Introducing the New Compact
New ISO-compliant valve PV5G, PV5, and CMF Series are compact,
lightweight, and energy-saving, featuring greatly improved operability,
life, and environmental innovations.
(CKD comparison)
10% Reduced
Improved operability
The manual button and power
indicator light are optimally positioned
taking operability and visibility into
consideration.Adjustment work during
installation and operability during
maintenance are improved. Enlarged view
2-color indicator
Solenoid a: red
Solenoid b: green
Power indicator light
Lighter weight
The aluminum body and resin components further
* I/O connector * DIN terminal box lighten weight.
Improved design
White tones and rounded corners complement the new
design.
Discrete valve
PV5G-6 Manifold
100 VAC
P/A/B Rc1/4, Rc3/4
CMF1
Series
MAX.
Discrete valve Φ100
PV5-6R
Series P/A/B Rc1/4, Rc3/8
I/O connector 24 VDC
Type
R 1 / R2 Rc3/8, Rc1/2
Discrete valve
MAX.
Discrete valve Φ160
PV5-8R
Series P/A/B Rc3/8, Rc1/2
I/O connector 24 VDC
Type
R 1 / R2 Rc1/2, Rc3/4
Series variation PV5G/PV5/CMF Series
Valve
Series variation/appearance Position no. of performance
solenoid JIS Voltage
symbol
Connection
Air supply R1 P R2
Exhaust
2-position double solenoid
a AB b
Individual exhaust method P → A/B
3.4 to 6.3
Individual exhaust
Discrete: Page 2 spacer CMF1-R-* R1 P R2 A/B → R1/R2 100 VAC
ISO size 1
Manifold: Page 14
3.0 to 6.9 12 VDC
Air supply 3-position all ports closed MAX. 24 VDC
Φ100
PV5-6R Exhaust a A B b
110 VAC
Individual supply
spacer CMF1-P-*
3-position all ports closed Note 1
(non-leak type)
a A B b
Exhaust Air supply Note 2
R1 P R2
Discrete: Page 36
Manifold: Page 48 Central method
3-position A/B/R connection
PV5G-8 Exhaust
a AB b
R1 P R2
DIN terminal box
Exhaust
Air supply pressurization type
3-position P/A/B connection
Multi-pressure air supply method
a AB b
A masking plate (CM1-01) lies
between manifold blocks with
different pressures, supplying two R1 P R2 P → A/B
pressures, high and low, to one 6.6 to 11.0
manifold.
Discrete: Page 8 2-position single solenoid A/B → R1/R2 100 VAC
ISO size 2
(exhaust pressurization
Manifold: Page 20 6.2 to 13.0 12 VDC
type) MAX.
Individual supply and exhaust method Φ160
24 VDC
PV5-8R Individual supply (CMF1-P-*) and
a AB 110 VAC
Note 1
and exhaust.
2-position double solenoid
(exhaust pressurization
type)
Back porting method AB
Note 2
a b
If side porting is not possible, pipes
can be connected from either the R 1 PR 2
A or B port, or all pipes can be
Discrete: Page 42 connected from the bottom of the
Manifold: Page 54 manifold.
Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 × C.
Note 2: I/O connector type is only for 24 VDC.
Intro
PV5G/PV5/CMF Series
Series variation
PV5G-6
ISO size Size 1 Size 2
PV5G-8
Manifold: CMF1 Series Manifold: CMF2 Series
DIN terminal box type: Page 2 DIN terminal box type: Page 8
Sub-plate I/O connector type: Page 36 I/O connector type: Page 42
CMF1
DIN terminal box type
Connection
Connection
Connection
Model Port size Model Port size Model Port size
no. P/A/B R1/R2 no. P/A/B R1/R2 no. P/A/B R1/R2
CMF2
porting Rc1/2 Rc1/2
CB1-A03 Rc3/8
Side Back
Rc3/8 CB2-A04 Rc1/2 CB2-B04 Rc1/2
porting porting
CB1-B02 Rc1/4
Back
CMFZ
porting CB2-A06 Rc3/4 Rc3/4 CB2-B06 Rc3/4 Rc3/4
CB1-B03 Rc3/8
DIN terminal box type: Page 14 DIN terminal box type: Page 20
Manifold I/O connector type: Page 48 I/O connector type: Page 54
Technical data,
specifications
Model no. Descriptions Specifications Model no. Descriptions Specifications
1 to 10 stations
(The control unit is 2 station Station
Station number 1 to 10 stations
or equivalent if the control number
PV5-6R
unit is included.)
A/B A/B
Rc1/4, 3/8 Rc3/8, 1/2
port port
Connecting Connecting
PV5-8R
port port
P/R1/ P/R1/
Rc3/8, 1/2 Rc1/2, 3/4
R2 port R2 port
Air filter (manual drain and automatic Individual supply CMF2-P-*
Control unit spacer
CMF1 drain) regulator and air release valve CMF2
CMF1
Individual supply CMF1-P-* Individual exhaust CMF2-R-*
Option
Masking
CM1-00 Spacer P
CMF2
plate
type CMF2-SR-A
P regulator B
Spacer type
CMF1-SR-A
regulator B
Air pilot
check CMF2-PC
CMFZ
Manifold type(The CMFZ type, combining the CMF1 and CMF2, is also available as an option.)
Technical data,
specifications
5 Individual supply and exhaust method 5 Individual supply and exhaust method
Intro
PV5G/PV5/CMF Series
PV5G/CMF (DIN terminal box type)
How to wire Electric connection circuit diagram
Electric connection (wiring method)
Blank Without power indicator light N Light and surge suppressor
1 2
AC AC
2 b SOL
3 COM
No polarity is designated when DC
power is used.
DC DC
AC AC
Double solenoid
DC DC
2 4
DC
1 COM (NPN)
2 b SOL
Double solenoid
3 COM (PNP)
4 a SOL
Pin 2 is not used for single DC
solenoid.
No4 No1 No No2
a SOL COM COM b SOL
Note: This applies when rated voltage 24 VDC is used and light and surge suppressor is installed.
Intro
Safety precautions
Always read this section before starting use.
Precautions
When designing and manufacturing a device using CKD products, the manufacturer is
obligated to check that device safety mechanical mechanism, pneumatic control circuit,
or water control circuit and the system operated by electrical control that controls the
devices is secured.
It is important to select, use, handle, and maintain the product appropriately to ensure
that the CKD product is used safely.
Observe warnings and precautions to ensure device safety.
Check that device safety is ensured, and manufacture a safe device.
WARNING
The safety cautions are ranked as "DANGER", "WARNING" and "CAUTION" in this section.
DANGER: When a dangerous situation may occur if handling is mistaken leading to fatal or
serious injuries, or when there is a high degree of emergency to a warning.
WARNING: When a dangerous situation may occur if handling is mistaken leading to fatal or
serious injuries.
CAUTION: When a dangerous situation may occur if handling is mistaken leading to minor
injuries or physical damage.
Note that some items described as “CAUTION” may lead to serious results depending on the situation.
In any case, important information that must be observed is explained.
Intro
Pneumatic components
Safety precautions
Always read this section before starting use.
Refer to Pneumatic valves No.CB-023SA for the general valves.
2. Common
WARNING
Do not block exhaust port of a manifold valve.
Other cylinders could malfunction due to back pressure
generated by switch valve exhaust. Exhaust from both
sides of the manifold or use a discrete exhaust valve with
a spacer or discrete valve for the valve.
Intro
PV5G/PV5/CMF Series
Design & Selection
Precautions
3. Surge suppressor If another device or solenoid valve is connected in
parallel to the solenoid valve, reverse voltage surge
generated at OFF status is applied to these devices.
Even when using the solenoid valve for the surge
CAUTION
suppressor for 24 VDC, surge voltage may reach
minus several ten V depending on the model. This
The surge suppressor with the solenoid valve
reverse polarity voltage could damage or cause other
protects the solenoid valve drive output contact, devices connected in parallel to malfunction. Avoid
but not other peripheral devices, meaning parallel connection with a device having weak reverse
these could be affected by surge damage or polarity voltage. (Example: LED indicator.)
malfunction. Surge generated by other devices When driving several solenoid valves in parallel, surge
could be absorbed, resulting in damage or from other solenoid valves could flow into the surge
suppressor, burning the surge suppressor.
accidents such as burning. Note the following Even when driving several solenoid valves with surge
points. suppressors, surge current will concentrate at the
The surge suppressor limits solenoid valve surge surge suppressor having the lowest limit voltage, and
voltage, which can reach several hundred V, to a low could result in similar burning. Even if the solenoid
voltage level withstandable by the output contact. This valve is the same, surge suppressor limit voltage
may be insufficient for the output circuit, however, and is inconsistent and in the worst case could result
could result in damage or malfunction. Check that the in burning. Avoid driving several solenoid valves in
surge suppressor is adequate for the surge voltage parallel.
limit of the solenoid valve used, the output device The surge suppressor in the solenoid valve may short-
withstand voltage, and circuit configuration, and the circuit if damaged by overvoltage or overcurrent
degree of return delay time. from other solenoid valves. After such damage, large
Provide separate surge measures if necessary. current flows when output is turned on, and in the
Reverse voltage surge generated at OFF status is worst case, the output circuit or solenoid valve is
suppressed to the following levels. damaged or fires start. Do not leave the solenoid valve
energized in a faulty state. Provide an overcurrent
Specifications voltage Reverse voltage value when power turned OFF protection circuit on the power or drive circuit, or use
12 VDC Approx. 27V a power supply with overcurrent protection so that no
large current flows continuously.
24 VDC Approx. 47V
When using NPN output, voltage given in the upper 4. 100/110 VAC specifications
table and surge voltage equivalent to the power
voltage could be applied on the output transistor.
Install contact protection circuits in this case.
CAUTION
The 100/110 VAC specifications have a built-in all-
<Example of output transistor protective circuit
installation 1> wave-rectified bridge.
When using an SSR to turn the solenoid valve on and
off, a solenoid valve reset fault may occur depending
on the SSR type. Select the SSR appropriately.
Consult with the relay or PLC manufacturer for details.
Intro
PV5G/PV5/CMF Series
Installation & Adjustment
Apply adequate torque when connecting pipes to
1. Common
prevent air leak and to protect thread.
Tighten by hand at first, then use
CAUTION the tool, so as screw thread is not
damaged.
When using the pilot check valve (PV5G-*-
FPG-D, CMF*-PC) to hold the cylinder when
(Reference value)
pressure supplied next is too low, operation
could fail because of the pressure balance on
the poppet valve's primary and secondary sides. Set screw Tightening torque N•m
0.6
Rc 1/8 3 to 5
0.5 Rc 1/4 6 to 8
Supply pressure
When using the pilot check valve when back 2. DIN terminal box
pressure is applied on exhaust ports R1 and R2,
the cylinder or braking accuracy could drop. An CAUTION
individual exhaust spacer (CMF*-R) should be
used in combination to prevent back pressure. Use a JIS C3312 (600 V vinyl insulated vinyl
cable) with a core cross-section of 0.75 mm2 or
Do not transport the solenoid valve by the cable. 1.25 mm2 with 2, 3, or 4 cores (outer diameter:
The cable could break. ø8.5 to 11.5) for the cable.
Tu r n p o w e r o f f e x t e r n a l l y b e f o r e s t a r t i n g Use a crimp terminal on the cable to prevent
installation or wiring work. There is a risk of connection faults and disconnection.
electrical shock or damage. (Example: Use a 1.25 Y-3U, 1.25-3.5 S, 1.25-4
Check the product's rated voltage and terminal M with inner diameter of M3.5 and outer
layout and wire the product correctly. Connecting diameter of 7 mm or less.)
an incorrect power rating or incorrect wiring
Incorrect terminal connections will cause
could result in fires or faults.
malfunctions.
Tighten the waterproof connector and terminal Refer to Page 5 in the Introduction for correct
screws within the specified torque range. A loose connection.
connection could result in fires or malfunctions.
WARNING CAUTION
If valves are assembled or disassembled, The oil-free property cannot be maintained if oil is
read the instruction manual of the product supplied to the prelubricated valve even once.
very well and understand the contents before Once lubricated, continue the lubrication.
disassembling and assembling the product. Pneumatic components to be oil-free or to be lubricated
Understand the structure and operational principle of and either lubrication method are determined to use, and
the solenoid valve to secure safety. the operation should be accurately controlled.
The grade not less than Pneumatics techn i q u e Use additive-free turbine oil ISO VG32 for the lubricated
certification grade 2 is required. valve.
