Electrical Machine Assignment 1

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Kalyani Government Engineering College, Kalyani

ELECTRICAL MACHINE ASSIGNMENT

Paper Code: PC-EE501


Date of Submission: 26.01.2021 (Detail Solution through google drive)
Soft copy (only answer): https://intime-tape.000webhostapp.com/provasroy/homepage.html

Department: EE Semester: 5th Session 2020-21

1 Find the no-load line voltage of a star connected 4-pole, 50 hz alternator from the following
data: Flus per pole=0.12Wb; No. of slots/pole/phase=4; Conductors/slot=4; coil
span=1500.
(i) 1250V (ii) 1150V (iii) 1278V (iv) 1367V

2 A 3-phase, 50 Hz alternator is running at 600 rpm has a 2-layer winding, 12 turns/coil, 4


slots/pole/phase, and coil-pitch of 10 slots. find the induced EMF per phase if the flux/pole
is 0.035 webers.
(i) 3451 V (ii) 2986 V (iii) 4236 V (iv) 2586 V

3. A 2-pole, 3-phase, 50Hz, star connected ac generator has 9 slots/pole and 6 conductors per
slot. What is the flus/pole if the terminal voltage on open circuit is 11000 V. Take coil span
as unity
(i) 0.2036 Wb (ii) 0.1226 Wb (iii) 0.1656 (iv) 0.1022 Wb

4 A 3 phase, 50Hz, salient pole synchronous generator is driven by a hydroelectric turbine at


a speed of 125 rpm. There are 576 stator slots with two conductors per slot. The airgap
diameter is 6.1 m and the stator length is 1.2 m. The sinusoidally distributed flux density
has a peak value of 1.1 T. Find the value of induced emf per phase.
(i) 11525V (ii) 13720 V (iii) 11210 V (iv) 12575 V

5 Find the no-load phase voltage of a star connected 16-pole, 3-phase alternator from the
following data: Flus per pole=0.016Wb; No. of slots/pole/phase=2; Conductors/slot=4; coil
span=1500(Electrical); rotor speed=375 rpm.
(ii) 650V (ii) 795V (iii) 750V (iv) 668V

6. A three phase, 50 Hz, star connected alternator with two layer winding is running at 600
rpm. It has 12 turns per pole, 4 slots per pole per phase and a coil pitch of 10 slots. If the
flux per pole is 0.035 Wb sinusoidally distributed, find the line emfs induced. Assume the
total turns per phase are series connected.
(i) 6540V (ii) 5486 V (iii) 6329V (iv) 5978 V
7. A three phase, 8-pole, narrow spread double layer winding of the armature of an alternator
is accommodated in 72 slots with 2 coil sides per slot. Select a coil span to reduce 5th
harmonics emf as much as possible and calculate the winding factor for fundamental and
5th harmonics emf.

(i) 0.9625, 0.031 (i) 0.9116, 0.047 (i) 0.8937, 0.061 (i) 0.9024, 0.038

8. A three phase, 10 pole, 600rpm, star connected alternator has 12 slots per pole with 8
conductors per slot and the windings are short chorded by 2 slots. The air gap flux per pole
contains a fundamental component of 0.09 webers, third harmonic component having an
amplitude of 20% and the fifth harmonic component having an amplitude of 10 % of the
fundamental. Calculate the RMS value of line voltage.
(i) 4662 V (ii) 5134.7 V (iii) 6540.5 V (iv) 3660.8 V

9. A three phase, 50 Hz, 10 pole star connected synchronous generator is designed with 90
slots and flux per pole of 0.15 wb. The winding has to be connected to generate a line
voltage of 11 kV. Find the number of stator conductors to be connected in series per phase
to get the required voltage.
(i) 420 (ii) 516 (iii) 396 (iii) 258

10. The flux per pole in a 6 pole, 50 Hz, star connected alternator, is 0.014 Weber. The stator
has 90 slots, double layer winding with a coil span is 12 slots and 4 conductors per slot.
The sinusoidal flux density distribution in the air gap is given by B(θ) = B1sinθ + 0.3
B1sin3θ, where θ is measured from quadrature axis. Determine (i) the magnitudes of
fundamental and 3rd harmonic fluxes
(i) 0.0127 wb, 0.00127 wb (ii) 0.0165 Wb. 0.0062 Wb (iii) 0.0176
Wb, 0.00196 Wb (iv) 0.0139 Wb, 0.00139 Wb