Concrete Mix Design: Vary

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

CONCRETE MIX DESIGN

P 6 8 8 - 0 3 0 8 - CC 0 3 4 0 1 0 R 0
Project: ETIHAD RAIL STAGE 2 & 3 PROJECT C0308 - PACKAGE 2D
Concrete Strength = Cube C60 Mpa
Location of Use : Precast Concrete - Prestressed & Post Tension Beam Girder

Type/
Material Description Unit Quantity Specification Source
Trade Name
Total Cement kg 450
Cement 67% kg 302 BS EN 197-1:2011 OPC( Type I) National Cement, UAE
GGBS 25% kg 112 BS EN 15167-1 GGBS Cemex Cement, UAE
Microsilica 8% kg 36 BS EN 13263 Microsilica Grey Matters, UAE
20 mm Aggregate kg 630 BS EN12620 Crushed Stevin Rock, RAK
10 mm Aggregate kg 450 BS EN12620 Crushed Stevin Rock, RAK
5 mm Aggregate kg 580 BS EN12620 Crushed Stevin Rock, RAK
Dune Sand kg 250 BS EN12620 Natural Al Ain, UAE
Free Water liter 145 BS EN 1008 Potable Mains
Water Absorption liter 12* BS EN 934-2 Potable Mains
Admixture liter 2.0-10.0 ASTM C494, Type F Pantarhit PRX-832 Ha - Be
Target Slump mm 200 BS EN 206 Table-11 Tolerances ± 30

Breakdown
Total Aggregates 1910
20 mm Aggregate 32.98 %
10 mm Aggregate 23.56 %
5 mm Aggregate 30.37 %
Dune Sand 13.09 %
Aggregate/Cement Ratio 4.24
Coarse Aggregate 56.54 %
Fine Aggregate 43.46 %
Free W/C Ratio 0.32
* Vary