Intro
PV5G/CMF
PV5G-6
(DIN terminal box type)
PV5G-8
Pilot operated 5 port valve ISO conformed valve
CMF1
DIN terminal box type
CMF2
CMFZ
Technical data,
specifications
PV5-6R
C O N T E N T S
Discrete valve
PV5-8R
ISO size 2 (PV5G-8) 8
CMF1
ISO size 2 (CMF2) 20
CMF2
Manifold option 28
Technical data
(1) Type of manifold 29
CMFZ
Manifold specifications 30
Technical data,
specifications
Discrete valve ISO size 1
DIN terminal box type
Pilot operated 5 port valve ISO conformed valve
PV5G-6 Series
Applicable cylinder bore size: max. Φ100
(Subject: DC voltage)
PV5G-6 Series
Discrete valve; ISO size 1
Flow characteristics
PV5G-6
Port P → A/B A/B → R1/R2
Model no. Solenoid position
size C [dm3/(s·bar)] b C [dm3/(s·bar)] b
2-position single solenoid 6.1 0.28 6.7 0.20
2-position double solenoid 6.1 0.28 6.7 0.20
PV5G-8
3-position all ports closed 5.2 0.32 5.6 0.30
PV5G-6 Rc1/4
3-position A/B/R connection 5.1 0.32 6.9 0.16
3-position P/A/B connection 6.3 0.28 5.9 0.28
3-position all ports closed no leakage 3.4 - 3.0 -
CMF1
DIN terminal box type
Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 × C.
CMF2
Refer to the section D in "How to order" on Page 4 to select option "A".
CMFZ
Technical data,
specifications
PV5-6R
PV5-8R
CMF1
I/O connector type
CMF2
CMFZ
Technical data,
specifications
PV5G-6 Series
Discrete valve; ISO size 1
How to order DIN terminal box
ISO size 1
PV5G 6 FG-S 3 N A03
Model no.
ISO size 1
Model no.
Symbol Descriptions PV5G-6
A Solenoid position
A Solenoid position
FG-S 2-position single solenoid
FG-D 2-position double solenoid
FHG-D P 3-position all ports closed
pressurization
FJG-D type 3-position ABR connection
FIG-D 3-position PAB connection
FPG-D 3-position all ports closed
YZ-S Exhaust 2-position single solenoid
YZ-D pressurization type 2-position double solenoid
B Rated voltage
B Rated voltage
1 100 VAC
3 24 VDC
4 12 VDC
5 110 VAC
C Light and surge suppressor
C Light and surge
suppressor Blank None
N Light and surge suppressor Note 1
D Option
D Option
Blank None
Note on model no. selection A Coolant proof
Note 1: Refer to Intro 5 Page for the circuit diagram E Sub-plate and port size
of the type with light and surge suppressor. E Sub-plate and
port size Blank Without sub-plate
<Example of model number> A02 Side porting Rc1/4 (Rc3/8 for R port)
PV5G-6-FG-S-3-N-A03 A03 Side porting Rc3/8
Model: PV5G/ISO size 1 (DIN terminal box type) B02 Back porting Rc1/4 (Rc3/8 for R port )
A Solenoid position : P pressurization type B03 Back porting Rc3/8
2-position single solenoid
B Rated voltage : 24 VDC
C Power indicator light : Light and surge suppressor
D Option : None
E Sub-plate port size : Side porting Rc3/8
CB1 A02 Symbol Method P/A/B port R1/R2 port Weight (kg)
A Port connection
A Port connection
A02 Side Rc 1/4
Rc 3/8
A03 porting Rc 3/8
0.36
B02 Back Rc 1/4
Rc 3/8
B03 porting Rc 3/8
PV5G-6 Series
Discrete valve; ISO size 1
Internal structure and parts list: DIN terminal box type
PV5G-6
PV5G-6-FG-S PV5G-6-FG-D
2-position single solenoid
AB
2-position double solenoid
AB
a a b
R1 P R2 R1 P R2
PV5G-8
PV5G-6-YZ-S PV5G-6-YZ-D
2-position single solenoid exhaust pressurization 2-position double solenoid exhaust
type pressurization type
a AB AB
a b
CMF1
DIN terminal box type
R1 P R2 R1 P R2
6 8 10 5 3 4 15 2 1 9 12 7 13 6 8 10 5 3 4 15 2 1 12 13
CMF2
CMFZ
Technical data,
specifications
PV5G-6-FHG-D PV5G-6-FPG-D
PV5-6R
3-position all ports closed
A B
3-position all ports closed non-leak type
A B
a b a b
R1 P R2 R1 P R2
PV5G-6-FJG-D PV5G-6-FIG-D
PV5-8R
3-position A/B/R connection
AB
3-position P/A/B connection
AB
11 10 1 3 4 2 15 12 8 5 14 6 13
a b a b
R1 P R2 R1 P R2
CMF1
I/O connector type
11 10 2 3 1 4 15 12 8 5 13 6
CMF2
CMFZ
Technical data,
specifications
PV5G-6 Series
Discrete valve; ISO size 1
Dimensions: DIN terminal box type (without sub-plate)
PV5G-6-FG-S-* PV5G-6-FG-D-*
PV5G-6-YZ-S-* PV5G-6-YZ-D-*
2-position single solenoid 3
2-position double solenoid 3
38
28
38
28
11.5
18
11.5
18
Manual 38.4
.8 Manual
override
override
(40)
(40)
4 PF1/2
4 PF1/2
102.2
102.2
90.9
90.9
4.5
4.5
58
58
5.9
0.5
5.9
0.5
8.2
108
8.2
113.
4-M5x35
4-M5x35
PV5G-6-FHG-D-* PV5G-6-FPG-D-*
PV5G-6-FJG-D-* 3-position and non-leak type
PV5G-6-FIG-D-*
3
3-position
28
38
11.5
18
.8 Manual
override
(40)
4 PF1/2
102.2
90.9
4.5
58
40
5.9
0.5
8.2
128.2
4-M5x35
38 90 4-M5x5
PV5G-6 Series
Discrete valve; ISO size 1
Dimensions: DIN terminal box type (with sub-plate)
PV5G-6
PV5G-6-FG-S-*-* PV5G-6-FG-D-*-*
PV5G-6-YZ-S-*-* PV5G-6-YZ-D-*-*
108 113.7
56.9 56.9
2-position single solenoid 2-position double solenoid
PV5G-8
A B A B
38
38
R1 P R2 R1 P R2
11.5
11.5
38.4 Manual
76.8
CMF1
DIN terminal box type
Manual
override override
4 (40) 4 (40)
PF1/2 PF1/2
CMF2
139.7
139.7
128.4
128.4
102
102
95.5
95.5
CMFZ
31.1
37
31.1
37
22
22
14
14
13 13 2-Rc3/8: 5 (R1), 3 (R2) 13 13 2-Rc3/8: 5 (R1), 3 (R2)
Technical data,
specifications
25 25 3-Rc1/4, 3/8: 1 (P), 4 (A), 2 (B) 25 25 3-Rc1/4, 3/8: 1 (P), 4 (A), 2 (B)
1 (P) 1 (P)
5 (R1) 3 (R2) 5 (R1) 3 (R2)
2-Φ6.5 2-Φ6.5
50
62
50
62
PV5-6R
installation hole installation hole
PV5-8R
PV5G-6-FJG-D-*-*
PV5G-6-FIG-D-*-* 128.2
56.9
3-position A B Sub-plate dimensions (CB1-*)
2-RC1/4, 3/8
CMF1
26
14
R1 P R2
11.5
Pilot exhaust
76.8 Manual
override 2-RC1/8 prepared hole for
4-M5 tapping
CMF2
4 (40) 53
PF1/2 Depth 10
36 25
A B
9
62
28
50
CMFZ
R1 P R2
139.7
18 31
128.4
100
Technical data,
specifications
31.1
37
37
36
22
22
14
14
2-Φ6.5 26
installation hole 68
4 (A) 2 (B)
85
100
Discrete valve ISO size 2
DIN terminal box type
Pilot operated 5 port valve ISO conformed valve
PV5G-8 Series
Applicable cylinder bore size: max. Φ160
(Subject: DC voltage)
Electric specifications
3-position all ports closed
non-leak type (FPG) Descriptions
A B 100 (50/60Hz)
a b Rated voltage AC 110 (50/60Hz)
V
DC 12, 24
R1 P R 2
PV5G-8 Series
Discrete valve; ISO size 2
Flow characteristics
PV5G-6
Port P → A/B A/B → R1/R2
Model no. Solenoid position
size C [dm3/(s·bar)] b C [dm3/(s·bar)] b
2-position single solenoid 10.7 0.17 13.0 0.19
2-position double solenoid 10.7 0.17 13.0 0.19
PV5G-8
3-position all ports closed 10.0 0.16 11.0 0.25
PV5G-8 Rc3/8
3-position A/B/R connection 9.9 0.14 13.0 0.16
3-position P/A/B connection 11.0 0.12 12.0 0.21
3-position all ports closed no leakage 6.6 - 6.2 -
CMF1
DIN terminal box type
Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 × C.
CMF2
Refer to the section D in "How to order" on Page 10 to select option "A".
CMFZ
Technical data,
specifications
PV5-6R
PV5-8R
CMF1
I/O connector type
CMF2
CMFZ
Technical data,
specifications
PV5G-8 Series
Discrete valve; ISO size 2
How to order DIN terminal box
ISO size 2
PV5G 8 FG-S 3 N A03
Model no.
ISO size 2
Model no.
Symbol Descriptions PV5G-8
A Solenoid position
A Solenoid position
FG-S 2-position single solenoid
FG-D 2-position double solenoid
FHG-D P 3-position all ports closed
pressurization
FJG-D type 3-position ABR connection
FIG-D 3-position PAB connection
FPG-D 3-position all ports closed
YZ-S Exhaust 2-position single solenoid
YZ-D pressurization type 2-position double solenoid
B Voltage
B Voltage
1 100 VAC
3 24 VDC
4 12 VDC
5 110 VAC
C Light and surge suppressor
C Light and surge
suppressor Blank None
N Light and surge suppressor Note 1
D Option
D Option
Blank None
Note on model no. selection A Coolant proof
Note 1: Refer to Intro 5 Page for the circuit diagram E Sub-plate and port size
of the type with light and surge suppressor. E Sub-plate and
port size Blank Without sub-plate
<Example of model number> A03 Side porting Rc3/8 (Rc1/2 for R port)
PV5G-8-FG-S-3-N-A03 A04 Side porting Rc1/2
Model: PV5G/ISO size 2 (DIN terminal box type) A06 Side porting Rc3/4
A Solenoid position : P pressurization type B03 Back porting Rc3/8 (Rc1/2 for R port)
2-position single solenoid
B Rated voltage : 24 VDC
B04 Back porting Rc1/2
C Power indicator light : Light and surge suppressor B06 Back porting Rc3/4
D Option : None
E Sub-plate port size : Side porting Rc3/8
R port Rc1/2
CB2 A03 Symbol Method P/A/B port R1/R2 port Weight (kg)
A Port connection
A Port connection
A03 Rc 3/8 0.66
Side Rc 1/2
A04 Rc 1/2 0.64
porting
A06 Rc 3/4 Rc 3/4 1.40
B03 Rc 3/8 0.62
Back Rc 1/2
B04 Rc 1/2 0.61
porting
B06 Rc 3/4 Rc 3/4 1.40
10
PV5G-8 Series
Discrete valve; ISO size 2
Internal structure and parts list: DIN terminal box type
PV5G-6
PV5G-8-FG-S PV5G-8-FG-D
2-position single solenoid
AB
2-position double solenoid
AB
a a b
R1 P R2 R1 P R2
PV5G-8
PV5G-8-YZ-S PV5G-8-YZ-D
2-position single solenoid 2-position double solenoid
exhaust pressurization type exhaust pressurization type
a AB AB
a b
CMF1
DIN terminal box type
R1 P R2 R1 P R2
6 8 10 5 3 4 15 2 1 12 9 7 13 6 8 10 5 3 4 15 2 1 12 13
CMF2
CMFZ
Technical data,
specifications
PV5G-8-FHG-D PV5G-8-FPG-D
PV5-6R
3-position all ports closed
A B
3-position all ports closed non-leak type
A B
a b a b
R1 P R2 R1 P R2
PV5G-8-FJG-D PV5G-8-FIG-D
PV5-8R
3-position A/B/R connection
AB
3-position P/A/B connection
AB
11 10 3 4 1 2 15 12 14 8 5 6 13
a b a b
R1 P R2 R1 P R2
CMF1
I/O connector type
11 10 3 4 1 2 15 12 13 8 5 6
CMF2
CMFZ
Technical data,
specifications
11
PV5G-8 Series
Discrete valve; ISO size 2
Dimensions: DIN terminal box type (without sub-plate)
PV5G-8-FG-S-* PV5G-8-FG-D-*
PV5G-8-YZ-S-* 48
PV5G-8-YZ-D-* 48
2-position single solenoid 2-position double solenoid
38
50
38
50
11.5
11.5
24 24 Manual
Manual override
override 52.8 105.6
102.2
102.2
90.9
90.9
64.5
64.5
58
58
11
11
0.5
0.5
72.8 72.8
140.6 145.6
4-M6x45 4-M6x45
PV5G-8-FHG-D-* PV5G-8-FPG-D-*
PV5G-8-FJG-D-* 3-position and non-leak type
PV5G-8-FIG-D-*
3-position 48
38
50
11.5
24 Manual
override
105.6
4 PF1/2 (40)
102.2
90.9
64.5
58
11
0.5
72.8
60
162.6
4-M6x45
4-M6x105
50 110
12
PV5G-8 Series
Discrete valve; ISO size 2
Dimensions: DIN terminal box type (with sub-plate)
PV5G-6
PV5G-8-FG-S-*-* PV5G-8-FG-D-*-* 72.8
145.6
140.6
PV5G-8-YZ-S-*-* 72.8 PV5G-8-YZ-D-*-*
2-position double solenoid
A B
A B
PV5G-8
50
50
11.5
R1 P R2
11.5
R1 P R2 Manual
105.6 override
Manual 52.8 4 (40)
override PF1/2
CMF1
DIN terminal box type
4 PF1/2 (40)
CMF2
154.1
142.8
154.1
142.8
116.4
109.9
116.4
109.9
51.4
42.1
32.1
CMFZ
51.4
22.1
42.1
32.1
22.1
Technical data,
specifications
1 (P)
5 (R1) 3 (R2)
1 (P)
5 (R1) 3 (R2)
62
75
62
75
PV5-6R
(Note: Refer to below table for (Note: Refer to below table for 4 (A) 2 (B)
A A 98
CB2-B 06 dimensions.) 4 (A) 2 (B) CB2-B 06 dimensions.)
