One-Way Slab Design

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 3

PROJ NAME.

CLIENT.
PROJ NO.
JOB NO.
DOC NO.
JOB TITLE One-Way Slab Design
LOC.
DESIGN CODE ACI 318-99 BOUNDARY COND; Simply Supported
UNIT IMPERIAL

(1. Input Data


L - 7.25 ft Clear Span Length
h - 5.00 in Assumed Slab Thickness
d - 4 in Assumed Effective Depth
C-con; - 0 - Coefficient Of M- At Continuous End
C+mid - l/9 - Coefficient Of M+ At Mid
C-dis; - 0 - Coefficient Of M- At Discontinuous End
D.L - 20.00 lb/ft2 Unfactored Dead Load (Excluding Own Wt;)
L.L - 150.00 lb/ft2 Unfactored Live Load
A - 1.40 - Dead Load Increasing Factor
B - 1.70 - Live Load Increasing Factor
Ø - 0.9 - Strength Reduction Factor
a - 1 in Assumed Rectangular Stress Block Depth
F'c - 3000 lb/in 2
Concrete Compressive Strength
Fy - 40000 lb/in 2
Steel Yield Strength

(2. Output Data


ẞ1 - 0.850 - Equivalent Rectangular Stress Block Distribution Factor {ẞ1=2ẞ}
Wown - 62.50 lb/ft Own Weight Of Slab
WDL - 115.50 lb/ft Total Factored Dead Load
WLL - 255.00 lb/ft Total Factored Live Load
Wtotal - 370.50 lb/ft Total Factored Load
Balanced Steel Ratio {0.85x ẞ1x (fc'/fy)x (87000/(87000+fy))}
ῤb - 0.037 -
Maximum Steel Ratio {0.75x ῤb}
ῤmax - 0.028 -
Actual Steel Ratio {ῤmax/2}
ῤact - 0.014 -
M- At Continuous End {C-con;x Wux L2}
M-u con; - 0.00 lb-ft
M+ At Mid {C+midx Wux L2}
M+u mid - 2163.82 lb-ft
M- At Discontinuous End {C-endx Wux L2}
M-u dis; - 0.00 lb-ft
Required Effective Depth {By Using ῤmax;} {Mu=Øx ῤx fyx bd2x (1-0.59x ῤx (fy/f'c))}
d - 1.66 in
Assumed Value Is Ok. Use Assumed Value!!
Actual Effective Stress Block Depth(3-Cycle) {(Asfy)/(0.85x f'cx b)}

a - 0.24 in
PROJ NAME.
CLIENT.
PROJ NO.
JOB NO.
DOC NO.
JOB TITLE One-Way Slab Design
LOC.
(3. Results
Required Minimum Steel {(0.0018 or 0.002)x bh}
Asmin - 0.12 in /ft
2

Required Negative Steel At Continuous End {M-u con;/(Øx fyx (d-(a/2)))}


As-con; - 0.00 in2/ft Use Minimum Steel Area!!
Required Positive Steel At Mid {M+u mid/(Øx fyx (d-(a/2)))}
As+mid - 0.19 in2/ft
Required Negative Steel At Discontinuous End {M-u dis;/(Øx fyx (d-(a/2)))}
As-dis - 0.00 in2/ft Use Minimum Steel!!

Main Bar Temperature & Shrinkage

Continuous End 10mm 10mm


Spacing (in) 12in @ C/C 12in @ C/C
As req;/As prov; 0.986 0.99
Mid 10mm 10mm
Spacing (in) 7in @ C/C 12in @ C/C
As req;/As prov; 0.891 0.986
Discontinuous End 10mm 10mm
Spacing (in) 12in @ C/C 12in @ C/C
As req;/As prov; 0.986 0.986
PROJ NAME.
CLIENT.
PROJ NO.
JOB NO.
DOC NO.
JOB TITLE One-Way Slab Design
LOC.

You might also like