Road,
whatsoever, expressed or implied. Nothing
Padmanabha Nagar, Bengaluru - 560 070 contained herein shall be construed as a license to
Telefax: (91 - 80) 2679 1315 use the products of Supreme Petrochem Ltd in any
manner that would infringe any patent.
Sales Office (Hyderabad)
No. 202, Gruhashilpi Apartments, 14-47,
P & T Colony, Dilshuk Nagar,
Hyderabad - 500 060
Telefax: (91 - 40) 2006 0369

Email : insuboard@spl.co.in,
xps_marketing@spl.co.in

Website : www.supremepetrochem.com,
www.insuboard.com
Create
  

This revision (Oct,2018) supersedes all previous editions.


environment
 
Introduction Technical Specifications

Supreme Petrochem Ltd, part of Supreme Group of companies, is the largest TEST PARAMETER UNIT TEST METHOD SPECIFICATIONS
producer of Polystyrene & Expandable Polystyrene beads in India, key raw
40 mm
materials for making Thermal Insulation Boards/Sheets. State-of-art Board Thickness mm 20 25 30
and above
manufacturing facilities are located in Nagothane, Maharashtra and
Chennai, Tamilnadu. Compressive Strength @ kPa 180 240 290 350
ASTM C 1621
10% Deflection, minimum (psi) (26) (35) (42) (51)

Description Equivalent Thermal


W/m.K ASTM C 518 0.0289* 0.0289* 0.0289* 0.0289*
Conductivity, maximum
– Extruded Polystyrene (XPS) Thermal Insulation Board is a rigid foam Flexural Strength, minimum kPa ASTM C 203 345 345 414 414
board having closed cell structure and is produced in a fully automated
Water Vapor permeance of
continuous extrusion process in accordance with international specifications ng/Pa.s.m2 ASTM E 96 63* 63* 63* 63*
25.4 mm thickness, maximum
and standards. Its unique properties of high compressive strength, higher
R value and low water absorption makes it an ideal insulating material for roofs, Water Absorption by
% v/v ASTM C 272 0.3 0.3 0.3 0.3
total immersion, maximum
walls and floors.
Dimensional Stability (change in
% ASTM D 2126 2 2 2 2
Key Features Dimensions), maximum
Oxygen Index, minimum % v/v ASTM D 2863 24 24 24 24
• High resistance to heat flow, i.e. low • High compressive strength,
thermal conductivity. compared to other insulation Density, minimum kg/m3 ASTM D 1622 34 34 34 34

• High insulation value long term. materials. Flammability Class DIN 4102 Part1 B2* B2* B2* B2*
• Resistance to water vapour diffusion • Light weight and easy to handle. Surface Burning Characteristics Class ASTM E 84 A A A A
and water absorption. • Resistance to bacteria and micro Board size 600X1250mm 600X1250mm 600X1250mm 600X1250mm
• Long term durability. organism growth.
• Uniform density distribution. • Non-toxic.
meets the ASTM C 578 Type VI standard requirements for boards with thickness of 30 mm and above;
The cost of energy and demand for air conditioning in buildings is constantly increasing. With increased energy and for thickness less than 30 mm meets ASTM C 578 Type IV standard requirements.
conservation becoming more and more relevant, the ability of the product selected to effectively insulate a building of is made from CFC/HCFC Free Blowing Agents.
whatever type is very important. For parameters with (*) mark, the product is “TYPE TESTED” once in six months in BIS / MoEF / DGS&D / DDCA
Insulation should be viewed as a long term investment. Consequently, one of the best ways to optimize this investment approved laboratory.
is by choosing high quality and effective insulation material for buildings. Above specifications are for our “STANDARD product”.
with lower thermal conductivity, higher compressive strength, higher density or B1 fire rating are available, on
Properties
specific requests. Please contact SPL Marketing Representative for the same.
Heat Flow: provides an excellent resistance to heat flow. There is no change in the K value Application Guide: Customers are advised to use appropriate Building Codes and Regulations applicable in their region
(Thermal conductivity) of the material after prolonged usage and hence the heat flow into/out of before using . Supreme Petrochem Ltd assumes no liability, whether expressed or implied, of the intended
the system remains intact. application.
Water Vapour: Closed cell structure of provides exceptional resistance to water permeability and will Disclaimer: Data presented in this specification sheet are typical values and are intended to serve as guide only.
absorb less than 1% water by volume. SPL reserves the right to review and alter the contents of this specification sheet without prior notice.
Density: has a uniformly high density and compressive strength, making it an ideal solution for
over deck insulation and floor insulation in cold storages. Adhesive Framework Adhesive Adhesive
Reinforced
Fire: is tested as per DIN 4102 and is available in both class B2 & B1. Exterior
Plaster Cement
Vegetation Aluminium Plaster
Dimensional Stability: The regularity and homogeneity of cellular composition ensures good dimensional stability. Composite
Panel
Cement
Application: is ideal for energy conservation in a wide range of industrial, commercial buildings and in Growing Medium
Plaster
(8- Inches)
private dwellings. Cement
Plaster Wall
Filter Fleece/ Finish
is mainly used for thermal insulation of flat and pitched roofs, under deck insulation, external, internal and cavity Root Repellent
Drainage Layer

wall insulation, industrial and cold storage floors and underground constructions. Insulation Layer

Waterprooof
Membrane

Available Thickness Standard Size Structural Support


CAVITY WALL WALL INSULATION BEHIND EXTERIOR WALL
INSULATION ALUMINIUM COMPOSITE PANEL INSULATION
20,25,30,50,75 and 100 mm 600 mm x 1250 mm
Other lenghts are available upon request
Storage PVC/Glass Fiber Wire Mesh Cement Screed Brick Wall
Reinforcement
Under deck Insulation Floor Insulation Cavity Walls External Wall Insulation Systems XPS Thermal Insulation Boards
Geo Textile/Polyester
should be stored on a flat surface, Non-Woven Cloth

material should be stored in covered areas Vapour Barrier


(Plastic Film) GI Section

away from direct sunlight and ultraviolet rays.


Gypsum Board

Loosely Laid
Interlocking
XPS Boards
Screw

Paint
Roof Surface

You might also like