98 112
112
PV5G-8-FHG-D-*-*
PV5G-8-FJG-D-*-*
PV5-8R
162.6
PV5G-8-FIG-D-*-* 72.8
CMF1
50
no. B 03
A
B 04
A
B 06
A
A 32 40
11.5
R1 P R2
Pilot exhaust B 3/8 1/2 3/4
Manual 105.6 4-M6 2-RC1/8 prepared hole
for tapping C 98 128
4 override (40) 68 Depth 12
PF1/2 48 H D 112 142
E 62 72 CMF2
A B
F 75 86
X
10
E
38
G 6.5 7.5
R1 P
R2
H 38 53
24 J
CMFZ
J 42 55
C 2-ΦG installation hole
154.1
142.8
D K 62 84
116.4
109.9
L 32 42
M 50 62
N
M
Technical data,
specifications
L
Y
51.4
N 51 63
42.1
32.1
R CP K
22.1
S 32 40
1 (P)
5 (R1) 3 (R2)
T 88 116
S U 10 11
T V 12 16
62
75
2-Φ6.5
W 18 22
installation hole
X 18 23
4 (A) 2 (B) Y 22 30
(Note: Refer to right table for
A
CB2-B 06 dimensions.) 98
112
13
Individual wiring type manifold ISO size 1
DIN terminal box type
Pilot operated 5 port valve ISO conformed valve
CMF1 Series
Applicable cylinder bore size: max. Φ100
Common specifications
Descriptions
Manifold type Manifold integrated
Common supply, common exhaust common supply and individual exhaust
Type of manifold Individual supply, common exhaust individual supply and individual exhaust
Multi-pressure air supply
Station number 1 to 10 stations
Type of valve and operator type Pilot operated soft spool valve
Working fluid Compressed air
Max. working pressure MPa 1.0
Min. working pressure MPa 0.15, 0.20 (3-position) Note 1
Withstanding pressure MPa 1.50
Ambient temperature °C -5 to 60 (to be unfrozen)
Fluid temperature °C 5 to 60
Lubrication Not required
Protective structure Dust proof and jet-proof (IP65 structure)
Leakage cm3/min 10 (ANR) or less
(A, B → R port) Only 3-position all ports closed non-leak type 0.3 (ANR) or less Note 2
Vibration/shock m/s2 50 or less/300 or less
Working environment Use in the environment containing corrosive gas is not permissible.
Note 1: For YZ-S only, use supply pressure at R1>R2≥0.1 MPa.
Note 2: The default is indicated.
Electric specifications
Descriptions
100 (50/60Hz)
Rated voltage AC 110 (50/60Hz)
V
DC 12, 24
Rated voltage fluctuation range ±10%
Without light With light
Individual specifications
Descriptions CMF1
Port size P/R1/R2 port Rc3/8, Rc1/2
Note 1 A/B port Rc3/8 Rc3/4
Single solenoid 30 (when turned ON) and 40 (when turned OFF)
Response 2-position
time Double solenoid 30
ms
Note 2
3-position 30 (when turned ON) and 60 (neutral)
Note 1: The piping port screw is compatible with G and NPT screws. Contact CKD for details.
Note 2: The response time is the value at supply pressure of 0.5 MPa, oilless. This may change depending on the pressure and type of oil supplied.
14
CMF1 Series
Individual wiring type manifold; ISO size 1
Flow characteristics
PV5G-6
Port P → A/B A/B → R1/R2
Model no. Solenoid position
size C [dm3/(s·bar)] b C [dm3/(s·bar)] b
2-position single solenoid 4.8 0.25 5.2 0.26
2-position double solenoid 4.8 0.25 5.2 0.26
PV5G-8
3-position all ports closed 4.4 0.27 4.7 0.27
CMF1 Rc1/4
3-position A/B/R connection 4.4 0.25 5.3 0.25
3-position P/A/B connection 4.8 0.27 4.7 0.27
3-position all ports closed no leakage 3.2 - 2.8 -
CMF1
DIN terminal box type
Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 × C.
CMF2
Control unit component Descriptions Descriptions
Air filter (with automatic drain/manual drain) Filtration rating 5μm
Setting pressure (secondary pressure) 0.1 to 0.83MPa
Regulator
Pressure adjusting range 0.1 to 0.8MPa
CMFZ
Contact configuration 1C
Pressure switch
Rated current (inductive load) 125 VAC 15A and 250 VAC 15A
Air release valve (only single) Working pressure range 0.15 to 1.0MPa
Technical data,
specifications
Refer to pneumatic/vacuum/auxiliary components catalog (No. CB-024SA) for specifications of pressure switch APE-8F-*.
PV5G-6-FG-S-*-N is used for air release valve.
PV5-6R
PV5-8R
CMF1
I/O connector type
CMF2
CMFZ
Technical data,
specifications
15
CMF1 Series
Individual wiring type manifold; ISO size 1
How to order DIN terminal box type (without control unit)
ISO size 1
CMF 1 5 02 L HY1 B DU SB
Model no.
Symbol Descriptions CMF1
Model no. A Station number
A Station
number 1 1 station
to to
10 10 stations
A
B
R1 P R2
D side (bottom)
16
CMF1Series
Individual wiring type manifold; ISO size 1
How to order DIN terminal box type (with control unit)
ISO size 1
PV5G-6
Model no.
CMF 1 5 02 L A HY1 B DU 1 Symbol Descriptions CMF1
A Station number
Station
PV5G-8
A
Model no. 3 3 stations
number
Note 1 to to
10 10 stations
CMF1
DIN terminal box type
B A/B port size
Note 2 02 Rc 1/4
03 Rc 3/8
HX1 Rc1/4, Rc3/8 mix
CMF2
C A/B port position
C A/B port position
Note 3 Blank Right side
L Left and right sides
H Left side
CMFZ
D Control unit
Note 4,
Z Rear side
Note 5 T Flexible selection (plug attached)
Control unit
Technical data,
D Reg. : Regulator, Air : Air release valve, Pre : Pressure switch
specifications
A Filter with auto drain Reg. Air
AP Filter with auto drain Reg. Air Pre
Note on model no. selection M Filter with manual drain Reg. Air
MP Filter with manual drain Reg. Air Pre
PV5-6R
Note 1: This is the station number including 2 stations of unit base.
Note 2: HX indicates mix of port size. Contact CKD for details. Filter with auto drain
F
(air release valve plug)
Reg.
Note 3: C indicates port position.
Ports will be plugged unless indicated. Filter with manual drain
Note 4: The pressure switch has no indicator light. (Indicator light
G
(air release valve plug)
Reg.
is available as custom order.)
PV5-8R
Note 5: Air release valve has light, surge suppressor and manual
C With air release valve Air
override. E R port size
Note 6: Instruction of F indicates the port position. E R port size
The opposite side of indicated port will be plugged.
03 Rc 3/8
04 Rc 1/2
CMF1
<Example of model number>
17
CMF1 Series
Individual wiring type manifold; ISO size 1
Dimensions: DIN terminal box type
CMF1 P/R port size A B
Rc 3/8 21 30
Common exhaust L2 (43n + 64)
Rc 1/2 26 26
L1 (43n + 43)
4-M5 depth 9 51
R side
2-Rc 1/8 45
Pilot exhaust port B
24 24
A A
U side D side
120
U
95
36
18
P
56.9
R
11.5
14.5 (3-posi.)
3
-Rc 3/8,1/2
4-(9 × 11) L side 6
installation hole
56 (silencer box)
202.7
2n
4n -Rc 1/4, 3/8
162.7
151.4
B B B B B B B
60
45
45
19
A A A A A A A
32
43 43
CMF1
Individual exhaust 4
2n
-Rc 1/4, 3/8
181.4
4n
75.5
60
B B B B B B B
45
45
19
A A A A A A A
32 43 43
L side
CMF1
2n-Rc1/4, 3/8
Back porting 3
6 -Rc 3/8,1/2
A A A A A A A
R
24 24
15 22
A A
U side
120
D side
95
B B B B B B B
R
B 2-Rc 1/8
8 8 Pilot exhaust port
43 43 45
4-(9 × 11) installation hole
51
L1 (43n + 43)
L2 (43n + 64)
R side
18
CMF1Series
Individual wiring type manifold; ISO size 1
Dimensions: DIN terminal box type
PV5G-6
With control unit P/R port size
Rc 3/8
A
21
B
30
32 Rc 1/2 26 26
R side
2
Pressure switch 4 -Rc 3/8,1/2
PV5G-8
97
R
24 24
A A
120
U side
U
D side
95
R
125
CMF1
DIN terminal box type
B
L side 2-Rc 1/8 45
4-(9 × 11) installation hole Pilot exhaust port 51
JIS symbol
CMF2
R P R2
B
1
A
Individual supply spacer
CMF1-P-*
CMFZ
B P
2n
-Rc 1/4, 3/8 A
194
4n
FR installation spacer
FRB
125
Air release valve
Technical data,
specifications
PV5G-6-FG-S-*-N
60
B B B B B B B
45
45
Pressure switch
19
A A A A A A A
APE-8F-*
Filter and regulator unit
43 43 43
L1 (43n + 43) R1 P R2 OUT P1
PV5-6R
How to order
Spacer type regulator
PV5-8R
CMF 1 SR A T05 C
CMF1
1 P P port MPa display Blank
CMF1-SR-P-T05 CMF1-SR-A-T05C
CMFZ
CMF1-SR-B-T05C
Spacer type regulator JIS symbol JIS symbol
Technical data,
specifications
CMF1-SR-P-T05 CMF1-SR-A-T05C
a AB A
R1 R2
Pressure
Pressure adjustment knob adjustment knob B
a
P R1 P R2
41.5
41.5
CMF1-SR-B-T05C
B
41 41
3
3
120 At adjusting pressure 120
A At adjusting pressure
238 a
238
R 1 P R2
19
Individual wiring type manifold ISO size 2
DIN terminal box type
Pilot operated 5 port valve ISO conformed valve
CMF2 Series
Applicable cylinder bore size: max. Φ160
Common specifications
Descriptions
Manifold type Manifold integrated
Common supply, common exhaust common supply and individual exhaust
Type of manifold Individual supply, common exhaust individual supply and individual exhaust
Multi-pressure air supply
Station number 1 to 10 stations
Type of valve and operator type Pilot operated soft spool valve
Working fluid Compressed air
Max. working pressure MPa 1.0
Min. working pressure MPa 0.15 0.20 (3-position) Note 1
Withstanding pressure MPa 1.50
Ambient temperature °C -5 to 60 (to be unfrozen)
Fluid temperature °C 5 to 60
Lubrication Not required
Protective structure Dust proof and jet-proof (IP65 structure)
Leakage cm3/min 10 (ANR) or less
(A, B → R port) Only 3-position all ports closed non-leak type 0.3 (ANR) or less Note 2
Vibration/shock m/s2 50 or less/300 or less
Working environment Use in the environment containing corrosive gas is not permissible.
Note 1: For YZ-S only, use supply pressure at R1>R2≥0.1 MPa.
Note 2: The default is indicated.
Electric specifications
Descriptions
100 (50/60Hz)
Rated voltage AC 110 (50/60Hz)
V
DC 12, 24
Rated voltage fluctuation range ±10%
Without light With light
Individual specifications
Descriptions CMF2
Port size P/R1/R2 port Rc3/8, Rc1/2
Note 1 A/B port Rc3/8 Rc3/4
Single solenoid 40 (when turned ON), 60 (when turned OFF)
Response 2-position
time Double solenoid 40
ms
Note 2
3-position 40 (when turned ON), 60 (neutral)
Note 1: The piping port screw is compatible with G and NPT screws. Contact CKD for details.
Note 2: The response time is the value at supply pressure of 0.5 MPa, oilless. This may change depending on the pressure and type of oil supplied.
20
CMF2 Series
Individual wiring type manifold; ISO size 2
Flow characteristics
PV5G-6
Port P → A/B A/B → R1/R2
Model no. Solenoid position
size C [dm3/(s·bar)] b C [dm3/(s·bar)] b
2-position single solenoid 9.7 0.12 11.0 0.14
2-position double solenoid 9.7 0.12 11.0 0.14
PV5G-8
3-position all ports closed 9.2 0.12 10.1 0.15
CMF2 Rc3/8
3-position A/B/R connection 9.2 0.11 11.6 0.11
3-position P/A/B connection 9.6 0.11 10.2 0.18
3-position all ports closed no leakage 6.2 - 5.9 -
CMF1
DIN terminal box type
Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 × C.
CMF2
CMFZ
Technical data,
specifications
PV5-6R
PV5-8R
CMF1
I/O connector type
CMF2
CMFZ
Technical data,
specifications
21
CMF2 Series
Individual wiring type manifold; ISO size 2
How to order DIN terminal box
ISO size 2
CMF 2 5 03 L 04 B SB
Model no.
Symbol Descriptions CMF2
Model no. A Station number
A Station
number 1 1 station
to to
10 10 stations
A
B
R1 P R2
D side (bottom)
22
MEMO
23
I/O connector type DIN terminal box type
Technical data, CMFZ CMF2 CMF1 PV5-8R PV5-6R Technical data, CMFZ CMF2 CMF1 PV5G-8 PV5G-6
specifications specifications
CMF2 Series
Individual wiring type manifold; ISO size 2
Dimensions: DIN terminal box type
CMF2 P/R port size A B
Rc 1/2 30 32
Common exhaust Rc 3/4 37 25
L2 (56n + 74)
L1 (56n + 54)
61
4n-M6 depth 12 50
R side 2-Rc 1/8
38 Pilot exhaust port B
162.6 (3-position)
97 (silencer box)
33
A
R
D side
160
144
120
U side
24
48
33
R
A
72.8
11.5
3
4-(11 × 13) 6 -Rc 1/2, 3/4
L side
installation hole
232.7
4n -Rc 3/8,1/2
172.7
161.4
B B B B B B B
70
54
45
22
A A A A A A A
37 2.5 2.5
56 56
CMF2
Individual exhaust
4
Individual supply spacer
Individual exhaust spacer
Exhaust pressurization individual exhaust spacer
272.7
2n
4n -Rc 3/8,1/2
212.7
201.4
88
B B B B B B B
70
54
45
22
A A A A A A A
37 2.5 2.5
56 56
CMF2
L side
Back porting 2-Rc 3/8,1/2
A A A A A A A
25 35
33
A
R
120
144
160
U side D side
P
33
R
A
B B B B B B B
2-Rc 1/8
10 10 B Pilot exhaust port
55 56 50
4-(11 × 13) installation hole
L1 (56n + 54) 61
L2 (56n + 74) 70
R side
24
CMF2 Series
Individual wiring type manifold; ISO size 2
How to order
Spacer type regulator
PV5G-6
CMF 2 SR A T05 C
PV5G-8
A Size B Decompression port position C Pressure gauge D Check valve
2 ISO size 2 P P port MPa display Blank No
T05
(With limit mark)
A A port C Yes
B B port
CMF1
DIN terminal box type
Indicate "no check
valve" (blank) for
SR-P, and "with
check valve" (C) for
SR-A and SR-B.
CMF2
*Note that the pressure gauge direction differs for the CMF2-SR-A-T05C.
CMFZ
CMF2-SR-P-T05 JIS symbol CMF2-SR-A-T05C JIS symbol
CMF2-SR-A-T05C
Technical data,
CMF2-SR-B-T05C CMF2-SR-P-T05
specifications
AB A
a b
P R1 P R2
PV5-6R
CMF2-SR-B-T05C
55.5
55.5
53 53
PV5-8R
a A b
159 159
303
303
R 1 P R2
CMF1
I/O connector type
CMF2
CMFZ
Technical data,
specifications
25
CMFZ Series
Mix manifold; ISO size 1, 2 mix
How to order DIN terminal box
CMFZ 5 HX3 L HY3 B DU
Quantity
of size 1 Model no.
Quantity Symbol Descriptions CMFZ
of size 2
A Station number
A Station
number 2 2 stations
to to
ISO size 1, 2
mix manifold 10 10 stations
U side size 1
D side size 2
CMFBZ-00L
With connecting bracket
and O ring
ISO size 1, 2
1 Mix
Block
U side size 2
D side size 1
CMFBZ-00R
With connecting bracket
and O ring
26
CMFZ
Series
Mix manifold; ISO size 1, 2; appearance image
Mix manifold appearance image
PV5G-6
30
PV5G-8
U side D side
D
U
CMF1
DIN terminal box type
Size 1 foot
Size 2 foot
(FB1-04)
(FB2-06)
CMF2
Size 1 block
Size 2 block
(CMFB1-02L)
(CMFB2-03L)
CMFZ
Mix blocks
(CMFBZ-00R)
Technical data,
specifications
70
B B
60
B B
A A A A
PV5-6R
30
PV5-8R
U side D side
U
CMF1
Size 1 foot I/O connector type
CMF2
Size 2 foot
(FB1-04)
(FB2-06)
Size 1 block Size 2 block
(CMFB1-02L) (CMFB2-03L)
CMFZ
Mix blocks
(CMFBZ-00L)
Technical data,
specifications
70
B B
B B
60
A A A A
27
CMF1/2 Series
Manifold option
Model no.
Options Remarks
ISO size 1 ISO size 2
1. Individual supply spacer 1. Clamp for individual
supply port, used for
R1 A P B R2 CMF1-P-02 ( Rc1/4 ) CMF2-P-03 ( Rc3/8 )
P multi-pressure
P 03 ( Rc3/8 ) 04 ( Rc1/2 )
2. Individual exhaust for
exhaust pressurization
4. Masking plate
PV5G-6
CM1-00 CM2-00 PV5G-8
Discrete masking plate
5. Base gasket
PV5G-6
PV5G-6-BASE-GASKET PV5G-8-BASE-GASKET
PV5G-8
6. Set screw
CMF1-M5X35 CMF2-M6X45
28
CMF1/2 Series
Technical data (1) Type of manifold
Type of manifold
A wide range of air supply, exhaust, and piping combinations is available.
PV5G-6
Select the functions best suited to your application.
General use Special use (exhaust pressurization) Common descriptions for general and special purpose
Common exhaust method This is suitable for supplying more than one Back porting method
different pressure to one manifold.
PV5G-8
This is the most commonly used method. If side porting is not possible, pipes can be
Each solenoid valve air supply and exhaust Example: To drive two piston cylinders connected from either the A or B port, or all
are grouped at one position with P (air supply) used in a welding machine. pipes can be connected from the bottom of
and R (exhaust) ports passing through the Central method the manifold.
connected manifold block.
CMF1
DIN terminal box type
Exhaust
Air supply
Exhaust
CMF2
Air supply pressurization type
CMFZ
R1 and 2 (exhaust) ports are independent for
Exhaust pressurization type
each solenoid valve, so the adjacent cylinder Solenoid valve
will not pop out because of back pressure.
Technical data,
specifications
An individual exhaust spacer (CMF1-R-*) can
be inserted between the manifold block and
valve to enable individual exhaust. R2
Individual exhaust P
spacer CMF1-R-*
PV5-6R
R1
B A B A B A
Exhaust
Air supply
Manifold
PV5-8R
Individual supply method
P (air supply) ports are independent for each
Φ25
CMF1
I/O connector type
inserted between the manifold block and valve Gland gasket □ 27.5
to enable individual air supply. 31.3
Air supply
CMFZ
Exhaust
and R (exhaust) port are to be used only for Pin No. Name
specific valves in the manifold. 1 a SOL
Example: When using an oilless manifold but
1 2 2 b SOL
lubricating a specific valve.
Individual supply (CMF1-P-*) and exhaust 3 3 COM
(CMF1-R-*) spacers inserted between the
manifold block and valve enable individual air No polarity is designated when DC power is used.
29
CMF1 Series
Manifold specifications Issue / /
CMF 1
A B
- C D
- E F G
- H
- - I J K
Station number A/B port position P/R port position Silencer box Indicator light
ISO size A/B port size P/R port size HY configuration Voltage Option
A ISO size B Station No. C A/B port size D A/B port position E P/R port size F P/R port position G HY configuration H Silencer box I Voltage
1 PV5G-6 1 1 station 02 Rc 1/4 Blank Right side 03 Rc 3/8 B Top and bottom Blank None 1 100 VAC
Blank Other than HY is
to to 03 Rc 3/8 L Left/right sides 04 Rc 1/2 D Bottom selected for E . SB Selected (D side) 3 24 VDC
10 10 stations HX1 Rc1/4 ,Rc 3/8 mix H Left side HY1 Rc3/8 ,Rc 1/2 mix U Top Rc /8 is bottom,
3
4 12 VDC
DU
Z Rear side E P top, R bottom Rc 1/2 is top 5 110 VAC
T Plug attached F P bottom, R top Rc 3/8 is top,
UD
U side (top) T Plug attached Rc 1/2 is bottom
R1 P R2
(4)
Indicate left solenoid valve No. (1) to (9) in the following solenoid valve No. field
when placing an order.
A To select an option, circle the field for the relevant option below.
(5)
B
Station number No 1 2 3 4 5 6 7 8 9 10
Solenoid valve
type No PV5G-6
R1 P R2
D side (bottom)
Plug position should be R
indicated when L is
Solenoid valve type No. selected in D L
AB
a
2-position Air supply spacer
PV5G-6-FG-S (1)
single solenoid R1 P R2 Exhaust spacer
2-position a
AB
b Pilot check valve
PV5G-6-FG-D (2)
double solenoid CMF*-SR-P
R1 P R 2 Spacer type
Option
3-position AB CMF*-SR-A
a b regulator
all ports PV5G-6-FHG-D (3) CMF*-SR-B
block R1 P R 2
Flow Air supply passage shut off
3-position a
AB
b
path
shut
A-B-R PV5G-6-FJG-D (4) off plate Exhaust passage shut off
connection R1 P R 2
A mixed bore size should 02
3-position a
AB
b be indicated when HX is
P-A-B PV5G-6-FIG-D (5) selected for C . 03
connection R 1P R 2
A B
3-position all ports a b
a AB
2-position single solenoid
Exhaust pressurization PV5G-6-YZ-S (7)
R 1 PR 2
AB
2-position double solenoid a b Option (spacer) assembly order
Exhaust pressurization PV5G-6-YZ-D (8) Note: The basic order from the
R 1 PR 2 Solenoid valve
sub-base to the solenoid valve is
Regulator shown at left. When not using
Masking plate CM1-00 (9) spacers, simply stack up parts
Air supply and
exhaust excluding those parts.
Pilot check valve
Sub-base
30
CMF1 Series
Manifold specifications Issue / /
PV5G-6
Contact
●Contact ●Quantity set ●Request date / /
Slip No. Order No. Order No.
PV5G-8
●Manifold model no.
CMF 1
A B
- C D
- - E F G H
- - I J K
CMF1
DIN terminal box type
ISO size A/B port size Control unit R port position Voltage Option
Station number A/B port position R port HY configuration Indicator light
B Station No. C A/B port size D A/B port position E Control unit (option) F R port G R port position H HY configuration
CMF2
A ISO size
1 PV5G-6 3 3 stations 02 Rc1/4 Blank Right side A Filter regulator with auto drain/air release valve 03 Rc3/8 B R on top or at bottom Other than HY is
Blank
to to 03 Rc3/8 L Left/right sides AP Filter regulator with auto drain, air release valve/pressure switch 04 Rc1/2 D R at bottom selected for F .
10 10 stations HX1 Rc1/4, Rc3/8 mix H Left side M Filter with manual drain regulator/air release valve HY1 Rc3/8, Rc1/2 mix U R on top Rc 3/8 is bottom,
DU
Note: When using the control unit, select a number Z Rear side MP Filter with manual drain regulator, air release valve/pressure switch T Plug attached Rc 1/2 is top
of stations including two for the unit base. T Plug attached F Filter regulator with auto drain (air release valve plug) Rc 3/8 is top,
UD
G Filter with manual drain regulator (air release valve plug) Rc 1/2 is bottom
CMFZ
U side (top)
R1 R2 C Air release valve
Note: The air release valve with the I Voltage J Indicator light K Option
control unit has light and surge 1 100 VAC Blank None Blank None
A 3 24 VDC N Indicator light A Coolant proof
(5) suppressor and manual override.
B 4 12 VDC
Technical data,
specifications
(4) 5 110 VAC
L side (left) R side (right) Station number No.
(3)
Note: I , J , and K are installation
PV5-6R
P
Control unit when placing an order.
To select an option, circle the field for the relevant option below.
Use vertical with the
filter facing down. Station number No 1 2 3 4 5 6 7 8 9 10
Solenoid valve
D side (bottom) type No PV5G-6
PV5-8R
Plug position should be R
Solenoid valve type No. indicated when L is
a
AB selected in D L
2-position
PV5G-6-FG-S (1) Air supply spacer
single solenoid R1 P R2
AB
Exhaust spacer
CMF1
2-position a b
3-position a
AB
b Flow Air supply passage shut off
A-B-R PV5G-6-FJG-D (4) path
shut
connection R1 P R 2 Exhaust passage shut off
off plate
3-position a
AB
b
A mixed bore size should 02
P-A-B PV5G-6-FIG-D (5) be indicated when HX is
CMFZ
connection R 1P R 2
selected for B . 03
A B
3-position all ports a b
R1 P R
specifications
a AB
2-position single solenoid
PV5G-6-YZ-S (7)
Exhaust pressurization
R 1 PR 2
Option (spacer) assembly order
AB
a b
2-position double solenoid Note: The basic order from the
PV5G-6-YZ-D (8)
Exhaust pressurization R 1 PR 2
Solenoid valve sub-base to the solenoid valve is
shown at left. When not using
Regulator spacers, simply stack up parts
Masking plate CM1-00 (9) Air supply and excluding those parts.
exhaust
Pilot check valve
Sub-base
31
CMF2 Series
Manifold specifications Issue / /
CMF 2
A B
- C D
- E F G
- H
- - I J K
Station number A/B port position P/R port position Silencer box Indicator light
ISO size A/B port size P/R port size HY configuration Voltage Option
A ISO size B Station No. C A/B port size D A/B port position E P/R port size F P/R port position G HY configuration H Silencer box I Voltage
2 PV5G-8 1 1 station 03 Rc 3/8 Blank Right side 04 Rc 1/2 B Top and bottom Blank None 1 100 VAC
Blank Other than HY is
to to 04 Rc 1/2 L Left/right sides 06 Rc 3/4 D Bottom selected for E . SB Selected (D side) 3 24 VDC
10 10 stations HX2 Rc 3/8 /Rc 1/2 mix H Left side HY2 Rc 1/2 /Rc 3/8 mix U Top Rc /2 is bottom,
1
4 12 VDC
DU
Z Rear side E P top, R bottom Rc 3/4 is top 5 110 VAC
T Plug attached F P bottom, R top Rc 1/2 is top,
UD
U side (top) T Plug attached Rc 3/4 is bottom
R1 P R2
(4) Indicate left solenoid valve No. (1) to (9) in the following solenoid valve No. field
when placing an order.
A To select an option, circle the field for the relevant option below.
(5)
B
Station number No 1 2 3 4 5 6 7 8 9 10
Solenoid valve
type No PV5G-8
R1 P R2
D side (bottom)
Plug position should be R
indicated when L is
Solenoid valve type No. selected in D L
AB
a
2-position Air supply spacer
PV5G-8-FG-S (1)
single solenoid R1 P R2 Exhaust spacer
2-position a
AB
b Pilot check valve
PV5G-8-FG-D (2)
double solenoid CMF*-SR-P
R1 P R 2 Spacer type
Option
3-position AB CMF*-SR-A
a b regulator
all ports PV5G-8-FHG-D (3) CMF*-SR-B
block R1 P R 2
Flow
Air supply passage shut off
3-position a
AB
b
path
shut
A-B-R PV5G-8-FJG-D (4) off plate Exhaust passage shut off
connection R1 P R 2
A mixed bore size should 03
3-position a
AB
b
be indicated when HX is
P-A-B PV5G-8-FIG-D (5) selected for C . 04
connection R 1P R 2
A B
3-position all ports a b
a AB
2-position single solenoid
PV5G-8-YZ-S (7)
Exhaust pressurization
R 1 PR 2
a
AB
b
Option (spacer) assembly order
2-position double solenoid
PV5G-8-YZ-D (8) Note: The basic order from the
Exhaust pressurization Solenoid valve
R 1 PR 2 sub-base to the solenoid valve is
shown at left. When not using
Regulator
Masking plate CM2-00 (9) spacers, simply stack up parts
Air supply and excluding those parts.
exhaust
Pilot check valve
Sub-base
32
CMFZ Series
Manifold specifications Issue / /
PV5G-6
ISO size 1, 2 mix DIN terminal box type Your company name
●Contact ●Quantity set ●Request date / / Contact
Slip No. Order No. Order No.
PV5G-8
●Manifold model no.
CMF Z - - - -
CMF1
DIN terminal box type
A B C D E F G H I J
Station number A/B port position P/R port position Voltage Option
ISO size A/B port size P/R port size Configuration of HY Indicator light
CMF2
A ISO size B Station No. C A/B port size D A/B port position E P/R port size F P/R port position G Configuration of HY H Voltage I Indicator light
Z Mix of size 1, 2 1 1 station HX3 1:02 · 2:03 Blank Right side HY3 1:03 · 2:04 B Top and bottom Size 1 is bottom, 1 100 VAC Blank None
DU
to to HX4 1:02 · 2:04 L Left/right sides HY4 1:03 · 2:06 D Bottom Size 2 is top 3 24 VDC N Indicator light
10 10 stations HX5 1:03 · 2:03 H Left side HY5 1:04 · 2:04 U Top Size 1 is top, 4 12 VDC
UD
HX6 1:03 · 2:04 Z Rear side HY6 1:04 · 2:06 E P top, R bottom Size 2 is bottom 5 110 VAC
CMFZ
T Plug attached F P bottom, R top
U side (top) T Plug attached
R1 P R2
J Option
Blank None
Technical data,
specifications
(1) A Coolant proof
Note: H , I , and J are installation
(2) valve options selected when
L side (left) R side (right) assembling the manifold.
(3) Station number No.
(4) Indicate left solenoid valve No. (1) to (9) in the following solenoid valve No. field
PV5-6R
when placing an order.
A To select an option, circle the field for the relevant option below.
(5)
B
Station number No 1 2 3 4 5 6 7 8 9 10
Solenoid PV5G-6
R1 P R2
D side (bottom) valve
PV5-8R
type No PV5G-8
Solenoid valve type No. Plug position should be R
AB indicated when L is
a
2-position selected in D L
PV5G-*-FG-S (1)
single solenoid R1 P R2 Air supply spacer
CMF1
2-position
AB
Exhaust spacer
3-position AB CMF*-SR-P
a b Spacer type
all ports PV5G-*-FHG-D (3) CMF*-SR-A
Option
CMF2
block R1 P R 2 regulator
CMF*-SR-B
3-position a
AB
b
A-B-R PV5G-*-FJG-D (4) Flow
path Air supply passage shut off
connection R1 P R 2
shut
off plate Exhaust passage shut off
3-position a
AB
b
CMFZ
R1 P R 2
a AB
2-position single solenoid
PV5G-*-YZ-S (7)
Exhaust pressurization
R 1 PR 2
AB
2-position double solenoid a b Option (spacer) assembly order
PV5G-*-YZ-D (8) Note: The basic order from the
Exhaust pressurization R 1 PR 2 Solenoid valve
sub-base to the solenoid valve is
Regulator shown at left. When not using
Masking plate CM*-00 (9) spacers, simply stack up parts
Air supply and
exhaust
excluding those parts.
33
MEMO
34
PV5/CMF
PV5G-6
(I/O connector type)
PV5G-8
Pilot operated 5 port valve ISO conformed valve
CMF1
DIN terminal box type
CMF2
CMFZ
Technical data,
specifications
PV5-6R
C O N T E N T S
Discrete valve
PV5-8R
ISO size 2 (PV5-8R) 42
CMF1
ISO size 2 (CMF2) 54
CMF2
Manifold option 60
Technical data
(1) Type of manifold 61
CMFZ
Manifold specifications 62
Technical data,
specifications
35
Discrete valve ISO size 1
I/O connector type
Pilot operated 5 port valve ISO conformed valve
PV5-6R Series
Applicable cylinder bore size: max. Φ100
R1 P R 2
Individual specifications
Descriptions PV5-6R
3-position A/B/R Port size Note 1 Rc1/4 Rc3/8
connection (FJG) Response time Single solenoid 30 (when turned ON) and 40 (when turned OFF)
2-position
AB ms Double solenoid 30
a b Note 2 3-position 30 (when turned ON) and 50 (neutral)
R1 P R
Single solenoid 0.40
2
Weight 2-position
Double solenoid 0.44
kg
Other than non-leak type 0.46
3-position P/A/B Note 3 3-position
All ports closed non-leak type 1.12
connection (FIG)
Note 1: G and NPT threads are available for piping port, so please consult with CKD.
AB Note 2: Response time is the value at supply pressure of 0.5 Mpa, oilless. This may change depending on the pressure and type of oil supplied.
a b
Note 3: The value is the weight without sub-plate.
R 1P R 2 Flow characteristics
P → A/B A/B → R1/R2
Port
Model no. Solenoid position C C
size b b
[dm3/(s·bar)] [dm3/(s·bar)]
2-position single solenoid 6.1 0.28 6.7 0.20
2-position double solenoid 6.1 0.28 6.7 0.20
3-position all ports closed 5.2 0.32 5.6 0.30
PV5-6R Rc1/4
3-position A/B/R connection 5.1 0.32 6.9 0.16
3-position P/A/B connection 6.3 0.28 5.9 0.28
3-position all ports closed no leakage 3.4 - 3.0 -
Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 × C.
PV5G-6
PV5 6R FG-S A03 TC
PV5G-8
Model no. NPN and PNP
common type
ISO size 1
Model no.
CMF1
DIN terminal box type
Symbol Descriptions PV5-6R
A Solenoid position
A Solenoid position
FG-S 2-position single solenoid
FG-D 2-position double solenoid
CMF2
FHG-D P 3-position automatic port block
pressurization
FJG-D type 3-position ABR connection
FIG-D 3-position PAB connection
FPG-D 3-position automatic port block
CMFZ
B Option
B Option
Blank None
Technical data,
specifications
A Coolant proof
PV5-6R
A03 Side porting Rc3/8
<Example of model number>
B02 Back porting Rc1/4 (Rc3/8 for R port )
PV5-6R-FG-S-A03-TC B03 Back porting Rc3/8
Model: PV5/ISO size 1(I/O connector type)
A Solenoid position : P pressurization type
PV5-8R
2-position single solenoid
C Sub-plate port size : Side porting Rc3/8
Note
Descriptions
CMF1
I/O connector type
With I/O connector (M12)
(1) I/O connector
NPN and PNP common type
(2) Rated voltage 24 VDC
(3) Power indicator light Light and surge suppressor provided as standard
Note 1: Refer to Intro 5 Page for the circuit diagram of the type with light and surge suppressor. CMF2
CB1 A02
CMFZ
37
PV5-6R Series
Discrete valve; ISO size 1
Internal structure and parts list: I/O connector type
PV5-6R-FG-S PV5-6R-FG-D
2-position single solenoid
AB
2-position double solenoid
AB
a a b
R1 P R2 R1 P R2
15 6 8 5 3 4 10 2 1 9 7 12 13 15 6 8 5 3 4 10 2 1 12 13
PV5-6R-FHG-D PV5-6R-FPG-D
3-position all ports closed
A B
3-position all ports closed non-leak type
A B
a b a b
R1 P R2 R1 P R2
PV5-6R-FJG-D PV5-6R-FIG-D
3-position A/B/R connection 3-position P/A/B connection
AB AB
a b a b 15 11 3 4 1 2 10 12 8 5 14 6 13
R1 P R2 R1 P R2
15 11 3 4 1 2 10 12 8 5 6 13
38
MEMO
39
I/O connector type DIN terminal box type
Technical data, CMFZ CMF2 CMF1 PV5-8R PV5-6R Technical data, CMFZ CMF2 CMF1 PV5G-8 PV5G-6
specifications specifications
PV5-6R Series
Discrete valve; ISO size 1
Dimensions: I/O connector type (without sub-plate)
PV5-6R-FG-S PV5-6R-FG-D
2-position single solenoid 2-position double solenoid
36 Manual
36
Manual override
override
28
38
28
38
18
18
38.4
76.8
(350) 63.5 (350) 63.5
11.6 (7) 11.6 (7)
1
58
47.4
58
47.4
0.5
0.5
56.9
8.2
56.9
8.2
108 113.7
4-M5x35 4-M5x35
PV5-6R-FHG-D PV5-6R-FPG-D
PV5-6R-FJG-D 3-position and non-leak type
PV5-6R-FIG-D
3-position 36
Manual override
38
28
18
76.8
(350) 63.5
11.6 (7)
1
58
47.4
40
0.5
56.9
8.2
128.2
4-M5x35
38 90
4-M5x75
40
PV5-6R Series
Discrete valve; ISO size 1
Dimensions: I/O connector type (with sub-plate)
PV5G-6
PV5-6R-FG-S-* PV5-6R-FG-D-*
2-position single solenoid 2-position double solenoid
108 113.7
56.9 56.9
Manual
PV5G-8
Manual override A B A B
override
38
38
R1 P R2 R1 P R2
38.4
CMF1
DIN terminal box type
76.8
(350) 63.5 (350) 63.5
11.6 (7) 11.6 (7)
CMF2
95.5
95.5
84.9
84.9
31.1
31.1
37
37
22
22
14
14
CMFZ
13 13 2-Rc3/8: 5 (R1), 3 (R2) 13 13 2-Rc3/8: 5 (R1), 3 (R2)
25 25 3-Rc1/4, 3/8: 1 (P), 4 (A), 2 (B) 25 25 3-Rc1/4, 3/8: 1 (P), 4 (A), 2 (B)
1 (P) 1 (P)
5 (R1) 3 (R2) 5 (R1) 3 (R2)
Technical data,
specifications
50
62
50
62
2-Φ6.5 installation hole 4 (A) 2 (B) 2-Φ6.5 installation hole 4 (A) 2 (B)
85 85
PV5-6R
100 100
PV5-6R-FHG-D-*
PV5-8R
PV5-6R-FJG-D-*
PV5-6R-FIG-D-*
3-position 128.2
56.9
Sub-plate dimensions (CB1-*)
Manual override 2-RC1/4.3/8
CMF1
A B 26
R1 P R2 Pilot exhaust
2-RC1/8 prepared hole
76.8 4-M5
CMF2
53 for tapping
(350) 63.5
Depth 10
36 25
11.6 (7) A B
1
9
62
28
50
CMFZ
95.5
84.9
R1 P R2
18 31
85 2-Φ6.5 installation hole
100
31.1
37
Technical data,
22
specifications
14
50 2-RC3/8
1 (P) RC1/4, 3/8
5 (R1) 3 (R2) 50
50
62
12 14
9 11
41
Discrete valve ISO size 2
I/O connector type
Pilot operated 5 port valve ISO conformed valve
PV5-8R Series
Applicable cylinder bore size: max. Φ160
R1 P R 2
Individual specifications
Descriptions PV5-8R
3-position A/B/R Port size Note 1 Rc3/8 Rc1/2 Rc3/4
connection (FJG) Response time Single solenoid 40 (when turned ON), 60 (when turned OFF)
2-position
AB ms Double solenoid 40
a b Note 2 3-position 40 (when turned ON), 60 (neutral)
R1 P R
Single solenoid 0.62
2
Weight 2-position
Double solenoid 0.66
kg
Other than non-leak type 0.69
3-position P/A/B Note 3 3-position
All ports closed non-leak type 1.34
connection (FIG)
Note 1: G and NPT threads are available for piping port, so please consult with CKD.
AB Note 2: Response time is the value at supply pressure of 0.5 Mpa, oilless. This may change depending on the pressure and type of oil supplied.
a b
Note 3: The value is the weight without sub-plate.
R 1P R 2 Flow characteristics
P → A/B A/B → R1/R2
Port
Model no. Solenoid position C C
size b b
[dm3/(s·bar)] [dm3/(s·bar)]
2-position single solenoid 10.7 0.17 13.0 0.19
2-position double solenoid 10.7 0.17 13.0 0.19
3-position all ports closed 10.0 0.16 11.0 0.25
PV5-8R Rc3/8
3-position A/B/R connection 9.9 0.14 13.0 0.16
3-position P/A/B connection 11.0 0.12 12.0 0.21
3-position all ports closed no leakage 6.6 - 6.2 -
Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 × C.
PV5G-6
PV5 8R FG-S A03 TC
PV5G-8
Model no. NPN and PNP
common type
ISO size 2
Model no.
CMF1
DIN terminal box type
Symbol Descriptions PV5-8R
A Solenoid position
A Solenoid position
FG-S 2-position single solenoid
FG-D 2-position double solenoid
CMF2
FHG-D P 3-position automatic port block
pressurization
FJG-D type 3-position ABR connection
FIG-D 3-position PAB connection
FPG-D 3-position automatic port block
CMFZ
B Option
B Option
Blank None
Technical data,
specifications
A Coolant proof
PV5-6R
A04 Side porting Rc1/2
PV5-8R-FG-S-A03-TC A06 Side porting Rc3/4
Model: PV5/ISO size 2 (I/O connector type) B03 Back porting Rc3/8 (Rc1/2 for R port)
A Solenoid position : P pressurization type
2-position single solenoid
B04 Back porting Rc1/2
PV5-8R
C Sub-plate port size : Side porting Rc3/8 B06 Back porting Rc3/4
R port Rc1/2
Note
Descriptions
CMF1
I/O connector type
With I/O connector (M12)
(1) I/O connector
NPN and PNP common type
(2) Rated voltage 24 VDC
(3) Power indicator light Light and surge suppressor provided as standard
Note 1: Refer to Intro 5 Page for the circuit diagram of the type with light and surge suppressor. CMF2
CB2 A03
CMFZ
Side
specifications
43
PV5-8R Series
Discrete valve; ISO size 2
Internal structure and parts list: I/O connector type
PV5-8R-FG-S PV5-8R-FG-D
2-position single solenoid
AB
2-position double solenoid
AB
a a b
R1 P R2 R1 P R2
15 6 8 5 3 4 10 2 12 1 9 7 13 15 6 8 5 3 4 10 2 12 1 13
PV5-8R-FHG-D PV5-8R-FPG-D
3-position all ports closed
A B
3-position all ports closed non-leak type
A B
a b a b
R1 P R2 R1 P R2
PV5-8R-FJG-D PV5-8R-FIG-D
3-position A/B/R connection 3-position P/A/B connection
AB AB
15 11 3 4 1 2 10 12 14 8 5 13 6
a b a b
R1 P R2 R1 P R2
15 11 3 4 1 2 10 12 8 5 6 13
44
MEMO
45
I/O connector type DIN terminal box type
Technical data, CMFZ CMF2 CMF1 PV5-8R PV5-6R Technical data, CMFZ CMF2 CMF1 PV5G-8 PV5G-6
specifications specifications
PV5-8R Series
Discrete valve; ISO size 2
Dimensions: I/O connector type (without sub-plate)
PV5-8R-FG-S PV5-8R-FG-D
2-position single solenoid 2-position double solenoid
Manual
48 48 override
Manual override
38
50
38
50
24 24
52.8 105.6
(350) (350) 72.8
72.8
(7) 15.3 (7)
15.3
1
1
58
47.4
58
47.4
0.5
0.5
72.8
11
72.8
11
140.6 145.6
4-M6x45 4-M6x45
PV5-8R-FHG-D PV5-8R-FPG-D
PV5-8R-FJG-D 3-position and non-leak type
PV5-8R-FIG-D
3-position 48
Manual override
38
50
24
105.6
(350) 72.8
15.3 (7)
1
58
47.4
0.5
72.8
11
60
162.6
4-M6x45
50 110
4-M6x105
46
PV5-8R Series
Discrete valve; ISO size 2
Dimensions: I/O connector type (with sub-plate)
PV5G-6
PV5-8R-FG-S-* PV5-8R-FG-D-*
2-position single
140.6
2-position double 145.6
solenoid 72.8 solenoid 72.8
Manual
Manual override override
PV5G-8
A B A B
50
50
R1 P R2 R1 P R2
52.8 105.6
CMF1
DIN terminal box type
(350) 72.8 (350) 72.8
1
109.9
109.9
CMF2
99.3
99.3
51.4
51.4
42.1
42.1
32.1
32.1
22.1
22.1
CMFZ
16 16 2-Rc1/2: 5 (R1), 3 (R2) 16 16 2-Rc1/2: 5 (R1), 3 (R2)
31 31 3-Rc3/8, 1/2: 1 (P), 4 (A), 2 (B) 31 31 3-Rc3/8, 1/2: 1 (P), 4 (A), 2 (B)
1 (P) 1 (P)
5 (R1) 3 (R2) 5 (R1) 3 (R2)
Technical data,
specifications
62
75
62
75
2-Φ6.5 installation hole 2-Φ6.5 installation hole
4 (A) 2 (B) 4 (A) 2 (B)
(Note: Refer to below table for (Note: Refer to below table for
98 98
PV5-6R
A A
CB2-B 06 dimensions.) CB2-B 06 dimensions.)
112 112
PV5-8R-FHG-D-*
PV5-8R
PV5-8R-FJG-D-*
PV5-8R-FIG-D-*
3-position 162.6
72.8 Sub-plate dimensions (CB2-*)
Manual override A Model CB2- CB2- CB2-
CMF1
2-RCB
no. B 03 B 04 B 06
A 32 40
50
10
1
E
38
G 6.5 7.5
R1 P
R2 H 38 53
CMFZ
109.9
24 J J 42 55
C 2-ΦG installation hole K 62 84
D
99.3
L 32 42
M 50 62
Technical data,
51.4
specifications
42.1
N
M
32.1
N 51 63
22.1
L
Y
T 88 116
U 10 11
62
75
S
V 12 16
T
W 18 22
2-Φ6.5 installation hole
4 (A) 2 (B) X 18 23
98
Y 22 30
(Note: Refer to right table for 112
A
CB2-B 06 dimensions.)
47
Individual wiring type manifold ISO size 1
I/O connector type
Pilot operated 5 port valve ISO conformed valve
CMF1 Series
Applicable cylinder bore size: max. Φ100
Common specifications
Descriptions
Manifold type Manifold integrated
Common supply, common exhaust common supply and individual exhaust
Type of manifold Individual supply, common exhaust individual supply and individual exhaust
Multi-pressure air supply
Station number 1 to 10 stations
Type of valve and operator type Pilot operated soft spool valve
Working fluid Compressed air
Max. working pressure MPa 1.0
Min. working pressure MPa 0.15 0.20 (3-position)
Withstanding pressure MPa 1.50
Ambient temperature °C -5 to 60 (to be unfrozen)
Fluid temperature °C 5 to 60
Lubrication Not required
Protective structure Dust proof and jet-proof (IP65 structure)
Leakage cm3/min 10 (ANR) or less
(A, B → R port) 0.3 (ANR) or less only for 3-position all ports closed non-leak type Note 1
Vibration/shock m/s2 50 or less/300 or less
Working environment Use in the environment containing corrosive gas is not permissible.
Note 1: The default value is indicated.
Electric specifications
Descriptions
Rated voltage V DC 24
Rated voltage fluctuation range ±10%
Power consumption W (ampere A) 1.2 (0.050) *This value applies to type with light.
Heat proof class B (molded coil)
Wiring methods I/O connector
Individual specifications
Descriptions CMF1
Port size P/R1/R2 port Rc3/8, Rc1/2
Note 1 A/B port Rc3/8 Rc3/4
Single solenoid 30 (when turned ON) and 40 (when turned OFF)
Response 2-position
time Double solenoid 30
ms
Note 2
3-position 30 (when turned ON) and 60 (neutral)
Note 1: The piping port screw is compatible with G and NPT screws. Contact CKD for details.
Note 2: The response time is the value at supply pressure of 0.5 MPa, oilless. This may change depending on the pressure and type of oil supplied.
48
CMF1 Series
Individual wiring type manifold; ISO size 1
Flow characteristics
PV5G-6
Port P → A/B A/B → R1/R2
Model no. Solenoid position
size C [dm3/(s·bar)] b C [dm3/(s·bar)] b
2-position single solenoid 4.8 0.25 5.2 0.26
2-position double solenoid 4.8 0.25 5.2 0.26
PV5G-8
3-position all ports closed 4.4 0.27 4.7 0.27
CMF1 Rc1/4
3-position A/B/R connection 4.4 0.25 5.3 0.25
3-position P/A/B connection 4.8 0.27 4.7 0.27
3-position all ports closed no leakage 3.2 - 2.8 -
CMF1
DIN terminal box type
Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 × C.
CMF2
Control unit component Descriptions
Air filter (with automatic drain/manual drain) Filtration rating 5μm
Setting pressure (secondary pressure) 0.1 to 0.83MPa
Regulator
Pressure adjusting range 0.1 to 0.8MPa
CMFZ
Contact configuration 1C
Pressure switch
Rated current (inductive load) 125 VAC 15A and 250 VAC 15A
Air release valve (only single) Working pressure range 0.15 to 1.0MPa
Technical data,
specifications
Refer to pneumatic/vacuum/auxiliary components catalog (No. CB-024SA) for specifications of pressure switch APE-8F-*.
PV5-6R-FG-S-TC is used for air release valve.
PV5-6R
PV5-8R
CMF1
I/O connector type
CMF2
CMFZ
Technical data,
specifications
49
CMF1 Series
Individual wiring type manifold; ISO size 1
How to order I/O connector type (without control unit)
ISO size 1
CMF 1 5 02 L HY1 B DU SB
Model no.
Symbol Descriptions CMF1
Model no. A Station number
A Station number
1 1 station
to to
10 10 stations
A
B
R1 P R2
D side (bottom)
50
CMF1Series
Individual wiring type manifold; ISO size 1
How to order I/O connector type (with control unit)
ISO size 1
PV5G-6
Model no.
CMF 1 5 02 L A HY1 B DU TC Symbol Descriptions CMF1
A Station number
Station number
PV5G-8
A
Model no. 3 3 stations
Note 1
to to
10 10 stations
CMF1
DIN terminal box type
B A/B port size
Note 2 02 Rc 1/4
03 Rc 3/8
HX1 Rc1/4, Rc3/8 mix
CMF2
C A/B port position
C A/B port position
Note 3 Blank Right side
L Left and right sides
H Left side
CMFZ
D Control unit
Note 4,
Z Rear side
Note 5 T Flexible selection (plug attached)
Control unit
Technical data,
D Reg. : Regulator, Air : Air release valve, Pre : Pressure switch
specifications
A Filter with auto drain Reg. Air
AP Filter with auto drain Reg. Air Pre
Note on model no. selection M Filter with manual drain Reg. Air
MP Filter with manual drain Reg. Air Pre
PV5-6R
Note 1: This is the station number including 2 stations of unit base.
Note 2: HX indicates mix of port size. Contact CKD for details. Filter with auto drain
F
(air release valve plug)
Reg.
Note 3: C indicates port position.
Ports will be plugged unless indicated. Filter with manual drain
Note 4: Air release valve is 24 VDC and has light, surge suppressor
G
(air release valve plug)
Reg.
and manual override.
PV5-8R
Note 5: The pressure switch has no indicator light. (Indicator light
C With air release valve Air
is available as custom order.) E R port size
Note 6: Instruction of F indicates the port position. E R port size
The opposite side of indicated port will be plugged.
03 Rc 3/8
04 Rc 1/2
CMF1
<Example of model number>
51
CMF1 Series
Individual wiring type manifold; ISO size 1
Dimensions: I/O connector type
CMF1 P/R port size A B
Rc 3/8 21 30
Common exhaust Rc 1/2 26 26
L2 (43n + 64)
L1 (43n + 43)
4n-M5 depth 9 51
R side 45
2-Rc 1/8 B
28 Pilot exhaust port
128.2 (3-position)
38.4 (manual override po.)
76.8 (manual override po.)
70 (silencer box)
24 24
A A
D side
120
U side
95
36
18
P
56.9
R
(350)
(7)
3
-Rc 3/8,1/2
4-(9 × 11) 6
installation hole
L side
11.7
2n
4n -Rc 1/4, 3/8 56 (silencer box)
159.5
119.5
107.9
60
45
45
19
A A A A A A
32
43 43
CMF1
Individual exhaust
n-Rc1/4, 3/8
2n
-Rc 1/4, 3/8
189.5
4n
149.5
137.9
75.5
60
45
45
19
A A A A A A A
32
L side 43 43
CMF1
Back porting 2n-Rc1/4, 3/8
3
-Rc 3/8,1/2
6
A A A A A A A
R
15 22
24 24
A A
120
U side D side
95
B B B B B B B
R
8 8 B 2-Rc 1/8
4-(9 × 11)
43 43 45 Pilot exhaust port
installation hole
51
L1 (43n + 43)
L2 (43n + 64)
R side
52
CMF1Series
Individual wiring type manifold; ISO size 1
Dimensions: I/O connector type
PV5G-6
With control unit P/R port size
Rc 3/8
A
21
B
30
32 Rc 1/2 26 26
R side
2
Pressure switch 4 -Rc 3/8,1/2
PV5G-8
97
R
24 24
A A
120
U side D side
95
R
125
CMF1
DIN terminal box type
B
2-Rc 1/8 45
4-(9 × 11) Pilot exhaust port 51
installation hole
JIS symbol
CMF2
L side
Rc 3/8 R1 P R2
B
P port A Individual exhaust spacer
CMF1-R-*
B R
CMFZ
2n
-Rc 1/4, 3/8
194
4n B P
A
FR installation spacer
125
FRB
Technical data,
60
B B B B B B B
specifications
Air release valve
45
45
PV5-6R-FG-S-TC
19
A A A A A A A
Pressure switch
APE-8F-*
43 43 43
L1 (43n + 43) Filter and regulator unit
L2 (43n + 64) 157
R1 P R2 OUT P1
PV5-6R
How to order
Spacer type regulator
PV5-8R
CMF 1 SR A T05 C
CMF1
1 P P port MPa display Blank
CMF1-SR-P-T05 CMF1-SR-A-T05C
CMFZ
CMF1-SR-B-T05C
Spacer type regulator JIS symbol JIS symbol
CMF1-SR-P-T05 CMF1-SR-A-T05C
Technical data,
specifications
a AB A
R1 R2
Pressure
B
adjustment knob a
41.5
41
3 41
120 At adjusting a A 3
238 pressure At adjusting pressure 120
R 1 P R2 238
53
Individual wiring type manifold ISO size 2
I/O connector type
Pilot operated 5 port valve ISO conformed valve
CMF2 Series
Applicable cylinder bore size: max. Φ160
Common specifications
Descriptions
Manifold type Manifold integrated
Common supply, common exhaust common supply and individual exhaust
Type of manifold Individual supply, common exhaust individual supply and individual exhaust
Multi-pressure air supply
Station number 1 to 10 stations
Type of valve and operator type Pilot operated soft spool valve
Working fluid Compressed air
Max. working pressure MPa 1.0
Min. working pressure MPa 0.15, 0.20 (3-position) Note 1
Withstanding pressure MPa 1.50
Ambient temperature °C -5 to 60 (to be unfrozen)
Fluid temperature °C 5 to 60
Lubrication Not required
Protective structure Dust proof and jet-proof (IP65 structure)
Leakage cm3/min 10 (ANR) or less
(A, B → R port) 0.3 (ANR) or less only for 3-position all ports closed non-leak type Note 1
Vibration/shock m/s2 50 or less/300 or less
Working environment Use in the environment containing corrosive gas is not permissible.
Note 1: The default value is indicated.
Electric specifications
Descriptions
Rated voltage V DC 24
Rated voltage fluctuation range ±10%
Power consumption W (ampere A) 1.2 (0.050) *This value applies to type with light.
Heat proof class B (molded coil)
Wiring methods I/O connector
Individual specifications
Descriptions CMF2
Port size P/R1/R2 port Rc3/8, Rc1/2
Note 1 A/B port Rc3/8 Rc3/4
Response Single solenoid 40 (when turned ON), 60 (when turned OFF)
2-position
time Double solenoid 40
ms
Note 2 3-position 40 (when turned ON), 60 (neutral)
Note 1: The piping port screw is compatible with G and NPT screws. Contact CKD for details.
Note 2: The response time is the value at supply pressure of 0.5 MPa, oilless. This may change depending on the pressure and type of oil supplied.
Flow characteristics
P → A/B A/B → R1/R2
Model no. Port size Solenoid position C [dm3/ C [dm3/
b b
(s·bar)] (s·bar)]
2-position single solenoid 9.7 0.12 11.0 0.14
2-position double solenoid 9.7 0.12 11.0 0.14
3-position all ports closed 9.2 0.12 10.1 0.15
CMF2 Rc3/8
3-position A/B/R connection 9.2 0.11 11.6 0.11
3-position P/A/B connection 9.6 0.11 10.2 0.18
3-position all ports closed no leakage 6.2 - 5.9 -
Note 1: Effective sectional area S and sonic conductance C are converted as S 5.0 × C.
54
CMF2 Series
Individual wiring type manifold; ISO size 2
How to order I/O connector type
ISO size 2
PV5G-6
CMF 2 5 03 L 04 B SB Model no.
Symbol Descriptions CMF2
PV5G-8
Model no. A Station number
A Station
number 1 1 station
to to
10 10 stations
CMF1
DIN terminal box type
B A/B port size
B A/B port size
Note 1 03 Rc 3/8
04 Rc 1/2
CMF2
HX2 Rc 3/8, Rc 1/2 mix
C A/B port position
C A/B port position
Note 2 Blank Right side
L Left and right sides
CMFZ
D P/R port size H Left side
Z Rear side
E P/R port
position Note 3, T Flexible selection (plug attached)
Technical data,
specifications
Note 4
D P/R port size
04 Rc 1/2
Note on model no. selection 06 Rc 3/4
HY2 Rc1/2, Rc3/4 mix
PV5-6R
Note 1: HX indicates mix of port size. Contact CKD for details.
Note 2: C indicates port position. E P/R port position
Ports will be plugged unless indicated.
Note 3: E indicates port position.
B Top and bottom
The opposite side of indicated port will be plugged. D Bottom
PV5-8R
Note 4: When the G silencer box is selected, the P-port
position is selected from B, D, U, or T.
U Top
Note 5: When the G silencer box type is selected, a plug E P is top, R is bottom.
assembly is provided on both top and bottom. F P is bottom, R is top.
T Flexible selection (plug attached)
<Example of model number>
CMF1
I/O connector type
F HY configuration
CMF25-03L-04B-SB F HY configuration
Model: Manifold ISO size 2
Blank When port size other than HY2 is selected in D .
A Station number : 5 stations DU Rc1/2 is bottom, Rc3/4 is top.
B C A/B port : Rc3/8 (left-right sides porting) UD Rc1/2 is top, Rc3/4 is bottom.
D E P/R port : Rc1/2 (top-bottom side porting) CMF2
G Silencer box : Selected (D side installation)
G Silencer box
G Silencer box
Note 5 Blank None
U side (top)
SB Selected (D side installation)
CMFZ
R1 P R2
The valve unit must be prepared separately. Refer to page 43 for details on
ordering the valve. In addition to each model, Manifold Specifications on
page 64 must be submitted when preparing the manifold with valves.
Technical data,
specifications
A
B
R1 P R2
D side (bottom)
55
CMF2 Series
Individual wiring type manifold; ISO size 2
Dimensions: I/O connector type
CMF2 P/R port size A B
Rc 1/2 30 32
Common exhaust L2 (56n + 74)
Rc 3/4 37 25
L1 (56n + 54) 61
50
4n-M6 depth 12 R side
38 2-Rc 1/8 B
Pilot exhaust port
162.6 (3-position)
33
A
R
D side
160
144
120
U side
24
U
48
33
A
R
72.8
(7)
4-(11 × 13) 3
-Rc 1/2, 3/4
(350)
6
installation hole
L side
15.3
189.5
117.9
129.5
70
B B B B B B B
54
45
22
A A A A A A A
37 2.5 2.5
56 56
CMF2
Individual exhaust
Individual supply spacer
Individual exhaust spacer 15.3
Exhaust pressurization individual exhaust spacer
n-Rc 3/8,1/2
2n
4n -Rc 3/8,1/2
229.5
169.5
157.9
88
70
B B B B B B B
54
45
22
A A A A A A A
37 2.5 2.5
56 56
CMF2 L side
A A A A A A A
25 35
33
A
R
120
144
160
U side D side
P
33
R
A
B B B B B B B
2-Rc 1/8
10 10 B Pilot exhaust port
4-(11 × 13)
50
55 56 installation hole
61
L1 (56n + 54) 70
L2 (56n + 74)
R side
56
CMF2 Series
Individual wiring type manifold; ISO size 2
How to order
Spacer type regulator
PV5G-6
CMF 2 SR A T05 C
PV5G-8
A Size B Decompression port position C Pressure gauge D Check valve
2 ISO size 2 P P port MPa display Blank No
T05
(With limit mark)
A A port C Yes
B B port Indicate "no check
CMF1
DIN terminal box type
valve" (blank) for
SR-P, and "with
check valve" (C) for
SR-A and SR-B.
*Note that the pressure gauge direction differs for the CMF2-SR-A-T05C.
CMF2
CMFZ
Technical data,
specifications
CMF2-SR-P-T05 JIS symbol
CMF2-SR-P-T05
CMF2-SR-A-T05C JIS symbol
CMF2-SR-A-T05C
CMF2-SR-B-T05C a AB b A
PV5-6R
B
a b
P R1 P R2
CMF2-SR-B-T05C
B
55.5
55.5
PV5-8R
53 53
a A b
159 159
R 1 P R2
303 303
CMF1
I/O connector type
CMF2
CMFZ
Technical data,
specifications
57
CMFZ Series
Mix manifold; ISO size 1, 2 mix
How to order I/O connector type
CMFZ 5 HX3 L HY3 B DU
Quantity
of size 1 Model no.
Quantity Symbol Descriptions CMFZ
of size 2
A Station number
A Station
number 2 2 stations
to to
ISO size 1, 2
mix manifold 10 10 stations
U side size 1
D side size 2
CMFBZ-00L
With connecting bracket
and O ring
ISO size 1, 2
1 Mix
Block
U side size 2
D side size 1
CMFBZ-00R
With connecting bracket
and O ring
58
CMFZ
Series
Mix manifold; ISO size 1, 2; appearance image
Mix manifold appearance image
PV5G-6
30
PV5G-8
U side D side
D
U
CMF1
DIN terminal box type
Size 1 foot
Size 2 foot
(FB1-04)
(FB2-06)
CMF2
Size 1 block
Size 2 block
(CMFB1-02L)
(CMFB2-03L)
CMFZ
Mix blocks
(CMFBZ-00R)
Technical data,
specifications
70
B B
60
B B
A A A A
PV5-6R
30
PV5-8R
U side D side
U
CMF1
Size 1 foot I/O connector type
CMF2
Size 2 foot
(FB1-04)
(FB2-06)
Size 1 block Size 2 block
(CMFB1-02L) (CMFB2-03L)
CMFZ
Mix blocks
(CMFBZ-00L)
Technical data,
specifications
70
B B
B B
60
A A A A
59
CMF1/2 Series
Manifold option
Model no.
Options Remarks
ISO size 1 ISO size 2
1. Individual supply spacer 1. Clamp for individual
supply port, used for
R1 A P B R2 CMF1-P-02 ( Rc1/4 ) CMF2-P-03 ( Rc3/8 )
P multi-pressure
P 03 ( Rc3/8 ) 04 ( Rc1/2 )
2. Individual exhaust for
exhaust pressurization
4. Masking plate
PV5-6R
CM1-00 CM2-00 PV5-8R
Discrete masking plate
Manifold (CMF1,
CM1-01 CM2-01 CMF2) P/R1/R2 port
Masking plate
5. Base gasket
PV5-6R
PV5G-6-BASE-GASKET PV5G-8-BASE-GASKET
PV5-8R
6. Set screw
CMF1-M5X35 CMF2-M6X45
60
CMF1/2 Series
Technical data (1) Type of manifold
Type of manifold
A wide range of air supply, exhaust, and piping combinations is available.
PV5G-6
Select the functions best suited to your application.
General use Special use (exhaust pressurization) Common descriptions for general and special purpose
Common exhaust method This is suitable for supplying more than one Back porting method
different pressure to one manifold.
PV5G-8
This is the most commonly used method. Each If side porting is not possible, pipes can be
solenoid valve air supply and exhaust are grouped Example: To drive two piston cylinders connected from either the A or B port, or all
at one position with P (air supply) and R (exhaust) used in a welding machine. pipes can be connected from the bottom of
ports passing through the connected manifold block. Common type the manifold.
CMF1
DIN terminal box type
Exhaust
Air supply
Exhaust
Air supply pressurization type
CMF2
Exhaust
CMFZ
R1 and 2 (exhaust) ports are independent for
Exhaust pressurization type
each solenoid valve, so the adjacent cylinder solenoid valve
will not pop out because of back pressure.
Technical data,
specifications
An individual exhaust spacer (CMF1-R-*) can
be inserted between the manifold block and
valve to enable individual exhaust. R2
Individual exhaust
spacer CMF1-R-* P
PV5-6R
R1
Exhaust B A B A B A
Air supply
Manifold
PV5-8R
Individual supply method
P (air supply) ports are independent for each
valve, so a different pressure can be supplied
to a specific valve in the manifold.
An individual supply spacer (CMF1-P-*) can be
CMF1
inserted between the manifold block and valve
CMF2
Air supply
Exhaust
CMFZ
61
CMF1 Series
Manifold specifications Issue / /
ISO size 1 I/O connector type Your company name
●Contact ●Quantity set ●Request date / / Contact
Slip No. Order No. Order No.
●Manifold model no.
CMF 1
A B
- C D
- E F G
- H
- I
-TC
Option
Station number A/B port position P/R port position Silencer box
ISO size A/B port size P/R port size HY configuration
A ISO size B Station No. C A/B port size D A/B port position E P/R port size F P/R port position G HY configuration H Silencer box I Option
1 PV5-6R 1 1 station 02 Rc1/4 Blank Right side 03 Rc3/8 B Top and bottom Other than HY is Blank None Blank None
Blank
to to 03 Rc3/8 L Left/right sides 04 Rc1/2 D Bottom selected for E . SB Selected (D side) A Coolant proof
10 10 stations HX1 Rc1/4 ,Rc 3/8 mix H Left side HY1 Rc3/8 ,Rc 1/2 mix U Top Rc 3/8 is bottom,
DU Note: I is the valve option selected
Z Rear side E P top, R bottom Rc /2 is top
1
when assembling the manifold.
T Plug attached F P bottom, R top Rc 3/8 is top,
UD
T Plug attached Rc 1/2 is bottom
U side (top)
R1 P R2
(1)
This applies when rated voltage 24 VDC is used and light and
(2) surge suppressor is installed.
L side (left)
R side (right)
(3) Station number No.
Indicate left solenoid valve No. (1) to (6) and (9) in the following solenoid valve
(4)
No. field when placing an order.
A To select an option, circle the field for the relevant option below.
(5)
B
Station number No 1 2 3 4 5 6 7 8 9 10
Solenoid valve
type No PV5-6R
R1 P R2
D side (bottom)
Plug position should be R
indicated when L is
Solenoid valve type No. selected in D L
AB
a
2-position Air supply spacer
PV5-6R-FG-S-TC (1)
single solenoid R1 P R2 Exhaust spacer
2-position a
AB
b Pilot check valve
PV5-6R-FG-D-TC (2)
double solenoid R1 P R 2 Spacer type
CMF*-SR-P
Option
3-position AB CMF*-SR-A
a b regulator
all ports PV5-6R-FHG-D-TC (3) CMF*-SR-B
block R1 P R 2
Flow Air supply passage shut off
3-position a
AB
b
path
shut
A-B-R PV5-6R-FJG-D-TC (4) Exhaust passage shut off
off plate
connection R1 P R 2
A mixed bore size should 02
3-position a
AB
b
be indicated when HX is
P-A-B PV5-6R-FIG-D-TC (5) selected for C . 03
connection R 1P R 2
A B
3-position all ports a b
Sub-base
62
CMF1 Series
Manifold specifications Issue / /
PV5G-6
ISO size 1 I/O connector type (with control unit) Your company name
●Contact ●Quantity set ●Request date / / Contact
PV5G-8
Slip No. Order No. Order No.
●Manifold model no.
CMF 1 - - - - -TC
CMF1
DIN terminal box type
A B C D E F G H I
ISO size A/B port size Control unit R port position Option
Station number A/B port position R port size HY configuration
CMF2
A ISO size B Station No. C A/B port size D A/B port position E Control unit (option) F R port size G R port position H HY configuration
1 PV5-6R 3 3 stations 02 Rc1/4 Blank Right side A Filter regulator with auto drain/air release valve 03 Rc3/8 B Top and bottom Other than HY is
Blank
to to 03 Rc3/8 L Left/right sides AP Filter regulator with auto drain, air release valve/pressure switch 04 Rc1/2 D Bottom selected for F .
10 10 stations HX1 Rc1/4, Rc3/8 mix H Left side M Filter with manual drain regulator/air release valve HY1 Rc3/8, Rc1/2 mix U Top Rc 3/8 is bottom,
DU
Z Rear side MP Filter with manual drain regulator, air release valve/pressure switch T Plug attached Rc 1/2 is top
CMFZ
Note: When using the control unit, select a
number of stations including two for the T Plug attached F Filter regulator with auto drain (air release valve plug) Rc 3/8 is top,
UD
unit base.
U side (top) G Filter with manual drain regulator (air release valve plug) Rc 1/2 is bottom
R1 R2 C Air release valve
I Option
Note: The air release valve with the
Blank None
Technical data,
specifications
A
(5)
control unit has light and surge
B A Coolant proof
suppressor and manual override.
(4) Note: I is the valve
L side (left) R side (right) Station number No. option selected
(3)
when assembling
(2) the manifold.
(1)
This applies when rated voltage 24 VDC is used and light and
surge suppressor is installed.
PV5-6R
Control unit
P Indicate left solenoid valve No. (1) to (6) and (9) in the following solenoid valve
No. field when placing an order.
To select an option, circle the field for the relevant option below.
Use vertical with the
filter facing down. Station number No 1 2 3 4 5 6 7 8 9 10
PV5-8R
D side (bottom) Solenoid valve
type No PV5-6R
Plug position should be R
Solenoid valve type No. indicated when L is
a AB selected in D L
2-position
PV5-6R-FG-S-TC (1) Air supply spacer
single solenoid
CMF1
R1 P R2
a b
CMF2
all ports PV5-6R-FHG-D-TC (3) CMF1-SR-A
regulator
block R1 P R 2
CMF1-SR-B
3-position a
AB
b Flow
Air supply passage shut off
A-B-R PV5-6R-FJG-D-TC (4) path
shut
connection R1 P R 2 off plate Exhaust passage shut off
CMFZ
3-position a
AB
b
A mixed bore size should 02
P-A-B PV5-6R-FIG-D-TC (5) be indicated when HX is
connection R 1P R 2
selected for C . 03
A B
3-position all ports
Technical data,
a b
specifications
Sub-base
63
CMF2 Series
Manifold specifications Issue / /
ISO size 2 I/O connector type Your company name
●Contact ●Quantity set ●Request date / / Contact
Slip No. Order No. Order No.
●Manifold model no.
CMF 2
A B
- C D
- E F G
- H
- I
-TC
Option
Station number A/B port position P/R port position Silencer box
ISO size A/B port size P/R port size HY configuration
A ISO size B Station No. C A/B port size D A/B port position E P/R port size F P/R port position G HY configuration H Silencer box I Option
2 PV5-8R 1 1 station 03 Rc3/8 Blank Right side 04 Rc1/2 B Top and bottom Other than HY is Blank None Blank None
Blank selected for E .
to to 04 Rc1/2 L Left/right sides 06 Rc3/4 D Bottom SB Selected (D side) A Coolant proof
10 10 stations HX2 Rc3/8 ,Rc 1/2 mix H Left side HY2 Rc1/2 ,Rc 3/4 mix U Top Rc 1/2 is bottom,
DU Note: I is the valve option selected
Z Rear side E P top, R bottom Rc /4 is top
3
This applies when rated voltage 24 VDC is used and light and
(1)
surge suppressor is installed.
(2)
L side (left) R side (right)
(3) Station number No.
(4) Indicate left solenoid valve No. (1) to (6) and (9) in the following solenoid valve
No. field when placing an order.
A
(5)
To select an option, circle the field for the relevant option below.
B
Station number No 1 2 3 4 5 6 7 8 9 10
Solenoid valve
type No PV5-8R
R1 P R2
D side (bottom)
Plug position should be R
indicated when L is
Solenoid valve type No. selected in D L
AB
a
2-position Air supply spacer
PV5-8R-FG-S-TC (1)
single solenoid R1 P R2 Exhaust spacer
2-position a
AB
b Pilot check valve
PV5-8R-FG-D-TC (2)
double solenoid CMF*-SR-P
R1 P R 2 Spacer type
Option
3-position AB CMF*-SR-A
a b regulator
all ports PV5-8R-FHG-D-TC (3) CMF*-SR-B
block R1 P R 2
Flow Air supply passage shut off
3-position a
AB
b
path
shut
A-B-R PV5-8R-FJG-D-TC (4) Exhaust passage shut off
off plate
connection R1 P R 2
A mixed bore size should 03
3-position a
AB
b
be indicated when HX is
P-A-B PV5-8R-FIG-D-TC (5) selected for C . 04
connection R 1P R 2
A B
3-position all ports a b
Sub-base
64
CMFZ Series
Manifold specifications Issue / /
PV5G-6
ISO size 1, 2 mix I/O connector type Your company name
●Contact ●Quantity set ●Request date / / Contact
PV5G-8
Slip No. Order No. Order No.
●Manifold model no.
CMF Z - - - -TC
CMF1
DIN terminal box type
A B C D E F G I
CMF2
A ISO size B Station No. C A/B port size D A/B port position E P/R port size F P/R port position G HY configuration I Option
Z Mix of size 1, 2 1 1 station HX3 1:02 · 2:03 Blank Right side HY3 1:03 · 2:04 B Top and bottom Size 1 is bottom, Blank None
DU
to to HX4 1:02 · 2:04 L Left/right sides HY4 1:03 · 2:06 D Bottom Size 2 is top A Coolant proof
10 10 stations HX5 1:03 · 2:03 H Left side HY5 1:04 · 2:04 U Top Size 1 is top, Note: I is the valve option selected
UD
HX6 1:03 · 2:04 Z Rear side HY6 1:04 · 2:06 E P top, R bottom Size 2 is bottom
CMFZ
when assembling the manifold.
T Plug attached F P bottom, R top
U side (top) T Plug attached
R1 P R2
Technical data,
specifications
(1)
This applies when rated voltage 24 VDC is used and light and
(2) surge suppressor is installed.
L side (left) R side (right)
(3) Station number No.
PV5-6R
(4) Indicate left solenoid valve No. (1) to (6) and (9) in the following solenoid valve
No. field when placing an order.
A
(5) To select an option, circle the field for the relevant option below.
B
Station number No 1 2 3 4 5 6 7 8 9 10
Solenoid valve PV5-6R
PV5-8R
R1 P R2
D side (bottom)
type No PV5-8R
Solenoid valve type No.
Plug position should be R
a
AB indicated when L is
2-position selected in D L
PV5-*R-FG-S-TC (1)
single solenoid
CMF1
R1 P R2 Air supply spacer
3-position a
AB
b
CMF*-SR-B
A-B-R PV5-*R-FJG-D-TC (4) Flow
Air supply passage shut off
connection R1 P R 2
path
shut
Exhaust passage shut off
CMFZ
off plate
3-position a
AB
b
P-A-B PV5-*R-FIG-D-TC (5) A mixed bore size 02
connection R 1P R 2 should be indicated
A B when HX is selected 03
3-position all ports a b
for C .
Technical data,
PV5-*R-FPG-D-TC (6) 04
specifications
block no leakage R1 P R 2
Sub-base
65